Figure 6-13: Clear Floor Space required in kitchens (C) J Wiley, S Bliss Accessible Kitchen Design: Best Practices

Layout specifications for accessible kitchen design:

This article describes the layout and specifications for accessible kitchens and kitchen work spaces. We cover Accessible kitchen work aisles, passageways. Knee space requirements for accessible kitchens.

Clear floor space specifications for accessible kitchens. Counter & appliance height in accessible kitchens. Storage height, handles, & controls for accessible kitchen design.

Sink & dishwasher work center design for accessible kitchens. Refrigerator work space for accessible kitchen design

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Accessible Kitchen Design Recommenations

Figure 6-1: Accessible Kitchen Design Specs:  (C) J Wiley S BlissThis article series discusses current best design practices for kitchens and bathrooms, including layout, clearances, work space, and accessible kitchen and bathroom layout, clearances, turning space, grab bars, controls, etc.

[Click to enlarge any image]

We include advice on choosing and installing kitchen countertops, cabinets, and kitchen or bathroom flooring, sinks, and other plumbing fixtures and fixture controls such as faucets. A list of kitchen and bath product manufactures and sources is included.

As described in detail in Chapter 6 of Best Practices Guide to Residential Construction (Steve Bliss, J Wiley & Sons) :

To make a kitchen fully functional for wheelchair users and other seated occupants requires simple commonsense changes, like placing knobs within reach, as well as more significant changes, such as lowering counters and providing knee space below.

The guidelines below, based on ANSI (American National Standards Institute) A117.1 standards, are a good starting point in design, but they should be tailored to the size, reach, and specific capabilities of the occupants.

Work Aisles and Passageways in Accessible Kitchen Design

Clear space at doorways and passageways must be at least 32 inches wide and no more than 24 inches long in the direction of travel. Eliminate any thresholds at doorways.


The minimum work aisle with counters or appliances on both sides should be 40 inches.

Walkways with counters or appliances on only one side can be 36 inches wide, but if a walkway turns a corner, as in Figure 6-10 (at left), one leg of the walkway space should be widened to 42 inches for a wheelchair to make the turn.

[Click any image or table to see an enlarged version with additional detail, commentary & source citation.]


Figure 6-1: Accessible Kitchen Design Specs:  (C) J Wiley S Bliss

From a table or eating counter to a wall, leave 54 inches for wheelchair access.

In a U-shaped kitchen the minimum clearance between counters is 60 inches (Figure 6-11 at left).

Knee Space Requirements for Accessible Kitchens

Wherever possible, provide knee space for a seated user below or adjacent to sinks, cooktops, ranges, dishwashers, refrigerators, and ovens.

To accommodate a seated user, below-counter knee space should be a minimum of 30 inches wide, 27 inches high in front, and 19 inches deep, with a minimum 9-inch-high toe space, which will accommodate most wheelchair footrests.

Figure 6-1: Accessible Kitchen Design Specs:  (C) J Wiley S Bliss

Protect users from exposed pipes and mechanicals with a protective panel and insulation (Figure 6-12 above).

Clear Floor Space Needs for Accessible Kitchens

Figure 6-12: Accessible Kitchen design knee space required (C) J Wiley S Bliss

To make work centers universally accessible, provide a clear floor space of 30x48 inches or 48x30 inches, centered in front of the sink, dishwasher, cooktop, oven, and refrigerator.

In an accessible (or other) kitchen design layout, clear floor spaces for different work areas may overlap, and the long dimension can include up to 19 inches deep of knee space below counters (Figure 6-13).

Counter and Appliance Height for Accessible Kitchen Designs

he optimal height for most seated occupants at counters, sinks, and cooktops is about 32 inches and should be no higher than 34 inches.

Storage Height Specifications for Accessible Kitchen Designs

Figure 6-1: Accessible Kitchen Design Specs: storage space (C) J Wiley S Bliss


Most seated users in a kitchen can fully reach shelving located from 15 to 48 inches high.

Storage located from about 20 to 44 inches is considered optimal for accessible kitchen designs.

In an accessible-designed kitchen you should use open shelving, shelf racks on pantry doors, and drawers or roll-out shelving for easy access (Figure 6-14).

Handles and Control Recommendations for Accessible Kitchens

Controls, handles, and door and drawer pulls should be operable with one hand, require minimal strength, and not require tight grasping, pinching, or twisting of the wrists. Lever-action handles work well for doors and faucets. A simple test is to try to operate the controls with a closed fist.

Mount wall cabinet doors at the bottom of the cabinets and base cabinet pulls at the top of the cabinets.

Sink and Dishwasher Work Center for Accessible Kitchen Designs

Use a shallow sink mounted at 32 to 34 inches (32 preferred) with the drain in the rear so it does not interfere with knee space (Figure 6-15 below).

The garbage disposal must also be offset so it does not interfere with knee space. A tall faucet and pullout spray attachment are recommended to simplify work at the sink. Locate the dishwasher adjacent to the sink or no more than 12 inches away.

Figure 6-1: Accessible Kitchen Design Specs: accessible sink and dishwasher work centers (C) J Wiley S Bliss

Lighting Suggestions for Accessible Kitchens

Lighting levels should be up to twice normal levels. Using light-colored floors, walls, ceilings, and counters will help keep all areas well illuminated. Light colors on the insides of cabinets and drawers will help make items more visible.

Also see Task Lighting, Definition , Uses

and Kitchen Lighting Requirements.

Cooking Work Center Suggestions for Accessible Kitchens

If possible, place the cooktop and sink on the same wall so users do not have to carry heavy pots across the room. Electric cooktops with a smooth surface and controls on the front work best so the user does not have to reach over the top. Look for units with staggered burners for easier access to back burners.

Use a separate wall-mounted oven, not an under-counter design. An oven with a side-hinged door rather than the usual pull-down style works well.

Refrigerator Work Center Design for Accessible Kitchens

Side-by-side units with doors that swing back a full 180 degrees are preferable to up-and-down models. Provide at least 18 inches of counter space adjacent to the refrigerator.

- - Adapted with permission from Best Practices Guide to Residential Construction (Steve Bliss, J Wiley & Sons) . This article includes excerpts or adaptations from Best Practices Guide to Residential Construction (Steve Bliss, J Wiley & Sons) , by Steven Bliss, courtesy of Wiley & Sons.

Accessible Kitchen Design Suggestions for Motorized Wheelchair Access

Below in the article references section we provide a DOJ article that gives a high-level gloss on the topic of meeting the accessibility requirements for people using a power-driven motorized device - a concept more broad than only motorized wheelchairs.

Here we will collect specific suggestions for kitchen designs that need to accomodate not simply wheelchair access, but motorized wheelchair access.

Even within the category of motorized wheelchairs and excluding other power-driven mobility devices such as Segways®, motorized wheelchairs vary in dimensions, weight, speed, and turning radius as well as operating controls.

If you have additional motorized wheelchair accessibility design suggestions and/or detailed specifications, or examples of designs that work well, please CONTACT US.

Power WheelChair Feature Turning Space Comparisons

Drive Mode Turning Circumference / Radius Weight Comment
Front Wheel Drive Medium

50 - 250 lbs.

20 - 120 Kilos

Long back end makes turning difficult in tight spaces

Front short endmakes turning tight corners easier

Mid-Wheel Drive Smallest

May be able to turn within a circle with diameter equal to the chair length

Rear Wheel Drive Largest  

Notes to the table:

Footrest position and design add to length of chair and thus impact turning radius

Source: includes Comparison of Front, Mid and Rear Wheel Drive Power Chairs, [PDF] cited in detail below.

...

References / Resources: ADA-Compliant Accessible Kitchens & Baths

 




ADVERTISEMENT





Reader Comments, Questions & Answers About The Article Above

Below you will find questions and answers previously posted on this page at its page bottom reader comment box.

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs

On 2021-05-25 by (mod) - ADA-Compliant drawer-pulls & cabinet door handles include foot-operated "handles" or Pulls

ADA-Compliant door or cabinet pull that can be foot or hand-opeated: the DoorWave by Functional Form LLC cited & discussed at InspectApedia.com

@alain smithee,

Thank you for that additional suggestions: ADA-approved cabinet and drawer pulls.

Typical ADA cabinet and drawer pulls are a bar raised off of the cabinet or drawer face - I'll show those in a moment. But first, here is an interesting product, shown above:

DoorWave™ by Functional Form, LLC is a hands-free door pull that allows you to open the door with your foot, sold by https://www.ameraproducts.com/ and other vendors.


Shown below are are more-typical ADA-compliant cabinet door or drawer pulls, sold just about everywhere including at building suppliers like Lowes and Home Depot

ADA-compliant drawer pulls and cabinet door handles cited at InspectApedia.com

On 2021-05-25 by alain smithee

I've seen upper cabinet and lower door pulls mounted at a 45-degee angle to make them easier to grasp for an individual with arthritis. This also made it easier to open the cabinet or door using a spoon as a lever,

On 2018-09-22 by (mod) - minimum turning space and typical dimensions for powered wheelchairs

Donna,

I'm researching the question further and; I've posted some additional information in the article above on this page and in a reader Q&A answered earlier (seen below) - you may need to clear your browser cache or wait a few hours to see the update; I'd welcome specific technical questions as well.

In general for an electric wheelchair, scooter, or reclining wheelchair users we need more turning space of these minimum dimensions:

On 2018-09-21 by Donna

I, like Wayne, am looking for kitchen specifications for a motorized wheelchair as opposed to a manual wheelchair. Have you made any progress in this area?

On 2018-04-30 by (mod)

If you have a specific question you're welcome to ask here and we'll do our best to answer. If you need an accessible design architect or builder - contractor then of course you'll need to find a local expert.

On 2018-04-30 by julia

need help

On 2016-10-10 by (mod) - ADA space and turning area dimensions for motorized wheelchairs & wheelchair platform lifts

Thanks for the good question, Wayne.

Using 33" as a typical height from floor to top of joystick for a power wheelchair, that's 3" higher than a conventional adult wheelchair (30" from floor to top surface of arm rest).

I used the Invacare® Pronto® M41™ Power Wheelchair as the power wheelchair example.

I looked at the specifications for several elevating wheelchair models but none provided a height from armrest or joystick top to floor. Can you give me that dimension for the brand and model chair that interests you?

Good point about the dishwasher. Looking at the U.S. ADA updates last completed in 2010:

Your point is of crucial importance to wheelchair users with all wheelchair types. I'm researching further.

On 2016-10-09 by Wayne Duke

It appears your design is for manual chairs only. Have you done any work related to power wheelchairs with elevator?
It is difficult to get under counters so low. Elevated foot plates look to need a minimum of 18" vertical clearance instead of the 9" you reference.

Also unable to reach down to access dishwasher at standard height.
Thanks for any help.
Wayne

Question:

(June 7, 2012) kay said:
I thought I would need to think about this redo in about 10 years. Things changed for me in I step. This is important for everyone to think about.

Reply:

(Feb 2, 2013) Anonymous said:
i remodeled my grandmother's house and added a 2d bath with a wide door, as the 'main bath door was just 18". i was planning for my mom. Overnight, my daughter needed it--fer several years. I dont see hmes the same way anymore.


...

Continue reading at KITCHEN CABINET DESIGN Guide or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

KITCHEN DESIGN, ACCESSIBLE at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to BATH & KITCHEN

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT