InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile Phone/PDA website viewMobile View
EXTERIORS of buildings

ADHESIVES, EXTERIOR CONSTRUCTION
AGE of a BUILDING - how to determine
ALGAE, FUNGUS, LICHENS, MOSS
ANIMAL ENTRY POINTS in buildings
ANIMAL ODORS IN buildings
ARCHITECTURE & BUILDING COMPONENT ID
ASBESTOS ROOFING / SIDING DUST
ATTIC CONDENSATION CAUSE & CURE

BARK SIDE DOWN on DECKS, TRIM, STEPS
BASEMENT WATERPROOFING
BEST CONSTRUCTION PRACTICES GUIDE

BRICK FOUNDATIONS & WALLS
BRICK STRUCTURAL WALL Loose Bulged
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BOOKSTORE - EXTERIORS
BUILDING SAFETY HAZARDS GUIDE
BUILDING SETTLEMENT

CAULK GUN TYPES, CHOICES
CAULKS & SEALANTS, EXTERIOR
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CATCH BASINS

DECK & PORCH CONSTRUCTION
DECK FINISHES COATINGS PRESERVATIVES
DEFINITIONS of ENGINEERED WOOD OSB LVL etc
DRYWELLS, FRENCH DRAINS for FLAT SITES

EARTHQUAKE DAMAGED FOUNDATIONS
ENERGY SAVINGS in buildings
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY
EXTERIOR WALL SIDING TRIM & FINISHES

FLASHING MEMBRANES PEEL & STICK
FLASHING for METAL ROOFS
FLASHING ROOF WALL DETAILS
FLASHING ROOF-WALL SNAFU
FLASHING SIDING DETAILS
FLASHING WALL DETAILS
FLASHING WOOD ROOF DETAILS
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FROST HEAVES, FOUNDATION, SLAB
FOOTING & FOUNDATION DRAINS
FOUNDATION WATERPROOFING
FRENCH DRAINS

GALVANIC SCALE & METAL CORROSION
GLUES ADHESIVES, EXTERIOR CONSTRUCTION
GRADING & SITE WORK, EXTERIOR
GUTTERS & DOWNSPOUTS

HEAT TAPES & CABLES on Roofs for Ice Dams
HOUSE PARTS, DEFINITIONS
HOUSEWRAP INSTALLATION DETAILS
HUMIDITY LEVEL TARGET

ICE DAM PREVENTION
INDOOR AIR QUALITY & HOUSE TIGHTNESS

KIT HOMES, Aladdin, Sears, Wards, Others

LEAD POISONING HAZARDS GUIDE
LEED GREEN BUILDING CERTIFICATION
LOG HOME GUIDE
LIGHTNING PROTECTION

METAL LATH, PLASTER & STUCCO
MOISTURE CONTROL in BUILDINGS
MOISTURE CALCULATIONS
MOISTURE PROBLEMS: CAUSE & CURE
MOLD DETECTION & INSPECTION GUIDE
MVOCs & MOLDY MUSTY ODORS

ODORS & SMELLS DIAGNOSIS & CURE
OIL TANKS

PAINT & STAIN GUIDE, EXTERIOR
PAINT & STAIN LIFE CHART
PAINT & STAIN SELECTION & PROCEDURES
PAINT ANALYSIS, DIAGNOSTIC USES
PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PAINT FAILURE DICTIONARY
PAINT LAB SAMPLE PREPARATION
PAINT SURFACE PREPARATION
PAINTING MISTAKES
PORCHES & Sunrooms
PORCH CONSTRUCTION & SCREENING

RAILINGS, DECK & PORCH
RAILINGS, STAIRWAY
RETAINING WALL DESIGNS, TYPES, DAMAGE
RETAINING WALL GUARD RAILINGS

ROOF CLEANING RECOMMENDATIONS
ROOF VENTILATION SPECIFICATIONS
ROT, FUNGUS, TERMITES
ROT, TIMBER FRAME

SEARS KIT HOUSES
SEPTIC & CESSPOOL SAFETY
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
SHEATHING, Gypsum board
SHEATHING Homasote & Other Board
SHEATHING, OSB
SHEATHING, Plywood
SHEATHING, FOIL FACED - VENTS
SIDING, Sheathing Identification - Photo Guide
SIDING, ALUMINUM
SIDING, ASBESTOS FIBER CEMENT
SIDING ASPHALT ROOF SHINGLES on WALLS
SIDING ASPHALT SHINGLE or SHEET
SIDING DAMAGE by SPLASHBACK

SIDING EIFS & STUCCO
SIDING, FIBER CEMENT
SIDING HARDBOARD
SIDING STEEL
SIDING VINYL
SIDING, WOOD PRODUCT CHOICES
SIDING, WOOD INSTALLATION
SIDING WOOD, FAILURES OVER FOAM BOARD
SIDING WOOD, FLASHING DETAILS
SIDING WOOD SHINGLE INSTALLATION

SINKHOLES, WARNING SIGNS
SOLAR ENERGY SYSTEMS
SOUND CONTROL in buildings

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAINS & Thermal Tracking
STAIN DIAGNOSIS on ROOFS
STAIN DIAGNOSIS on STONE
STAIRS, RAILINGS, LANDINGS, RAMPS
  Attic stairs
  Balusters & Railing Enclosures
  BARK SIDE DOWN on DECKS, TRIM, STEPS
  Basement Stairs & Walkout Covers
  Books on Stair Construction
  Checklist for Stair Inspections
  Circular & Curved Stairs
  Codes for Stairs
  Color / Lighting Cues Avoid Trip Hazards
  Deck & Porch Steps or Stairs
  Deck & Porch Railings
  Entry & Stairway Platforms, landings
  Exterior Stairs
  Exterior Stair Falls
  Guardrails on Balconies & Landings
  Lighting over Stairs
  Pet Stairs & Pet Ramps
  Railings on Stairways
  Ramps, access
  Stair dimensions: width height &c
  Stairway headroom
  Stairway landings
  Stair stringer defects
  Step riser dimensions
  Step tread dimensions
  Stair tread nose dimensions
  Winder stairs
STAIR FALL & TRIP HAZARDS
STONE CLEANING METHODS
STONE VENEER WALLS
STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES

SURFACE GRADING, SITE DRAINAGE

TERMITES, ROT
THERMAL EXPANSION of MATERIALS
THERMAL MASS in buildings
TREES & SHRUBS, TRIM OFF BUILDING
TRIM, EXTERIOR CHOICES, INSTALLATION

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in buildings
VINYL Siding or PLASTIC Window ODORS in buildings
VINYL CHLORIDE HEALTH INFO

WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in buildings
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
WINDOWS & DOORS
WINTERIZE A BUILDING

More Information

Amateur exterior stair & deck construction (C) D Friedman Exterior Stairways: Guide to Outdoor Stair, Railing, Landing Construction & Inspection
InspectAPedia®  -      

  • Exterior or Outdoor Stair, railing, guardrail, landing, tread, and step specifications & codes
  • Construction Requirements for Safe Outdoor Steps, Stairs, Railings, Newell Posts - exterior stair trip & fall hazards
  • Outdoor Stair & railing safety hazards, photos of defects; Defects in Masonry Steps and Landings Outdoors
  • Sketches of exterior stair design requirements
  • Questions & answers about Exterior Stair Code Specifications & Construction

Exterior stairway construction, codes, specifications: this document provides building code specifications, sketches, photographs, and examples of defects used in inspecting indoor or outdoor stairs, railings, landings, treads, and related conditions for safety and proper construction

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Exterior Stair Code Specifications & Construction Recommendations

Amateur exterior stair & deck construction (C) D FriedmanA stair inspection checklist provided in this document outlines information to collect during a field investigation of the condition of an interior or exterior stairway for safety defects. Having investigated cases of severe injury related to falls and railing collapses we developed this field data collection checklist

See Catalog of Stair Trip Fall Hazards and Exterior Stair Falls, where we catalog most exterior stair slip trip and fall hazards;

Also see Stairway landings and Deck & Porch Steps or Stairs.

For code specification details for steps, stairs, & railings, see Codes for Stairs

While in general the building code specifications for exterior stairs, landings, and railings are the same as for indoor star is, we often see special trip hazards at exterior stairs and walks, conditions that do not occur indoors, and details which may escape some building inspectors.

When we encounter steps and a deck such as the versioj shown in our photo (above left) we are confident that the construction was done without the benefit of building permits and code approvals, is unsafe, and may harbor other hidden structural or safety hazards.

And some stair design requirements, such as stair treads that will not hold water, naturally pertain principally to outdoor stairways. We add some more subtle warnings about outdoor stairs and stair construction, and tips or tricks of carpentry and masonry to avoid problems with stairs.

Construction Requirements for Safe Outdoor Steps, Stairs, Railings, Newell Posts

Stair support unsafe (C) Daniel Friedman Stair support unsafe (C) Daniel Friedman
  • Proper structural support for the stair assembly is critical to avoid catastrophic failures and serious injuries. Our two stair photos just above show a large, complex exterior stair built along a rocky hillside - more of a cliff. The lack of connection of supporting posts to piers below this stair was appalling.
  • Proper exterior stair tread drainage: Outdoor stairs should be designed so as not to accumulate water on the tread surface Wet stair tread surfaces become slippery from water, ice, or algae and fungal growth.
Figure 1-31: Cupping of flat sawn lumber (C) Wiley and Sons, S Bliss
  • Wooden stair treads should be installed with the end grain curve "down". Notice the end-grain of boards to be used as stair treads, and make sure that when building a wooden outdoor stair tread you place the tread boards with the "bark side" down - the wood grain visible at the end of stair tread boards should arc down.

    (Sketch courtesy S. Bliss, Best Practices in Residential Construction.)

    That determines the natural curvature of the tread board as the wood dries, and it makes for the best stair tread drainage and the minimum cupping or or holding of water on the stair tread.
  • If a board misbehaves and cures with a cup, drill small drainage holes in the center of the cupped board. Make sure the drain holes won't catch a high-heeled shoe by making them small or locating them out of the walking path.

Exterior Stairs - Incomplete, Unsafe, Missing Guardrails

Indoor light fixture used outside (C) Daniel Friedman

This exterior stair appears to have been installed as a fire-exitway, but lacks a guardrail around the stair top balcony.

It is exactly during an emergency that a frightened user is more likely to fall at this location.

Questions & Answers regarding this article

Questions & answers about Exterior Stair Code Specifications & Construction.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

STAIRS, RAILINGS, LANDINGS, RAMPS
  Attic stairs
  Balusters & Railing Enclosures
  BARK SIDE DOWN on DECKS, TRIM, STEPS
  Basement Stairs & Walkout Covers
  Books on Stair Construction
  Checklist for Stair Inspections
  Circular & Curved Stairs
  Codes for Stairs
  Color / Lighting Cues Avoid Trip Hazards
  Deck & Porch Steps or Stairs
  Deck & Porch Railings
  Deck & Porch Products, Manufacturers
  FRAMING CONNECTORS & JOIST HANGERS
  FRAMING FASTENERS, NAILS, SCREWS, & HIDDEN
  Finishes, Coatings, Stains for Decks
  Porch Construction & Porch Screening
  Preservative-Treated Framing Lumber
  Rooftop Deck Construction
  Rot-Resistant Deck Lumber & Flooring
  Synthetic Deck Lumber: Composite, Plastic, Vinyl
  Exterior Stairs
  Exterior Stair Falls
  Fire Stopping for Stairways
  Guardrails on Balconies & Landings
  Lighting over Stairs
  Railings on Stairways
  Ramps, access
  Stair dimensions: width height &c
  Stairway headroom
  Stairway landings
  Stair stringer defects
  Step riser dimensions
  Step tread dimensions
  Stair tread nose dimensions
  Winder stairs

  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. Thanks to Alan Carson and Bob Dunlop, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education including the ASHI-adopted Home Inspection Training Program (home study course), publications such as the Home Reference Book, report writing materials including the Horizon report writer, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson Dunlop The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop. The Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
  • "The Elimination of Unsafe Guardrails, a Progress Report," Elliott O. Stephenson, Building Standards, March-April 1993
  • "Are Functional Handrails Within Our Grasp" Jake Pauls, Building Standards, January-February 1991
  • Access Ramp building codes:
    • UBC 1003.3.4.3
    • BOCA 1016.3
    • ADA 4.8.2
    • IBC 1010.2
  • Access Ramp Standards:
    • ADA (Americans with Disabilities Act), Public Law 101-336. 7/26/90 is very often cited by other sources for good design of stairs and ramps etc. even where disabled individuals are not the design target.
    • ANSI A117.4 Accessible and Usable buildings and Facilities (earlier version was incorporated into the ADA)
    • ASTM F 1637, Standard Practice for Safe Walking Surfaces, (Similar to the above standards)
  • America's Favorite Homes, mail-order catalogues as a guide to popular early 20th-century houses, Robert Schweitzer, Michael W.R. Davis, 1990, Wayne State University Press ISBN 0814320066 (may be available from Wayne State University Press)
  • American Plywood Association, APA, "Portland Manufacturing Company, No. 1, a series of monographs on the history of plywood manufacturing",Plywood Pioneers Association, 31 March, 1967, www.apawood.org
  • Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
  • Asbestos: How to find and recognize asbestos in buildings - visual inspection methods, list of common asbestos-containing materials
  • Asbestos HVAC Ducts and Flues field identification photos and guide
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print).
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • Brick nogging used as soundproofing is mentioned in this article on Popular Forest
  • Brick Nogging, Historical Investigation and Contemporary Repair, Construction Specifier, April 2006. Historical use of brick in timber-framed buildings, drawing on the investigations of the Kent Tavern in Calais, VT. "Brick nogging is a European method of construction which was brought to the new world in the early-nineteenth century. It was a common construction method that employed masonry as infill between the vertical uprights of wood framing." -- quoting the web article review.
  • Photo of very rough in-wall brick nogging at an architects website
  • Building Research Council, BRC, nee Small Homes Council, SHC, School of Architecture, University of Illinois at Urbana-Champaign, brc.arch.uiuc.edu. "The Small Homes Council (our original name) was organized in 1944 during the war at the request of the President of the University of Illinois to consider the role of the university in meeting the demand for housing in the United States. Soldiers would be coming home after the war and would be needing good low-cost housing. ...  In 1993, the Council became part of the School of Architecture, and since then has been known as the School of Architecture-Building Research Council. ... The Council's researchers answered many critical questions that would affect the quality of the nation's housing stock.
    • How could homes be designed and built more efficiently?
    • What kinds of construction and production techniques worked well and which did not?
    • How did people use different kinds of spaces in their homes?
    • What roles did community planning, zoning, and interior design play in how neighborhoods worked
  • The Circular Staircase, Mary Roberts Rinehart
  • Construction Drawings and Details, Rosemary Kilmer
  • "An Example of Colonial Paneling", Norman Morrison Isham, The Metropolitan Museum of Art Bulletin, Vol. 6, No. 5 (May, 1911), pp. 112-116, available by JSTOR.
  • Dust from the World Trade Center collapse following the 9/11/01 attack: the lower floors of this building contained spray-on fire-proofing asbestos materials.
  • "Energy Savers: Whole-House Supply Ventilation Systems [copy on file as /interiors/Energy_Savers_Whole-House_Supply_Vent.pdf ] - ", U.S. Department of Energy energysavers.gov/your_home/insulation_airsealing/index.cfm/mytopic=11880?print
  • "Energy Savers: Whole-House Exhaust Ventilation Systems [copy on file as /interiors/Energy_Savers_Whole-House_Exhaust.pdf ] - ", U.S. Department of Energy energysavers.gov/your_home/insulation_airsealing/index.cfm/mytopic=11870
  • "Energy Savers: Ventilation [copy on file as /interiors/Energy_Savers_Ventilation.pdf ] - ", U.S. Department of Energy
  • "Energy Savers: Natural Ventilation [copy on file as /interiors/Energy_Savers_Natural_Ventilation.pdf ] - ", U.S. Department of Energy
  • "Energy Savers: Energy Recovery Ventilation Systems [copy on file as /interiors/Energy_Savers_Energy_Recovery_Venting.pdf ] - ", U.S. Department of Energy energysavers.gov/your_home/insulation_airsealing/index.cfm/mytopic=11900
  • "Energy Savers: Detecting Air Leaks [copy on file as /interiors/Energy_Savers_Detect_Air_Leaks.pdf ] - ", U.S. Department of Energy
  • "Energy Savers: Air Sealing [copy on file as /interiors/Energy_Savers_Air_Sealing_1.pdf ] - ", U.S. Department of Energy
  • Falls and Related Injuries: Slips, Trips, Missteps, and Their Consequences, Lawyers & Judges Publishing, (June 2002), ISBN-10: 0913875430 ISBN-13: 978-0913875438
    "Falls in the home and public places are the second leading cause of unintentional injury deaths in the United States, but are overlooked in most literature. This book is unique in that it is entirely devoted to falls. Of use to primary care physicians, nurses, insurance adjusters, architects, writers of building codes, attorneys, or anyone who cares for the elderly, this book will tell you how, why, and when people will likely fall, what most likely will be injured, and how such injuries come about. "
  • Fiberglass: Indoor Air Quality Investigations: Health Concerns About Airborne Fiberglass: Fiberglass in Indoor Air from HVAC ducts, and Building Insulation
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?
  • Lighting, proper use of: proper aiming of a good flashlight can disclose hard to see but toxic light or white mold colonies on walls.
  • Nogging: See this photo of exposed bricks on a building exterior on a building exterior in Canada. [Thanks to Carson Dunlop, Toronto - see References below].
  • Pergo AB, division of Perstorp AB, is a Swedish manufacturer or modern laminate flooring products. Information about the U.S. company can be found at http://www.pergo.com where we obtained historical data used in our discussion of the age of flooring materials in buildings.
  • Piquet Wall Construction: See this photo of piquet wall construction - involving timber-framed wall construction with long top girts, diagonal timber bracing, and small diameter logs placed vertically along with concrete chinking to fill in the wall plane.
  • Plank House Construction: weblog from plankhouse.wordpress.com/2009/01/25/plank-house-construction/ and where plank houses were built by native Americans, see
    Large 1:6 Scale Plank House Construction / P8094228, Photographer: Mike Meuser
    06/12/2007 documented at yurokplankhouse.com where scale model Museum quality Yurok Plank Houses are being sold to raise money for the Blue Creek - Ah Pah Traditional Yurok Village project.
  • Re-Bath, tub lining products is a bath tub relining manufacturer and distributor located in Tempe, Arizona - see rebath.com
  • Rubblestone Wall Filler: See this Lartigue House using exterior-exposed rubblestone filler between vertical timbers of a post and beam-framed Canadian building.
  • Slips, Trips, Missteps and Their Consequences, Second Edition, Gary M. Bakken, H. Harvey Cohen,A. S. Hyde, Jon R. Abele, ISBN-13: 978-1-933264-01-1 or ISBN 10: 1-933264-01-2, available from the publisher, Lawyers ^ Judges Publishing Company,Inc., www.lawyersandjudges.com sales@lawyersandjudges.com and also from the InspectAPedia Bookstore (Amazon.com)
