Mobile ViewELECTRICAL INSPECTION, DIAGNOSIS, REPAIR AFCIs ARC FAULT CIRCUIT INTERRUPTERS ALUMINUM SECs & WIRING ALUMINUM WIRING HAZARDS & REPAIRS AMPS & VOLTS DETERMINATION AMPACITY - the LIMITING FACTOR APPLIANCE EFFICIENCY RATINGS BACKUP ELECTRICAL GENERATORS BOOKSTORE - ELECTRICAL BUILDING SAFETY HAZARDS GUIDE Cadet & Encore Heater Recall CIRCUIT BREAKER FAILURE Classified CIRCUIT BREAKER WARNING CIRCUIT BREAKER SIZE for A/C or HEAT PUMP Classified CIRCUIT BREAKER WARNING CUTLER HAMMER PANEL FIRE CONDUIT, ELECTRICAL CORROSION in ELECTRICAL PANELS CORROSION & MOISTURE SOURCES in PANELS DEFINITIONS of ELECTRICAL TERMS Definition of Amps, Electrical Current Definition of Electrical Circuits, shorts Definition of Volts Definition of Watts How a Building Gets 240V and 120V How many Watts in a Circuit Definition of AC Alternating Current Definition of DC Direct Current Definition of Electrical Ground Terms Definition of Electrical Potential Definition of Ohms, Electrical Resistance Efficiency of 120V vs 240V Equipment DIRECTORY OF ELECTRICIANS DIRECTORY OF ELECTRICIANS - Aluminum Wiring DIRECTORY OF ELECTRICIANS - FPE Zinsco ELECTRIC HEAT ELECTRIC METERS & METER BASES ELECTRIC MOTOR DIAGNOSTIC GUIDE ELECTRIC MOTOR OVERLOAD RESET SWITCH ELECTRIC PANEL AMPACITY ELECTRIC PANEL INSPECTION ELECTRIC PANEL MOISTURE Electric Power Frequency Table ELECTRICAL BASICS Electricity Basics - how it works Electrical Circuit ID, Map & Label Electrical Circuits, shorts Electrical Code Basics ELECTRICAL CONDUIT Electrical Definitions Electrical Grounding Basics Electrical Outlet-how to add Electrical Splices, how to make Electrical Tools & Tests Electrical Wire Stripping Tips Electrical Wiring Books & Guides Electrical Wiring in Old Houses Old House Electrical Grounding EMF RF FIELD & FREQUENCY DEFINITIONS ENERGY SAVINGS in buildings ELECTRICAL GENERATORS ELECTRICAL GROUND SYSTEM INSPECTION Gas Piping Ground Bond TABLE OF GROUND WIRE SIZES Old House Electrical Grounding False Ground at Receptacles False Neutral Connections Case History: Double Fault Leads to Loss of Power Case History:Loss of Neutral Shocks Homeowner Electrical Service Grounding Checklist Why Grounding is Needed ELECTRICAL SYSTEM GROUNDING SERVICE GROUNDING DEFECTS TABLE OF GROUND WIRE SIZES Old House Electrical Grounding FEDERAL PACIFIC FPE HAZARDS FIRE SAFETY Checklist, CPSC GENERATORS, ELECTRICAL GFCI PROTECTION,Testing GFCIs AFCIs HEATING COST FUEL & BTU Cost Table HEAT, ELECTRIC HEAT TAPE USAGE GUIDE Hertz - Definitions of KHz MHz GHz THz KNOB & TUBE WIRING LIGHTING, INTERIOR GUIDE LIGHTNING PROTECTION SYSTEMS LOW VOLTAGE BUILDING WIRING MAIN DISCONNECT MAIN DISCONNECT AMPACITY MOISTURE SOURCES in PANELS MULTI-WIRE CIRCUITS MURRAY SIEMENS Recall PHOTOVOLTAIC POWER SYSTEMS PUSHMATIC - BULLDOG PANELS REMOTE ELECTRIC POWER, PHOTOVOLTAIC RUST in ELECTRICAL PANELS SAFETY FOR ELECTRICAL INSPECTORS Shock Risk Statistics Outside Electrical Inspection Electric Meter & Service Entry Local Electrical Grounding Electrical Panel Interior Inspection Removing Electric Panel Covers Electrical Panel Cover Screws Electrical Panel Interior Hazards Testing Main Breakers or Fuses Inspect Breakers, Fuses, Circuits Testing Receptacles GFCIs AFCIs When to Shut Down Equipment Touching Electrical Equipment Guide to Electrical Test Equipment Using DMMs & VOMs Safely Voltage Measurement & Detection General Electrical Safety Suggestions Electrical Inspection Client Safety SE CABLE SIZES vs AMPS SIEMENS MURRAY Recall SOLAR ENERGY SYSTEMS SQUARE-D RECALLS UNDERGROUND SERVICE LATERALS VOLTAGE MEASUREMENT EQUIPMENT WIND ENERGY SYSTEMS WIND TURBINES & LIGHTNING ZINSCO / SYLVANIA HAZARDS More Information |
This article answers basic questions the National Electric Code (NEC) for homeowners. Readers of this article should also see ELECTRICAL DEFINITIONS and also SAFETY FOR ELECTRICAL INSPECTORS. This website provides information about a variety of electrical hazards in buildings, with articles focused on the inspection, detection, and reporting of electrical hazards and on proper electrical repair methods for unsafe electrical conditions. Critique and content suggestions are invited. Credit is given to content editors and contributors. © Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.
