InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile Phone/PDA website viewMobile View
BUILDING SAFETY HAZARDS GUIDE
ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
AFCIs ARC FAULT CIRCUIT INTERRUPTERS
ALUMINUM SECs & WIRING
ALUMINUM WIRING HAZARDS
AMPS & VOLTS DETERMINATION
AMPACITY - the LIMITING FACTOR
APPLIANCE EFFICIENCY RATINGS
BACKUP ELECTRICAL GENERATORS

Cadet & Encore Heater Recall
CIRCUIT BREAKER FAILURE
CIRCUIT BREAKER SIZE for A/C or HEAT PUMP
CIRCUIT BREAKER SIZE for A/C or HEAT PUMP
Classified CIRCUIT BREAKER WARNING
CUTLER HAMMER PANEL FIRE
CONDUIT, ELECTRICAL
CORROSION in ELECTRICAL PANELS
CORROSION & MOISTURE SOURCES in PANELS

DEFINITIONS of ELECTRICAL TERMS

DIRECTORY OF ELECTRICIANS
  DIRECTORY OF ELECTRICIANS - Aluminum Wiring
  DIRECTORY OF ELECTRICIANS - FPE Zinsco

ELECTRIC HEAT
ELECTRIC METERS & METER BASES
ELECTRIC MOTOR DIAGNOSTIC GUIDE
ELECTRIC MOTOR OVERLOAD RESET SWITCH
ELECTRIC PANEL AMPACITY
ELECTRIC PANEL INSPECTION
ELECTRIC PANEL MOISTURE
Electric Power Frequency Table
ELECTRICAL BASICS

EMF RF FIELD & FREQUENCY DEFINITIONS

ENERGY SAVINGS in buildings

ELECTRICAL GENERATORS
ELECTRICAL GROUND SYSTEM INSPECTION

FEDERAL PACIFIC FPE HAZARDS
SUMMARY OF the FPE Stab-Lok PROBLEM

FPE HAZARD ARTICLES, STUDIES
  Summary of the FPE Stab-Lok Hazard
  FPE Fraud - Press Release
  FPE Fraud Stab-Lok SEC report
  FPE Exxon Scandal Article
  How to Repair FPE Stab-Lok
  FPE- Fires Waiting to Happen, Debate Waiting to End
  FPE Technical Report - Independent Research 2007
  FPE Technical Report - Independent Research 2011
  New Jersey FPE Class Action 2005
  FPE St Louis Seminar 2004
  Federal Pioneer Recall 1997
  EXXON Buys a Scandal 1980
  FPE HISTORIC DATES 1950-Present
  FPE Pre-1970 STAB-LOKS OK?

FEDERAL PIONEER in CANADA
  What Are Federal Pioneer Panel Concerns?
  Federal Pioneer Warranty Alert
  Federal Pioneer Electrical Circuit Breaker Recall
  Field Reports of Federal Pioneer Problems
  Other Federal Pioneer Concerns
  Are Recent Federal Pioneer Stab-Loks Safe?

FPE Stab-Lok TECHNICAL REPORT
  FPE Stab-Lok Circuit Breaker Test Results
  CPSC Tests
  FPE Test Results
  Southwest Research Incorporated
  Underwriters Laboratories Inc.
  Recent Testing of Field Samples
  FPE Stab-Lok Combination Breaker/GFI
  Non-FPE Stab-Lok Breakers
  FPE Main Breakers
  FPE Stab-Lok Panels
  FPE Stab-Lok Panels with "Rule of Six" Configuration
  Hazardous Failure - an Example
  History of the FPE Problem
  Should FPE Panels be Replaced?
FPE Stab-Lok TECHNICAL REPORT-2004

FPE Stab-Lok Panel Test Report
  FPE Panel Test Performed
  FPE Panel Test Results
  Photos of FPE Stab-Lok Panel

HOW TO IDENTIFY FPE & FP
  FPE STAB-LOK PANEL COVERS
  FEDERAL NOARK PANELS
  FEDERAL ELECTRIC PANELS
  FEDERAL PIONEER PANELS
  FPE PANEL DOOR LABELS
  FPE TOGGLE SWITCH
  FPE BREAKER ID PHOTOS
  FPE BREAKER LABELS
  HOW TO ID FPE IF NO LABELS
  FPE PANEL BUS DESIGNS
  FPE PANEL AGE MATTERS?
  OTHER FPE DEFECTS

REPORTS OF FPE FAILURES
  FPE FIRE & FAILURE PHOTOS
  FPE FAILURE FIELD REPORTS
HOW TO REPORT FPE INCIDENTS

FPE REPAIR ELECTRICIANS

FPE REPLACEMENT BREAKERS
FPE REPLACEMENT PANELS
FPE REPLACEMENT PANEL COSTS
  CAN'T AFFORD A NEW ELECTRIC PANEL?

