Mobile ViewAIR CONDITIONING & HEAT PUMP SYSTEMS AIR BYPASS LEAKS AIR LEAK DETECTION TOOLS AIR LEAK MINIMIZATION AIR POLLUTANTS, COMMON INDOOR AIR LEAK SEALING PROCEDURE AIR SEALING STRATEGIES BASEMENT CEILING VAPOR BARRIER BASEMENT HEAT LOSS BIOGAS PRODUCTION & USE BLOWER DOORS & AIR INFILTRATION BLOWER FAN CONTINUOUS OPERATION BLOWER FAN OPERATION & TESTING BLOWN-IN INSULATION BRICK LINED WALLS BRICK VENEER WALL INSULATION BRICK VENEER WALL Loose, Bulged BRICK WALL DRAINAGE WEEP HOLES BUCKLED FOUNDATIONS due to INSULATION? BUILDING NOISE DIAGNOSIS & CURE CATHEDRAL CEILING INSULATION CATHEDRAL CEILING VENTILATION CATHEDRAL CEILING INSULATION CATHEDRAL CEILING VENTILATION CEILING FINISHES INTERIOR CEILINGS, DROP or SUSPENDED PANEL CEILINGS, PLASTER TYPES CHIMNEY INSPECTION DIAGNOSIS & REPAIR COOLING LOAD REDUCTION by ROOF VENTS COMBUSTION AIR for TIGHT BUILDINGS CONDENSING BOILERS/FURNACES DAMAGE CONDENSATION or SWEATING PIPES, TANKS COOLING LOAD REDUCTION by ROOF VENTS CRAWL SPACES DEHUMIDIFICATION PROBLEMS DEW POINT CALCULATION for WALLS DEW POINT TABLE - CONDENSATION POINT GUIDE ENERGY SAVINGS in buildings AFUE DEFINITION, RATINGS AIR BYPASS LEAKS AIR CHANGE RATE ACH HEAT SAVINGS AIR CONDITIONING HEAT PUMP SAVINGS AIR LEAK SEALING PROCEDURE APPLIANCE EFFICIENCY RATINGS ATTIC LEAKS, CONDENSATION & ATTIC MOLD COOLING LOAD REDUCTION by ROOF VENTS ENERGY AUDIT - How to Use a Free One ENERGY SAVINGS MAXIMIZE RETURNS ON ENERGY SAVINGS PRIORITIES ENERGY SAVINGS RETROFIT CASE STUDY ENERGY SAVINGS RETROFIT LEAK SEALING GUIDE ENERGY SAVINGS RETROFIT OPTIONS ENERGY STAR PROGRAM ENERGY USE MONITORING GLASS vs HEAT MIRROR SOLAR GAIN/Loss HEAT LOSS in buildings HEATING COST SAVINGS METHODS HIGH MASS TRADEOFFS, HEATING vs COOLING HOUSE DOCTOR, how-to be INSULATION INSPECTION & IMPROVEMENT INSULATION LOCATION - WHERE TO PUT IT RADIANT BARRIERS REFLECTIVE INSULATION ROOF COLOR RECOMMENDATIONS Skylight Energy Efficiency SOLAR ENERGY SYSTEMS THERMAL MASS in buildings TIMERS for ELECTRIC WATER HEATERS VENTILATION, BALANCED HEAT COST SAVINGS WIND ENERGY SYSTEMS WINDOW EFFICIENCY Features & Ratings WOOD, COAL STOVES & FIREPLACES EVAPORATIVE COOLING SYSTEMS EXTERIORS of buildings FRAMING DETAILS for BETTER INSULATION FRAMING DETAILS for DOUBLE WALL HOUSES FRAMING METAL STUD PERFORMANCE FREEZE-PROOF A BUILDING FROST HEAVES, FOUNDATION, SLAB GREEN BUILDING CONSTRUCTION CODES GUIDES GREENHOUSE DESIGN for SOLAR HEATING GREENHOUSE / SUNSPACE GLARE HEAT LOSS in BUILDINGS HEAT LOSS RATE CALCULATIONS HEAT LOSS DETECTION TOOLS HEAT LOSS INDICATORS HEAT LOSS PREVENTION PRIORITIES HEAT LOSS R U & K VALUE CALCULATION HOT ROOF DESIGNS: Un-Vented Roof Solutions HOUSEWRAP AIR & VAPOR BARRIERS HOUSE DOCTOR, how-to be HUMIDITY LEVEL TARGET ICE DAM PREVENTION INDOOR AIR QUALITY & HOUSE TIGHTNESS INSULATION IDENTIFICATION GUIDE INSULATION INSPECTION & IMPROVEMENT FOOTING & FOUNDATION DRAINS FOUNDATION CRACKS & DAMAGE GUIDE BUCKLED FOUNDATIONS due to INSULATION? HEATING SMALL LOADS INDOOR AIR QUALITY & HOUSE TIGHTNESS INSULATION IDENTIFICATION GUIDE INSULATION INSPECTION & IMPROVEMENT INTERIORS of buildings LEED GREEN BUILDING CERTIFICATION LEED Building Designation & IAQ MOISTURE CONTROL in buildings Nanomaterials Hazards NOISE / SOUND DIAGNOSIS & CURE NOISE CONTROL for HEATING SYSTEMS NOISE CONTROL for FLOORS NOISE CONTROL for PLUMBING NOISE CONTROL for ROOFS ODORS & SMELLS DIAGNOSIS & CURE PLUMBING SYSTEM INSPECT DIAGNOSE REPAIR STRUCTURAL INSPECTIONS & DEFECTS HEATING SYSTEMS COMBUSTION AIR for TIGHT buildings HEATING SMALL LOADS RADIANT HEAT RADIANT HEAT Floor Mistakes to Avoid RADIANT HEAT TEMPERATURES RADIANT SLAB FLOORING CHOICES RADIANT SLAB TUBING & FLUID CHOICES ROOFING INSPECTION & REPAIR SHEATHING, FOIL FACED - VENTS SOLAR ENERGY SYSTEMS BLOCKBED RADIANT FLOORS - SOLAR DESIGN FLOOR, CONCRETE SLAB CHOICES FLOOR, CONCRETE SLAB POURED FINISH GLASS vs HEAT MIRROR SOLAR GAIN/Loss GREENHOUSE DESIGN for SOLAR HEATING GREENHOUSE / SUNSPACE GLARE PASSIVE SOLAR DESIGN KEY ELEMENTS PASSIVE SOLAR DESIGN METHOD PASSIVE SOLAR ENERGY MONITORING PASSIVE SOLAR FLOOR TILES, PHASE CHANGE PASSIVE SOLAR HEAT PERFORMANCE PASSIVE SOLAR HOME, LOW COST PASSIVE SOLAR PERFORMANCE PROBE PASSIVE SOLAR Roof & Window Overhangs PHOTOVOLTAIC POWER SYSTEMS POLYCARBONATE GLAZING REMOTE ELECTRIC POWER, PHOTOVOLTAIC ROCK-BED SOLAR HEAT STORAGE DESIGN SLAB INSULATION, PASSIVE SOLAR SLATE THERMAL MASS for SOLAR HEAT STORAGE SOLAR COLLECTOR AIR or GAS COLLECTION SOLAR COLLECTOR EFFICIENCY COMPARISONS SOLAR COLLECTOR FILMS SOLAR COLLECTOR OUTGASSING SOLAR COLLECTOR WOOD HOUSINGS SOLAR GAIN CALCULATION SOLAR HEATING SYSTEM DESIGNS SOLAR HOT WATER HEATERS SOLAR HOUSE EVALUATION SOLAR MODULE MANUFACTURERS SOLAR SHADES & SUNSCREENS SOLAR SHADES, LOW-E EFFECTIVENESS SOLAR WATER DISINFECTION SOLAR HOT WATER HEATERS SUNSPACE DESIGN for SOLAR HEATING SUNSPACE GLAZING for SUNTANNING STORM WINDOW INTERIOR STORM WINDOW PLASTIC CHOICES STORM WINDOW WEEP HOLES SUNGAIN, FILMS, LOW-E GLASS SUNSPACE GLAZING for SUNTANNING SWIMMING POOL SOLAR HEAT, INDOOR SWIMMING POOL SOLAR HEAT, OUTDOOR DIAGNOSIS STRUCTURAL INSPECTIONS & DEFECTS SUMP PUMPS GUIDE SWEATING (CONDENSATION) on PIPES, TANKS THERMAL EXPANSION of MATERIALS THERMAL MASS in buildings THERMAL MASS FLOOR SLABS THERMAL MASS in UPSTAIRS THERMAL MASS WALL DESIGN THERMAL MASS in HOMES - STUDY THERMAL MASS TRADEOFFS, HEATING vs COOLING THERMAL TRACKING & HEAT LOSS VAPOR BARRIERS & CONDENSATION in buildings ATTIC CONDENSATION CAUSE & CURE BASEMENT CEILING VAPOR BARRIER CONDENSATION or SWEATING PIPES, TANKS CRAWL SPACE VAPOR BARRIER DEW POINT CALCULATION for WALLS DEW POINT TABLE - CONDENSATION POINT GUIDE FELT 15# ROOFING, as HOUSEWRAP/VAPOR BARRIER HOUSEWRAP AIR & VAPOR BARRIERS HOUSEWRAP INSTALLATION DETAILS HOUSEWRAP PRODUCT CHOICES HOUSEWRAP at SILLS, SOLES, TOP PLATES HUMIDITY LEVEL TARGET MOISTURE CONTROL in buildings RAIN SPLASH-UP SIDING DAMAGE VAPOR BARRIERS & AIR SEALING at BAND JOISTS VAPOR BARRIERS & CONDENSATION in buildings VAPOR BARRIERS & HOUSEWRAP VAPOR CONDENSATION & BUILDING SHEATHING WATER BARRIERS, EXTERIOR WOOD SIDING FLASHING DETAILS VENTILATION in buildings WATER HEATERS AGE of WATER HEATERS ALTERNATIVE HOT WATER SOURCES WATER SOFTENERS & CONDITIONERS WATER ENTRY in buildings WIND ENERGY SYSTEMS WIND TURBINES & LIGHTNING WIND WASHING INSULATION At EAVES WINDOWS & DOORS ALUMINUM WINDOWS Best Practices Guide for Windows & Doors: CLIMATE, WINDOW CHOICES FOR CONDENSATION on WINDOWS & SKYLIGHTS Doors, Exterior, Energy Efficiency Guide Doors, Exterior Flashing Details Doors, Exterior, Frames DOORS, EXTERIOR, Selecting & Installing DOORS, INTERIOR FIBERGLASS WINDOWS GLASS vs HEAT MIRROR SOLAR GAIN/Loss HURRICANE, WIND, & STORM-Resistant WINDOWS LOW-E WINDOW GLAZING LOW-E VS QUAD-GLAZING LOW-E RETROFIT ADD-ON FILMS POLYCARBONATE GLAZING SITE BUILT DOUBLE GLAZED WINDOWS SKYLIGHTS, Guide to Choosing & Installing Skylight Condensation Problems Skylight Window Design Issues Skylight Energy Efficiency Skylight Installation Procedures SKYLIGHT LEAK DIAGNOSIS & REPAIR SKYLIGHT VENTILATION DETAILS SLIDING GLIDING WINDOW DEFECTS SLOPED GLAZING DETAILS STORM WINDOW INTERIOR STORM WINDOW PLASTIC CHOICES STORM WINDOW WEEP HOLES SUNGAIN, FILMS, LOW-E GLASS SUNSPACE GLAZING for SUNTANNING VERTICAL GLAZING DETAILS VINYL WINDOWS VINYL / PVC WINDOW WARPING WINDOW / DOOR ENERGY EFFICIENT, DOE WINDOW / DOOR AIR LEAK SEALING HOW TO Window Certification WINDOW EFFICIENCY Features & Ratings Window Flashing & Sealing Guide WINDOW HARDWARE PHOTOS Window Installation, Flange-Type Window Installation, w/ Integral Brickmold WINDOW LEAKS INTO BASEMENT Window Materials & Construction Window Types, Guide WINDOW TYPES - Photo Guide Window & Door Sources WINTERIZE A BUILDING Wood Burning Heaters Fireplaces Stoves Woodstove Safety ZONE VALVES More Information |
This article discusses the durability of and advice on construction of solar collector housings made of wood, plywood, or OSB. Sketch at page top and accompanying text are reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. Contact us to suggest text changes and additions and, if you wish, to receive online listing and credit for that contribution. © Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Durability of Wood Housings for Solar Collectors"Wood in [solar] collectors" - links to the original article in PDF form immediately below are followed by an expanded/updated online version of this article
The question-and-answer article about the durability of wood for use in constructing the housing of solar collectors, quotes-from, updates, and comments an original article, (see links just above) from Solar Age Magazine and written by Steven Bliss. Question about the structural integrity of wood frames or housings for solar collectorsIn the near future I intend to construct flat-plate solar collectors for use in a hot air heating system. I would like to construct the collector structure out of wood, using commonly available materials such as pines, plywood, or waferboard (OSB). Can I expect the wood solar collector frame to maintain its structural integrity under the high heat conditions? Is there any danger of fire? - L.P_.C. - Methuen MA Answer: By the mid 1980's in the U.S., the use of wood in solar collector housings or frames had been questioned and investigated by a number of parties, particularly because of a high level of consumer interest in build-your-own solar collector projects following the spike in home heating oil prices. The consensus on use of wood to build a solar collector seems to be: use caution or avoid the use of wood altogether. The degradation of wood under long term exposure to high temperatures (for example by chemical change or pyrolosis) has been well documented. The degradation is a function of temperature and time and is cumulative from one high temperature exposure to the next. Most researchers feel that degradation of wood is insignificant below 200 degF. Long term exposure of wood to temperatures from 200 degF. to 300 deg.F. will cause the wood to lose weight and strength, and under some conditions the wood will actually char. Can a wooden solar collector catch fire? Wood charring in response to these high temperatures is caused by a slow glowing combustion process (pyrolosis) that is exothermic, or heat-producing. If this heat is trapped and temperatures sufficiently elevated, flaming combustion could occur. [This is why a heating system flue that is too close to wooden building framing becomes a fire hazard and can eventually begin to actually burn - pyrolosis reduces the ignition point of the wood - see Fire Clearances, Single-Wall Metal Flues and also Wood & Coal Stove Flues for details -- DF.] Specific design temperatures for wood-framed solar collectors are not available since many variables determine the ignition point of wood. In tests conducted by the U.S. Department of Energy (DOE), charring of plywood solar collector backings was observed after one summer of stagnation in test collectors with peak temperatures of 290 degF. Plywood and waferboard (or OSB, oriented strand board) pose no greater problems than solid wood, since the phenolic adhesives used are unaffected at these temperatures. The goal in constructing a wood-based solar collector structure, then, is to keep wood temperatures low by insulating the wood, keeping the wood from touching the solar absorber, and avoiding high-temperature stagnation conditions. Low-temperature single-glazed solar collectors with summer venting would be in order. [This is not a new topic, and a full discussion of the issue of solar collector durability appeared in Solar Age Magazine, 8/81 p. 42.] Here we include solar energy, solar heating, solar hot water, and related building energy efficiency improvement articles reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss. Questions & Answers regarding this article. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. SOLAR ENERGY SYSTEMS
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
|
| Home | About Us | Accuracy | Contact Us | Content Use Policy | Privacy | Website Description | © 2012 Copyright InspectAPedia.com |