InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Indoor
Environment
| Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
Directory of Professionals to Inspect or Test a Building

ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR

AFCIs ARC FAULT CIRCUIT INTERRUPTERS
ALUMINUM SECs & WIRING
ALUMINUM WIRING HAZARDS
AMPS & VOLTS DETERMINATION
AMPACITY - the LIMITING FACTOR
APPLIANCE EFFICIENCY RATINGS
BOOKSTORE - ELECTRICAL
CIRCUIT BREAKER FAILURE
Classified CIRCUIT BREAKER WARNING
DEFINITIONS of ELECTRICAL TERMS
DIRECTORY OF ELECTRICIANS
ELECTRIC METERS & METER BASES
AMPACITY - the LIMITING FACTOR
ELECTRIC PANEL AMPACITY
ELECTRIC PANEL INSPECTION
ELECTRICAL BASICS
ENERGY SAVINGS in BUILDINGS
FEDERAL PACIFIC FPE HAZARDS
GROUND SYSTEM INSPECTION
KNOB & TUBE WIRING
LIGHTNING PROTECTION
LOW VOLTAGE BUILDING WIRING
MAIN DISCONNECT AMPACITY
MULTI-WIRE CIRCUITS
PUSHMATIC - BULLDOG PANELS
RUST in ELECTRICAL PANELS
SAFETY FOR ELECTRICAL INSPECTORS
SE CABLE SIZES vs AMPS
SQUARE-D RECALLS
UNDERGROUND SERVICE LATERALS
VOLTAGE MEASUREMENT EQUIPMENT
ZINSCO SYLVANIA ELECTRICAL PANELS
ADVICE FOR ZINSCO OWNERS
  ZINSCO SAFETY PRECAUTIONS
  SIGNS OF ZINSCO GTE SYLVANIA TROUBLE
IDENTIFY ZINSCO ELECTRICAL PANELS
IDENTIFY GTE SYLVANIA-ZINSCO PANELS
IDENTIFY ZINSCO SYLVANIA METER BASE
IDENTIFY KEARNEY PANELS
GTE-SYLVANIA-ZINSCO FAILURE MECHANISM
ZINSCO FAILURE PHOTOGRAPHS
ZINSCO FAILURE REPORTS
HOW TO REPORT ELECTRICAL FAILURES
  REPORT TO WEB AUTHOR
  REPORT TO THE US CPSC
  ZINSCO INSPECTION REPORT LANGUAGE
REPAIR ELECTRICIANS
REPLACEMENT ELECTRICAL PANELS
ZINSCO WARRANTY & CONTACT INFO

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Zinsco Electrical Panel, Zinsco Circuit Breakers - Warranty & Contact Information
InspectAPedia®  -    

  • Warranty, Replacement, Recall, and Contact Information for Zinsco or GTE-Sylvania-Zinsco Electrical Panels & Circuit Breakers
  • List of electricians familiar with Zinsco electric panel replacement
  • Field reports indicate severe failures of Zinsco electrical panels / circuit breakers
  • What are the hazards of Zinsco or Zinsco-Sylvania electric panels?
  • How should these panels be repaired: electrical panel replacement alternatives
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

Here we provide contact information for Zinsco and Zinsco Sylvania electrical panels. This website discusses the electrical, fire, and shock hazards associated with Zinsco electrical components, circuit breakers, electrical panels, including certain Sylvania electrical panels and breakers which are in fact of the same product design and origin.

© Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Warranty or Recalls for Zinsco Electrical Panels

Zinsco warranty claims Contact: we are unaware of any recall or warranty coverage that is available for Zinsco electrical equipment.

For Zinsco Electrical Panel replacement and replacement options that may save you some money, see
REPLACEMENT ELECTRICAL PANELS
REPAIR ELECTRICIANS

Contact Information for Zinsco or Sylvania-Zinsco Electrical Company - Osram Sylvania

Zinsco Electric is not a going concern and it is unlikely that you will find direct contact information for "the Zinsco Corporation".

As Zinsco products were later marketed through the Osram Sylvania Electric Corporation, and GTE-Sylvania and because we've had occasional requests from prior employees of Zinsco Corporation or their families for assistance in contacting their prior employer or for employment records, we provide, below, contact information for the Sylvania Corporation. Readers should be aware that information and photographs describing failures of GTE-Sylvania-Zinsco equipment pertain only to that product line and not to other GTE or Sylvania products.

Corporate Website for Sylvania Corporation: www.sylvania.com
North American Headquarters
100 Endicott Street
Danvers, MA 01923
USA
Phone: 978-777-1900
Fax: 978-750-2152

Zinsco or Sylvania Employment Records, Pensions, or other employment records: most companies keep employee records indefinitely. Even if you or a family member worked for Zinsco Corp. before that product line was picked up by Sylvania, Sylvania Corporation may have received and kept those employment records. You should contact Sylvania with any such requests for employment information.

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ZINSCO SYLVANIA ELECTRICAL PANELS
ADVICE FOR ZINSCO OWNERS
  ZINSCO SAFETY PRECAUTIONS
  SIGNS OF ZINSCO GTE SYLVANIA TROUBLE
IDENTIFY ZINSCO ELECTRICAL PANELS
IDENTIFY GTE SYLVANIA-ZINSCO PANELS
IDENTIFY ZINSCO SYLVANIA METER BASE
IDENTIFY KEARNEY PANELS
GTE-SYLVANIA-ZINSCO FAILURE MECHANISM
ZINSCO FAILURE PHOTOGRAPHS
ZINSCO FAILURE REPORTS
HOW TO REPORT ELECTRICAL FAILURES
  REPORT TO WEB AUTHOR
  REPORT TO THE US CPSC
  ZINSCO INSPECTION REPORT LANGUAGE
REPAIR ELECTRICIANS
REPLACEMENT ELECTRICAL PANELS
ZINSCO WARRANTY & CONTACT INFO

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building design, inspection, and repair, and about indoor environment testing, diagnosis, and cleanup are at the InspectAPedia Bookstore.
  • Recommended books on electrical inspection, electrical wiring, electrical problem diagnosis, and electrical repair can be found in the Electrical Books section of the InspectAPedia Bookstore. (courtesy of Amazon.com)
  • Electrical System & Wiring Hazard Inspection, Detection, Cause, Remedy, Prevention
  • ** Safety Hazards and Safe Electrical Inspection Procedures for Electrical and Home Inspectors at Residential Electric Panels
  • Aluminum Wiring Information Website Aluminum Electrical Wiring Hazards and Repairs: in-depth authoritative info, photos, documents including selection of proper vs. ineffective repair methods. E.g.: Ideal 65 "Twister" purple connector fails in field and lab testing with aluminum wire.
  • Electrical Panels, How to Inspect in Buildings, safety for electrical inspectors, electrical panel, fusing, wiring defects, defective products. Inspection Class Presentation
  • Rust and Corrosion in Electrical Panels, A Study and Report on Frequency and Cause for Electrical and Home Inspectors at Residential Electric Panels
  • ...
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
ZINSCO SYLVANIA PANELS

More Information


InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us

More Information on Building Diagnostic Inspections and Repairs

  • ...
InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

11/26/2009 - 12/21/2006 - InspectAPedia.com/electric/ZinscoContact.htm - © 2010 - 2006 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark