ROOFING INSPECTION & REPAIR
ALUMINUM ROOFING
AMERICAN CEMWOOD ROOFING
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS CEMENT & FIBER CEMENT ROOFING
ASBESTOS MATERIAL REGULATIONS
ASBESTOS REGULATION Update
ASPHALT ROOF SHINGLES
ATTIC LEAKS, CONDENSATION & MOLD
ATTIC VENTILATION

BEST ROOFING PRACTICES
BUILDING SAFETY HAZARDS GUIDE
BUILT UP ROOFS

CEMWOOD ROOFING
CERTIFICATIONS for ROOFING CONTRACTORS
CHIMNEY INSPECTION & REPAIRS
CHOOSING A ROOFING CONTRACTOR
CLAY TILE ROOFING
COLD WEATHER ROOF TROUBLE

CONCRETE ROOFING
CORRUGATED ROOFING
COPPER ROOFING
DEBRIS STAINING on ROOFS

DECKS, ROOFTOP CONSTRUCTION
DEFINITIONS of ENGINEERED WOOD OSB LVL etc
DISASTERS: BUILDING INSPECTION & REPAIR SAFEY

EARLY ROOF FAILURE DIAGNOSTIC QUESTIONS
EARLY ROOF FAILURE DIAGNOSTIC QUESTIONS
ENERGY SAVINGS in buildings
EPDM ROOFS
EXTRACTIVE BLEEDING on SHINGLES

FELT UNDERLAYMENT REQUIREMENTS
FIBER CEMENT & FIBERBOARD ROOFING
FIRE RATINGS for ROOF SURFACES
FIRE RETARDANT PLYWOOD
FLASHING, ASPHALT SHINGLE VALLEYS
FLASHING, CLAY TILE ROOFS
FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WOOD ROOF DETAILS
FLAT ROOF MOISTURE & CONDENSATION

GUTTERS & DOWNSPOUTS

HEAT TAPES & CABLES on Roofs for Ice Dams

ICE DAM PREVENTION
INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT

LEAD POISONING HAZARDS GUIDE
LEAKY ROOF DIAGNOSIS & REPAIR
LEED GREEN BUILDING CERTIFICATION
LOW SLOPE ROOFING

MASONITE WOODRUF FIBERBOARD ROOFING
MEMBRANE & SINGLE PLY ROOFS
METAL ROOFING
MODIFIED BITUMEN ROOFING

NOISE / SOUND DIAGNOSIS & CURE
NOISE CONTROL for ROOFS

PLASTIC ROOFING TYPES

ROLL ROOFING, ASPHALT
ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF COLOR RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOF INSPECTION SAFETY & LIMITS
ROOF JOB PROBLEMS, RESOLVING
ROOF LEAK DIAGNOSIS & REPAIR
ROOF NOISE TRANSMISSION
ROOF REPLACEMENT SNAFUs
ROOF SLOPE DEFINITIONS
ROOF VENTILATION SPECIFICATIONS
ROOFING FELT UNDERLAYMENT REQUIREMENTS
ROOFING MATERIALS, Age, Types
ROOFING TILE SHAPES & PROFILES
ROOFING UNDERLAYMENT BEST PRACTICES

SADDLE CONSTRUCTION at CHIMNEYS
SLATE ROOF INSPECTION & REPAIR
SNOW GUARDS on SLATE & METAL ROOFS
SOD ROOFING
SOUND CONTROL in buildings
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STANDARDS for ROOFING
STONE CLEANING METHODS
STONE ROOFING
STRESS SKIN INSULATED PANELS

TEST LABS - ROOF SHINGLE
THATCH ROOFING
THERMAL EXPANSION of MATERIALS
THERMAL MASS in buildings
TILE ROOFING
TREES & SHRUBS, TRIM OFF BUILDING
TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

UNDERLAYMENT REQUIREMENTS on ROOFS

VENTILATION in buildings

WALK-ON ROOF SURFACES
WARRANTIES for ROOF SHINGLES
WATER ENTRY in buildings
WIND DAMAGE to ROOFS
WINTERIZE A BUILDING
WOOD SHAKE & SHINGLE ROOFING
WORKMANSHIP & ROOF DAMAGE

ZINC METAL ROOFING

More Information

EPDM or membrane roof (C) Daniel Friedman Walk-On or "Walkable
Roofing Types, Product Sources, Installation, Defects, Repairs
InspectAPedia®  -      

  • Membrane roof materials
  • Definition of Membrane roofing
  • Types of Membrane roofs
  • EPDM roofs, Rubber Roofs, Modified Bitumen Roofs
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

This article describes sources and types of walk-on roof surface roofing materials, systems, installation suggestions, and product sources.

Also see DECKS, ROOFTOP CONSTRUCTION.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Walkable Roof Surfaces - Design, Product Sources, Installation

(Contributions, critique, corrections are invited: CONTACT us.)

Carson Dunlop's illustrations (below) compare an EPDM roof membrane installation and a PVC roof membrane installation.

Roll Roofing Problems (C) Carson Dunlop AssociatesRoll Roofing Problems (C) Carson Dunlop Associates

Materials & Installation Advice for Walkable Roofing Membranes

As explained in Best Practices Guide to Residential Construction, chapter on BEST ROOFING PRACTICES:

For rooftops that will also serve as decks (see “Rooftop Decks,” [online version coming] page 150 in the printed text Best Practices Guide to Residential Construction), one option is to use a roofing material designed for foot traffic.

Duradek (Duradek U.S. Inc.) is a sheet vinyl membrane similar to Hypalon but with a nonskid wear surface. It was developed over 25 years ago for waterproofing decks, balconies, and outdoor living spaces. For use over a living space, the manufacturer recommends its 60-mil Ultra series, which is warranted against leakage for 10 years.

Duradek is made of reinforced PVC sheet with heat stabilizers and additives for resistance to fire, UV degradation, and mildew. The wear surface is textured for slip resistance and available in a variety of colors.

Installation Tips for Walk-On Roofs

Installation is similar to other single plies and must be done by factory-certified contractors. The membrane glues to almost any clean substrate with either a proprietary contact cement or a special water-based adhesive applied with a notched trowel. Seams are heat welded with a heat gun, the most critical step. Like other single-ply membranes, the material is self-flashing at abutting walls and penetrations.

Pros and Cons of Duradek Walkable Roofing Membranes

Duradek creates an attractive and durable no-skid deck surface that can withstand normal wear and tear, direct sun exposure, high winds, and freeze-thaw cycles. However, because the membrane is also the wear surface, it can be damaged by cigarette burns, punctures, and heavy abrasion.

-- Adapted with permission from Best Practices Guide to Residential Construction.

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ROOFING INSPECTION & REPAIR
CEMWOOD ROOFING
CERTIFICATIONS for ROOFING CONTRACTORS
CHOOSING A ROOFING CONTRACTOR
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS CEMENT & FIBER CEMENT ROOFING
ASPHALT ROOF SHINGLES
ATTIC CONDENSATION CAUSE & CURE
BEST ROOFING PRACTICES
BUILDING SAFETY HAZARDS GUIDE
BUILT UP ROOFS

CEMWOOD ROOFING
CERTIFICATIONS for ROOFING CONTRACTORS
CHIMNEY INSPECTION & REPAIRS
CHOOSING A ROOFING CONTRACTOR
CLAY TILE ROOFING
CLAY, CONCRETE, FIBER CEMENT ROOF TILES
COOLING LOAD REDUCTION by ROOF VENTS
FELT UNDERLAYMENT REQUIREMENTS
FIBER CEMENT & FIBERBOARD ROOFING
FIRE RATINGS for ROOF SURFACES
FIRE RETARDANT PLYWOOD
FLASHING, ASPHALT SHINGLE VALLEYS
FLASHING, CLAY TILE ROOFS
FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WOOD ROOF DETAILS
FLAT ROOF MOISTURE & CONDENSATION

GALVANIC SCALE & METAL CORROSION
Green House or Solarium Roof Leaks
GUTTERS & DOWNSPOUTS

HAIL DAMAGED SHINGLES
HEAT TAPES & CABLES on Roofs for Ice Dams
HOT ROOF DESIGNS: Un-Vented Roof Solutions
HOUSEWRAP INSTALLATION DETAILS
HUMIDITY LEVEL TARGET

ICE DAM PREVENTION
INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT

LEAD POISONING HAZARDS GUIDE
LEAKY ROOF DIAGNOSIS & REPAIR
LEED GREEN BUILDING CERTIFICATION
LOW SLOPE ROOFING

MASONITE WOODRUF FIBERBOARD ROOFING
MEMBRANE & SINGLE PLY ROOFS
METAL ROOFING
MODIFIED BITUMEN ROOFING

NOISE / SOUND DIAGNOSIS & CURE
NOISE CONTROL for ROOFS

PLASTIC ROOFING TYPES
ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF COLOR RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOF INSPECTION SAFETY & LIMITS
ROOF VENTILATION SPECIFICATIONS
ROOF VENTING ENERGY SAVING DETAILS
ROOFING FELT UNDERLAYMENT REQUIREMENTS
ROOFING MATERIALS, Age, Types
ROOF NOISE TRANSMISSION
ROOFING TILE SHAPES & PROFILES
ROOFING UNDERLAYMENT BEST PRACTICES
SLATE ROOF INSPECTION & REPAIR
SNOW GUARDS on SLATE & METAL ROOFS
SOD ROOFING
SIDING, Sheathing Identification - Photo Guide

STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STANDARDS for ROOFING
STONE CLEANING METHODS
STONE ROOFING

TEST LABS - ROOF SHINGLE
THATCH ROOFING
THERMAL EXPANSION of MATERIALS
THERMAL MASS in buildings
TILE ROOFING
TREES & SHRUBS, TRIM OFF BUILDING
TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

UNDERLAYMENT REQUIREMENTS on ROOFS

WALK-ON ROOF SURFACES
WARRANTIES for ROOF SHINGLES
WOOD SHAKE & SHINGLE ROOFING
WORKMANSHIP & WIND DAMAGE
ZINC METAL ROOFING

  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. Thanks to Alan Carson and Bob Dunlop, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education including the ASHI-adopted Home Inspection Training Program (home study course), publications such as the Home Reference Book, report writing materials including the Horizon report writer, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
  • "Choosing Roofing," Jefferson Kolle, January 1995, No. 92, Fine Homebuilding, Taunton Press, 63 S. Main St., PO Box 5506, Newton CT 06470 - 800-888-8286 - see http://www.taunton.com/FineHomebuilding/ for the magazine's website and for subscription information.
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
  • Problems in Roofing Design, B. Harrison McCampbell, Butterworth Heineman, 1991 ISBN 0-7506-9162-X (available used)

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson Dunlop The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop. The Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  • The Journal of Light Construction has generously given reprint permission to InspectAPedia.com for this article. All rights and contents are ©Journal of Light Construction and may not be reproduced in any form.
  • Asphalt Roofing Residential Manual,
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • Concrete Folded Plate Roofs, C. Wilby PhD BSc CEng FICE FIStructE (Author), Butterworth-Heinemann, 1998, ISBN-10: 0340662662, ISBN-13: 978-0340662663
  • Concrete Shell Roofs, C. Wilby PhD BSc CEng FICE FIStructE (Author),
  • Concrete Dome Roofs (Longman Concrete Design and Construction Series),
  • Green Roof Plants: A Resource and Planting Guide, Edmund C. Snodgrass, Lucie L. Snodgrass, Timber Press, Incorporated, 2006, ISBN-10: 0881927872, ISBN-13: 978-0881927870. The text covers moisture needs, heat tolerance, hardiness, bloom color, foliage characteristics, and height of 350 species and cultivars.
  • Green Roof Construction and Maintenance, Kelley Luckett, McGraw-Hill Professional, 2009, ISBN-10: 007160880X, ISBN-13: 978-0071608800, quoting: Key questions to ask at each stage of the green building process Tested tips and techniques for successful structural design Construction methods for new and existing buildings Information on insulation, drainage, detailing, irrigation, and plant selection Details on optimal soil formulation Illustrations featuring various stages of construction Best practices for green roof maintenance A survey of environmental benefits, including evapo-transpiration, storm-water management, habitat restoration, and improvement of air quality Tips on the LEED design and certification process Considerations for assessing return on investment Color photographs of successfully installed green roofs Useful checklists, tables, and charts
  • Handbook of Building Crafts in Conservation, Jack Bower, Ed., Van Nostrand Reinhold Company, NY 1981 ISBN 0-442-2135-3 Library of Congress Catalog Card Nr. 81-50643.
  • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
  • Historic Slate Roofs : With How-to Info and Specifications, Tina Skinner (Ed), Schiffer Publishing, 2008, ISBN-10: 0764330012 , ISBN-13: 978-0764330018
  • Low Slope Roofing, Manual of, 4th Ed., C.W. Griffin, Richard Fricklas, McGraw-Hill Professional; 4 edition, 2006, ISBN-10: 007145828X, ISBN-13: 978-0071458283
    • Roof failure causes in depth (and specific methods for avoiding them)
    • Roof design fundamentals and flourishes, based on voluminous industry research and experience
    • New technologies and materials -- using them safely and correctly
    • Comprehensive coverage of all major roofing systems pecifications, inspection, and maintenance tools for roofing work
  • Problems in Roofing Design, B. Harrison McCampbell, Butterworth Heineman, 1991 ISBN 0-7506-9162-X (available used)
  • Roofing The Right Way, Steven Bolt, McGraw-Hill Professional; 3rd Ed (1996), ISBN-10: 0070066507, ISBN-13: 978-0070066502
  • Slate Roofs, National Slate Association, 1926, reprinted 1977 by Vermont Structural Slate Co., Inc., Fair Haven, VT 05743, 802-265-4933/34. (We recommend this book if you can find it. It has gone in and out of print on occasion.)
  • The Slate Roof Bible, Joseph Jenkins, www.jenkinsslate.com, 143 Forest Lane, PO Box 607, Grove City, PA 16127 - 866-641-7141 (We recommend this book).
  • Slate Roofing in Canada (Studi4es in archaeology, architecture, and history),
  • Smart Guide: Roofing: Step-by-Step Projects, Creative Homeowner (Ed), 2004, ISBN-10: 1580111491, ISBN-13: 978-1580111492
  • Tile Roofs of Alfred: A Clay Tradition in Alfred NY
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • Wood Shingle Roofs, Care and Maintenance of wood shingle and shake roofs (EC), Stanley S. Niemiec (out of print)
  • ...

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com