InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Indoor
Environment
| Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


EXTERIORS of BUILDINGS
AGE of a BUILDING - how to determine
ALGAE, FUNGUS, LICHENS, MOSS
ATTIC CONDENSATION
BASEMENT WATERPROOFING
BOOKSTORE - EXTERIORS
CHIMNEY INSPECTION DIAGNOSIS REPAIR
DECK & PORCH CONSTRUCTION
DECK COLLAPSE Case Study
DECK FLASHING LEAKS, ROT Case Study
EARTHQUAKE DAMAGED FOUNDATIONS
ENERGY SAVINGS in BUILDINGS
ENVIRO HAZARDS
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
HEAT TAPES & CABLES on Roofs for Ice Dams
HOUSEWRAP AIR & VAPOR BARRIERS
LOG HOME GUIDE
LIGHTNING PROTECTION
MOLD DETECTION & INSPECTION GUIDE
ODORS & SMELLS DIAGNOSIS & CURE
PAINT & STAIN GUIDE, EXTERIOR
PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PORCHES & Sunrooms
ROOFING DIAGNOSIS INSPECTION & REPAIR
SEPTIC SYSTEMS
SHEATHING, Gypsum board
SHEATHING Homasote & Other Board
SHEATHING, OSB
SHEATHING, Plywood
SHEATHING, FOIL FACED - VENTS
SIDING, ASBESTOS CEMENT SHINGLES
SIDING EIFS STUCCO
SIDING HARDBOARD
  Abatibi Siding Claims
  Boise Cascade Siding Claims
  JamesHardie HardiPlank Siding
  Masonite Siding Claims
SIDING VINYL
SIDING WOOD
STAIN DIAGNOSIS on Building Exteriors
STAIN DIAGNOSIS on Indoor Surfaces
STAIRS, RAILINGS, LANDINGS, RAMPS
STUCCO OVER FOAM INSULATION
TERMITES, ROT
THERMAL EXPANSION of MATERIALS
THERMAL MASS in BUILDINGS
THERMAL MASS in UPSTAIRS
VAPOR BARRIERS & AIR SEALING at BAND JOISTS
VAPOR BARRIERS & CONDENSATION in BUILDINGS
VAPOR BARRIERS & HOUSEWRAP
VAPOR CONDENSATION & BUILDING SHEATHING
VENTILATION in BUILDINGS
WATER ENTRY in BUILDINGS
  ATTIC LEAKS Moisture or Mold
  BASEMENT HEAT LOSS
  BASEMENT LEAKS Moisture or Mold
  BASEMENT WATERPROOFING
  Chimney Leaks
  CRAWL SPACE Dryout Procedures
  DEW POINT CALCULATION for WALLS
  DEW POINT TABLE - CONDENSATION POINT GUIDE
  EFFLORESCENCE, Salts & White / Brown Deposits
  FLOOD Damage Assessment & Repairs
  FLOOD DAMAGED FOUNDATIONS
  FLOOD VENTS
  FLOODS IN BUILDINGS-priorities
  FOUNDATION WATERPROOFING
  HUMIDITY CONTROL & TARGETS INDOORS
  HOUSEWRAP AIR & VAPOR BARRIERS
  LOG HOME Leak Diagnosis & Cure
  LOG HOME Condensation &Moisture
  MOISTURE CALCULATIONS
  MOISTURE PROBLEMS: CAUSE & CURE
  MOLD in BUILDINGS
  SEWAGE CONTAMINATION
  SUMP PUMPS GUIDE
  WATER ENTRY in BUILDINGS
WIND TURBINES
WINDOWS & DOORS
  SKYLIGHT LEAK DIAGNOSIS & REPAIR
  SITE BUILT DOUBLE GLAZED WINDOWS
  SLOPED GLAZING DETAILS
  VERTICAL GLAZING DETAILS
  WINDOW / DOOR ENERGY EFFICIENT, DOE
  WINDOW LEAKS INTO BASEMENT
WINTERIZE A BUILDING
MOLD DETECTION & INSPECTION GUIDE
MVOCs & MOLDY MUSTY ODORS
ODORS & SMELLS DIAGNOSIS & CURE
ROOFING INSPECTION & REPAIR

More Information

Mobile Phone/PDA website viewMobile View
InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Photograph of badly deteriorated hardboard siding

Boise Cascade Hardboard Siding Failures Information
InspectAPedia®  -    

  • Boise Cascade siding damage explanation, inspection, & failure diagnosis guide
  • Boise Cascade Siding Failures & class action lawsuit contact information.
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

Boise Cascade™ hardboard siding is similar to products sold by Masonite Corp., Abatibi-Price, and Georgia Pacific Corp, both of which experience failures of delamination, swelling, softening, and general deterioration when exposed to water and weather.

Common Causes of Boise Cascade™ and other Hardboard Building Siding Failures

Our own field observations show that the siding material deteriorates fastest and most severely where:

  • The Boise Cascade™ hardboard siding (and similar products) has not been kept perfectly sealed and coated against water intrusion
  • The Boise Cascade™ hardboard siding has been damaged by cuts, nicks, or by counter-sunk siding nails that penetrated its top skin and were not kept perfectly sealed
  • The Boise Cascade™ hardboard siding has been exposed to high amounts of rain (weather side of buildings), or where it is exposed to roof spillage splash-up against siding, for example where building gutters and leaders are not installed or are not properly maintained
  • The end butt-joints of the Boise Cascade™ siding were not kept sealed where exposed to weather
  • Water penetrates the Boise Cascade™ siding and building wall at poorly-flashed or poorly-installed windows, doors, or other wall penetrations

We have photographs and material samples on-hand and solicit field reports and photographs to add to Abatibi siding identification, maintenance, repair, replacement, and class action information at this website.

If you have additional product failure examples you are welcome to contact the author to provide additional field photos or information that may assist others in identifying and repairing siding failures.

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

SIDING, ASBESTOS CEMENT SHINGLES
SIDING EIFS STUCCO
SIDING HARDBOARD
  Abatibi Siding Claims
  Boise Cascade Siding Claims
  JamesHardie HardiPlank Siding
SIDING VINYL

More Information on Building Diagnostic Inspections and Repairs

    ...
InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

11/28/2009 - 08/14/1995 - InspectAPedia.comexterior/boise.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark