InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • DAMAGE ASSESSMENT
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



InspectAPedia ® Home

EXTERIORS of buildings

ALGAE, FUNGUS, LICHENS, MOSS
ART CONSERVATION - Cultural Heritage and Aerobiology
ARTWORK MOLD CONTAMINATION

BOOKSTORE - EXTERIORS

CAULKS & SEALANTS, EXTERIOR

DECK FINISHES COATINGS PRESERVATIVES

EIFS & STUCCO EXTERIORS
EXTERIOR WALL SIDING TRIM & FINISHES

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP

LEAD POISONING HAZARDS GUIDE
LEAD PAINT REMOVAL ALTERNATIVES
LEAD PAINT REMOVAL TROUBLES

PAINT & STAIN GUIDE, EXTERIOR

SLIDE PREPARATION, MICROSCOPE
STAIN & BIODETERIORATION AGENT CATALOG
STAINS on & in BUILDINGS, CAUSES & CURES
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAINS & FINISHES, INTERIOR
STUCCO PAINT FAILURES

TEST KITS for DUST, MOLD, PARTICLE TESTS
TRIM, EXTERIOR CHOICES, INSTALLATION

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VINYL SIDING

WALL SIDING TRIM & FINISHES
WALL FINISHES INTERIOR

More Information

Paint failure investigation onsite (C) Daniel FriedmanPaint analysis in the lab (C) DanieL Friedman

Detailed Fee Schedule for Building Paint Failure Onsite Investigations & Laboratory Analysis Services
     

  • Paint sample test fee schedule
  • Questions & Answers about the alternatives & costs of methods of analysis of samples of paint for purposes of identification or failure analysis
  • References

Click to Show or Hide Related Topics

  • PAINT FALURE, DIAGNOSIS, CURE, PREVENTION - home
  • PAINT & STAIN GUIDE, EXTERIOR
  • PAINT / STAIN SELECTION & PROCEDURES
  • PAINT & STAIN LIFE CHART
  • PAINT & STAIN SELECTION & PROCEDURES
  • PAINT ANALYSIS, DIAGNOSTIC USES & PAINT ANALYSIS COSTS
  • PAINT FAILURE ANALYSIS
    • Chemical Tests of Failing Paint
    • Paint Failure Case Photographs-SITE
    • Paint Failure Case Photographs-LAB
    • PAINT LAB SAMPLE PREPARATION
    • Sectional View of Failing Paint
  • PAINT FAILURE DICTIONARY
  • PAINT FAILURE INDICATORS
    • PAINT FAILURE - EXTERIOR CLUES
    • PAINT FAILURE - INTERIOR CLUES
    • PAINT FAILURE - SITE HISTORY of
  • PAINT on STUCCO, FAILURES
  • PAINT SURFACE PREPARATION
  • PAINTING MISTAKES
    • BAD SURFACE PREP
    • INCOMPATIBLE PAINTS
    • PAINT on STUCCO, FAILURE
    • PAINTING SHORTCUT ERRORS
    • PAINTING OVER MOISTURE
    • PAINTING in SUN or WIND
  • VAPOR BARRIERS & CONDENSATION
  • WALL SIDING TRIM & FINISHES
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

This page outlines typical fees for on-site & laboratory paint failure investigations/testing. With offices in New York and Guanajuato, Mexico, we provide specialized forensic building diagnostic on-site and laboratory services throughout North America.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

Paint Test Lab Forensic Analysis Fees

Also see Diagnostic & Forensic Building Inspections, Tests, Fees

Paint Failure Investigations on-site

See our Paint Diagnosis Guide

$2750. + travel & lodging

Paint Laboratory Services

Extra or Mail-in Paint Chip Microscopic Analysis - See our Paint Lab Photos

 
Paint chip surface characterization: causes of failure including moisture
push, vs improper surface preparation (chalking, dirty, loose paint)
$50. per sample
Paint chip high magnification analysis: causes of failure including solvent blistering, thermal blistering - requires cross section analysis
$125. per sample
Paint layers: count, measure layer thickness, identify problems between
layers: causes of failure including surfactant leaching
$150. per sample

Chemical tests to attempt differentiation between oil/alkyd paints and
latex vs acrylic paints (some conditions produce uncertain results)

$200. per sample

Complete microscopic analysis of paint chip sample for all of the above
$250. per sample

Immediate Consulting by telephone:

Use this link: Immediate Consulting

Pro-bono professional assistance may be provided to elderly, disabled, limited-income individuals or for religious institutions.

Contact us & explain your pro-bono request.

Free Information: Find our free, researched, un-biased and in-depth building and environmental diagnosis & repair advice

InspectAPedia.com

Travel:

$85./hour + air fees if required

Paint Sample Chip Mailing Instructions:

After having corresponded with us by email to confirm just what analysis and services are needed, package individual paint chips in small hard containers or if in plastic bags, pack so as to protect further breakage of the paint chips into smaller fragments.

Payment Methods: We accept payment for services by check, credit card / PayPal, or cash, and we provide invoices for our services. Payment instructions and options, including how to make payments online are described at PAYMENT INSTRUCTIONS

MAIL-In PAINT CHIP SAMPLES: Send PAINT CHP SAMPLES, DOCUMENTATION, & PAYMENT TO

Daniel Friedman
Vassar College Box 419
124 Raymond Avenue
Poughkeepsie NY 12604

UPS / FEDEX / US Post Office EXPRESS MAIL Deliveries are accepted but -

PLEASE DO NOT REQUIRE A SIGNATURE on packages sent to the lab -- If using Express Mail sign the box used for Waiver of Signature. Failure to follow this suggestion will delay processing of your sample and may result in the sample being returned to you without processing. If you are using the U.S. Post Office's Express Mail be sure to check and sign the signature waiver box on the mailing label. Otherwise the postal carrier will not leave your sample at our lab drop box.

Future Consulting, No Fee. We do not bill for future consulting regarding services we have provided.

No Hidden Costs: Inspection fees and fees for other services will be reviewed with you and committed before any work is performed.
The fees in this table are subject to change without notice.

Are you paying too much or too little for a professional service? Is it possible to pay too little for a Building inspection? see John Ruskin's advice for a thoughtful answer to this question.

Daniel Friedman's Bio

   Building & Environmental Inspection & Testing Fees & Services

  • Environmental Inspections, Paint Failure Inspections, Tests, Fees - Indoor Air Quality, Mold, Gases, Odors, Bacterial Contamination
  • Diagnostic & Forensic Building Inspections, Tests, Fees - pre purchase inspections, diagnostic building inspections, forensic damage causation, repair advice. Home inspections are meet or exceed the ASHI Standards of Practice and Code of Ethics
  • No Conflicts of Interest: We do not work through realtor-referrals or other sources which might present conflicts of interest with those of our clients or readers.
  • Credentials & Experience: The inspector's experience and credentials and list of publications and classes are available online.
  • Payment Methods: We accept payment for services by check, credit card, PayPal, or cash, and we provide invoices for our services. Payment instructions and options, including how to make payments online are described at PAYMENT INSTRUCTIONS for Services Provided by Daniel Friedman - American Home Service Co.

Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about the alternatives & costs of methods of analysis of samples of paint for purposes of identification or failure analysis.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • ...

HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com