FPE SUB PANELS, RISK ASSESSMENT

FIRES WAITING TO HAPPEN
  How Many Stab-Loks
  Stab-Lok Failure Rate
  Proper Repair
  Proving the Hazard
  Multiwire Circuits
  Single Pole Breakers
  Latent Safety Hazard
  Failure Reports
  Technical Reports

FPE HISTORY
HOME BUYERS w/ FPE PANELS, ADVICE
HOME INSPECTION LANGUAGE for FPE Stab-Lok
CPSC Closes FPE Investigation, Revised
CPSC Calibration & Condition Tests, 1982
CPSC Investigation FPE Breakers, 1983
IAEI LETTER

FPE Stab-Lok Hazard Summary Page for Public Use

GENERATORS, ELECTRICAL
GFCI PROTECTION,Testing GFCIs AFCIs

HEATING COST FUEL & BTU Cost Table
HEAT, ELECTRIC
HEAT TAPE USAGE GUIDE
Hertz - Definitions of KHz MHz GHz THz

KNOB & TUBE WIRING

LIGHTING, INTERIOR GUIDE

LIGHTNING PROTECTION SYSTEMS

LOW VOLTAGE BUILDING WIRING

MAIN DISCONNECT
MAIN DISCONNECT AMPACITY
MOISTURE SOURCES in PANELS
MULTI-WIRE CIRCUITS
MURRAY SIEMENS Recall

PHOTOVOLTAIC POWER SYSTEMS
PUSHMATIC - BULLDOG PANELS

REMOTE ELECTRIC POWER, PHOTOVOLTAIC
RUST in ELECTRICAL PANELS

SAFETY FOR ELECTRICAL INSPECTORS

SE CABLE SIZES vs AMPS
SIEMENS MURRAY Recall

SOLAR ENERGY SYSTEMS
SQUARE-D RECALLS

UNDERGROUND SERVICE LATERALS
VOLTAGE MEASUREMENT EQUIPMENT

WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING

ZINSCO / SYLVANIA HAZARDS

More Information

Photograph of an FPE Stab-Lok electrical panel label bottomFederal Pacific Electric (FPE) Panels - CPSC Information
InspectAPedia®  -    

  • The closing statement regarding a CPSC Investigation of FPE Circuit Breakers and more safety advice for FPE Stab-Lok breakers
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

This page contains a closing statement regarding a CPSC Investigation of FPE Circuit Breakers and additional safety information for consumers.

Click your browser's "back" button to return to the previous page or use links at the page bottom.
NOTE: This document has been entered verbatim from the original document. Important safety remarks and independent study reports of FPE hazards and advice about what to do can be found at More Information about FPE below.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

FOR RELEASE: MARCH 3, 1983

U.S. Consumer Product Safety Commission CLOSES INVESTIGATION OF FPE CIRCUIT BREAKERS AND PROVIDES SAFETY INFORMATION FOR CONSUMERS

WASHINGTON, D.C. -- The Consumer Product Safety Commission announced today that it is closing its two year investigation into Federal Pacific Electric Stab-lok type residential circuit breakers. This action was taken because the data currently available to the Commission does not establish that the circuit breakers present a serious risk of injury to consumers.

The Commission investigation into Federal Pacific Electric (FPE) circuit breakers began in June, 1980, when Reliance Electric Co., a subsidiary of Exxon Corporation and the parent to FPE, reported to the Commission that many FPE circuit breakers did not fully comply with Underwriters Laboratories, Inc. (UL) requirements. Commission testing confirmed that these breakers fail under certain UL calibration test requirements. The Commission investigation focused primarily on 2-pole residential circuit breakers manufactured before Reliance acquired FPE in 1979.

To meet UL standards, residential circuit breakers must pass a number of so-called "calibration tests." The purpose of these tests is to determine whether the circuit breakers will hold the current for which they are rated and also automatically open or "trip" (shut off the current) within the specified time limits if over-loading of the circuit breakers causes current levels in excess of the breaker's amperage rating. (Overloading can occur because a consumer plugs too many products into a circuit or due to the failure of a product or component connected to that circuit.) While the Commission is concerned about the failure of these FPE breakers to meet UL calibration requirements, the Commission is unable at this time to link these failures to the development of a hazardous situation.

According to Reliance, failure of these FPE breakers to comply with certain UL calibration requirements do not create a hazard in the household environment. It is Reliance's position that FPE breakers will trip reliably at most overload levels unless the breakers have been operated in a repetitive, abusive manner that should not occur during residential use. Reliance maintains that, at those few overload levels where FPE breakers may fail to trip under realistic use conditions, currents will be too low to generate hazardous temperatures in household wiring. Reliance believes that its position in this regard is supported by test data that is provided to the Commission.

The Commission staff believes that it currently has insufficient data to accept or refute Reliance's position.

The Commission staff estimates that it would cost several million dollars to gather the data necessary to assess fully whether those circuit breakers which are installed in homes but which may fail UL calibration tests present a risk to the public. Based on the Commission's limited budget ($34 million for fiscal year 1983), the known hazards the Commission has identified and must address (involving products of other manufacturers) and the uncertainty of the results of such a costly investigation, the Commission has decided not to commit further resources to its investigation of FPE's circuit breakers. However, despite its decision to close this particular investigation, the Commission will continue its investigation of circuit breakers generally. The Commission can reopen its investigation of FPE breakers if further information warrants.

The Commission advises consumers to take certain safety precautions with all circuit breakers and fuses. Consumers should:

-Know your electrical circuit. Know which outlets and products are connected to each circuit.

-Never overload any electrical circuit by connecting too many products to the circuit. Be particularly careful not to connect several products that demand high current (such as heating appliances) to a low amperage circuit.

-Comply with local building codes in wiring or adding electrical circuits. Make sure the wiring and devices used in the circuit are connected to a circuit breaker or fuse of the

-Immediately disconnect any electrical product if problems develop. Have the product examined by a competent repair person.

-Investigate to determine why a fuse blows or circuit breaker trips. Do not simply replace the fuse or reset the breaker. If a fuse blows or breaker trips, it is often a warning that the circuit is overloaded. Check the circuit for causes of overloading (for example, too many appliances plugged in, a malfunctioning product, a short circuit). When in doubt, consult a licensed electrician.

Consumers who have questions concerning circuit breakers, or who wish to report information relating to their safety, may call the U.S. Consumer Product Safety Commission's toll-free safety hotline at 800-638-CPSC, teletypewriter for the hearing impaired at 800-638-8270 (Maryland only 800-492-8104).

...

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

FPE Stab-Lok HAZARDS & REPAIRS WEBSITE

  • Note: as we didn't add this reviewers list until 2007, this list of technical reviewers is incomplete; we have received comments and suggestions regarding this topic, edits and remarks included, from engineers and management from the US CPSC, electricians (many listed at our page on field reports of FPE failures), home inspectors, licensed electricians, and electrical engineers, and even a few attorneys and real estate agents, since 1986. Technical review, critique, content suggestions, questions, or clarifications are invited and where a contributor wishes, credit and links will be provided to that source. Contact us to provide feedback.
  • Dr. Jess Aronstein, electrical engineer, Poughkeepsie, NY, forensic engineering services, independent laboratory testing for various agencies protune@aol.com (independent electrical panel testing, including FPE Stab-Lok panels, to April 2010)
  • David Carrier, electrical engineer, 53 Henmond Blvd., Poughkeepsie, NY 12603 845-430-7527 davidwcarrier@earthlink.net (independent electrical panel testing, including FPE Stab-Lok panels, beginning 2010)
  • Alan Carson, Carson Dunlop, Associates, Toronto, Ontario. Mr. Carson is a home inspection professional, educator, researcher, writer, and a principal of Carson Dunlop Associates, a Toronto home inspection and education firm. Mr. Carson is a past president of ASHI, the American Society of Home Inspectors
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. (727) 595-4211 mark@BestTampaInspector.com 11/06
  • Carl Grasso, Esq., Herzfeld & Rubin, New York, NY. Mr. Grasso is an attorney who managed a plaintiff's class action litigation against Federal Pacific Electric in New Jersey.
  • William King, US CPSC Director of Electrical Engineering (Ret).
  • Licensed Electricians: FPE Fire and Failure Reports includes electricians who have provided cases and photographs of field failures of FPE equipment at this website.
  • Homeowners, Home Inspectors, Electricians: Federal Pacific Electric (FPE) Panel Fires and other Failures includes anecdotal field reports provided by a range of contributors including electricians (and some home owners or home inspectors) who have provided cases and photographs of field failures of FPE equipment at this website.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Aluminum Wiring Information Website Aluminum Electrical Wiring Hazards and Repairs: in-depth authoritative info, photos, documents including selection of proper vs. ineffective repair methods. E.g.: Ideal 65 "Twister" purple connector fails in field and lab testing with aluminum wire.
  • Ampacity of an Electrical Service: How to determine the electrical service size or ampacity entering a building
  • Circuit Breaker, a bad one fails to trip failure at aluminum bus-to-circuit breaker connection - field report and photographs
  • Electrical System & Wiring Hazard Inspection, Detection, Cause, Remedy, Prevention - Main Electrical Page
  • Electrical Panels, How to Inspect in buildings, safety for electrical inspectors, electrical panel, fusing, wiring defects, defective products. Inspection Class Presentation
  • The Federal Pacific Stab-Lok Electric Panel Hazard Website Safety Information for Consumers.
  • 2007 FPE Stab-Lok TECHNICAL REPORT - an updated test report of independent testing (a large 1.2MB PDF file) using a larger pool of FPE Stab-Lok circuit breakers than the older CPSC and Wright Malta tests found significantly higher failure rates of FPE Stab-Lok circuit breakers, including a look at critical safety failures (breaker failed to trip at 200% of rated current or jammed) which found up to 80% failure rate for FPE Stab-Lok GFCI circuit breakers (n=4), 12% failure rate for double pole FPE Stab-Lok circuit breakers (n=120), and a 1% failure rate for FPE Stab-Lok single pole circuit breakers (n=345).
  • FPE FIRES: Failures continue: FPE breaker fails, results in fires: field reports
  • Federal Pacific Electric Fires Waiting to Happen, Debate Waiting to Be Ended, detailed article
  • Home Inspection Reporting Language and discussion for FPE panels
  • Home Inspection Reporting Language and discussion for FPE panels
  • How to Identify FPE Federal Pacific Stab-Lok Electric Panels - is yours one of these? ALSO: A History of the FPE Stab-Lok Issue.
  • Federal Pacific Electric Panels: Fires Waiting to Happen, Debate Waiting to Be Ended
  • How to Identify Federal Pacific Electric Panels Stab Lok Breakers & History of the Federal Pacific Electric Stab Lok Hazard
  • Replacement Circuit Breakers for FPE Stab-Lok Electric Panels? are not recommended
  • Replacement Panels for FPE Stab-Lok load centers - options include conventional complete panel replacement and a less costly replacement of the panel interior load center/bus assembly
  • Schneider Canada Federal Pioneer circuit breaker recall
  • 1983 CPSC Investigation of FPE Circuit Breakers Safety Information for Consumers
  • 1982 Reliance Electric Co. SEC Quarterly Report: Note C. reports litigation between Reliance and UV Liquidating Trust and contends that "... improper and deceptive practices were employed for many years to secure UL listings for Federal Pacific's circuit protective products..."
  • 1980 Reliance Electric Co. Press Release: improper practices used to obtain UL Listing for most of FPE's circuit breakers and notes testing which indicates "possible defects." 1980, Reliance Electric Co.
  • 1980 FPE - Exxon Buys A Scandal Along With A Company improper practices used to obtain UL Listing for most of FPE's circuit breakers and notes testing which indicates "possible defects." 1980, Reliance Electric Co.

  • Safety Hazards and Safe Inspection Procedures for Electrical and Home Inspectors at Residential Electric Panels
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com