Electrical Code Advice for Homeowners & DIY RepairsElizabeth Sluder and Daniel Friedman Why we Must Follow the National Electrical Code When Performing Electrical WorkBuilding code enforcement authorities and local laws in many communities require that electrical work be performed only by a licensed electrician. In some communities local laws permit certain electrical work to be done by the homeowner without a permit and without conflict with local codes. Contact your city or village building department for a copy of local regulations. In any case, any electrical work, new wiring, repairs, replacements of parts, must comply with the requirements of both local laws and the National Electrical Code. Since the electrical code is written by experts and since the "code" is intended to assure that electrical wiring in a building is functional, adequate, and most of all, safe, not only should electrical work comply with the code to be legal, it should comply with the code to be safe. Electrical work by the homeowner might affect not only safety but also fire insurance coverage. If a fire loss claim results from wiring you installed, the company may classify you in a higher risk category or in some cases your insurance company may fail to honor your claim entirely. The NEC - National Electric CodeThe National Electrical Code Book provides thorough, very detailed instructions for determining the adequacy of an electrical wiring system and is written intending to guide a professional electrician (not a homeowner) in the safe repair and modification of electrical systems such as lighting, receptacles, and electrical wiring. The chances are your house wiring was safe and adequate when your house was built. It is probable, too, that your house wiring was originally done in accordance with the National Electrical code. This code was developed by the National Fire Protection Association and is revised from time to time. The code itself has legal status only insofar as it has been adopted by cities, towns, counties, and other governmental units as part of local building ordinances. The status of the code in your locality can be determined by contacting the building inspection department of your local government. The NEC does not give step by step instructionsThe National Electrical Code does not provide step-by-step instruction. Rather, the code specifies the preferred method of performing electrical wiring tasks and the proper materials to use in various in various applications. Incidentally, the code does not limit or prohibit electrical work by a homeowner, but as we explained above, local laws may require that you hire a licensed electrician. Beware: understanding the electrical code requires some expertise. Even licensed electricians often buy a version of the National Electric Code which includes explanations, interpretations, and sketches to help clarify the details of safe electrical wiring practices. Most home electrical work is surprisingly easy to do; the system is logical; replacement parts are standardized so they will fit anywhere in the U.S. Where to Obtain the National Electrical CodeThe NEC is published by the National Fire Protection Association (NFPA) and can be easily obtained from that association directly as well as from lots of online book-sellers. The NEC is also available to read online as an electronic document as well as in the form of a large (1000 page) bound book. The text remains © protected property of NFPA however. So to print the text you need to buy the CD ROM of the code from NFPA, or buy the book itself. Copies of the electrical code are probably also available at your local library. Copes are often on sale in electrical supply stores and in some book stores. A somewhat simplified version of the electrical code, known as the "One- and Two-Family Residential Occupancy Electrical Code," less costly than purchasing the entire NEC. The simplified edition covers the most popular and widely used wiring methods. The Canadian Electrical CodeThe Canadian Standards Association (CSA) has been publishing the Canadian Safety Standard for Electrical Installations since 1927. This document forms the basis for electrical codes adopted in the individual Canadian provinces. The U.S. and Canadian electrical codes differ in some technical details but are slowly merging. The 2006 Canadian Electrical Code draws from the International Electrotechnical Commission (IEC) Standard 60364, the European standard for electrical wiring. The United Kingdom Electrical CodeIn the U.K., electrical wiring is specified by the UK Institution of Engineering and Technology (IET) in IEE Wiring Regulations BS 7671 which, like the CSA code, draw on IEC 60634. In Australia and New Zealand, electrical wiring is specified by the wiring rules in AS/NZS 3000. Examples of Electrical Code Requirements that Homeowners Should KnowHow to select the proper electrical junction boxElectrical codes require that all wire connections or cable splices be inside an approved metal or plastic box. You cannot bury a box inside a wall - that is, you cannot hide or cover over a junction box with a finished surf race like drywall or paneling. The junction boxes in a home must all must be accessible. This protects your home from the danger of fire and makes it easier to inspect and upgrade your wiring in the future. The size, shape, and type of electrical junction box you need to choose depends on what it's for. Boxes vary in size, depth, and material. The junction box you need to use to join wires together in an attic for a splice is not the same shape as a box you need to use to install a single electrical outlet. Even the choice of a single junction box to install a single electrical outlet on an existing electrical circuit will be affected by the number of electrical wires that have to enter the box (more wires need more cubic inches of space to be wired safely). These details are spelled out in the National Electrical code as well as in subsets of the code written and amplified to guide installers of residential electrical wiring. Adding or Wiring an Electrical OutletA very common homeowner task that some people tackle is replacing a worn electrical outlet, or more complicated, adding a new electrical outlet in a building. While this task is not difficult, if it is not done properly there can be a real risk of fire or shock or even a fatality. See Electrical Outlet-how to add for an example of a simple task that has more details that need to be correct than you may have thought. How to Connect Multiple Wires to a single terminal on a switch or electrical outletNever attach more than one wire to a terminal. Codes prohibit it, and it's unsafe because terminal screws are made to hold only one wire. An easier way to join many wires to a terminal is to cut a short piece of wire (about 4 inches), strip both ends, and splice it to the other wires to form a pigtail. See Electrical Splices, how to make for details of the proper procedure for splicing wires together. How & Why It is Important to Assure Safe Electrical Grounding at a PropertyHome inspector Arlene Puentes summarizes distinctions important in understanding the function of electrical grounding at a building:
See ELECTRICAL GROUND SYSTEM INSPECTION for a detailed example of the importance of proper electrical ground connections and of what can go wrong if the electrical ground wiring is faulty. See Electricity Basics - how it works for a very basic explanation of electricity. See DEFINITIONS of ELECTRICAL TERMS for more explanation of electrical potential or volts. In that section, see Definitions of Electrical Equipment Ground, Grounded Electrical Conductor, Ground, Ground Rod & Ground Bond for details. What Authorities or Certifications Make Electrical Components Legal for Use ?Listed Electrical Equipment: as defined in the U.S. National Electrical Code (NEC) (CSA provides similar terms) as: equipment, materials, or services included in a list published by an organization that is acceptable to the authority having jurisdiction and concerned with evaluation of products or services, that maintains periodic inspection of production or listed equipment or materials or periodic evaluation of services, and whose listing states that the equipment, material, or services either meets appropriate designated standards or has been tested and found suitable for a specific purpose. In simpler terms this means that listed electrical equipment (circuit breakers, wires, connectors, switches, receptacles, and more) has been tested by someone whose procedures are acceptable to your state, provincial, or city or town electrical inspectors. By implication, an electrical part that has not been listed may not be approved for use in a building, and by implication, may be unsafe. Labeled Electrical Equipment is equipment or materials to which has been attached a label, symbol, or other identifying mark of an organization that is acceptable to the authority having jurisdiction and concerned with product evaluation, that maintains periodic inspection of production of labeled equipment or materials, and by whose labeling the manufacturer indicates a compliance with appropriate standards or performance in a specified manner. In practice we've seen a range of care in the application of standards, testing, listing, and supervision, in the listing and labeling of electrical products, extending from serious, responsible, and proper, to improper and downright dangerous over the history of electrical products. An example of improper labeling practices was documented in the history of the FPE Stab-Lok electrical panels and circuit breakers: the manufacturer lost their UL label for a time after getting caught placing labels on equipment where they did not belong. See FEDERAL PACIFIC FPE HAZARDS for details. The UL Seal provided by Underwriters Laboratories for electrical partsAn example of a long-established listing organization for electrical products is Underwriters Laboratories, founded in 1894 by William H. Merrill, an electrical engineer who supported the development of electrical standards, testing, and protection from electrical hazards. Originating in the United States, UL has facilities in more than 100 countries. Underwriters' Laboratories Inc. is a nonprofit organization that performs tests on electrical products. If an item meets minimum safety standards avoidance of fire and shock, it is listed with the Underwriters' Laboratories. Listed items display the UL seal on the item or on its package. This indicates minimum compliance standards. Products having a wide variety of prices may all have the UL seal. Higher priced items will generally have additional features for convenience or longer life. Questions & Answers regarding this article. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. ELECTRICAL BASICS