  • The Stairway Manufacturers' Association, (877) 500-5759, provides a pictorial guide to the stair and railing portion of the International Residential Code. [copy on file as http://www.stairways.org/pdf/2006%20Stair%20IRC%20SCREEN.pdf ] -
  • What Mold and Allergens Look Like: mold identification photos to help identify mold - choosing what to sample in buildings
  • How to Clean Moldy Wood Framing & Sheathing How to clean/seal mold from/on exposed lumber or plywood subfloor or roof sheathing indoors - some suggestions based on our field and laboratory research
  • Lighting, proper use of: proper aiming of a good flashlight can disclose hard to see but toxic light or white mold colonies on walls.
  • Manufactured & Modular Homes: Modular Building Systems Association, MBSA, modularhousing.com, is a trade association promoting and providing links to contact modular builders in North America. Also see the Manufactured Home Owners Association, MHOAA, at www.mhoaa.us. The Manufactured Home Owners Association of America is a National Organization dedicated to the protection of the rights of all people living in Manufactured Housing in the United States.
  • Mold spores in the Home - a Photo ID Library for detection and identification of mold allergens.
  • How to Find and Test For Mold in buildings A "how to" photo and text primer on finding and choosing the right spots to test for mold in buildings
  • Stuff that is not mold but is often mistaken for it - things you may not want to test. Also, not all "black mold" is toxic - here are examples of harmless black mold.
  • Simple Adhesive Tape Sampling of Moldy Surfaces - how to send a mold sample to our lab
  • Mold Sampling Methods in the Indoor Environment - In-depth article: detailed critique of popular mold testing methods - Is your mold test kit worth the bother?
  • Mold-Resistant Building Practices, advice from an expert on how to prevent mold after a building flood and how to prevent mold growth in buildings by selection of building materials and by anti-mold construction details.
  • Slips, Trips, Missteps and Their Consequences, Gary M. Bakken, H. Harvey Cohen, Jon R. Abele, Alvin S. Hyde, Cindy A. LaRue, Lawyers and Judges Publishing; ISBN-10: 1933264012 ISBN-13: 978-1933264011
  • Slips, Trips, Missteps and Their Consequences, Second Edition, Gary M. Bakken, H. Harvey Cohen,A. S. Hyde, Jon R. Abele, ISBN-13: 978-1-933264-01-1 or ISBN 10: 1-933264-01-2, available from the publisher, Lawyers & Judges Publishing Company,Inc., www.lawyersandjudges.com sales@lawyersandjudges.com and also from the InspectAPedia Bookstore (Amazon.com)
  • Steps and Stairways, Cleo Baldon & Ib Melchior, Rizzoli, 1989.
  • The Staircase, Ann Rinaldi
  • Common Sense Stairbuilding and Handrailing, Fred T. Hodgson
  • The Art of Staircases, Pilar Chueca
  • Building Stairs, by pros for pros, Andy Engel
  • A Simplified Guide to Custom Stairbuilding, George R. Christina
  • Basic Stairbuilding, Scott Schuttner
  • The Staircase (two volumes), John Templar, Cambridge: the MIT Press, 1992
  • The Staircase: History and Theories, John Templar, MIT Press 1995
  • Steps and Stairways, Cleo Baldon & Ib Melchior, Rizzoli, 1989.
  • "The Dimensions of Stairs", J. M. Fitch et al., Scientific American, October 1974.
  • "The Elimination of Unsafe Guardrails, a Progress Report," Elliott O. Stephenson, Building Standards, March-April 1993
  • "Are Functional Handrails Within Our Grasp" Jake Pauls, Building Standards, January-February 1991
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • Weaver: Beaver Board and Upson Board: Beaver Board and Upson Board: History and Conservation of Early Wallboard, Shelby Weaver, APT Bulletin, Vol. 28, No. 2/3 (1997), pp. 71-78, Association for Preservation Technology International (APT), available online at JSTOR.
  • What Style Is It?: A Guide to American Architecture, Rev., John C. Poppeliers, S. Allen Chambers, Wiley; Rev Sub edition (October 6, 2003), ISBN-10: 0471250368, ISBN-13: 978-0471250364
  • ...

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com