InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile Phone/PDA website viewMobile View
HOME & BUILDING INSPECTORS & INSPECTION METHODS

AGE of a BUILDING - how to determine
AIR CONDITIONING & HEAT PUMP SYSTEMS
ALUMINUM WIRING HAZARDS & REPAIRS
ANIMAL ENTRY POINTS in buildings
ANIMAL ODORS IN buildings

ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS IDENTIFICATION IN buildings
ASHI American Society of Home Inspectors
ASHI Certification of Home Inspectors

ATTORNEYS and EXPERT WITNESSES
ATTIC LEAKS, CONDENSATION & ATTIC MOLD
ATTIC VENTILATION

BASEMENT CEILING VAPOR BARRIER
BASEMENT HEAT LOSS
BUILDING SAFETY HAZARDS GUIDE
BUILDING SETTLEMENT

CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHIMNEY INSPECTION & REPAIR GUIDE
CHINESE DRYWALL HAZARDS

CRAWL SPACES
CRAWL SPACE SAFETY ADVICE

DECK & PORCH CONSTRUCTION
DECK COLLAPSE Case Study
DECK FINISHES COATINGS PRESERVATIVES
DECK FLASHING LEAKS, ROT Case Study

DIRECTORY of BUILDING INSPECTORS
Disasters: Building Inspection & Repair Safety
DRINKING WATER

ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
Electrical Inspection Safety
ENERGY SAVINGS in buildings
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

EXTERIORS of buildings

Fiberglass hazards in buildings
Fire Clearances, Single-Wall Metal Flues
FIREPLACES & HEARTHS

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODS IN buildings-priorities
FOUNDATION CRACKS & DAMAGE GUIDE
FPE Stab-Lok HAZARDS & REPAIRS WEBSITE

GAS PIPING, VALVES, CONTROLS
GUTTERS & DOWNSPOUTS
GLUES ADHESIVES, EXTERIOR CONSTRUCTION

HEATING SYSTEMS

HOME & BUILDING INSPECTORS & INSPECTION METHODS
  Advice on Becoming a Home Inspector
  ASHI Phil Monahon Award
  BUILDING INSPECTORS DIRECTORY
    RHI Registry of Canadian Home Inspectors
  BUILDING DEFECTS LISTS

  Checklists vs Narrative Reports

  Historic Homes, Home Improvement Costs, Research

  HOME INSPECTOR EDUCATION
  Home Inspector, How to Become a
  Home Inspector Skills, Reports
  Home Inspection Company Franchises
  Home Inspection Components Master List
  Home Inspection Definitions & Terms
  Home Inspection Ethical Codes
  Home Inspection, How to Get The Most Benefit From
  Home Inspection Publications
  Home Inspection Report Writing Guide
  Home Inspection Safety Hazards
  HOME INSPECTION STANDARDS
  HOUSE DOCTOR, how-to be
  Home Inspection Report Writing Guide
  Home Inspection Safety Hazards
  HOME INSPECTION STANDARDS
  HOUSE DOCTOR, how-to be
  How Much Should You Pay For Professional Services?
  INSPECTION COMONENTS MASTER LIST
  Mobile Home Inspection Guide
  VISUAL PERCEPTION ERRORS

HOT WATER HEATERS
HOUSE PARTS, DEFINITIONS

INDOOR AIR QUALITY IMPROVEMENT GUIDE

INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT

INTERIORS of buildings

Journal of Light Construction - Index 1994

KIT HOMES, Aladdin, Sears, Wards, Others

LEED GREEN BUILDING CERTIFICATION
LEED Building Designation & IAQ
LIGHTNING PROTECTION SYSTEMS
LOG HOME GUIDE

MANUALS & PARTS GUIDES - HVAC
Mobile Home Inspection Guide

MOISTURE CONTROL in buildings
MOISTURE METER STUDY

MOLD in buildings
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TESTING SERVICES
MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS & SMELLS DIAGNOSIS & CURE

OIL TANK PIPING & PIPING DEFECTS
OIL TANKS INSPECT LEAK TEST ABANDON REGS

PAINT ANALYSIS, DIAGNOSTIC USES
PAINT & STAIN GUIDE, EXTERIOR
PAINT FALURE, DIAGNOSIS, CURE, PREVENTION

PIPING IN buildings, Clogs Leaks Types

PLASTER & BEAVERBOARD & DRYWALL
PLASTER BULGES & PILLOWS
PLASTER LATH, METAL
PLASTER, LOOSE FALL HAZARDS
PLASTER TYPE IDENTIFICATION

PLUMBING SYSTEM INSPECT DIAGNOSE REPAIR
PUSHMATIC - BULLDOG PANELS

Reports: Checklists vs Narrative

ROOFING INSPECTION & REPAIR
ROOF VENTILATION SPECIFICATIONS

SAFE DECK CONSTRUCTION GUIDE
SAFETY HAZARDS & INSPECTIONS
Safety for Building Inspectors
SAFETY: Elderly & Veterans Home Safety
SAFETY FOR ELECTRICAL INSPECTORS
SAFETY HAZARDS GUIDE
Safety for Septic Inspectors
Sears Catalog kit homes - how to identify
Septic System Safety Hazards
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

SIDING, Sheathing Identification - Photo Guide
SIDING, ALUMINUM
SIDING, ASBESTOS CEMENT SHINGLES
SIDING ASPHALT ROOF SHINGLES on WALLS
SIDING ASPHALT SHINGLE or SHEET
SIDING DAMAGE by SPLASHBACK
SIDING EIFS & STUCCO
SIDING, FIBER CEMENT
SIDING HARDBOARD
SIDING STEEL
SIDING VINYL
SIDING, WOOD PRODUCT CHOICES
SIDING, WOOD INSTALLATION
SIDING WOOD, FAILURES OVER FOAM BOARD
SIDING WOOD, FLASHING DETAILS
SIDING WOOD SHINGLE INSTALLATION

SINKHOLES, WARNING SIGNS
SLAB CRACK EVALUATION

SOLAR ENERGY SYSTEMS
Splits in Structural Wood Beams
SQUARE-D RECALLS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STAINS on INDOOR SURFACES: PHOTO GUIDE

STANDARDS, HOME INSPECTION

STAIRS, RAILINGS, LANDINGS, RAMPS

STONE CLEANING METHODS
STRESS SKIN INSULATED PANELS

STRUCTURAL INSPECTIONS & DEFECTS

TANK TYPES: WATER, OIL, EXPANSION, ALL
THERMAL TRACKING Indicates Heat Loss

VAPOR BARRIERS & HOUSEWRAP
VAPOR CONDENSATION & BUILDING SHEATHING

VENTILATION in buildings
VISUAL PERCEPTION ERRORS

WATER ENTRY in buildings

WATER HEATERS

WATER ODORS, CAUSE CURE

WATER PRESSURE & FLOW MEASUREMENT

WATER PUMPS, TANKS, TESTS, WELLS, REPAIRS
WATER PUMPS & WELLS

WATER QUANTITY IMPROVEMENT

WATER SOFTENERS & CONDITIONERS

WATER TEST CHOICES & WATER TEST FEES
WATER TESTS, CONTAMINANTS, TREATMENT
WATER TESTING ADVICE

WATER TREATMENT EQUIPMENT CHOICES

WELLS CISTERNS & SPRINGS
WELL CLEARANCES
WELL CHLORINATION SHOCKING PROCEDURE>

WINDOWS & DOORS

Wood Burning Boilers, Furnaces Fireplaces Stoves
WOOD ROOF INSPECTION GUIDE

ZINSCO / SYLVANIA HAZARDS

More Information

Photograph of building damage near Los Angeles 2000 © Daniel Friedman Index to Articles - Journal of Light Construction 1994
InspectAPedia®  -    

  • Where to find information in the JLC
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. our contact info is at InspectAPedia.com/Contact.htm.

Steven Bliss served as editorial director and co-publisher of The Journal of Light Construction for 16 years and previously as building technology editor for Progressive Builder and Solar Age magazines. He worked in the building trades as a carpenter and design/build contractor for more than ten years and holds a masters degree from the Harvard Graduate School of Education.

Excerpts from his recent book, Best Practices Guide to Residential Construction, Wiley (November 18, 2005) ISBN-10: 0471648361, ISBN-13: 978-0471648369, appear throughout this website, with permission and courtesy of Wiley & Sons. Best Practices Guide is available from the publisher, J. Wiley & Sons, and also at Amazon.com.

Excerpts with updates and annotations expanding the original Best Practices Guide text can be found in the online review and book summary at BEST CONSTRUCTION PRACTICES GUIDE and also at DECK & PORCH CONSTRUCTION, at INDOOR AIR QUALITY IMPROVEMENT GUIDE, and in other articles found at InspectAPedia.com such as HOUSEWRAP AIR & VAPOR BARRIERS, SOUND CONTROL in buildings, and other topics.


JOURNAL OF LIGHT CONSTRUCTION ANNUAL INDEX  -  1994 - PDF Version of this file


MASTER94.TXT ASCII MASTER FILE, edited for Internet 12/9/95 djf
DATA AS OF:  11/22/94 - Indexer: Dan Friedman  -   
---------------------------------------------------------------------------
                                                  NewEngland   National
- ACCESSIBLE DESIGN
  alarm, strobe light, hearing impaired (P)        JAN/94 p62   JAN/94 p54
  ramp, mini for patio doors (P)                   JUN/94 p76   JUN/94 p61
  shower, custom-built accessible                * APR/94 p79   APR/94 p63
- ARCHITECTURE & DESIGN
  American Houses, a Field Guide (B)               DEC/94 p69   DEC/94 p60
  cape, making room in modern                    * JAN/94 p18   JAN/94 p12
  children, designing a house for                  NOV/94 p20   NOV/94 p20
  decking material, poolside masonry (Q)           FEB/94 p17   FEB/94 p15
  dome homes, fiberglass for homeless              MAR/94 p10   MAR/94 p10
  engineering, when is it needed by a G.C.?        JAN/94 p58   JAN/94 p16
  floor-planning, ten common pitfalls            * NOV/94 p45   NOV/94 p35
  Innovative Products - Issue Theme              * JUL/94       JUL/94
  kitchen design for two-cooks                     JAN/94 p56   JAN/94 p48
  mathematics for builders (B)                     SEP/94 p26   SEP/94 p21
  scale, the great mystery of house design         APR/94 p25   APR/94 p19
  shed, saltbox-style                              AUG/94 p20   AUG/94 p13
  sun or shade, designing for                    * FEB/94 p14   FEB/94 p11
  traditional styles used for modern needs         MAR/94 p15   MAR/94 p13
  wind resistance solutions                        MAR/94 p69   MAR/94 p55
- BATHROOMS
  shower heads, proper height (L)                  APR/94 p7    APR/94 p7
  tub and shower enclosures, custom              * DEC/94 p45   DEC/94 p41
  tubs, installing jetted                        * SEP/94 p37   SEP/94 p25
- BUSINESS MANAGEMENT
  accounting, small builder's guide              * OCT/94 p56   OCT/94 p44
  billing system for builders                    * MAY/94 p64   MAY/94 p44
  bonus system that works                        * FEB/94 p52   FEB/94 p40
  Business Basics - Issue Theme                  * JAN/94       JAN/94
  business plan, writing a                         APR/94 p32   APR/94 p23
  business survey, JLC '93                         JAN/94 p11   JAN/94 p9
  checklist for builders prioritizes paperwork   * JAN/94 p53   JAN/94 p28
  contractor referral services                     JAN/94 p9    JAN/94 p7
  customers, pre-qualify to ID prospects           SEP/94 p21   SEP/94 p18
  drivers license, when is commercial needed       NOV/94 p14   NOV/94 p12
  employee performance appraisal form              FEB/94 p54   FEB/94 p42
  employee reviews, carpenter's report card      * JAN/94 p33   JAN/94 p25
  employee trade-skill assessment form             FEB/94 p53   FEB/94 p41
  employees, finding & keeping good                MAR/94 p23   MAR/94 p19
  estimating checklist for remodelers            * JAN/94 p25   JAN/94 p21
  Estimating Tables for Home Building (B)          SEP/94 p24   SEP/94 p21
  estimating, Means data for spreadsheets (P)      SEP/94 p71   SEP/94 p58
  estimating, unit-price/square-foot             * APR/94 p69   APR/94 p53
  guaranteed-max-cost explained (L)                FEB/94 p5    FEB/94 p4
  home office expense, rules for calculating       NOV/94 p16   NOV/94 p15
  home office expense, who can deduct              OCT/94 p17   OCT/94 p17
  insurance, how to buy for construction           NOV/94 p26   NOV/94 p23
  lean times, preparing for                      * SEP/94 p66   SEP/94 p54
  loans, obtaining SBA-guaranteed                  JUN/94 p20   JUN/94 p51
  loans, ten steps to obtaining                    AUG/94 p27   AUG/94 p20
  managing more than one job                     * NOV/94 p55   NOV/94 p41
  payment, cashing partial may lose rights         JUL/94 p24   JUL/94 p19
  payment, collecting for changes                  JUL/94 p28   JUL/94 p55
  photographing your work                        * APR/94 p62   APR/94 p48
  policy manual for employees                      MAY/94 p25   MAY/94 p17
  profit not volume, to measure success            OCT/94 p28   OCT/94 p66
  remodelers, business tips for                    JAN/94 p37   JAN/94 p36
  slowdown, surviving a                            FEB/94 p23   FEB/94 p14
  specifications, simplified for small jobs      * MAR/94 p48   MAR/94 p38
  tax tips, for year-end savings                   DEC/94 p16   DEC/94 p18
  training programs help women enter trades        APR/94 p14   APR/94 p13
  warranty, Magnum Moss Act protect consumers      AUG/94 p22   AUG/94 p15
  warranty, writing your own                     * JUL/94 p73   JUL/94 p53
  workers comp, avoiding hidden costs            * JUN/94 p49   JUN/94 p44
  workers comp, speedy filing cuts costs           OCT/94 p13   OCT/94 p13
- CERAMIC TILE
  grout, non-pigmented won't stain tiles (P)       OCT/94 p103  OCT/94 p79
  shower shelf, one-piece backer (P)               NOV/94 p80   NOV/94 p66
  tile backerboard, working with                 * OCT/94 p69   OCT/94 p53
- CODES, BUILDING
  railing codes, current regs and changes        * JUN/94 p44   JUN/94 p38
- COMPUTERS
  CAD, for custom residential design               JUL/94 p19   JUL/94 p15
  digitizer, low-cost Scalex 1000 (P)              AUG/94 p63   AUG/94 p16
  estimating software, Quantum Leap (P)            JUL/94 p32   JUL/94 p57
  estimator, stick, Contractor's Dream (P)                      FEB/94 p48
  floor plan with client, Chief Architect (P)                   FEB/94 p47
  memory & file management using Windows           MAY/94 p28   MAY/94 p51
  Microsoft Office (P)                             OCT/94 p86   OCT/94 p67
  notes, paperless Info Select (P)                 DEC/94 p24   DEC/94 p20
  personal information managers                    MAR/94 p61   MAR/94 p49
  scheduling, simple software                      APR/94 p37   APR/94 p25
  utilities for Windows and Mac                    JUN/94 p66   JUN/94 p19
- CONCRETE & MASONRY
  brick veneer basics                            * JUN/94 p27   JUN/94 p23
  brick veneers, BIA advice (L)                    SEP/94 p7    SEP/94 p7
  cutting concrete walls (Q)                       OCT/94 p19   OCT/94 p18
  detergent used to ease concrete in chute         DEC/94 p11   DEC/94 p11
  insulated block used in Northeast                NOV/94 p14   NOV/94 p12
  rebar, standard for acceptable rust (Q)          AUG/94 p16   AUG/94 p12
- DRYWALL & PLASTER
  drywall, high-flex bendable (P)                  JAN/94 p64   JAN/94 p56
- ELECTRICAL
  grounding for surge protection                   FEB/94 p39   FEB/94 p27
  grounding water lines (Q)                        MAR/94 p21   MAR/94 p16
  lightning protection, low-cost design (L)        JUL/94 p6    JUL/94 p6
  lightning surge protection system              * FEB/94 p39   FEB/94 p27
  multiwire branch circuit receptacles (L)         DEC/94 p8    DEC/94 p8
  multiwire branch circuits (Q)                    SEP/94 p14   SEP/94 p15
  pumps, protect submersible from lightning        FEB/94 p42   FEB/94 p30
  stress-skin panels, wiring in (Q)                JAN/94 p22   JAN/94 p15
- ENERGY & CONSERVATION
  blower door basics                               APR/94 p89   APR/94 p71
  caulk & sealant tips & problems (L)              APR/94 p8    APR/94 p8
  electric power, Transtext energy management      JUL/94 p16   JUL/94 p12
  Energy Update - Issue Theme                    * AUG/94       AUG/94
  financing energy-efficient homes                 SEP/94 p86   SEP/94 p65
  geothermal push by government, industry          JAN/94 p10   JAN/94 p8
  housewrap, air leaks & moisture (L)              FEB/94 p5    FEB/94 p6
  steel framing & heat loss                        FEB/94 p74   MAR/94 p58
  steel framing, prevent thermal bridges (L)       NOV/94 p8    NOV/94 p7
  weatherproofing, cost effective by Oak Ridge     MAY/94 p14   MAY/94 p14
- FIREPLACES, CHIMNEYS, & WOOD STOVES
  chimney, modular HT-10 (P)                       SEP/94 p90   SEP/94 p69
  fireplace hearth details                       * NOV/94 p37   NOV/94 p31
  Rumford, outside air for (L)                     SEP/94 p7    SEP/94 p7
  Rumford, reviving the                          * MAR/94 p53   MAR/94 p43
- FOUNDATIONS & SITE WORK
  backfilling basics                             * OCT/94 p77   OCT/94 p59
  cold joint, sealing (Q)                          JUN/94 p15   JUN/94 p47
  foam backfill avoids soil subsidence             JUL/94 p16   JUL/94 p12
  foam form bracing cuts costs (L)                 AUG/94 p6    AUG/94 p5
  foam forms speed concrete curing (L)             FEB/94 p5    FEB/94 p4
  footings, Deck Plug pre-cast (P)                 MAR/94 p74   MAR/94 p61
  footings, fast forming for stepped             * MAR/94 p33   MAR/94 p25
  footings, guidelines for successful              MAR/94 p35   MAR/94 p27
  foundation drain and seal for wet sites (Q)      JUN/94 p15   JUN/94 p47
  foundation drain for wet sites, fabric (L)       OCT/94 p11   OCT/94 p11
  foundation drain placement details (L)           OCT/94 p8    OCT/94 p8
  foundation drain, holes up/down, pitch (Q)       JUL/94 p22   JUL/94 p18
  frost heaves, preventing                         JUL/94 p84   JUL/94 p68
  post and pier room additions                   * JUL/94 p37   JUL/94 p27
  rebar tips                                     * JUL/94 p59   JUL/94 p45
  retaining walls, Geogrid interlocking block      MAY/94 p68   MAY/94 p54
  Site Engineering, Simplified (B)                 MAR/94 p65   MAR/94 p52
  soil compaction basics                         * MAR/94 p27   MAR/94 p21
  Solid Foundations - Issue Theme                * MAR/94       MAR/94
  steel rebar/bolt/wire works with concrete        NOV/94 p69   NOV/94 p56
  water entry, basement, solutions (Q)             APR/94 p28   APR/94 p20
- FRAMING & STRUCTURE
  adhesives, a guide to construction             * SEP/94 p53   SEP/94 p43
  beach/coastal construction                     * APR/94 p41   APR/94 p29
  beam sizing, bending strength                    AUG/94 p72   AUG/94 p56
  beam sizing, for shear and deflection            SEP/94 p76   SEP/94 p60
  beam sizing, live plus dead load (L)             NOV/94 p8    NOV/94 p7
  bracing, truss trips                             MAR/94 p58   MAR/94 p47
  deck clip, Deckmaster (P)                        JAN/94 p62   JAN/94 p54
  deck planking, choosing lumber for (Q)           JUN/94 p15   JUN/94 p47
  dormers, building doghouse                     * OCT/94 p33   OCT/94 p25
  earthquake damage described in Los Angeles       APR/94 p11   APR/94 p11
  earthquake, APA report on plywood/OSB in LA      AUG/94 p9    AUG/94 p7
  Engineered Lumber - Issue Theme                * FEB/94       FEB/94
  fire-retardant trusses at risk                   FEB/94 p9    FEB/94 p7
  fire-retardant trusses, failure (L)              JUL/94 p6    JUL/94 p6
  fire-retardant trusses, moisture damage (L)      MAR/94 p6    MAR/94 p6
  floor framing with wood I-joists               * FEB/94 p29   FEB/94 p17
  Framing & Structure - Issue Theme              * APR/94       APR/94
  headers, building up with plywood (Q)            DEC/94 p21   DEC/94 p17
  hybrid framing with wood & steel               * JAN/94 p29   JAN/94 p37
  layout for fast framing                        * APR/94 p49   APR/94 p35
  lumber, non-toxic Pau Lope (P)                   JUN/94 p74   JUN/94 p60
  lumber, treated wood environmental O.K.          OCT/94 p13   OCT/94 p13
  lumber, treated wood study                       JAN/94 p13   JAN/94 p11
  lumber, working with Trex plastic-based        * AUG/94 p50   AUG/94 p40
  nail holding power, toe-nailed 8d's (L)          AUG/94 p6    AUG/94 p5
  nail size, number, space, type requirements    * FEB/94 p61   FEB/94 p50
  nails, guide to galvanized                     * NOV/94 p60   NOV/94 p48
  rafters, hip and valley sizing & support       * MAY/94 p36   MAY/94 p20
  rafters, hip and valley Southern method (L)      OCT/94 p8    OCT894 p
  roof panels, pre-fab vented Celo-Vent (P)        OCT/94 p104  OCT/94 p80
  rough framing, West Coast techniques (B)         MAR/94 p63   MAR/94 p51
  span tables, how to use                        * APR/94 p56   APR/94 p40
  splicing hips & valleys (Q)                      JAN/94 p22   JAN/94 p14
  steel framing & heat loss                        FEB/94 p74   MAR/94 p58
  steel framing, prevent thermal bridges (L)       NOV/94 p8    NOV/94 p7
  steel studs for wood framers (P)                 FEB/94 p79   FEB/94 p55
  wall framing, half-height basement             * SEP/94 p61   SEP/94 p51
- HEATING, COOLING, & DOMESTIC HOT WATER
  backdrafting issues, tight house (L)             NOV/94 p10   NOV/94 p8
  combining heating and cooling systems            OCT/94 p22   OCT/94 p19
  efficiency, how to measure AFUE & EF             DEC/94 p32   DEC/94 p28
  electric heat, programmable Ultrastat (P)        APR/94 p99   APR/94 p74
  forced hot air, adding on to                   * FEB/94 p47   FEB/94 p35
  furnace filter, choosing among types             MAY/94 p74   MAY/94 p56
  gas heat cheapest per DOE estimates              JUN/94 p8    JUN/94 p8
  heat pumps, ground-source                      * DEC/94 p37   DEC/94 p33
  HVAC, This Old (B)                               DEC/94 p67   DEC/94 p60
  Mechanical Systems - Issue Theme               * DEC/94       DEC/94
  radiant combined with baseboard (Q)              MAR/94 p20   MAR/94 p15
  sealed combustion, heating with                * DEC/94 p30   DEC/94 p26
  thermostat, easy-read (P)                        DEC/94 p74   DEC/94 p67
  ventilation using heat ducts & dampers (L)       JAN/94 p8    JAN/94 p6
- HOME INSPECTION
  earthquake damage described in Los Angeles       APR/94 p11   APR/94 p11
  egress windows required (L)                      JAN/94 p8    JAN/94 p6
  water in walls, three case studies             * AUG/94 p58   AUG/94 p46
- INSECTS & DECAY
  non-toxic insect powder (P)                      APR/94 p97   APR/94 p74
  sand barrier termite control                     MAR/94 p11   MAR/94 p11
  termite-control experiment results               OCT/94 p14   OCT/94 p14
  termite-control experiments in Calif. house      JAN/94 p9    JAN/94 p7
  termites & insulated foundations (Q)             FEB/94 p17   FEB/94 p15
- INSULATION & AIR SEALING
  basement walls, rigid foam for (P)               AUG/94 p79   AUG/94 p60
  cellulose, dry-pack improvements                 AUG/94 p33   AUG/94 p26
  cellulose, wet-spray installation              * AUG/94 p31   AUG/94 p24
  compressed batts, R-value of (Q)                 APR/94 p30   APR/94 p21
  fiberglass linked to cancer, weak evidence       SEP/94 p9    SEP/94 p9
  foam-core panels, borate treatment question      JUN/94 p8    JUN/94 p8
  foam-core panels, borate-treated answers         JUL/94 p6    JUL/94 p6
  loose-fill fiberglass, fixing R-value loss       OCT/94 p15   OCT/94 p15
  wall framing affects R-value                     SEP/94 p12   SEP/94 p12
  windows and R-values                             JUN/94 p40   JUN/94 p34
- INTERIORS & INTERIOR TRIM
  adhesive, subfloor suggestions (L)               DEC/94 p8    DEC/94 p8
  adhesives, a guide to construction             * SEP/94 p53   SEP/94 p43
  curved balcony, trimming a                     * FEB/94 p58   FEB/94 p32
  Fiberwood curved stairways (P)                   FEB/94 p79   FEB/94 p55
  finish carpentry quality standards             * DEC/94 p51   DEC/94 p47
  floors, glued wood (L)                           JAN/94 p7    JAN/94 p5
  floors, insulated over concrete (Q)              DEC/94 p18   DEC/94 p14
  floors, laying wide-pine                       * JUL/94 p66   JUL/94 p50
  floors, moisture control over concrete           OCT/94 p64   OCT/94 p50
  floors, sanding & refinishing wood             * NOV/94 p31   NOV/94 p25
  floors, wide pine is durable (L)                 SEP/94 p6    SEP/94
