InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Indoor
Environment
| Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


THE FPE Stab-Lok WEBSITE
SUMMARY OF the FPE Stab-Lok PROBLEM
FPE HAZARD ARTICLES, STUDIES
FPE Stab-Lok TECHNICAL REPORT
HOW TO IDENTIFY FPE & FP
REPORTS OF FPE FAILURES
HOW TO REPORT FPE INCIDENTS
FPE REPAIR ELECTRICIANS
FPE REPLACEMENT BREAKERS
REPLACEMENT PANELS
  OPTION #1 RETROFIT KIT
  OPTION #2 REPLACEMENT
  OPTION #1 vs OPTION #2
REPLACEMENT PANEL COSTS
CAN'T AFFORD A NEW ELECTRIC PANEL?
CANADIAN VERSIONS of FPE Stab-Lok
FPE Stab-lok: FIRES WAITING TO HAPPEN
ADVICE TO HOME BUYERS w/ FPE PANELS
HOME INSPECTION LANGUAGE for FPE Stab-Lok

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Photograph of  Eaton Cutler Hammer Electric Retrofit Kit for Electrical Panel ReplacementCost to Replace an Electrical Panel
InspectAPedia®  -    

  • What are the usual costs to replace an electrical Panel, FPE Stab-Lok, Zinsco, or Other Brand?
  • How to electrical panel replacement costs vary across the United States?
  • What factors affect the typical cost to replace an FPE Stab-Lok, Zinsco, or other Electrical Panel?
  • Eaton Cutler Hammer replacement panel choices for Federal Pacific Electric Stab-Lok equipment
  • Sources for Replacement FPE Stab-Lok electrical panels
  • Should you Ever Use Replacement FPE Stab- Lok circuit breakers?

We recommend that residential FPE Stab-Lok electrical panels be replaced entirely or the entire panel bus assembly be replaced entirely, regardless of model number or year of manufacture. We recommend against replacing individual FPE Stab-lok circuit breakers. We do not sell circuit breakers nor any other products. Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

This document discusses the typical costs to replace an electrical panel. This is a chapter of our longer articles which describes how to replace Federal Pacific Stab-Lok Electric Panels or Zinsco / Zinsco-Sylvania Electric Panels in buildings. © Copyright 2009 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Electrical Panel REPLACEMENT COST Typical cost of the traditional FPE Electrical Panel Replacement

Quotes From Electrical Contractors on Electric Panel Replacement

Quotes from electrical contractors on panel replacement by installing a complete, new, electrical panel, can be expected to vary by area of the country, hardware needed, replacement panel size in ampacity and number of circuits, accessibility to perform the work, and other factors that affect labor or materials. That said, we've heard panel replacement costs ranging from $1,200. to $4,000 (April 2007, Northwestern United States). If you are surprised by the quotation you receive from your electrician, ask for the supporting details of the bid or ask for a bid from a competitor too. Shop expertise and workmanship not just price.

Northeastern U.S.: Typically the installation of a new 100-Amp electrical pane in the Northeastern U.S. is around $1,200 to $1,500. (June 2006, Northeastern U.S.). This figure does not include the additional cost for a service panel (150A or 200A), extra labor, or materials for demolition and repair of a wall needed to address an electric panel which is already installed.

Southwestern U.S.: (Such as Dallas Fort Worth) Typically the installation of a new 100-Amp electrical pane in the Southwestern U.S. is around $1,200 to $2,100. (February 2008 Dallas Electrical Costs). A 150A or 200A electrical panel may cost up to $2400. from some installers.

Additional costs for replacement electrical panel installations: may be expected where there is difficulty of access, where demolition and wall repair are needed, where the electrical service is being upgraded to a larger ampacity than that of the panel being replaced, or where there are other special requirements. Typical factors affecting the cost of electrical repair and retrofit work are discussed in more detail just below.

The "Short Wire" problem and the Eaton Renovation Load Center: Electrical panel, FPE, Zinsco, or any other brand can be extra difficult when replacing the entire panel if only short lengths of wire are available in the old electrical box. Especially if the new electric panel is physically larger than the one being replaced, the original wires may not reach the circuit breakers in the new panel.

A product which might help when the entire loadcenter (what normal people call the "electric panel") is going to be replaced. is E-CH's "Renovation Loadcenters". The unique feature is that UL listed terminal blocks are provided in the enclosure as a means to terminate existing wires too short to reach the new panel's branch circuit breakers or neutral bus. A new wire can then be wired from the terminal block to the breaker or neutral.

This is a safer method than the twist-on connectors commonly used, or a separate terminal box, which takes up extra space. I do not discuss this approach further here but more information is available from Eaton Corp., Cutler Hammer Products or through your electrician and electrical supplier.

"RETROFIT COST - Cost of Replacing an FPE Panel using the E-CH Adjustable Retrofit Kit" discusses the costs of FPE panel replacement using Cutler Hammer's retrofit electrical panel kit. This money-saving option is sometimes suitable, depending on the physical dimensions of the original electrical panel and the ampacity of the new service to be installed.

Factors Affecting the Cost of an Electrical Panel Replacement

  • Area of the country: prevailing wages and other costs for electricians vary by area of the country as well as city, town, or rural rates.
  • Electrical Work Permits and Electrician Licensing Fees required vary by municipality as do the fees that must be paid for those permissions to install an new electrical panel.
  • Amount of labor required to remove the old panel: this may vary widely depending on where and how the old electrical panel was installed, the amount of demolition, the necessity to perform cosmetic repairs to a surrounding wall or other surface, and even the working space to access the old panel.
  • Condition of the existing electrical wiring or its insulation: may affect panel replacement cost. Copper in electrical wiring does not deteriorate with mere age (contrary to what a New Paltz NY contractor told one of our clients). But the wire insulation may be damaged and unsafe from age, or from overheating. (Overheating a wire, unlike mere age, can also damage the copper wire itself.) Damaged electrical wires may have to be replaced. Replacement does not necessarily mean that the entire circuit needs to be replaced. Often overheating occurs locally, such as close to a connection or in a light fixture. The electrician may be able to cut back the damaged wiring, install a junction box, and extend the old circuit to the new electrical panel.
  • Obsolete electrical wiring such as knob and tube wiring does not necessarily have to be replaced (by code) but may be damaged, modified, or otherwise unsafe. Since a traditional knob and tube electrical circuit lacks a ground wire, these circuits should be upgraded to new wire whenever possible.
  • Physical size of the old electrical panel may be too small to preclude its re-use with a panel retrofit kit, so the entire box needs to be replaced.
  • Short electrical wires in the old panel may make it difficult or impossible to connect the existing wires to breakers in a new, physically larger electrical panel. Extensions, junction boxes, or a retrofit panel kit may be needed. We discussed this concern just above
  • Other new electrical work: may end up being part of your project. Since it's going to cost just to have your electrician walk in the door to do any job, it is often more economical to batch together multiple electrical tasks into one larger project. Discuss with your electrician other electrical improvements such as adding circuits, installing grounded electrical receptacles, adding a switch you've always wanted, and other improvements that may be less costly when added to the electrical panel replacement project.

Share this Article      

...

Technical Reviewers & References

  • Daniel Friedman - principal author/editor of the InspectAPedia® Website
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

THE FPE Stab-Lok WEBSITE
SUMMARY OF the FPE Stab-Lok PROBLEM
FPE HAZARD ARTICLES, STUDIES
FPE Stab-Lok TECHNICAL REPORT
HOW TO IDENTIFY FPE & FP
REPORTS OF FPE FAILURES
HOW TO REPORT FPE INCIDENTS
FPE REPAIR ELECTRICIANS
FPE REPLACEMENT BREAKERS
FPE REPLACEMENT PANELS
FPE REPLACEMENT PANEL COSTS
CAN'T AFFORD A NEW ELECTRIC PANEL?
CANADIAN VERSIONS of FPE Stab-Lok
FPE Stab-lok: FIRES WAITING TO HAPPEN
ADVICE TO HOME BUYERS w/ FPE PANELS
HOME INSPECTION LANGUAGE for FPE Stab-Lok

  • Thanks to Lance Caddell, Master Electrician, Caddell Electric, LLC. for comments and corrections 2/16/08

Information Source Citations & Feedback Request

Information Source Notice: portions of the text of this document are from email exchanged between the web author and the Eaton Corp., Cutler Hammer Products Lead Design Engineer and Eaton Product Manager involved with the products discussed in this document. The illustration at page top is from the Eaton Electrical PDF which describes their product line. The author has no financial nor any other connection with Eaton Corp., Cutler Hammer Products, nor any other company whose products are discussed at this website. Corrections of errors or omissions, product user feedback, or other critique are invited. Our editorial policies are at Accuracy & Bias Pledge

We solicit photos and description of field experience from installing electricians and from consumers. Contact Us to report field experience with this equipment.

THE FPE Stab-Lok WEBSITE

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
InspectAPedia ® Home & Site Map
Contact Us

More Information on Building Diagnostic Inspections and Repairs

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

04/15/2009 - 06/03/06InspectAPedia.com/fpe/ElectricPanelReplacementCost.htm - © 2009 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark