STRUCTURAL INSPECTIONS & DEFECTS

AGE of a BUILDING - how to determine
ARCHITECTURE & BUILDING COMPONENT ID

BEST CONSTRUCTION PRACTICES GUIDE
BOOKSTORE - INTERIORS
BUILDING NOISE DIAGNOSIS & CURE
BUILDING SAFETY HAZARDS GUIDE

CARPETING, SELECTION & INSTALLATION

DECK & PORCH CONSTRUCTION

ELDERLY & VETERANS HOME SAFETY

FRAMING DAMAGE, INSPECTION, REPAIR

HOME INSPECTION SAFETY HAZARDS

LIGHTING, EXTERIOR GUIDE
LIGHTING, INTERIOR GUIDE

MOBILE HOME INSPECTIONS

NOISE / SOUND DIAGNOSIS & CURE
NOISE CONTROL for FLOORS

ROT RESISTANT LUMBER

SAFETY HAZARDS & INSPECTIONS
SAFETY: Elderly & Veterans Home Safety
SAFETY for ELECTRICAL INSPECTORS
SOUND CONTROL in buildings
Splits in Structural Wood Beams
STAIRS, RAILINGS, LANDINGS, RAMPS

WOOD FLOOR DAMAGE

More Information

Fire blocking at stairwell (C) D Friedman Eric Galow Guide to Fire Stopping Requirements for Interior Stair Underside or Sidewalls Slow Fire Spread
     

  • Stair, railing, guardrail, landing, tread, and step fire spread prevention specifications & codes
  • Stair &stair construction fire blocking safety hazards, photos
  • Sketches of stair fire blocking and fire safety design requirements
  • Questions & Answers about building code specifications for fire blocking at steps and stairways
  • References

Click to Show or Hide Related Topics

  • STAIRS, RAILINGS, LANDINGS, RAMPS - home
  • ATTIC STAIRS
  • BALUSTERS, STAIR & RAILING
  • BALUSTER INSTALLATION
  • BARK SIDE UP on DECKS & STEPS
  • BASEMENT STAIRS & WALKOUT COVERS
  • BOOKS on STAIR CONSTRUCTION
  • CABLE RAILINGS & GUARDRAILS
  • CHECKLIST for STAIR INSPECTIONS
  • CIRCULAR & CURVED STAIRS
  • CODES for STAIRS
  • COLOR / LIGHTING CUES AVOID TRIP HAZARDS
  • DECK STAIR BUILDING START
  • DECK STAIR BUILDING DETAILS
  • DECK & PORCH GUARDRAILINGS
  • EXTERIOR STAIRS
  • FIRE STOPPING for STAIRWAYS
  • FRAMING TRIANGLES & CALCULATIONS
  • GRASPABILITY of HANDRAILINGS
  • GUARDRAILS on BALCONIES, DECKS, LANDINGS
  • HANDRAILS & HANDRAILINGS
  • LIGHTING OVER STAIRS
  • PET STAIRS, PET RAMPS
  • PLATFORMS & LANDINGS, ENTRY & STAIR
  • RAILINGS
  • RAILINGS, DECK & PORCH
  • RAMPS, ACCESS
  • SLIP TRIP & FALL HAZARD LIST, STAIRS
  • SLIPS , TRIPS & FALLS, EXTERIOR STAIRS
  • SLIPPERY STAIRS, WALKS
  • SNAG HAZARDS on STAIRWAYS
  • STAIR DIMENSIONS, WIDTH, HEIGHT
  • STAIR RAILS, STAIR GUARDS
  • STAIR RISE & RUN CALCULATIONS
  • STAIR HEADROOM
  • STEP RISER DIMENSIONS
  • STEP TREAD DIMENSIONS
  • STEP TREAD NOSE DIMENSIONS
  • STRINGER DEFECTS, STAIR
  • WINDER or ANGLED STAIRS
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Fire blocking or fire stopping at stairwells: codes / specification requirements for fire blocking at stairs and stairways: this document provides building code specifications, sketches, photographs, and examples of fire stopping or fire spread control for stairs and stairways. We also include references to key documents on building codes and stair and railing safety.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website

Fire Stopping or Fire Blocking Requirements at Steps & Stairways.

Stairway Lighting requirements (C) Carson Dunlop

Fire stopping for stairs is required to slow the spread of building fires between floors and to assist in emergency exit.

Sketch at left courtesy of Carson Dunlop Associates, illustrates where fireblocking must be installed.

For an interior stairway, 1/2" drywall is fastened to the stair underside or sidewalls above (if present) or (below) the stairs.

These improvements are not expected to make the building fire-proof. But especially because stairs form a natural building fire spread pathway fire stopping is required by building codes to slow the spread of fire that might follow the under-side of a stairway from a lower floor to an upper one.

Also see our page top photo. There you will notice that the under-side and sidewall of stairs passing through a garage were covered with fire-rated drywall on both the stair side and underside. Photo courtesy Galow Homes.

Model & Example California Building Code Specifications for Fire Blocking & Fire Stopping at Stairways

Example: California Building Code Stairways & Landings Specifications - stairway fire blocking / fire stopping

Enclosed useable space under stairs must be protected on the enclosed side by 5/8" type X gypsum wallboard. [37]


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about building code specifications for fire blocking at steps and stairways.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • Carson, Dunlop &
Associates Ltd., TorontoCarson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. The firm provides professional home inspection services & home inspection education & publications. Alan Carson is a past president of ASHI, the American Society of Home Inspectors. Thanks to Alan Carson and Bob Dunlop, for permission for InspectAPedia to use text excerpts from The Home Reference Book & illustrations from The Illustrated Home. Carson Dunlop Associates' provides:
    • Commercial Building Inspection Courses - protocol ASTM Standard E 2018-08 for Property Condition Assessments
    • Home Inspection Education Courses including home study & live classes at eleven colleges & universities.
    • Home Inspection Education Home Study Courses - ASHI@Home Training 10-course program.
      Special Offer: Carson Dunlop Associates offers InspectAPedia readers in the U.S.A. a 5% discount on these courses: Enter INSPECTAHITP in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference Book, a reference & inspection report product for building owners & inspectors.
      Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.
    • The Home Reference eBook, an electronic version for PCs, the iPad, iPhone, & Android smart phones.
      Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter inspectaehrb in the order payment page "Promo/Redemption" space.
    • The Illustrated Home illustrates construction details and building components, a reference for owners & inspectors.
      Special Offer: For a 5% discount on any number of copies of the Illustrated Home purchased as a single order Enter INSPECTAILL in the order payment page "Promo/Redemption" space.
    • The Horizon Software System manages business operations,scheduling, & inspection report writing using Carson Dunlop's knowledge base & color images. The Horizon system runs on always-available cloud-based software for office computers, laptops, tablets, iPad, Android, & other smartphones.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Eric Galow, Galow Homes, Lagrangeville, NY. Mr. Galow can be reached by email: ericgalow@gmail.com or by telephone: 914-474-6613. Mr. Galow specializes in residential construction including both new homes and repairs, renovations, and additions.
  • [3] "The Elimination of Unsafe Guardrails, a Progress Report," Elliott O. Stephenson, Building Standards, March-April 1993
  • [4] "Are Functional Handrails Within Our Grasp" Jake Pauls, Building Standards, January-February 1991
  • [5] Access Ramp building codes:
    • UBC 1003.3.4.3
    • BOCA 1016.3
    • ADA 4.8.2
    • IBC 1010.2
  • [6] Access Ramp Standards:
    • ADA (Americans with Disabilities Act), Public Law 101-336. 7/26/90 is very often cited by other sources for good design of stairs and ramps etc. even where disabled individuals are not the design target.
    • ANSI A117.4 Accessible and Usable buildings and Facilities (earlier version was incorporated into the ADA)
    • ASTM F 1637, Standard Practice for Safe Walking Surfaces, (Similar to the above standard
  • [7] The Circular Staircase, Mary Roberts Rinehart
  • [8] Construction Drawings and Details, Rosemary Kilmer
  • [9] Falls and Related Injuries: Slips, Trips, Missteps, and Their Consequences, Lawyers & Judges Publishing, (June 2002), ISBN-10: 0913875430 ISBN-13: 978-0913875438
    "Falls in the home and public places are the second leading cause of unintentional injury deaths in the United States, but are overlooked in most literature. This book is unique in that it is entirely devoted to falls. Of use to primary care physicians, nurses, insurance adjusters, architects, writers of building codes, attorneys, or anyone who cares for the elderly, this book will tell you how, why, and when people will likely fall, what most likely will be injured, and how such injuries come about. "
  • [10] Mobile Home Inspections common defects unique to factory built housing, inspection methods
  • [11] The National Institute of Standards and Technology, NIST (nee National Bureau of Standards NBS) is a US government agency - see www.nist.gov
    • "A Parametric Study of Wall Moisture Contents Using a Revised Variable Indoor Relative Humidity Version of the "Moist" Transient Heat and Moisture Transfer Model [copy on file as/interiors/MOIST_Model_NIST_b95074.pdf ] - ", George Tsongas, Doug Burch, Carolyn Roos, Malcom Cunningham; this paper describes software and the prediction of wall moisture contents. - PDF Document from NIS
  • [12] Slips, Trips, Missteps and Their Consequences, Second Edition, Gary M. Bakken, H. Harvey Cohen,A. S. Hyde, Jon R. Abele, ISBN-13: 978-1-933264-01-1 or ISBN 10: 1-933264-01-2, available from the publisher, Lawyers ^ Judges Publishing Company,Inc., www.lawyersandjudges.com sales@lawyersandjudges.com and also from the InspectAPedia Bookstore (Amazon.com)
  • [13] Slips, Trips, Missteps and Their Consequences, Gary M. Bakken, H. Harvey Cohen, Jon R. Abele, Alvin S. Hyde, Cindy A. LaRue, Lawyers and Judges Publishing; ISBN-10: 1933264012 ISBN-13: 978-1933264011
  • [14] The Stairway Manufacturers' Association, (877) 500-5759, provides a pictorial guide to the stair and railing portion of the International Residential Code. [copy on file as http://www.stairways.org/pdf/2006%20Stair%20IRC%20SCREEN.pdf ] -
  • [15] How to Clean Moldy Wood Framing & Sheathing How to clean/seal mold from/on exposed lumber or plywood subfloor or roof sheathing indoors - some suggestions based on our field and laboratory research
  • [16] Mold-Resistant Building Practices, advice from an expert on how to prevent mold after a building flood and how to prevent mold growth in buildings by selection of building materials and by anti-mold construction details.
  • [17] Steps and Stairways, Cleo Baldon & Ib Melchior, Rizzoli, 1989.
  • [18] The Staircase, Ann Rinaldi
  • [19] Common Sense Stairbuilding and Handrailing, Fred T. Hodgson
  • [20] The Art of Staircases, Pilar Chueca
  • [21] Building Stairs, by pros for pros, Andy Engel
  • [22] A Simplified Guide to Custom Stairbuilding, George R. Christina
  • [23] Basic Stairbuilding, Scott Schuttner
  • [24] The Staircase (two volumes), John Templar, Cambridge: the MIT Press, 1992
  • [25] The Staircase: History and Theories, John Templar, MIT Press 1995
  • [26] Steps and Stairways, Cleo Baldon & Ib Melchior, Rizzoli, 1989.
  • [27] "The Dimensions of Stairs", J. M. Fitch et al., Scientific American, October 1974.
  • [28] Stair & Walkway Standards for Slipperiness or Coefficient of Friction (COF) or Static Coefficient of Friction (SCOF)
    • ANSI A1264.2
    • ANSI B101
    • ASTM D-21, and ASTM D2047 
    • UL-410 (similar to ASTM D-21)
    • NSFI 101-B  (National Floor Safety Institute)
    • NSFI Walkway Auditing Guideline (WAG) Ref. 101-A& 101-B (may appear as ANSI B101.0) sets rules for measuring walkway slip resist
    • OSHA - (Dept of Labor CFR 1910.22 does not specify COF and pertains to workplaces) but recognizes the need for a "qualified person" to evaluate walkway slipperiness
    • ADA (relies on the ANSI and ASTM standards) 
  • [29] A. Sacher, International Symposium on Slip Resistance: The Interface of Man, Footwear, and Walking Surfaces, Journal of Testing and Evaluation (JTE), ISSN: 1945-7553, January 1997  [more focused on slipperiness of polished surfaces
  • [30] Algae is widely recognized as a slippery surface - a Google web search for "how slippery is algae on steps" produced more than 15,000 results on 8/29/12)
  • [31] Slipperiness of algae on walking surfaces, warning, Royal Horticultural Society, retrieved 8/29/2012, original source: http://apps.rhs.org.uk/advicesearch/profile.aspx?pid=418
  • [32] Slipperiness of algae: "Watch your step, wet rocks and algae are slippery" Oregon State University warning  1977  retrieved 8/29/2012, original source: http://www.worldcat.org/title/watch-your-step-wet-rocks-and-algae-are-slippery/oclc/663683915 
  • [33] Coefficient of friction of algae on surfaces [like stair treads]: Delphine Gourdon, Qi Lin, Emin Oroudjev, Helen Hansma, Yuval Golan, Shoshana Arad, and Jacob Israelachvili, "Adhesion and Stable Low Friction Provided by a Subnanometer-Thick Monolayer of a Natural Polysaccharide", Langmuir, 2008 pp 1534-1540, American Chemical Society, retrieved 8/29/2012,
    Abstract: Using a surface forces apparatus, we have investigated the adhesive and lubrication forces of mica surfaces separated by a molecularly thin, subnanometer film of a high-molecular-weight (2.3 MDa) anionic polysaccharide from the algae Porphyridium sp. adsorbed from aqueous solution. The adhesion and friction forces of the confined biopolymer were monitored as a function of time, shearing distance, and driving velocity under a large range of compressive loads (pressures). Although the thickness of the dilute polysaccharide was <1 nm, the friction was low (coefficient of friction = 0.015), and no wear was ever observed even at a pressure of 110 atm over 3 decades of velocity, so long as the shearing distances were less than twice the contact diameter. Atomic force microscopy in solution shows that the biopolymer is able to adsorb to the mica surface but remains mobile and easily dragged upon shearing. The adhesion (adsorption) of this polysaccharide even to negatively charged surfaces, its stable low friction, its robustness (high-load carrying capacity and good wear protection), and the weak (logarithmic) dependence of the friction force on the sliding velocity make this class of polyelectrolytes excellent candidates for use in water-based lubricant fluids and as potential additives to synovial fluid in joints and other biolubricating fluids. The physical reasons for the remarkable tribological properties of the ultrathin polysaccharide monolayer are discussed and appear to be quite different from those of other polyelectrolytes and proteins that act as thick “polymer brush” layers.
  • [34] Jinjin Li, Yuhong Liu, Jianbin Luo, Pengxiao Liu, and Chenhui Zhang, "Excellent Lubricating Behavior of Brasenia schreberi Mucilage" Langmuir 2012 28 (20), 7797-7802
  • [35] Jason R. Stokes, Lubica Macakova, Agnieszka Chojnicka-Paszun, Cornelis G. de Kruif, and Harmen H. J. de Jongh, "Lubrication, Adsorption, and Rheology of Aqueous Polysaccharide Solutions, Langmuir 2011 27 (7), 3474-3484
  • [36] "Coefficients of Friction for Ice", The Physics Factbook™, Glenn Elert, Ed., retrieved 8/29/12, original source: http://hypertextbook.com/facts/2004/GennaAbleman.shtml
  • [37] "Coefficients of Friction for Ice", The University of the State of New York Reference Tables for Physical Setting/Physics. New York: The State Education Department, 2002. Op. Cit.
  • [38] Serway Physics for Scientists and Engineers 4th edition (p. 126.)
  • [39] "How Slippery Is It", retrieved 8/29/12, original source http://www.icebike.org/Articles/howslippery.htm
  • [40] John E. Hunter, "Friction Values", The Source, Society of Accident Reconstructionists, Winter 1998. Study of frictional values of car tires involved in collisions on snow or ice covered roadways.
  • [41] Frictional Coefficients of some Common Materials and Materials Combinations, The Engineering Toolbox, retrieved 8/29/2012, original source: http://www.engineeringtoolbox.com/friction-coefficients-d_778.html [copy on file as Friction and Coefficients of Friction.pdf ]
  • [42] Stairways and Ladders, A Guide to OSHA Rules, OSHA, U.S. Department of Labor, 3124-12R 2003 - Web Search 05/28/2010 original source: http://www.osha.gov/Publications/osha3124.pdf. OSHA regulations govern standards in the construction industry and in the workforce Quoting from OSHA whose focus is on workplace safety and so excludes discussion of falls and stair-falls in private homes:

    OSHA estimates that there are 24,882 injuries and as many as 36 fatalities per year due to falls from stairways and ladders used in construction. Nearly half of these injuries are serious enough to require time off the job--11,570 lost workday injuries and 13,312 non-lost workday injuries occur annually due to falls from stairways and ladders used in construction. These data demonstrate that work on and around ladders and stairways is hazardous. More importantly, they show that compliance with OSHA's requirements for the safe use of ladders and stairways could have prevented many of these injuries. -osha.gov/doc/outreachtraining/htmlfiles/stairlad.html

  • [43] International Building Code, Stairway Provisions, Section 1009: Stairways and Handrails, retrieved 8/29/12, original source: http://www.amezz.com/ibc-stairs-code.htm [copy on file as IBC Stairs Code.pdf]
  • [44] Model Building Code, Chapter 10, Means of Egress, retrieved 8/29/12, original source: http://www2.iccsafe.org/states/newjersey/NJ_Building/PDFs/NJ_Bldg_Chapter10.pdf, [copy on file as NJ_Bldg_Chapter10.pdf] adopted, for example by New Jersey. International Code Council, 500 New Jersey Avenue, NW, 6th Floor, Washington, DC 20001, Tel: 800-786-4452

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  • ...
HOME ABOUT CONTACT COPYING DESCRIPTION POLICIES PRINTING PRIVACY © 2013 Copyright InspectAPedia.com