  floors, wide pine selection details (L)          OCT/94 p10   OCT/94 p10
  floors, wood over concrete slabs               * OCT/94 p63   OCT/94 p49
  hole filler, Erase-A-Hole (P)                    AUG/94 p82   AUG/94 p63
  moldings, flexible (P)                           OCT/94 p105  OCT/94 p81
  newell posts, fastening tips                   * MAY/94 p60   MAY/94 p4
  plaster grounds, proper backer board (L)         FEB/94 p5    FEB/94 p4
  trimless detailing solutions                     MAY/94 p20
  wainscot, frame-and-panel                      * JAN/94 p39   JAN/94 p31
- KITCHENS
  appliance specs by fax                           JUL/94 p12   JUL/94 p10
  backsplash, choosing a                           NOV/94 p65   NOV/94 p53
  cabinets, cup hinges and drawer slides         * SEP/94 p45   SEP/94 p32
  cabinets, hanging securely                       APR/94 p83   APR/94 p65
  catalog books for clients cut K&B bid time       FEB/94 p67   FEB/94 p53
  cooktops, what's new                             OCT/94 p89   OCT/94 p72
  countertop edge details                                       DEC/94 p63
  countertops, laminate tips (L)                   MAR/94 p7    MAR/94 p7
  countertops, solid surface instructions        * MAY/94 p43   MAY/94 p29
  Kitchen & Bath - Issue Theme                   * SEP/94       SEP/94
  kitchen design, 31 rules for                   * SEP/94 p31   SEP/94 p37
  kitchen design, client questionnaire             JUN/94 p61   JUN/94 p54
  marble, working with cultured                    AUG/94 p68   AUG/94 p51
  remodeling kitchens, design changes              JUL/94 p77   JUL/94 p61
- LEGAL & LEGISLATION
  arbitration authority not limited by court       JAN/94 p21   JAN/94 p18
  conditional bid acceptance not a contract        MAR/94 p18   MAR/94 p18
  corporations protect personal assets             APR/94 p21   APR/94 p17
  drinking on job-site, contractor liable          OCT/94 p82   OCT/94 p64
  expert witness, new guidelines for               FEB/94 p13   FEB/94 p10
  lien rights, protecting                          SEP/94 p18   SEP/94 p14
  OSHA paperwork requirements                      MAY/94 p24   MAY/94 p16
  shipping damage, who pays for                    JUN/94 p19   JUN/94 p17
  sued, what to do when being                      DEC/94 p22   DEC/94 p58
- LIGHTING
  fluorescents, dedicated compact fixtures         JAN/94 p60   JAN/94 p52
  recessed lighting, using baffles around          OCT/94 p94   OCT/94 p74
- MOISTURE, VENTILATION, & AIR QUALITY
  blower-door tests for house tightness            AUG/94 p39   AUG/94 p31
  exhaust fans & house depressurization            AUG/94 p40   AUG/94 p32
  fire-retardant trusses, moisture damage (L)      MAR/94 p6    MAR/94 p6
  heat-recovery ventilators                      * MAR/94 p39   MAR/94 p31
  roof ventilation, purposes for (L)               OCT/94 p11   OCT/94 p11
  sick-building linked to mineral fibers           MAY/94 p11   MAY/94 p11
  tight-house backdrafting issues (L)              NOV/94 p10   NOV/94 p8
  tight-house venting problems & solutions       * AUG/94 p37   AUG/94 p29
  vapor barrier, origins of polyethylene use       JUN/94 p9    JUN/94 p10
  vapor barriers, avoid sub-slab problems        * MAY/94 p54   MAY/94 p37
  ventilation using heat ducts & dampers (L)       JAN/94 p8    JAN/94 p6
- PAINTING & STAINING
  dropcloth, pretaped plastic (P)                  DEC/94 p77   DEC/94 p70
  exterior trim, proper finishes                   APR/94 p77   APR/94 p61
  Interior Finishes - Issue Theme                * NOV/94       NOV/94
  latex outlasts oil, per Forest Products Lab      SEP/94 p9    SEP/94 p9
  lead in painters' blood not correlated           FEB/94 p11   FEB/94 p9
  lead in painters' blood, safe levels (L)         MAY/94 p7    MAY/94 p7
  water-based polyurethanes, wood floors (Q)       APR/94 p30   APR/94 p21
- PLUMBING & SEPTIC
  antiscald code update                            JUL/94 p54   JUL/94 p42
  antiscald protection for showers               * JUL/94 p53   JUL/94 p41
  composting sink, EcoCycle (P)                    APR/94 p99
  electrical ground for water lines (Q)            MAR/94 p21   MAR/94 p16
  heat pump, new makes more hot water              NOV/94 p74   NOV/94 p62
  lead in well pumps, scare fades                  AUG/94 p12   AUG/94 p10
  plumbing problems, fix 12 most common          * OCT/94 p47   OCT/94 p35
  septic alternative for low-perk soils            APR/94 p12   APR/94 p12
  water line, insulate crawlspace entry (Q)        JAN/94 p22   JAN/94 p14
  water pressure problem diagnosis/fix             MAR/94 p66   MAR/94 p53
  water pressure, regulating city (L)              SEP/94 p6    SEP/94 p6
- REMODELING & RENOVATION
  business tips for remodelers                     JAN/94 p37   JAN/94 p36
  door, steel replacement in old jamb (P)          FEB/94 p82   FEB/94 p58
  floor protection during demolition (Q)           DEC/94 p19   DEC/94 p15
  flooring, tips for removing vinyl (Q)            MAY/94 p16   MAY/94 p15
  floors, wood over concrete slabs               * OCT/94 p63   OCT/94 p49
  Remodeling & Rehab - Issue  Theme              * OCT/94       OCT/94
  Remodeling & Renovation Cost Estimator (B)       JUN/94 p26
  Remodeling Production (B)                        JUN/94 p24
- ROOFING
  Advances in Roofing - Issue Theme              * MAY/94       MAY/94
  felt for fire-rating (L)                         JAN/94 p7    JAN/94 p5
  felt is a vapor barrier (L)                      APR/94 p7    APR/94 p7
  flashing, tile-roof skylights (Q)                AUG/94 p16   AUG/94 p12
  low-slope roofing, leakproof details           * MAY/94 p32   MAY/94 p20
  low-slope roofs, wood, slate, concrete tips    * MAY/94 p32   MAY/94 p20
  robot, Rapid Roofer (P)                          NOV/94 p16   NOV/94 p15
  shingle strengths vary by brand                  FEB/94 p13   FEB/94 p10
  stone veneer roof tile (P)                       NOV/94 p84   NOV/94 p69
  vents, low-profile slate (P)                     MAR/94 p77   MAR/94 p63
  wood roofs, fire protection                    * AUG/94 p53   AUG/94 p42
- SAFETY & HEALTH
  alarms, fire & toxic gas                         DEC/94 p61   DEC/94 p53
  back-supports, value debated                     JUN/94 p10   JUN/94 p11
  carpet toxicity test result questioned           SEP/94 p10   SEP/94 p10
  CO detectors                                     JUN/94 p70   JUN/94 p58
  fiberglass linked to cancer, weak evidence       SEP/94 p9    SEP/94 p9
  foam, polyisocyanurate health effects (Q)        DEC/94 p18   DEC/94 p14
  lead regulations database on disk                MAY/94 p13   MAY/94 p13
  lightning protection, low-cost design (L)        JUL/94 p6    JUL/94 p6
  lightning surge protection system              * FEB/94 p39   FEB/94 p27
  nail guns, correct air pressure (L)              SEP/94 p6    SEP/94 p6
  nail guns, working safely with                 * JUN/94 p57   JUN/94 p35
  OSHA inspections, preparing for                  NOV/94 p63   NOV/94 p18
  radon hazard: jumping to conclusions?            APR/94 p16   APR/94 p14
  safety responsibility, cannot subcontract        FEB/94 p26   FEB/94 p46
  security systems, home                         * DEC/94 p59   DEC/94 p51
  water, drinking, treatment alternatives        * JAN/94 p45   JAN/94 p41
  water, major contaminants                        JAN/94 p47   JAN/94 p43
  water, take the worry out of drinking          * JAN/94 p45   JAN/94 p41
- SIDING & EXTERIORS
  cedar shingle grading confusion                  NOV/94 p13   NOV/94 p11
  clear finish on exterior wood (Q)                OCT/94 p19   OCT/94 p18
  deadbolt, electronic (P)                         DEC/94 p76   DEC/94 p69
  deck cleaner, bleach-free (P)                    NOV/94 p82   NOV/94 p68
  entry, simple custom from stock materials      * JUN/94 p54   JUN/94 p42
  hardboard siding pulled from Florida market      MAY/94 p9    MAY/94 p9
  OSB panel bending strength (L)                   JUL/94 p7    JUL/94 p8
  OSB panel performance rating                   * FEB/94 p35   FEB/94 p23
  rail posts, attaching to decks                   DEC/94 p71   DEC/94 p65
  sheathing, APA stamp explained                   FEB/94 p37   FEB/94 p25
  shingle siding layout at windows (Q)             JUL/94 p21   JUL/94 p17
  siding stains & extractive bleeding in wood      NOV/94 p61   NOV/94 p49
  stucco cracks, preventing (Q)                    SEP/94 p16   SEP/94 p16
  trim that lasts, exterior                      * APR/94 p75   APR/94 p59
  wood siding, nail coating vs. staining (L)       APR/94 p7    APR/94 p7
  wood siding, pneumatic nailing problem (L)       JAN/94 p7    JAN/94 p5
- TOOLS & EQUIPMENT
  camera, heavy-duty ProCam Polaroid (P)           NOV/94 p80   NOV/94 p66
  caulk guns, high-performance                     SEP/94 p57   SEP/94 p47
  circular saw, Porter Cable 347 (P)               MAY/94 p86   MAY/94 p65
  combination square, Douglas Quad (P)             JUN/94 p82   JUN/94 p66
  dump truck kit for pickups (P)                   DEC/94 p74   DEC/94 p67
  dust mask cure for fogged glasses (Q)            MAY/94 p18   MAY/94 p15
  glue gun, hot-melt (P)                           JUL/94 p94   JUL/94 p74
  layout, fast tools for framing                   APR/94 p52   APR/94 p38
  sanders, triangle detail (P)                     NOV/94 p89   NOV/94 p72
  saws, new cordless (P)                           DEC/94 p81   DEC/94 p74
  Sawzall, super demolition saw (P)                MAR/94 p82   MAR/94 p66
  stand for mitre saw, Saw Helper (P)              SEP/94 p98   SEP/94 p74
  tight spots, tools for: saw, drill, etc (P)      OCT/94 p40   OCT/94 p30
  wall jacks, Proctor, lift safely (P)             JAN/94 p65   JAN/94 p58
  wormdrive saw, Skil 77 revised (P)               MAY/94 p90   MAY/94 p66
- WINDOWS, DOORS, & SKYLIGHTS
  balcony roof-window, Cabrio (P)                  MAR/94 p76   MAR/94 p63
  energy ratings, Certified Products Direct.       JAN/94 p14   JAN/94 p10
  low-E glazing, R-value, visibility, choices      JUL/94 p89   JUL/94 p65
  skylight wells, remodeler's guide              * AUG/94 p44   AUG/94 p36
  specialty windows (P)                            JUN/94 p37   JUN/94 p31
  window upgrade, innovative savings               MAY/94 p10   MAY/94 p10
  window-walls, two-story solutions (L)            JUN/94 p5    JUN/94 p6
  Windows & Exteriors - Issue Theme              * JUN/94       JUN/94
  windows and R-values                             JUN/94 p40   JUN/94 p34
  wood windows, shopping guide                   * JUN/94 p33   JUN/94 p27
********** LAST LINE *** ##### *** END OF FILE ************************

The design and content found at InspectAPedia.com® are © Copyright protected, All Rights Reserved. Contents of this website may not be copied in any form. Our main website topics listed at page left and page top provide in-depth, un-biased, expert information on building defect inspection, diagnosis, & repair.

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

InspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
AIR CONDITIONING & HEAT PUMPS
BOOKSTORE
ELECTRICAL
ENERGY SAVINGS
ENVIRONMENT
EXTERIORS
HEATING
HOME INSPECTION
INDOOR AIR QUALITY
INSULATION
INTERIORS
MOLD INSPECT/TEST/CLEANUP
NOISE
ODORS
PLUMBING
ROOFING
SEPTIC SYSTEMS
SOLAR ENERGY
STRUCTURE
VENTILATION
WATER SUPPLY

ACCURACY & PRIVACY POLICIES
EXPERT DIRECTORY
CONTACT

  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. Thanks to Alan Carson and Bob Dunlop, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education including the ASHI-adopted Home Inspection Training Program (home study course), publications such as the Home Reference Book, report writing materials including the Horizon report writer, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com 11/06
  • Roger Hankey is principal of Hankey and Brown home inspectors, Eden Prairie, MN. Mr. Hankey is a past chairman of the ASHI Standards Committee. Mr. Hankey has served in other ASHI professional and leadership roles. Contact Roger Hankey at: 952 829-0044 - rhankey@hankeyandbrown.com. Mr. Hankey is a frequent contributor to InspectAPedia.com.
  • Arlene Puentes, an ASHI member and a licensed home inspector in Kingston, NY, and has served on ASHI national committees as well as HVASHI Chapter President. Ms. Puentes can be contacted at ap@octoberhome.com

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson Dunlop The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop. The Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com