InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile Phone/PDA website viewMobile View
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR

AFCIs ARC FAULT CIRCUIT INTERRUPTERS

ALUMINUM SECs & WIRING
ALUMINUM WIRING HAZARDS
ALUMINUM WIRE FAILURE REPORTS
ALUMINUM WIRE RISK
  Aluminum Wiring Safety
  Aluminum Wiring - CPSC Publication #516-PDF
  Aluminum Wiring - CPSC Publication #516-HTML
ALUMINUM WIRING, HOW TO RECOGNIZE
ALUMINUM WIRING, HOW TO REDUCE THE RISK
  HOW TO REDUCE THE AL WIRE RISK: DETAILS
  COPALUM ALUMINUM WIRE CONNECTORS
  ALUMI-CONN ALUMINUM WIRE CONNECTORS
  ALUMINUM GROUND WIRES
  MAKING SPACE FOR ALUMINUM WIRE CONNECTORS
  REDUCING THE FIRE HAZARD IN ALUMINUM-WIRED HOMES - Full Report

ALUMINUM WIRING REPAIR ELECTRICIANS
ALUMINUM WIRING REPAIR, Other Products
ALUMINUM WIRING REPAIR COALR & CU-AL DEVICES
ALUMINUM WIRING REPAIR NOT-Recommended Products
  CPSC Against Twist-On Aluminum Wire Connectors
  CPSC Letter Aluminum Wiring Connectors
  CPSC Twist-On Wiring Connectors Meeting Log
  Ideal 65 Connector for Aluminum Wire Repair?
  COALR & CU-AL Devices?
  Scotchlok 3M connector
Aluminum Wiring Repair Methods - CPSC Meeting 9/28/95
  Contents
  Copper Pigtailing
  Pigtailing failures
  Additional failures
  Field Failures
  Wire-to-wire Contact
  Equivalent Circuits
  Current Flow
  Connection Deterioration
  UL Test Inadequate
  "Special Connector" Failures
  AMP TYCO COPALUM
  Alternative Repair
  Special Concerns
Reducing the Fire Hazards in Aluminum-Wired Homes
ALUMINUM WIRING ADVICE FOR RENTERS
ALUMINUM WIRING BIBLIOGRAPHY
Aluminum Wiring Notes for Home Inspectors
Aluminum Wiring Summary Page for Public Use
BOOKSTORE - ELECTRICAL

DIRECTORY OF ELECTRICIANS - Aluminum Wiring
DIRECTORY OF ELECTRICIANS - FPE Zinsco
Reducing the Fire Hazards in Aluminum-Wired Homes
THERMAL EXPANSION of MATERIALS

UNDERGROUND SERVICE LATERALS
VOLTAGE MEASUREMENT EQUIPMENT

WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING

ZINSCO / SYLVANIA HAZARDS

More Information

Slide 28 Aluminum Wire: Why the UL High-Current Cycle test is inadequate - UL Standard 486C
InspectAPedia®  -    

  • Aluminum wiring standards
  • Inadequacy of the UL Standard 486 as the basis for qualifying twist-on connectors for splicing aluminum to copper
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

This article discusses the inadequacy of the UL Standard 486 as the basis for qualifying twist-on connectors for splicing aluminum to copper wires.

This is Aluminum Wiring Repair Procedure - Page 9 Color photos and descriptive captions from CPSC Meeting 9/28/95. In this document aluminum wire twist-on connector failures and repair procedures are described, including aluminum wire repair methods which work and methods which do not work and are unsafe. Color photos of aluminum wire repair procedures, and photos of failed connectors are included.

This document series describes hazards with existing aluminum wiring repair products, explains the aluminum wiring failure mechanism, and reviews recommended retrofit procedures including use of readily-available materials. This information was presented to the US Consumer Product Safety Commission by Dr. J. Aronstein, 9/28/95.

This information was presented to the US Consumer Product Safety Commission by Dr. J. Aronstein, 9/28/95. The minutes of that meeting were obtained under the Freedom of Information Act and posted by Daniel Friedman January 1996.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Click any image to see an enlarged versin.


Slide 28 28. This table compares factors of actual use with the UL486C test conditions. It is evident that the UL listing is based principally on a high current cycling test, which does not really stress the connection in ways that it is stressed in an actual residential application.




Slide 29 29. Additionally, the UL486C standard does not use the older wire for its tests, does not require testing of the combinations most likely to be used, and tests a statistically inadequate sample size.


Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Aluminum Wiring Repair Methods - CPSC Meeting 9/28/95
  Contents
  Copper Pigtailing
  Pigtailing failures
  Additional failures
  Field Failures
  Wire-to-wire Contact
  Equivalent Circuits
  Current Flow
  Connection Deterioration
  UL Test Inadequate
  "Special Connector" Failures
  AMP TYCO COPALUM
  Alternative Repair
  Special Concerns

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • GO TO the ALUMINUM WIRING INFO WEBSITEThe Aluminum Wiring Information Website Aluminum Wiring Hazards and Repairs: in-depth info, photos, documents. Main Page.
  • The Aluminum Electrical Wiring Hazard Explained (in the document you are presently viewing)
  • How to Reduce the Risk in buildings with Aluminum Electrical Wiring - Overview of Acceptable Repair Practices (in the document you are presently viewing)
  • Aluminum Electrical Repair Method Details - "How to" details, how to identify, COPALUM repair, alternative repairs, history, products, research, source of special AMP TYCO COPALUM connectors & COPALUM Electricians (in the document you are presently viewing)
  • COPALUM Electricians: Sources of TYCO COPALUM -Certified/Trained Aluminum Wire Repair Services (in the document you are presently viewing)
  • Other Products, Ideal 65 Purple Twister (not recommended), & other Aluminum Wire Products/Articles (in the document you are presently viewing)
  • The Aluminum Wiring Bibliography: extensive resources on Aluminum Wiring
  • Aluminum Wire Failure Reports & Photos: Real life aluminum wiring field failure reports
  • Reducing the Fire Hazards in Aluminum-Wired Homes, Jess Aronstein, Ph.D., This document answers most technical questions about the hazards and remedies of aluminum electrical wiring. Some of the sections of this very thorough document are listed below:
  • Fire Hazards With Aluminum to Copper Twist-on Connectors & Acceptable Aluminum Wiring Repair Practices Color Photos, Current Issues. 9/28/95 CPSC Meeting Minutes
  • "Is YOUR Aluminum Wiring Safe?" article discussing safety claims made by some people without looking at the wiring, J. Aronstein, 11/21/95
  • "Repairing Aluminum Wiring," U.S. Consumer Product Safety Commission Publication CPSC#516 available online
  • * Safety Hazards and Safe Inspection Procedures for Electrical and Home Inspectors at Residential Electric Panels
  • Electrical Panels, How to Inspect in buildings, safety for electrical inspectors, electrical panel, fusing, wiring defects, defective products. Inspection Class Presentation
  • Electrical System & Wiring Hazard Inspection, Detection, Cause, Remedy, Prevention - Main Electrical Page
  • Directory of Home Inspectors accessible via Internet
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com