Federal Pacific Electric Stab-Lok, Square-D, Zinsco, & other electrical product warnings
Lightning protection system inspection & repair
Low voltage wiring, switches, controls, inspection, repair, replacement guide
Rust hazards in electrical panels
Our site offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
InspectAPedia.com/appointment.htm.
This website provides information about a variety of electrical hazards in buildings, with articles focused on the inspection, detection, and reporting of electrical hazards and on proper electrical repair methods for unsafe
electrical conditions.
We address safety for the electrical inspector, aluminum electrical wiring hazards, how to determine service voltage and ampacity, how to inspect electrical panels, and significant electrical
hazards of Federal Pacific Electric Stab-Lok breakers and panels, Federal Pioneer product warnings, certain Square-D product concerns, Zinsco and Sylvania circuit breakers and panels, multi-wire branch circuit protection, inspection and repair of low voltage wiring systems, and proper installation of lightning protection systems on buildings.
Aluminum Wiring Information Website Aluminum Electrical Wiring Hazards and Repairs: in-depth authoritative info, photos, documents including selection of proper vs. ineffective repair methods. E.g.: Ideal 65 "Twister" purple connector fails in field and lab testing with aluminum wire.
Ampacity and Voltage of an Electrical Service: How to determine the electrical service size or ampacity and service voltage (120/240) entering a Building
ARC FAULT CIRCUIT INTERRUPTERS: what are they, how do AFCI's work, where are they required to be installed? Also includes notes on GFCI's and the 2008 NEC electrical code.
Cadet Heaters Recall CPSC notice supplemented with identification and heater failure photos
Circuit Breaker, a bad one fails to trip failure at aluminum bus-to-circuit breaker connection - field report and photographs
Circuits, electrical: electric circuit basics for homeowners, electrical shorts, definitions of AC/DC, watts, amps, volts, etc.
DEFINITIONS of ELECTRICAL TERMS: Amps, Volts, Watts, Resistance and other electrical terms are defined and illustrated with sketches
DIRECTORY OF ELECTRICIANS: if you need to hire an electrician with special skills or familiarity with aluminum electrical wiring, FPE Stab-Lok replacement panels, Zinsco replacement panels, etc. here is a directory of professionals.
Electrical Panels, How to Inspect in Buildings, safety for electrical inspectors, electrical panel, fusing, wiring defects, defective products. Inspection Class Presentation
Federal Pacific Electric (FPE) Website Stab-Lok Circuit Breaker Panel Hazards Latent fire hazards, in-depth authoritative research, documents, advice on Stab-Lok electric panel and circuit breaker failures and what to do when this equipment is found in Buildings.
Low Voltage Electrical Wiring Repair & Replacement Guide for GEĀ®, Remcon, Sweepe, Bryant, Sierra, other brands, and newer Touch-PlateĀ® low voltage wiring systems. Low voltage lighting switches, relays, transformers, transconverters.
Outlet, how to install: guide for home owners & home inspectors - it's easy but important details make the difference between a safe installation of an electrical receptacle and one that is both dangerous and illegal.
Square D Circuit Breaker Recalls, announced by the US CPSC, recalls include a Square D GFCI circuit breaker distributed by Square D, and a Counterfeit Square-D circuit breaker sold through Scott Electric
Zinsco Electric Panel Replacements a discussion of repair (replacement) options for Zinsco Electrical Panels and Zinsco-type Sylvania Electric Panels
"Electrical System Inspection Basics," Richard C. Wolcott, ASHI 8th Annual Education Conference, Boston 1985.
"Simplified Electrical Wiring," Sears, Roebuck and Co., 15705 (F5428) Rev. 4-77 1977 [Lots of sketches of older-type service panels.]
"How to plan and install electric wiring for homes, farms, garages, shops," Montgomery Ward Co., 83-850.
"Home Wiring Inspection," Roswell W. Ard, Rodale's New Shelter, July/August, 1985 p. 35-40.
"Evaluating Wiring in Older Minnesota Homes," Agricultural Extension Service, University of Minnesota, St. Paul, Minnesota 55108.
"Electrical Systems," A Training Manual for Home Inspectors, Alfred L. Alk, American Society of Home Inspectors (ASHI), 1987, available from ASHI. [DF NOTE: I do NOT recommend this obsolete publication, though it was cited in the original Journal article as it contains unsafe inaccuracies]
"Basic Housing Inspection," US DHEW, S
352.75 U48, p.144, out of print, but is available in most state libraries.
Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
Additional technical contributors & reference sources for this article are listed below.
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
Our recommended books about building design, inspection, and repair, and about indoor environment testing, diagnosis, and cleanup are at the InspectAPedia Bookstore.
More Information on Building Diagnostic Inspections and Repairs
Links to our list of additional documents on electrical inspection, repair, and products
InspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
The Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.