InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
Home | Air
Conditioning
| Electrical
-
Energy Saving
| Environment
Indoor
| Exteriors | Heating | Home
Inspection
| Insulate
-
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Solar
Energy
| Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
ALUMINUM WIRING HAZARDS & REPAIRS
ALUMINUM WIRE FAILURE REPORTS
ALUMINUM WIRE RISK
  Aluminum Wiring Safety
  Aluminum Wiring - CPSC Publication #516
HOW TO RECOGNIZE ALUMINUM WIRING
HOW TO REDUCE THE RISK of ALUMINUM WIRING
  HOW TO REDUCE THE AL WIRE RISK: DETAILS
  COPALUM ALUMINUM WIRE CONNECTORS
  ALUMI-CONN ALUMINUM WIRE CONNECTORS
  ALUMINUM GROUND WIRES
  MAKING SPACE FOR ALUMINUM WIRE CONNECTORS
NOT-Recommended Repair Products
  CPSC Against Twist-On Aluminum Wire Connectors
  CPSC Letter Aluminum Wiring Connectors
  CPSC Twist-On Wiring Connectors Meeting Log
  Ideal 65 Connector for Aluminum Wire Repair?
  COALR & CU-AL Devices?
  Scotchlok 3M connector
  Aluminum Wiring Repair Methods - CPSC Meeting
BOOKSTORE - ELECTRICAL
DIRECTORY OF ELECTRICIANS - Aluminum Wiring
DIRECTORY OF ELECTRICIANS - FPE Zinsco
ALUMINUM WIRING ADVICE FOR RENTERS
Aluminum Wiring Bibliography

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Aluminum Wiring Bibliography
InspectAPedia®  -    

Photograph of  this overheating and improperly-made aluminum to copper pigtail splice.Photograph of  this overheating and improperly-made aluminum to copper pigtail splice.
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

Bibliography of publicly available articles, pamphlets, resources providing information about aluminum electrical wiring.

Aluminum Wiring Bibliography

ALUMINUM WIRING HAZARDS & REPAIRS
ALUMINUM WIRE FAILURE REPORTS
ALUMINUM WIRE RISK
  Aluminum Wiring Safety
  Aluminum Wiring - CPSC Publication #516
HOW TO RECOGNIZE ALUMINUM WIRING
HOW TO REDUCE THE RISK of ALUMINUM WIRING
  HOW TO REDUCE THE AL WIRE RISK: DETAILS
  COPALUM ALUMINUM WIRE CONNECTORS
  ALUMI-CONN ALUMINUM WIRE CONNECTORS
  ALUMINUM GROUND WIRES
  MAKING SPACE FOR ALUMINUM WIRE CONNECTORS
NOT-Recommended Repair Products
  CPSC Against Twist-On Aluminum Wire Connectors
  CPSC Letter Aluminum Wiring Connectors
  CPSC Twist-On Wiring Connectors Meeting Log
  Ideal 65 Connector for Aluminum Wire Repair?
  COALR & CU-AL Devices?
  Scotchlok 3M connector
  Aluminum Wiring Repair Methods - CPSC Meeting
BOOKSTORE - ELECTRICAL
DIRECTORY OF ELECTRICIANS - Aluminum Wiring
DIRECTORY OF ELECTRICIANS - FPE Zinsco
ALUMINUM WIRING ADVICE FOR RENTERS
Aluminum Wiring Bibliography

Recommendations for the Homeowner/Occupant

  • "The Trouble With Aluminum Wiring," Consumer Reports, January, 1981, p. 42
  • "The Use of Aluminum Conductors with Electrical Wiring Devices in Electrical Wiring Systems," Underwriters Laboratories, Inc., 333 Pfingsten Road, Northbrook, IL 60062, Issued March 1973, reissued July 1980
  • J. Aronstein, "Reducing the Fire Hazard in Aluminum-Wired Homes," Wright-Malta Corporation, Ballston Spa, NY, Jan. 25, 1982
  • Reducing the Fire Hazards in Aluminum-Wired Homes
  • "Is YOUR Aluminum Wiring Safe?" article discussing safety claims made without looking at the wiring, J. Aronstein, 11/21/95
  • CPSC Publication 516 on Aluminum Wiring

Information on Aluminum Wiring for Home Inspectors

  • D.J. Friedman, "Safety Considerations for the Electrical Inspector," The ASHI Technical Journal of home inspection and in-service building component failures, Vol. 2 No. 1, Winter, 1992
  • D.J. Friedman, "Aluminum Wiring Poses Potential Fire Hazard," The Journal of Light Construction, June 1996 [Reprinted in the ASHI Reporter, January 1997, p.10-11]

Field Surveys of Aluminum Wiring Hazards & Failures

  • "National Controlled Study of Relative Risk of Overheating of Aluminum Compared with Copper Wired Electrical Receptacles in Homes and Laboratory," Executive Summary. Prepared for U.S. Consumer Product Safety Commission. Report #F-C4812-01, Franklin Research Center, Philadelphia, PA, April 20, 1979
  • R. Newman and W.H. King, Jr., "Pilot Survey of Branch Wiring Systems in Montgomery County, Maryland," U.S. Consumer Product Safety Commission, Sept., 1977
  • J. Aronstein, "Summary Report, Study of Overheating of Aluminum-Wired Electrical receptacles in Scarborough, Toronto, Homes," Wright-Malta Corporation, Ballston Spa, NY, Jan. 11, 1982

Aluminum Wiring Connectors/Connections

  • H. Dupre, "The Problems Involved in Designing Connectors for Aluminum Cable," Misc. Paper no. 51-325, AIEE Fall General Meeting, October, 1951.
  • J. Aronstein and W.E. Campbell, "Overheating Failures of Aluminum-Wired Special Service Connectors," IEEE Trans. Components, Hybrids, and Mfg. Tech., V. CHMT-6 No. 1, Mar. 1983
  • N.T. Bond, "Reliability in Electrical Terminations on Aluminum Conductors," Electrical Products Div., Alcoa Conductor Products Co., Alcoa Laboratories, Massena, NY.
  • C.W. Zimmerer and F.Neumer, "Aluminum Building Wires and Connectors," Bulletin of Research, No. 48, Underwriters Laboratories Inc., Sept. 1954
  • J. Aronstein and W.E. Campbell, "The influence of Corrosion Inhibitor and Surface Abrasion on the Failure of Aluminum-Wired Twist-on Connections," IEEE Trans. Components, Hybrids, and Mfg. Tech., V. CHMT-7 No. 1, March, 1984.
  • R. Schubert, "Erratic Behavior of Al/Al Wire Junctions," Elecrical Contacts - 1986, Proceedings of the 32nd IEEE Holm Conference on Electrical Contacts, Boston, 1986.
  • "Test of 'Old Technology' Aluminum Wire With Twist-On Connectors," Project Report CPSC-C-79-0079, Task II, for U.S. Consumer Product Safety Commission. Wright-Malta Corp., Ballston Spa, NY, November 23, 1981
  • J. Aronstein, "Overheating Failures of Presently-Listed Aluminum Wiring Connection Combinations Within Rated Service Conditions". Wright-Malta Corp., Ballston Spa, NY, November 23, 1981
  • R.L. Hicks, "Pigtail Splicing Connections for Baseboard Heaters and Similar Cyclic Loads," Ontario Hydro, Research Division

Failure Mechanisms of Aluminum Wiring

  • M. Braunovic, "Fretting Corrosion Between Aluminum and Different Contact Materials," Electrical Contacts - 1977, Proceedings of the 23rd Annual Meeting of the Holm Conference on Electrical Contacts, Chicago, 1977.
  • M. Braunovic, "Effect of Fretting on the Contact Resistance of Copper, Aluminum, and Nickel-Coated Aluminum Wire Connections," Wear, V. 112, 1986.
  • N.T. Bond, D.L. Robinson, and M. Mohajery, "Fundamental Considerations of Aluminum Electrical Contact Interfaces," Elecrical Contacts - 1977, Proceedings of the 23rd Annual Meeting of the Holm Conference on Electrical Contacts, Chicago, 1977.
  • J. Aronstein, "Electromigration Failure of Aluminum Contact Junctions," Elecrical Contacts - 1995, Proceedings of the 41st Annual Meeting of the Holm Conference on Electrical Contacts, Montreal, 1995.
  • J. Aronstein, "Conduction in Failing Aluminum Connections," Electrical Contacts - 1990, Proceedings of the 36th IEEE Holm Conference on Electrical
  • Contacts meeting jointly with the 15th International Conference on Electrical Contacts," Montreal, 1990.
  • M. Leger, "Metallurgical Analysis of Failed CO/ALR Devices," Ontario Hydro, #78-54-K, Ontario, Canada, February, 1978.
  • J. Aronstein, "Failure of Aluminum Connections in Residential Applications," Elecrical Contacts - 1991, Proceedings of the 37th Annual Meeting of the Holm Conference on Electrical Contacts, Chicago, 1991.
  • J. Aronstein, "AC and DC Electromigration in Aluminum Contact Junctions," Electrical Contacts - 1996, Proceedings of the 42nd IEEE Holm Conference on
  • Electrical Contacts meeting jointly with the 18th International Conference on Electrical Contacts," Chicago, September 1996

Nickel Plated Aluminum Wire

  • H.O. Hansson, "Sinipal: Swedish-bred Aluminum Substitute for Copper Wire," Wire and Wire Products, September, 1970.
  • J. Aronstein and T.K. Hare, "Evaluation and Analytical Electron Microscopy Investigation of a Plated Aluminum Wire for Branch Circuit Applications," IEEE Transactions on Components, Hybrids, and Manufacturing Technology, V. 11, No.2, June 1988, p. 218-226

Copper-Clad Aluminum Wire

  • J.C. Fan, "An Examination of Copper Clad Aluminum Conductor for Circuit Size Wiring," Texas Instruments Inc., Metallurgical Materials Div., Wire Products Dept., Attleboro, MA.

Alloy Aluminum Wire

  • J. Aronstein and W.E. Campbell, "Evaluation of an Aluminum Conductor Material for Branch Circuit Applications," IEEE Trans. Components, Hybrids, and Mfg. Tech., V. CHMT-8 No. 1, Mar. 1985

Connector/connection standards and test methods

  • UL Standard 1567, Underwriters Laboratories, Inc., Northbrook IL (CO/ALR Wiring Device Terminals for Aluminum Wire)
  • UL Standard 486C, Underwriters Laboratories, Inc., Northbrook IL (Splicing Connectors for Aluminum Wire)
  • ASTM B812-90, "Standard Test Method for Resistance to Environmental Degradation of Electrical Pressure Connections Involving Aluminum and Intended for Residential Applications," ASTM, 1916 Race Street, Philadelphia, PA

Industry Handbooks

"Aluminum Building Wire Installation Manual and Design Guide," The Aluminum Association, Inc.

Government Agency Documents

  • R. Newman, "Hazard Analysis of Aluminum Wiring," April, 1975, U.S. CPSC, NIIC-0600-75-H006
  • J.T. Wilson, "Report of the Commission of Inquiry on Aluminum Wiring," Ontario, Canada, March, 1979
  • J. Aronstein, "Tests of 'Old Technology' Aluminum Wire," Wright-Malta Corp. Project Report CPSC-C-81-1418, U.S. Consumer Product Safety Commission, Washington, DC, Feb. 10, 1983

The following links point to additional documents available on Internet:

ALUMINUM WIRING HAZARDS & REPAIRS
ALUMINUM WIRE FAILURE REPORTS
ALUMINUM WIRE RISK
  Aluminum Wiring Safety
  Aluminum Wiring - CPSC Publication #516
HOW TO RECOGNIZE ALUMINUM WIRING
HOW TO REDUCE THE RISK of ALUMINUM WIRING
  HOW TO REDUCE THE AL WIRE RISK: DETAILS
  COPALUM ALUMINUM WIRE CONNECTORS
  ALUMI-CONN ALUMINUM WIRE CONNECTORS
  ALUMINUM GROUND WIRES
  MAKING SPACE FOR ALUMINUM WIRE CONNECTORS
NOT-Recommended Repair Products
  CPSC Against Twist-On Aluminum Wire Connectors
  CPSC Letter Aluminum Wiring Connectors
  CPSC Twist-On Wiring Connectors Meeting Log
  Ideal 65 Connector for Aluminum Wire Repair?
  COALR & CU-AL Devices?
  Scotchlok 3M connector
  Aluminum Wiring Repair Methods - CPSC Meeting
BOOKSTORE - ELECTRICAL
DIRECTORY OF ELECTRICIANS - Aluminum Wiring
DIRECTORY OF ELECTRICIANS - FPE Zinsco
ALUMINUM WIRING ADVICE FOR RENTERS
Aluminum Wiring Bibliography

Fire Ignition/Fire investigation

  • J. Aronstein, "Fire Due to Overheating Aluminum Wired Branch Circuit Connections," Electrical Safety Conference, Univ. of Wisconsin-Extension, Madison, WI, April 7, 1981

Contact Addresses for Requesting Information

  • The American Society of Home Inspectors, ASHI 847-290-1919 85 West Algonquin Road 847-290-1920 FAX Arlington IL 60005-4423 http://InspectAPedia.com/ashi/ashihome.htm
  • The Aluminum Associon 900 19th St. NW, Washington DC 20006
  • NFPA - (National Fire Protection Association) 1 Batterymarch Park P.O. Box 9101 Quincy, MA 02269-9101
  • UL - Underwriters Laboratories Inc. 333 Pfingsten Road Northbrook, IL 60062
  • NEMA -National Electrical Manufacturers Association 2101 L Street, N.W. Washington, DC 20037 202-457-8400 FAX 202-457-8411
  • Internat. Assoc. of Elect. Insp. 214-235-1455 901 Waterfall Way, Suite 602 214-235-3855 Richardson, TX 75080 6226,563 CIS
  • The Journal of Light Construction 802-434-4747 RR2 Box 146 jlc@bginet.com Richmond VT 05477
  • Also AIEE - tbd.

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

 


More Information on Building Diagnostic Inspections and Repairs

    ...
InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

02/03/2010 - 10/03/96 InspectAPedia.com/aluminum/awbiblio.htm - © 1996 Dr. Jess Aronstein & © 2009 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark