InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile viewMobile View
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

Aerobiology Associations

AIR CLEANER PURIFIER TYPES
AIR FILTER EFFECTIVENESS
AIR FILTERS, FIBERGLASS PARTICLES
AIR FILTERS for HVAC SYSTEMS
AIR FILTERS, OPTIMUM INDOOR
AIR FILTERING STRATEGIES
AIR FILTERING CONTINUOUS FAN OPERATION
AIR HANDLER / BLOWER UNITS
AIR LEAK DETECTION TOOLS

AIR POLLUTANTS, COMMON INDOOR
Air Quality Improvement Strategies
AIR LEAK SEALING PROCEDURE
AIR SEALING STRATEGIES
AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY
AIRBORNE MOLD SPORE COUNT ACCURACY

ALLERGEN TESTS for BUILDINGS
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY

ANIMAL ALLERGENS / PET DANDER
  PERSISTENCE of ALLERGNS
  CAT DANDER in BUILDINGS
  CLEANING SUGGESTIONS
  DRUGS vs CLEANUP
  ALLERGEN DANDER STUDY
  PETS AS FAMILY MEMBERS
  REDUCING PET ALLERGENS
ANIMAL ENTRY POINTS in BUILDINGS
ANIMAL ODORS IN BUILDINGS
  Finding the Source of Animal Odors
  Cleaning Suggestions for Odors / Urine
  Removing Odors at Building Exteriors
  Removing Urine Odors from Clothing

ASBESTOS CLEANUP COMPANIES
ASBESTOS ROOFING / SIDING DUST
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN BUILDINGS
  ASBESTOS AIR DUCTS
  Asbestos Air Duct Vibration Dampers
  ASBESTOS in CARPETING, PADDING
  ASBESTOS CEILING TILES, Asbestos-Containing
  ASBESTOS DUCTS, HVAC
  ASBESTOS DUCT INSULATION, Asbestos Paper
  ASBESTOS DUCTS, Transite Pipe
  ASBESTOS FIREPROOFING SPRAY-On Coatings
  ASBESTOS FLOOR TILE IDENTIFICATION
  ASBESTOS FLOOR TILE Laboratory Procedures
  ASBESTOS FLOOR TILE PHOTO ID GUIDE
  Asbestos Foamed-Over
  ASBESTOS INSULATION
  ASBESTOS PAPER DUCT INSULATION
  ASBESTOS PIPE INSULATION
  ASBESTOS ROOFING, CEMENT & FIBER CEMENT
  ASBESTOS SIDING CEMENT & FIBER CEMENT
  Asbestos in unusual places
  Asphalt-asbestos Paints & sealants
  Carbon Nanotube Materials
  TRANSITE PIPE AIR DUCTS
  Transite Pipe Chimneys & Flues
  Transite Pipe Water Supply Piping
  VERMICULITE INSULATION
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS FLOORING REMOVAL GUIDE
ASBESTOS List of Asbestos-Containing Products
ASBESTOS MATERIAL REGULATIONS
ASBESTOS MATERIAL REGULATIONS Update
ASBESTOS MATERIAL REGULATIONS, OSHA Roofing/Siding
ASBESTOS Photo Guide to Materials / Products
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
ASBESTOS REMOVAL GUIDE, FLOORING
ASBESTOS REMOVAL, Wetting Guidelines
ASBESTOS RISK ASSESSMENT
Asbestos Under the Microscope

ATTORNEYS and EXPERT WITNESSES

Backdrafting Appliances
BASEMENT MOLD
BASKETBALL MOLD SYNDROME - BBMS
BATHROOM MOLD

BIBLIOGAPHY ENVIRONMENTAL HEALTH, MOLD, IAQ
  AIR POLLUTANTS, COMMON INDOOR
  ALLERGEN TESTS for BUILDINGS
  ASBESTOS IDENTIFICATION IN BUILDINGS
  Bacteria, Mold, & Pollen
  Basic Science & Theory Refs.
  BIOLOGICAL POLLUTANTS
  BIOLOGICAL POLLUTANTS in the HOME - EPA
  Bisphenol-A, BPA
  Building Science & Industrial Hygiene, Field & Lab Methods
  Cadmium in the home
  CARBON DIOXIDE - CO2
  CARBON MONOXIDE - CO
  Carbon Nanotube Hazards
  CARPETING & INDOOR AIR QUALITY
  CAT DANDER in BUILDINGS
  Carbon Nanotube Hazards
  COMBUSTION PRODUCTS & IAQ
  CHINESE DRYWALL HAZARDS
  CHEMICAL CONTAMINANTS in WATER
  CHLORINE IN DRINKING WATER
  COMBUSTION GASES & PARTICLE HAZARDS
  Diethylstilbestrol - DES
  EMF ELECTROMAGNETIC FIELDS & HUMAN EXPOSURE
  ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY
  Environmental Hazards, Consumer Publications
  FIBERGLASS HAZARDS
  Fireplace & Woodstove Contaminants
  FORMALDEHYDE HAZARDS
  GASES, EXPOSURE, TESTING
  GAS TOXICITY LEVELS
  HEATING OIL EXPOSURE HAZARDS, LIMITS
  INDOOR AIR QUALITY IMPROVEMENT GUIDE
  INSULATION MOLD
  Lead Exposure Hazards
  LEAD POISONING HAZARDS GUIDE
  Legionella Legionnaires' Disease
  LP & Natural Gas Safety Hazards
  Natural Gas Combustion Products
  Microscopy, Microchemistry
  MILDEW in BUILDINGS ?
  METHANE GAS SOURCES
  MOLD ATLAS & PARTICLES INDEX
  MOLD CLINICAL REFERENCE TEXTS
  MOLD EXPOSURE STANDARDS
  MOLD FAQ's
  MOLD RELATED ILLNESS List
  MSDS Material Safety Data Sheets
  Nanomaterials Hazards
  NOISE / SOUND DIAGNOSIS & CURE
  ODORS GASES SMELLS, DIAGNOSIS & CURE
  OXYGEN - O2
  OZONE HAZARDS
  PAINTS & COATINGS ODORS IN BUILDINGS
  Particles in Indoor Air - Chart
  Pesticide Exposure Hazards
  PLASTIC CONTAINERS, TANKS, TYPES
  PLASTIC HEATER VENT
  PLASTIC ODORS-SCREENS, SIDING
  PLUMBING SYSTEM ODORS
  Pollen Photos
  PVC - VINYL BUILDING PRODUCTS
  Radon Hazards
  SEPTIC SYSTEM ODORS
  SEWAGE BACKUP TEST & CLEANUP
  SULPHUR & SEWER GAS SMELL SOURCES
  Urea Formaldehyde Foam Insulation UFFI
  URETHANE FOAM Deterioration, Outgassing
  VINYL CHLORIDE HEALTH INFO
  Volatile Organic Compounds VOCs
  WATER TESTS, CONTAMINANTS, TREATMENT

BIODETERIORATION AGENT & STAIN CATALOG
BIOGAS PRODUCTION & USE

BIOLOGICAL POLLUTANTS
BIOLOGICAL POLLUTANTS in the HOME - EPA
Bisphenol-A, BPA

BLOWER FAN CONTINUOUS OPERATION
BLOWER FAN OPERATION & TESTING
BLUE vs YELLOW COMBUSTION FLAMES
BLUERAY Recall
BOOKSTORE - ENVIRONMENTAL
BUILDING SAFETY HAZARDS GUIDE
BUY PRODUCTS for MOLD & ALLERGY CONTROL

Cadmium in the home
CARBON DIOXIDE - CO2
  CO2 POISONING SYMPTOMS
  CO2 HEALTH EFFECTS
  CO2 EXPOSURE LIMITS
  TYPICAL CO2 LEVELS
CARBON MONOXIDE - CO
  ALARM CAUSES - CO
  EXPOSURE LIMITS for CO
  INSPECTION for CARBON MONOXIDE
  TESTS for CARBON MONOXIDE
  MEDICAL EFFECTS of CO
  POISONING SYMPTOMS - CO
Carbon Nanotube Hazards

CARPET DUST IDENTIFICATION
CARPET MOLD CONTAMINATION
CARPET PADDING ASBESTOS, MOLD, ODORS
CARPET FUNGICIDAL SPRAY
CARPET STAIN DIAGNOSIS
CARPET & other STAIN TESTS
CARPET TEST GUIDE
CARPETING & INDOOR AIR QUALITY
CARPETING, SELECTION & INSTALLATION

CAT DANDER in buildings
Cell phone Radiation Hazards
CHINESE DRYWALL HAZARDS
CHEMICAL CONTAMINANTS in WATER
CHIMNEY INSPECTION DIAGNOSIS REPAIR

CHLORINE IN DRINKING WATER
CHLORINE in WATER, HOW TO TEST FOR
CHLORINE IN SEPTIC WASTEWATER

COALSTOVE SAFETY
COMBUSTION GASES & PARTICLE HAZARDS
COMBUSTION PRODUCTS & IAQ
CONDENSATION or SWEATING PIPES, TANKS
CPSC Indoor Air Pollution Book Online Copy

DIRECTORY of MOLD / ENVIRONMENTAL EXPERTS
DIRECTORY of OIL TANK EXPERTS
DIRT FLOOR MOLD CONTAMINATION
Disinfectants
Disinfecting Buildings with Bleach
DO IT YOURSELF MOLD CLEANUP
DRYWALL MOLD

DRAFT HOODS - gas fired
DRAFT MEASUREMENT, CHIMNEYS & FLUES
DRAFT REGULATORS, DAMPERS, BOOSTERS
DRINKING WATER
Diethylstilbestrol - DES
DUCT SYSTEM & DUCT DEFECTS
DUST ANALYSIS for FIBERGLASS
DUST CONTAMINATION FROM HVAC?
DUST SAMPLING PROCEDURE

EMERGENCY RESPONSE, INDOOR AIR, GAS, MOLD
EMF
EMF Cancer Scare
EMF RF FIELD & FREQUENCY DEFINITIONS
  Definitions of EMF EMR Terms
  Table of EMR Frequencies
  Cell phone Radiation Hazards
  Hertz - Definitions of KHz MHz GHz THz
EMF ELECTROMAGNETIC FIELDS & HUMAN EXPOSURE
EMF Levels of Cancer Risk
EMF MEASUREMENT INSTRUMENTS
EMF MEASUREMENT PROCEDURES
EMF SURVEY PROCEDURE - Details
References for Electromagnetic Fields and Cancer
WORKSHEET for EMF MEASUREMENTS
WORKSHEET for EMF MEASUREMENTS - Example
WORKPLACE EXPOSURE to Electromagnetic Fields

ENVIRO-SCARE - PUBLIC FEAR CYCLES

Fiberboard Insulation Sheathing Mold

Fiberglass Enviro-Scare
FIBERGLASS HAZARDS
  Fiberglass Insulation Exposure Limits
  FIBERGLASS PARTICLE CONTAMINATION TEST
  Recognizing Fiberglass Insulation
  Recognizing Fiberglass Duct Insulation
  Lab Identification of Fiberglass
  Fiberglass Fragment Hazards
  Fiberglass Detection in Building Air
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  References, Fiberglass Hazards
  Vacuuming exposed insulation
FIBERGLASS PARTICLE CONTAMINATION TEST

FIBERGLASS INSULATION MOLD
  CRAWLSPACE MOLD ADVICE
  INSPECTION of INSULATION for MOLD
  TEST CHOICES for MOLD in FIBERGLASS
  TEST PROCEDURE for MOLD in FIBERGLASS
  WHEN to TEST INSULATION for MOLD
  WHY DOES MOLD GROW in INSULATION?
FIBERGLASS PARTICLE CONTAMINATION TEST

Fireplace Inserts
Fireplaces & Woodstove Contaminants
FLAME COLOR, BLUE vs YELLOW COMBUSTION

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODS IN BUILDINGS-mold

FLOOR DAMAGE DIAGNOSIS
FLOOR TYPES & DEFECTS
FLOOR TILE ASBESTOS IDENTIFICATION
FLOOR TILE HISTORY & INGREDIENTS
Floor Tile, Asbestos, Photo ID Guide
FLOORING MATERIALS, Age, Types

FORMALDEHYDE HAZARDS
Formaldehyde Gas Hazard Reduction

GAS DETECTION & MEASUREMENT
  Drager gas sampling pump
  Colorimetric gas detection tubes
  GAUGE, REFRIGERATION PRESSURE TEST
  TIF 5000 Gas Detector
  TIF 8800 Gas Detector
  Warnings: gas detectors
  Warning: gas detector tubes

GAS EXPOSURE EFFECTS, TOXIC
  Allergens, common indoor
  Ammonia Gas
  Arsine Gas
  Bromine Gas
  Carbon Dioxide Gas
  Carbon Monoxide Gas
  Formaldehyde Foam Insulation UFFI
  Hydrogen Sulfide Gas
  LP & Natural Gas Safety Hazards
  LP & Natural Gas Pressures
  Methane Gas Safety Hazards
  Mycotoxin & MVOC Exposure
  Natural Gas Combustion Products
  Nitrogen Oxides Gas
  Oxygen - O2
  Ozone Warnings
  Ozone Gas Hazards
  Propane Gas or LP Gas
  Propylene Gas
  Sewer Gas
  Sulfur Dioxide Gas
  Urea Formaldehyde Foam Insulation UFFI
  Volatile Organic Compounds VOCs

GAS EXPOSURE LIMITS & STANDARDS
GASES, EXPOSURE TESTING
  Carbon Dioxide - CO2
  Carbon Monoxide - CO
  METHANE GAS SOURCES

GAS EXPOSURE TEST PROCEDURES
  Toxic Gas Test Selection
  Indoor Air Tests
  Particulate Testing
  Non-regulated particulates
  Toxic Gas Test Selection

GAS FIRED WATER HEATERS

GAS LP & Natural Gas Safety Hazards
GAS LP & Natural Gas Pressures
GAS PIPING, VALVES, CONTROLS

GAS MEASUREMENT TOOLS
  Drager gas sampling pump
  Colorimetric gas detection tubes
  GAUGE, REFRIGERATION PRESSURE TEST
  TIF 5000 Gas Detector
  TIF 8800 Gas Detector
  Warnings: gas detectors
  Warning: gas detector tubes

GAS TOXICITY LEVELS
  Gas Exposure Standards (Workplace)
  Gas Exposure Limits for Various Gases
  Volatile Organic Compounds - VOC Limits
  Gas Toxicity Footnotes

GAS PIPING, VALVES, CONTROLS
GLARE, Sunlight/Lighting Control
Goodman HTPV RECALL

HUMIDITY CONTROL & TARGETS INDOORS

HVAC Systems
  CHIMNEY INSPECTION DIAGNOSIS REPAIR
  HEATING SYSTEMS
HEATING OIL - OLD, USEABLE?
HEATING OIL PIPING TROUBLES
HEATING OIL SHELF LIFE
HEATING OIL SLUDGE
HEATING OIL USAGE RATE
HEATING OIL EXPOSURE HAZARDS, LIMITS
HOME HEATING SAFETY
HUMIDITY CONTROL & TARGETS INDOORS
House Dust Analysis

IAQ ISSUES, OTHER
Indoor Air Pollution Book Online CPSC
INDOOR AIR QUALITY & HOUSE TIGHTNESS

INDOOR AIR QUALITY IMPROVEMENT GUIDE
  AIR CLEANER PURIFIER TYPES
  Air Filter Effectiveness
  Air Filtering Strategies
  Air Pollutants, Health Effects
  Air Pollutants, Common Indoor
  Air Pollutants, Finding & Reducing
  Asbestos Hazards
  Backdrafting Appliances
  BIOLOGICAL POLLUTANTS
  BLUE vs YELLOW COMBUSTION FLAMES
  BLUERAY Recall
  BUY PRODUCTS for MOLD & ALLERGY CONTROL
  CABINETS & COUNTERTOPS
  CARPETING & INDOOR AIR QUALITY
  CHINESE DRYWALL HAZARDS
  Combustion Appliance Contaminants
  EMERGENCY RESPONSE, INDOOR AIR, GAS, MOLD
  FIBERGLASS HAZARDS
  Fireplace & Woodstove Contaminants
  Formaldehyde Hazards
  GAS EXPOSURE EFFECTS
  Gas Toxicity Levels
  Gases, Quick Guide to Indoor
  INDOOR AIR HAZARDS TABLE
  INDOOR AIR QUALITY IMPROVEMENT, KEY STEPS
  INDOOR COMBUSTION PRODUCTS & IAQ
  Lead Exposure Hazards
  LP & Natural Gas Safety Hazards
  LP & Natural Gas Pressures
  METHANE GAS SOURCES
  Natural Gas Combustion Products
  ODORS, Smells, Gases in Buildings
  Particles in Indoor Air - Chart
  Pesticide Exposure Hazards
  Radon Hazards
  Urea Formaldehyde Foam Insulation UFFI
  URETHANE FOAM Deterioration, Outgassing
  VENTILATION, BALANCED
  VENTILATION, EXHAUST ONLY
  VENTILATION, SUPPLY-ONLY
  VENTILATION, WHOLE HOUSE STRATEGIES
  Volatile Organic Compounds VOCs


INSULATION INSPECTION & IMPROVEMENT
INSULATION IDENTIFICATION GUIDE
INSULATION, ASBESTOS
INSULATION MOLD
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  MOLD PREVENTION AFTER FLOODING
  MOLD RESISTANT CONSTRUCTION
  Mold in Foam Insulation
  Moldy insulation may look clean
  Why does mold grow in fiberglass?
  When to test insulation for mold
  How to Test for Mold in Insulation
  References, Fiberglass Hazards
  Vacuuming exposed insulation
INSULATION MOLD RESISTANCE of FOAM
INSULATION, UFFI UREA FORMALDEHYDE FOAM

LEAD POISONING HAZARDS GUIDE
  Lead levels in blood
  How lead enters the body
  Sources of Lead
  Lead Based Paint
  Lead Paint Surveys
  Lead Plumbing Lead in Water
  Lead Toys, Jewelry
  Report on the National Survey of Lead-Based Paint
  Lead in Air - U.S. Lead Emissions Standards
LEAD CONTAMINATION HAZARDS in the HOME
  Protect Your Family from Lead
  Lead in Homes Before 1978
  Lead Hazard Warnings
  Lead in the Body
  Lead's Effects on People
  Extreme Lead Poisoning Symptoms, Effects
  Testing Your Family for Lead
  Lead-Based Paint Uses in Buildings
  Lead paint hazard spots in buildings
  Checking Your Home for Lead
  What You Can Do about Lead in the Home
  Remodeling & Lead Hazards
  Other Lead Sources
  Help Numbers for Lead Poisoning
  Government Contacts for Lead Info
LEAD CONTAMINATION in WATER, HOW to TEST
  Lead Contamination from Water Lines
  Lead in Water, Health Risks
  Lead Contamination Limits in Drinking Water
  Lead Test Results Affected by Test Methods
LEAD EXPOSURE HAZARDS INDOORS
LEAD HAZARDS & FEAR: Enviro-Scare
LEAD IN DRINKING WATER, HOW to REDUCE
  Lead in Drinking Water
  Health Effects of Lead
  Lead in Drinking Water
  Steps You Can Take
  Tests for Lead Contamination in Water
LEAD PAINT REMOVAL ALTERNATIVES
LEAD PAINT REMOVAL TROUBLES
LEAD PIPES in BUILDINGS
LEAD in ROOFING, EFFECTS
LEAD TEST KIT for HOME USE
LEAD WATER PIPING HAZARDS & REMEDIES
  Allowable Lead Levels in Water
  Lead Level vs. Test Methods

LEED Building Designation & IAQ

Legionella Legionnaires' Disease
Legionella BACTERIA & HVAC Equipment

LIGHTNING PROTECTION

LP & Natural Gas Safety Hazards

METHANE GAS SOURCES
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION

MOISTURE CONTROL in BUILDINGS
  MOISTURE CALCULATIONS
  MOISTURE METER STUDY
  MOISTURE PROBLEMS: CAUSE & CURE
  ROOF VENTILATION SPECIFICATIONS
  Roof Venting: Eaves Intake if no Overhang
  Roof Venting: Soffit Intake Vent-Continuous
  Roof Venting: Un-Vented Hot Roof Solutions
  ROOF VENTING ENERGY SAVING DETAILS
  ROOF VENTING NEEDED?
  VENTILATION DESIGN PROBLEMS & SOLUTIONS
  VENTILATION, WHOLE HOUSE STRATEGIES

MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD ACTIVITY in BUILDINGS
MOLD AGE - Old is the Mold?

MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD

MOLD ATLAS & PARTICLES INDEX
MOLD by MICROSCOPE
MOLD in the PETRI DISH, PHOTOS
Mold on Books, Book Conservation

MOLD CLASSES, HAZARD LEVELS

MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP - BLEACH
MOLD CLEANUP - HEALTH RISKS
MOLD CLEANUP - LIMITATIONS
MOLD CLEANUP - MISTAKES to AVOID
MOLD CLEANUP - MEDIA BLASTING
MOLD CLEANUP - SAFETY WARNINGS
MOLD CLEANUP - WOOD FLOORING
MOLD CLEANUP - WOOD FRAMING & PLYWOOD

MOLD CLEARANCE INSPECTIONS
MOLD CLINICAL REFERENCE TEXTS
MOLD CONSULTANTS/INSPECTORS
MOLD CONTAMINATION LEVELS

MOLD CULTURE PHOTOS
MOLD CULTURE TEST KIT VALIDITY
MOLD CULTURE SAMPLING METHOD

MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTORS - ENVIRONMENTAL MEDICINE

MOLD or INDOOR AIR EMERGENCY RESPONSE
MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE, FOOD HAZARDS
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS

MOLD FAQ's
MOLD FREQUENCY in BUILDINGS
MOLD GROWTH ON SURFACES, PHOTOS
MOLD GROWTH on SURFACES, TABLE OF
MOLD GROWTH in/on BUILDING INSULATION

MOLD INFORMATION CENTER
MOLD INSPECTORS & MOLD TESTERS
MOLD INSPECTION SERVICE
MOLD INVESTIGATION PROCEDURE TIPS
MOLD INVESTIGATION REPORTS

MOLD KILLING GUIDE
MOLD LAB REPORTS
MOLD LEVEL IN AIR, VALIDITY
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS
MOLD by MICROSCOPE

MOLD ODORS, MUSTY SMELLS
MOLD on or in CARPETS
MOLD ON DIRT FLOORS

MOLD PREVENTION GUIDE

MOLD RELATED ILLNESS GUIDE
MOLD RELATED ILLNESS SYMPTOMS
MOLD RESISTANT CONSTRUCTION

MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS

MOLD TOXICITY VARIATION

MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST METHODS, ACCURACY
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES

MSDS Material Safety Data Sheets
  Chemicals, Cleaners MSDS
  Drwyall MSDS
  Gases in Buildings MSDS
  Heating Fuels, Controls, Oil, Crude Oil, Gas MSDS
  Insulation Products MSDS
  Fiberglass Insulation Exposure Limits
  Mold Related Products MSDS
  Paint / Sealant MSDS
  Septic Dye MSDS
  Septic & Holding/RV Tank/Toilet Chemicals MSDS
  Smoke Generator Chemicals Powders MSDS
  Water Purification Products MSDS
  Wood Construction Products MSDS

MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE

Museum Artifact Preservation

Nanomaterials Hazards

NOISE / SOUND DIAGNOSIS & CURE
  Air Leak Noises
  AIR CONDITIONING & HEAT PUMP NOISES
  Animal Noises
  Appliance Noises
  Chimney noises
  Door Options for Sound Reduction
  Duct Insulation for Soundproofing
  DUCT VIBRATION DAMPENERS
  Dripping Water Sounds
  Electric Motor Noises
  Electrical System Noises
  Fan Noise Control
  Flanking Pathways for Sound
  Floor Noises
  FLOOR NOISE CONTROL
  GAS BURNER Flame & Noise Defects
  Hearing Disabilities & Building Noises
  HEALTH RELATED NOISE COMPLAINTS
  HEATING SYSTEM NOISES
  HISSING NOISES
  Insect Noises in Buildings
  OIL BURNER NOISE SMOKE ODORS
  PLUMBING DRAIN NOISE DIAGNOSIS
  PLUMBING DRAIN NOISE REPAIR
  PLUMBING NOISE CHECKLIST
  PLUMBING NOISE CONTROL
  ROOF NOISE TRANSMISSION
  SIDING NOISES
  Sound Control Measures
  Stair & Step Noises
  Structure Noise Transmission
  Temperature-Change Noises
  Wall Noise Transmission
  WATER HEATER NOISES
  Wind Noises
  Window & Door Noises
NOISE CONTROL for FLOORS
NOISE CONTROL for HEATING SYSTEMS
NOISE CONTROL for PLUMBING
NOISE CONTROL for ROOFS
NOISE CONTROL for WALLS
NOISE, PLUMBING CHECKLIST
NOISE, PLUMBING DRAIN DIAGNOSIS
NOISE, PLUMBING DRAIN REPAIR
NOISES, WATER HEATER
NOISES, WATER PUMP


ODORS GASES SMELLS, DIAGNOSIS & CURE
  ANIMAL ODORS IN BUILDINGS
  BOAT & CAR SMELLS & ODORS
  CARBON MONOXIDE - CO
  CARPETS & PADDING ODORS IN BUILDINGS
  CAT DANDER in BUILDINGS
  CHINESE DRYWALL HAZARDS
  DUCT & AIR HANDLER ODORS
  FLOOR DRAIN / TRAP ODORS
  GALVANIC SCALE & METAL CORROSION
  GAS MEASUREMENT TOOLS
  HEATING OIL EXPOSURE HAZARDS, LIMITS
  HEATING SYSTEM ODORS
  HOUSEWRAP AIR & VAPOR BARRIERS
  HYDROGEN SULFIDE GAS
  METHANE GAS SOURCES
  MOLD ODORS, Musty Smells in Buildings
  MOLD ODORS in Cars
  MVOCs & MOLDY MUSTY ODORS
  MYCOTOXIN EFFECTS of MOLD EXPOSURE
  ODOR DIAGNOSIS CHECKLIST
  ODORLESS CHEMICALS / GASES: CHECK FOR?
  ODORS, SEPTIC or SEWER
  ODORS, SULPHUR SMELL SOURCES
  ODORS, URINE REMOVAL
  ODORS IN WATER
  ODORLESS CHEMICALS / GASES: CHECK FOR?
  OIL HEAT ODORS
  OIL ODORS, LEAKY OIL TANK PIPING
  OIL TANK LEAK ODORS
  OZONE for MOLD OR ODORS
  PAINTS & COATINGS ODORS IN BUILDINGS
  PARTICLE SIZES & IAQ
  Particulates & Allergens Indoors
  Pesticide Exposure Hazards
  PET ALLERGEN REMEDIES
  PLASTIC CONTAINERS, TANKS, TYPES
  PLASTIC HEATER VENT
  PLASTIC ODORS-SCREENS, SIDING
  PLUMBING SYSTEM ODORS
  SEPTIC METHANE GAS
  SEPTIC SYSTEM ODORS
  SEWER GAS ODORS
  SEWER GAS ODORS in COLD WEATHER
  SICK HOUSE IAQ QUESTIONNAIRE
  SMELL PATCH TEST to Track Down Odors
  SULPHUR & SEWER GAS SMELL SOURCES
  TOXIC GAS TEST PROCEDURES
  VINYL Siding or PLASTIC Window ODORS in Buildings
  VINYL CHLORIDE HEALTH INFO
  Volatile Organic Compounds VOCs
  WATER BARRIERS, EXTERIOR BUILDING
  WATER ENTRY in BUILDINGS
  WATER ODORS, CAUSE CURE
  WELL WATER CONTAMINANT SOURCES

OIL, HEATING, EXPOSURE HAZARDS, LIMITS
OIL HEAT ODORS
OIL SPILL CLEANUP / PREVENTION
OIL TANK LEAK ODORS

OIL TANKS
OIL TANK ABANDONING PROCEDURE
OIL TANK AGE
OIL TANK, BURIED, ADVICE
OIL TANK, BURIED, FINDING
OIL TANK FAILURE CAUSES
OIL TANK FAILURE RATES
OIL TANK FLOATING UP
OIL TANK GAUGES
OIL TANK INSPECTION, ABOVE GROUND
OIL TANK INSPECTION REPORTS
OIL TANK LEAKS & SMELLS
OIL TANK LEGAL ISSUES
OIL TANK LIFE
OIL TANK PIPING & PIPING DEFECTS
OIL TANK PRESSURE
OIL TANK REGULATIONS
OIL TANK REMOVAL COs
OIL TANK REMOVAL FINANCIAL AID
OIL TANK REPORT LANGUAGE
OIL TANK SAFETY
OIL TANK SLUDGE
OIL TANK STANDARDS
OIL TANK SPILL CLEANUP / PREVENTION
OIL TANK SUPPORT
OIL TANK TESTING
OIL TANK TESTING COs
OIL TANK WATER CONTAMINATION
OIL TANK WATER REMOVAL

OXYGEN - O2
OZONE HAZARDS
OZONE for MOLD OR ODORS

PAINTS & COATINGS ODORS IN BUILDINGS

PARTICLE SIZES & IAQ
Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
Pet Dander
PLASTIC CONTAINERS, TANKS, TYPES
PLASTIC HEATER VENT
PLASTIC ODORS-SCREENS, SIDING
PLUMBING SYSTEM ODORS
Pollen Photos
PVC - VINYL BUILDING PRODUCTS

RADON HAZARD TESTS & MITIGATION
Radon Enviro-Scare

ROT, FUNGUS, TERMITES

SAFETY HAZARDS GUIDE
SAFETY HAZARDS & INSPECTIONS
  MSDS Material Safety Data Sheets
  SAFETY: Elderly & Veterans Home Safety

SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
SEPTIC METHANE GAS
SEPTIC SYSTEM ODORS

SEWAGE BACKUP TEST & CLEANUP
SEWAGE & SEPTIC CONTAMINANTS
SEWAGE CONTAMINATION in BUILDINGS
SEWAGE CONTAMINANTS in FRUIT / VEGETABLES
SEWAGE NITROGEN CONTAMINANTS
  NITROGEN CONTAMINATION
  NITROGEN REFERENCES
SEWAGE PATHOGENS in SEPTIC SLUDGE
  Components Entering a Septic Tank
  Components of Raw Sewage
  Components of Septic Tank Effluent
  Settled septic tank sludge
  Floating septic tank scum
  Gases in the septic tank
SEWAGE PUMPS
SEWAGE PUMP CLOG DAMAGE
SEWER BACKUP PREVENTION
SEWER GAS ODORS
SEWER GAS ODORS in COLD WEATHER

SICK HOUSE IAQ QUESTIONNAIRE
SIDING VINYL
  VINYL SIDING INSPECTION & REPAIR
  VINYL SIDING INSTALLATION
  VINYL Siding or PLASTIC Window ODORS in Buildings
  VINYL CHLORIDE HEALTH INFO
SMELL PATCH TEST to Track Down Odors

SOLAR ENERGY SYSTEMS
SOUND CONTROL in BUILDINGS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on BUILDINGS - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAINS & Thermal Tracking

SULPHUR & SEWER GAS SMELL SOURCES

THERMAL TRACKING Indicates Heat Loss

UFFI UREA FORMALDEHYDE FOAM INSULATION
URETHANE FOAM Deterioration, Outgassing

VAPOR BARRIERS & AIR SEALING at BAND JOISTS
VAPOR BARRIERS & CONDENSATION in BUILDINGS
  ATTIC CONDENSATION CAUSE & CURE
  BASEMENT CEILING VAPOR BARRIER
  CONDENSATION or SWEATING PIPES, TANKS
  CRAWL SPACE VAPOR BARRIER
  DEW POINT CALCULATION for WALLS
  DEW POINT TABLE - CONDENSATION POINT GUIDE
  FELT 15# ROOFING, as HOUSEWRAP/VAPOR BARRIER
  HOUSEWRAP AIR & VAPOR BARRIERS
  HOUSEWRAP INSTALLATION DETAILS
  HOUSEWRAP PRODUCT CHOICES
  HOUSEWRAP at SILLS, SOLES, TOP PLATES
  HUMIDITY LEVEL TARGET
  MOISTURE CONTROL in BUILDINGS
VAPOR BARRIERS & HOUSEWRAP
VAPOR CONDENSATION & BUILDING SHEATHING

VENTILATION in BUILDINGS
  Air Bypass Leaks, Thermal Tracking
  AIR CHANGE RATE ACH HEAT SAVINGS
  ATTIC CONDENSATION CAUSE & CURE
  BALANCED VENTILATION, HEAT COST SAVINGS
  BATHROOM VENTILATION
  Blocked Soffit Intake Vents
  CATHEDRAL CEILING VENTILATION
  CLOTHES DRYER VENTING
  COOLING LOAD REDUCTION by ROOF VENTS
  CRAWL SPACE VENTING & Dryout Procedures
  HOT ROOF DESIGNS: Un-Vented Roof Solutions
  HUMIDITY LEVEL TARGET
  ICE DAM PREVENTION
  HOUSE DOCTOR, how-to be
  MOISTURE CONTROL in BUILDINGS
  ROOF VENTILATION SPECIFICATIONS
  Roof Venting: Eaves Intake if no Overhang
  Roof Venting: Soffit Intake Vent-Continuous
  Roof Venting: Un-Vented Hot Roof Solutions
  ROOF VENTING ENERGY SAVING DETAILS
  ROOF VENTING NEEDED?
  SKYLIGHT VENTILATION DETAILS
  Soffit Ventilation
  VENTILATION, BALANCED
  VENTILATION, BALANCED HEAT COST SAVINGS
  VENTILATION DESIGN PROBLEMS & SOLUTIONS
  VENTILATION, EXHAUST ONLY
  VENTILATION, SUPPLY-ONLY
  VENTILATION, WHOLE HOUSE STRATEGIES

VINYL CHLORIDE HEALTH INFO
VINYL Siding or PLASTIC Window ODORS in buildings
Volatile Organic Compounds VOCs

WATER ODORS, CAUSE CURE
WATER TESTS, CONTAMINANTS, TREATMENT
  Contaminant Level
  Cheat on tests
  Correcting Unsatisfactory
  Lead Supply Lines
  Reduce Lead Contamination
  Shock a Well, How
  Supply & Drain Piping
  Water Requirements
  Water Test Advice
WATER TEST CHOICES & WATER TEST FEES
WATER TREATMENT EQUIPMENT CHOICES
Well Pollution

WIND TURBINES & LIGHTNING
World Trade Center Collapse Dust Photos

More Information

Unidentified chemical drums discovered during a home inspection might indicate an environmental site contamination hazard. Indoor Environmental Hazard Detection, Testing, Cleanup, Illness, Symptoms, Diagnosis
InspectAPedia®  -      

  • Indoor Air quality, gas testing, mold contamination, sewage backups, water contamination, other health & safety topics
  • Environmental & health/safety hazard topic links at page left
  • Environmental contamination & safety advice for home owners & home buyers
  • Questions & answers about detecting, testing for, and removing environmental hazards found in or around buildings.

This website provides consumer advice on indoor and building related environmental hazard inspection, detection, remediation. These articles explain building indoor environmental hazard inspection, detection, and remediation procedures giving advice from un-biased experts. Example topics include explanation, testing and remedy procedures for building hazrds from: asbestos, mold, IAQ, toxic gases, fiberglass, sewage backups, bacterial hazards, lead, radon, UFFI, noise pollution, oil spills, odors & smells, ozone, other potential building indoor contaminants.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Environmental Hazard Testing, Effects, Remedies, Prevention Articles

See building environmental topic links at page left or scroll down. In these articles we give inspection, testing, and cleanup as well as prevention advice for: Allergens indoor, Animal dander, Asbestos, Carpet dust, Cell Phones, Carbon Monoxide, Disinfectants, Drinking Water, EMF, Electromagnetic Fields, Electrical Hazards, Exteriors of buildings, Fragrances, Fiberglass particles and Fiberglass Insulation, Fiberglass mold contamination, Formaldehyde, Toxic Gases, Hazmat maps, Indoor Air Quality Testing & Improvement, Lead paint, lead in water, MCS, multiple chemical sensitivity, Mold inspection, testing, cleanup, prevention, MVOCs, Odors, Oil Tanks buried/above ground, Pet illness, Rodents mice urine fecals dust, Septic Systems, Sewage spills sewage contamination, Smells & Odors, odor source detection, sewage and septic odors, UFFI or Urea Formaldehyde Foam Insulation, Water contamination testing and correction.

The photo above shows steel chemical drums that we discovered on a residential property during a home inspection. Not only did these steel drums raise a question of possible environmental contamination of this site, even worse, they were uphill and close to a stream, raising a still more broad question of area contamination.

Go directly to: Asbestos - EMF - Fiberglass - Gases - Chimneys - IAQ - Lead - Mold Insp Test - Oil Tanks - Septic - Water - or use links at page left for our full list of environmental topics

  • New AIR FILTERS, OPTIMUM INDOOR choices of filter types and filter location for optimum indoor air quality (IAQ) on hot air heating and air conditioning systems
  • Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
  • ASBESTOS IDENTIFICATION IN BUILDINGS provides a detailed guide to recognizing asbestos-containing materials in buildings and links to in depth articles about individual asbestos-containing building materials
  • ASBESTOS FLOOR TILE PHOTO ID GUIDE - detailed photo guide to asphalt asbestos and vinyl asbestos floor tiles, 1900 -1986
  • ASBESTOS List of Asbestos-Containing Products provides our detailed list of known products in which asbestos was used
  • ASBESTOS Photo Guide to Materials / Products provides a photo guide to common asbestos-containing products
  • Asbestos HVAC Ducts and Flues field identification photos and guide
  • Asbestos Transite Pipes, Chimneys & Flues and safety hazards in buildings
  • Asbestos Transite Pipe HVAC Ducts and safety hazards in buildings
  • Asbestos Under the Microscope
  • BPA - Bisphenol-A or BPA, endocrine disruptor widely used in certain plastics, food containes, many other products
  • Cad Cell Relay Switch Flame Sensors - readers Q&A lists some sources of cadmium in the home
  • Careers in Environmental Science: list of resources, potential jobs, work areas on environmental topics and using environmental science, chemical, engineering, or environmental science degree
  • Carpet Dust or Dust from HVAC? An Investigation of Indoor Dust Debris Blamed on a Heating/Cooling System Reveals Carpet Dust
  • Cell phones cellular phone towers and possible health or cancer risks
  • Certifications & Training for environmental testing & Cleanup: Watch out for environmental testing and cleanup that are not performed by qualified experts. Details & examples of what can go wrong are at ASBESTOS REMOVAL, Amateur, Incomplete and Asbestos Removal, Certification.
  • Chernobyl Nuclear Plant flaws in the Chernobyl Nuclear Facility before the reactor meltdown
  • Disinfectants and Sanitizers in HVAC systems - use of, U.S. EPA advice
  • Drinking Water Quality, Testing, and related health concerns: Inspection, Maintenance, Repairs, Product Failures
  • Drinking Water Supply, Contamination Levels, Water Testing Procedures
    • Drinking Water testing, contamination, correction - all topics
    • Drinking Water Testing Advice for home buyers home owners home inspectors
    • Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters
    • Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid General water testing and corrective measure advice: contact your local health department
    • Interpreting Drinking Water Test Results Correcting Contaminated or Unsatisfactory Water Drinking Water Contamination and Pollution How to Detect, Test, Correct, and Prevent Well Water Contamination - US EPA - Groundwater
    • Drinking Water Contaminant Levels - Maximum Allowed How to Reduce Lead Contamination in Drinking Water: how to test & correction lead in drinking water
    • Lead Contamination from Water Supply Lines/Entry Mains, Lead Testing & Correcting Contamination from - Lead Pipe Problems/Advice
    • When and How to Shock or Chlorinate a Well - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
    • Extreme Lead Poisoning Symptoms Suggested by Feb 2006 NY Times Article on Kosovo Roma Camps
    • Water and Waste Water Test Methods, US EPA
    • Water Requirements, Home & Outdoor Living ATSDR: Nitrate/Nitrite Toxicity [Big, Slow-Loading File] U.S. Government ATSDR Science Corner - 2.5MB PDF
    • Water Supply & Drain Piping, wells, Pumps, Water Supply Equipment, and Septic Systems Information Website, septic system maintenance, inspection, testing, repair, & alternatives, preventing septic system failures
  • DUCT SYSTEM & DUCT DEFECTS - how to find, clean up or remove, or prevent contamination problems and indoor air quality problems in duct systems: asbestos, fiberglass, flooding, mold, water, and other duct contaminants

  • Electromagnetic Fields, Cancer, and Enviro-Scare: the relation of cycles of public fear and property values for Asbestos, UFFI, Radon, EMF, Lead hazards - "Enviro-Scare" - The Normal Curve Cycle of Public Fear of Environmental Issues
  • Electromagnetic Field Measurement Procedures, a Recommended Electromagnetic Field EMF Survey Protocol and Procedure to document site conditions and to improve measurement reliability for the assessment of potential EMF exposure risks
  • Electromagnetic Fields in the Workplace a good NIOSH document on EMFs, links to other NIOSH docs.
  • Environmental Illness, support and health info database [this link is under revision--DF 1/06]
  • ENVIRONMENTAL REGULATIONS, New Jersey - Update on New Jersey Environmental Regulations that impact real estate transactions, courtesy of Gregory Brown, P.E.
  • EXTERIORS of BUILDINGS: conditions contributing to moisture, mold, mildew, mites, insects, water entry, ice dam leaks, basement water entry, dampness, and related health concerns for allergy and asthma or other respiratory distress
  • Fiberglass Insulation Exposure Limits
  • FIBERGLASS HAZARDS - how to recognize potential fiberglass dust hazards, how to test buildings for fiberglass dust levels
  • FIBERGLASS INSULATION - how to identify, install, and use fiberglass insulation in buildings and HVAC systems
  • Fiberglass carcinogenicity: Glass Wool Fibers Expert Panel Report, Part B - Recommendation for Listing Status for Glass Wool Fibers and Scientific Justification for the Recommendation", The Report on Carcinogens (RoC) expert panel for glass wool fibers exposures met at the Sheraton Chapel Hill Hotel, Chapel Hill, North Carolina on June 9-10, 2009, to peer review the draft background document on glass wool fibers exposures and make a recommendation for listing status in the 12th Edition of the RoC.

    The National Institute of Environmental Health Sciences is one of the National Institutes of Health within the U.S. Department of Health and Human Services. The National Toxicology Program is headquartered on the NIEHS campus in Research Triangle Park, NC.
  • Fiberglass insulation mold: occurrence of mold contamination in fiberglass insulation can be impossible to see with the naked eye, but can be significant
  • Fragrances, and burning scented candles can deposit "soot-like" marks on walls/ceilings and can contribute to health and respiratory complaints. Sometimes the soot marks (thermal tracking) left burning candles, especially scented candles, is mistaken for mold on surfaces. [In Process - DJF]
  • Flooding: Mold Action Guide after Flooding: How to Minimize Mold Damage After a Building Flood
  • FORMALDEHYDE HAZARDS - exposure sources, exposure limits, reducing exposure

  • Gases: Toxic gases, indoor exposure levels, testing, identification
    • Carbon Dioxide - CO
    • Carbon Monoxide - CO
    • Gas Toxicity Levels - at what level is exposure to a particular gas considered hazardous or toxic?
    • Gas Exposure Limits - what are the allowable toxic gas exposure levels? OSHA, NIOSH, etc.
    • Volatile Organic Compounds - issues of exposure to VOC's and MVOC's from mold
    • TOXIC GAS EXPOSURE EFFECTS - what are the effects on humans when exposed to various levels of various gases?
    • Ammonia Gas exposure effects on humans
    • Arsine Gas exposure effects on humans
    • Bromine Gas exposure effects on humans
    • Carbon Dioxide Gas exposure effects on humans
    • Carbon Monoxide Gas exposure effects on humans, sources, safety, treatment
    • Hydrogen Sulfide Gas sources, effects on humans, sources
    • METHANE GAS SOURCES Methane gas, LP gas, natural gas uses, sources, detection, hazards in & around buildings
    • Nitrogen Oxides Gas exposure effects on humans
    • Ozone Gas exposure effects on humans
    • Propylene Gas exposure effects on humans
    • Sewer Gas exposure, effects on humans, sources
    • SULPHUR & SEWER GAS SMELL SOURCES list of sources of sulphyr & sewer gas odors in buildings
    • Sulfur Dioxide Gas exposure effects on humans
    • TOXIC GAS TEST PROCEDURES for screening non-workplace environments
    • Toxic Gas Test Selection suggestions for choice of instrument and method
    • Indoor Air Tests for mold, particulates, gases, odors, chemicals
    • Particulate Testing for house dust, mold, allergens, fiberglass, other problem particles
    • Non-regulated particulates - what exposure standards or limits should we consider
    • Common indoor allergens - how to test for and recognize dust mites, animal allergens, mold, etc.
    • Oxygen - O2- details effects of exposure at high levels
    • Ozone Warnings regarding use of ozone generators for odor removal or mold control
    • Ozone Hazards - risks to humans when ozone is used indoors
    • Sampling for gases in air such as VOC's, MVOC's, toxic chemicals, and combustion products.
      Unfortunately no single test or tool can detect all possible building contaminants. We use methods and equipment which can test for common contaminants. If the identity of a specific contaminant is known in advance we can also test for a very large number of specific contaminant gases in buildings.

      We use gas sampling equipment provided by the two most reliable companies in the world, Draeger-Safety's detector-tubes and Drager accuro™ bellows pump, the Gastec™ cylinder pump and detector-tube system produced by Gastec or Sensidyne, and we also use Sensidyne's Gilian air pump.

      For broad screening for combustibles and a number of other toxic gases and for leak tracing we also use Amprobe's Tif 8850 and TIF 8800. All of these instruments, their applications, and sensitivities (minimum detectable limits) for specific gases are described in our Gas Sampling Plan online document.
    • Radon Gas U.S. EPA Radon level maps
  • Granite Countertops and Radiaton Hazards? Q&A and some advice from the US EPA
  • Hazardous Material Waste Site Maps from ATSDR - U.S. CDC Gather - "Geographic Analysis Tool for Health and Environmental Research" online public access to data pertinent to public health

  • Heating, Cooling, Air Filtration, Air Conditioning - common sources of both bioaerosol reservoirs and mold amplification in buildings [In Process-DJF]
    • Air Conditioning system diagnosis and repair
    • Chimneys, Flues, Woodstoves & Fireplaces: Safety Concerns, safe and proper venting of combustion gases, carbon monoxide hazards
    • Disinfectants and Sanitizers in HVAC systems - use of, U.S. EPA advice
    • HEATING SYSTEMS: Inspection methods, Product Warnings
    • HEATING OIL EXPOSURE HAZARDS, LIMITS exposure risks, hazards, allowable exposure limits for home heating oil
    • Heating System Safe and Unsafe Venting & CARBON MONOXIDE - CO - article by DJF on CO testing devices and the calculation of allowable carbon monoxide leakage from gas fired furnaces (Original: ASHI Technical Journal)

  • NewHumidity Control in Buildings: What is the proper level for indoor humidity and how do we obtain it in buildings? How Low Should You Keep Indoor Humidity to Avoid a Mold Problem

  • INDOOR AIR QUALITY & HOUSE TIGHTNESS - do air tight homes mean bad indoor air quality? causes of variation in IAQ;
  • INDOOR AIR QUALITY IMPROVEMENT GUIDE in-depth article series on strategies for cleaning up indoor air and other indoor hazards
  • INDOOR AIR QUALITY METHODS COMPARED comparing various air quality inspection and test methods shows which ones are reliable and which should not be trusted
  • INSULATION IDENTIFICATION GUIDE
  • Insulation Mold in Fiberglass - occurrence of hidden Penicillium & Aspergillus contamination in fiberglass insulation
  • Insulation Mold Resistance of Foam - resistance of some foam insulation products to moisture & mold

  • Urea Formaldehyde Foam Insulation UFFI - is UFFI a health hazard? how good an insulation product was it anyway?

  • Lead Hazards: Advice, evaluation, mitigation, services - lead paint, lead in plumbing, lead in water, air, dust
    • How to Protect Your Family from Lead in Your Home U.S. CPSC publication with additional links and resource references
    • Lead Hazards in Buildings, Dust, Paint, Water: General Advice, Testing Procedures, Illnesses with additional links and resource references for Lead Hazards
    • Lead in Drinking Water : Advice
    • Lead Testing & Correcting Contamination from Lead Water Supply Lines/Entry Mains - Lead Pipe Problems/Advice
  • Legionella sp. Health Concerns and advice, cleaning air conditioning systems, when to test for Legionella
  • METHANE GAS SOURCES - including methane in water supply, wells, water heaters, septic tanks, sewer systems

  • MILDEW in BUILDINGS ? - does mildew grow in buildings or on building surfaces? What to do about mildew: mildew cleanup, mildew cure, mildew prevention.

  • Mold, Toxic or Allergenic Inspection, Testing, Remediation, Prevention
    • What to do about mold in buildings Main page for this topic

    • GO TO Mold Test Kit Source: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!Use this simple, economical mold test kit by following our instructions on how to collect and mail mold samples to a lab of your choice

    • Action Guide for Mold: easy step by step what to do about mold.
    • BUYERS GUIDE - home inspections for mold - when where how and why to check for mold in a building being purchased
    • Clinical Atlas of Mold Toxicity - An Online Description of Toxic, Pathogenic, Allergenic Fungi, Fungal Diseases, and A List of Mold Related Illness Symptoms & Complaints
    • Common Indoor Molds Found in Buildings, Table of most frequent molds in surface samples
    • Flooding: Mold Action Guide after Flooding: How to Minimize Mold Damage After a Building Flood
    • Floods in Buildings Basic steps - how prevent mold contamination after a building flood
    • Hiring a mold or IAQ consultant - When to Hire Someone
    • House Dust from an HVAC system frightened building occupants unnecessarily
    • How to Find a Mold or IAQ Consultant, to guide the mold remediation & mold cleanup
    • How to Look For Indoor Mold & Other Indoor Contaminants
    • How to Recognize Indoor Mold - what mold looks like, mold identification photos - choosing what to sample, stuff that is not mold but is often mistaken for it, examples of harmless black mold
    • How to use Your Flashlight to Look for Mold - Proper use of lighting discloses hard to see but toxic light or white mold colonies on walls.
    • How to Prevent Mold - priorities, repairs, products
    • How to Test For Mold - Which Mold Testing Methods are Valid & Which are a Waste of Time and Money
    • How to send a mold test sample to our mold testing laboratory
    • Mold Classes, & Mold Contamination Levels - Degrees of Severity of Mold Contamination in Buildings and in Lab Samples
    • Mold-Resistant Building Practices - "Mold-proof" construction methods
    • Mold Removal by Media Blasting - A test report (complete article, with illustrations) on the effectiveness of baking soda media blasting for cleaning fungal contamination in buildings
    • Other Indoor Air Quality Concerns - Allergens, Animals, Asbestos, Carpets, Fiberglass, Toxic Gases, MVOCs, Humidity levels, Lead, Pollen, Rodents, Sewage Backups
    • Reporting the Results of Mold and IAQ Investigations, what should be included in your mold inspection and mold test report to make it useful
    • Technical & Laboratory Procedures for examining mold
    • Products to Reduce or Remove Mold & Allergic Materials to reduce exposure to allergens and improve indoor air quality
    • MOLD FAQ's - find a quick answer to your mold concern

  • MSDS Material Safety Data Sheets
  • Museum Artifact Preservation - Cultural Heritage and Aerobiology, Methods and Measurement Techniques for Biodeterioration Monitoring - museum painting and artifact preservation advice, Book Review

  • NOISE / SOUND DIAGNOSIS & CURE - Noise & Sound Control in Buildings: how to track down and fix the sources of problem-levels or annoying building noises and sounds

  • ODORS GASES SMELLS, DIAGNOSIS & CURE - Odor Diagnosis & Cure in Buildings: how to track down the sources of building smells or odors and how to remove them

  • Odors, Odor Detection, Smells, & Gases how to find and identify sources of noxious or toxic odors and gases
    • Animal Smells may be due to current or prior pets in a building, pet urine or fecal waste, cat boxes, animal hair, dog dander, cat dander (are allergens and are indicators of the level of prior pet activity), dust tracked in by dogs. But animal odors in buildings can also occur when an animal such as a mouse or rat has died in a building cavity. A dead animal smell has been described by our clients with a wide variety of terms ranging from a vague noxious stink that seemed to vary with humidity to a sweet sickly smell. Dead animals or even insect nests in building plumbing, especially building vents, can also produce unexpected sewer odors - see Septic and Sewer gas odor links discussed below.
    • BOAT & CAR SMELLS & ODORS - smells inside of an automobile, camper, RV, or truck may be due to a range of problems ranging from dangerous burning brakes or an actual engine fire, to leaks in the climate control system, to hard-to-cure mold contamination of carpeting, seating, headlines, and sound proofing. This article explains the range of causes of odors in vehicles, what they might mean, and how best to get rid of the offensive, unhealthy, or unsafe smell.
    • Drain Odors: Plumbing Drain Noises - Diagnosis & Repair guide. This article discusses the cause, diagnosis, and cure of plumbing drain noises. A drain noise can also be a clue to plumbing drain odor sources. That "blub blub" or "glug glug" noise you hear from a building drain might mean that there is a problem with the drain system itself, such as a partial drain blockage, a drain venting problem, a drain odor problem, or even a failing septic system. This article explains the causes and cures for plumbing drain noises, and we refer to key companion articles that assist in that diagnosis.
    • Ductwork odors: (DUCT & AIR HANDLER ODORS) odors in HVAC ducts, air handlers, blowers, for both warm air heating and air conditioning systems can be traced to a variety of sources such as leaks and mold in the duct system, a leaky (and unsafe) heat exchanger sending flue gases or even carbon monoxide into building air (see CARBON MONOXIDE - CO and HEAT EXCHANGER LEAKS), dead animals in the ducts or air handler, or even a bad blower motor that is overheating. Also see OIL HEAT ODORS, as well as OIL BURNER NOISE SMOKE ODORS.
    • Gas Odors: A Toxic Gas Testing Sampling Plan for Residential Indoor Air Investigations. This document outlines gas toxicity levels and gas testing procedures we use in field IAQ and environmental health investigations for a range of indoor gases which may be produced by building product outgassing, mold and MVOCs, mechanical systems, fire damage, or contamination from nearby industrial, beauty parlor, dry cleaning, or other activities which often produce noxious or toxic odors and gases.
    • Mold Odors or Smells: This website provides information and procedures for finding, testing, cleaning and preventing indoor mold, toxic black mold, green mold, testing building indoor air quality, and other sick house / sick building investigations. Here are research articles, inspection and testing procedures, and contact information for expert services.

      We give in-depth information about indoor air quality problems: causes of respiratory illness, asthma, or other symptoms such as neurological or psychological problems, air quality investigation methods, and remediation procedures such as mold cleanup, handling toxic mold contamination, and building or mechanical system repairs. We offer advice on mold prevention and mold-resistant construction resistant to indoor problem molds such as the Aspergillus sp., Penicillium sp. and Stachybotrys chartarum groups.
    • Mold Odors: If we smell mold, is mold present and is that a problem? Most people have a pretty good idea of moldy or musty smell as associated with mold. If you smell mold or find it at important levels in screening samples of air, dust, or vacuumed surfaces, (by quantity or by particle type in samples) it is probably there.
    • Mold Odors: Why do mold odors occur in our home following rain? Odors at exterior outlets sure sound as if there has been leakage into the wall and a probable mold colony.

      We need an expert visual inspection and possibly invasive sampling, combined with building history, to find and follow leak paths and high humidity cavities in order to inspect the most-likely mold reservoir targets in a building. The odors may be MVOC's which may be produced by some mold genera/species at varying levels as humidity, temperature, air pressure, and other variables change.
    • OIL ODORS, LEAKY OIL TANK PIPING at the oil storage tank filler or vent piping can be diagnosed and repaired
    • OIL TANKS INSPECT LEAK TEST ABANDON REGS -Heating Oil Underground & Above ground Oil Storage Tank Leaks, Testing, Problems & Solutions, Home Buyer's / Home Owner's Guide
    • Oil Tank Leaks and Smells, testing, inspection, abandonment, replacement are discussed at our website on handling above ground or buried heating oil storage tanks. These online articles answer most questions about above ground or buried oil storage tanks.

      Extensive free un-biased oil storage tank inspection and testing advice for property buyers and owners. This document lets you know what to ask about oil storage tanks, what oil tank leak tests to order, how to interpret oil tank testing results, what to do if there is a buried fuel or petroleum storage tank at a property, what to do if there is or was a leaky oil storage tank or petroleum storage tank, and how to reduce the chances of an oil leak or oil spill in the future.

      We include detailed information about underground (buried) oil storage tanks (USTs), aboveground oil storage tanks (ASTs), above ground fuel storage tanks, reporting and cleaning up oil tank leaks, and choosing among oil tank leak testing methods.

      We discuss how to find buried oil tanks, how to remove or abandon oil tanks and how to recognize evidence that there was a previous oil tank at a property even if the oil tank may have been removed (or perhaps left buried in place). We discuss what to do if an oil tank has already been removed or abandoned.

      We provide links to every U.S. state regulatory agency concerned with oil and other storage tanks and to regulatory agencies in Canada and other countries. Environmental damage from oil leaks, oil spill cleanup, are also discussed.

      We discuss oil spill cleanup, oil spill and odor remediation, and bioremediation, for fuel oil or heating oil. LP Gas tanks are also addressed. Home heating oil tank leak and environmental contamination risks are important concerns for building owners and home buyers as major cleanup and tank replacement costs can be involved.
    • Ozone Odors & Ozone "deodorizers": The Use of Ozone Generators Indoors for Control of Odors and Mold Removal in Buildings: A Summary of Hazards and False Claims. Ozone is widely promoted by ozone generating equipment companies and cleaning services for use in indoor building environments to deodorize, disinfect, "kill" mold, and for "general health". Ozone generators are also promoted for use to reduce the level of airborne particles, pollen, animal dander, and allergens, ostensibly to improve indoor air quality for asthmatics and people with allergies.

      While there are some important uses of ozone (such as for medical disinfection under controlled conditions), in general this is an idea which ranges from bad to dangerous in the home.

      This article series explains the effects of using ozone in buildings for these purposes and warns consumers about misapplication of and health risks from ozone in buildings. Because at least some of these claims are based on marketing desire, not good science, and because ozone exposure can be both dangerous and ineffective indoors, we have collected some information and references on this topic.
    • Ozone generators: The Hazards of Ozone & Ozone Gas Generators. This article gives an overview of the hazards associated with use of ozone indoors as a "mold remedy" or as an "air purifier". Ozone is widely promoted by ozone generating equipment companies and cleaning services for use in indoor building environments to deodorize, disinfect, "kill" mold, and for "general health".
    • Ozone Toxicity & Ozone Gas Exposure Hazards This article discusses Ozone Toxicity in Buildings - A Summary of Hazards of Indoor Ozone, Ozone Generators, and Use of Ozone for Mold Remediation.

      While there are some important uses of ozone (such as for medical disinfection under controlled conditions), in general this is an idea which ranges from bad to dangerous in the home. This article explains the effects of using ozone in buildings for these purposes and warns consumers about misapplication of and health risks from ozone in buildings.

      Because at least some of these claims are based on marketing desire, not good science, and because ozone exposure can be both dangerous and ineffective indoors, we have collected some information and references on this topic.
    • Paint Failures & Odors: How to Diagnose, Correct, & Prevent Paint Failure on Buildings. Paint odors: solvents and other chemicals in building paints or coatings are often a source of odor or paint smell complaints, even where low-VOC paints are in use.
    • Pesticide Odors U.S. EPA advice on pesticides and possible pesticide contamination
    • Pet odors: from dogs, cats, or other pets, source identification, testing, removal, are discussed beginning at our article "Cat Dander: how to inspect and test a building for past or current presence of cats, cat hair, cat dander, and cat allergens"

      This article discusses methods to check a building for animal allergens (cat, dog, etc) using as an example, Cat Dander: how to inspect and test a building for past or current presence of cats, cat hair, cat dander, and cat allergens.

      Here are research articles, inspection and testing procedures, and contact information for expert services. We give in-depth information about indoor air quality problems: causes of respiratory illness, asthma, or other symptoms such as neurological or psychological problems, air quality investigation methods, and remediation procedures such as mold cleanup, handling toxic mold contamination, and building or mechanical system repairs.
    • Plastic odors: see Siding Odors below. This discussion also pertains to other vinyl or plastic materials used in buildings such as diagnosing odors from plastic trim, plastic or vinyl windows, window screens, doors, or similar materials.
    • PLASTIC CONTAINERS, TANKS, TYPES - plastic recycling codes, contaminants, and water storage concerns, including BPA Bisphenol-A, PET, etc.
    • Septic or Sewer Odors: Diagnosing and Curing Sewer Gas Smells and Septic Tank Odors. This sewer odor article series describes how to diagnose, find, and cure odors in buildings including septic or sewage or sewer gas smells or "gas odors" in buildings with a focus on homes with a private onsite septic tank but including tips for owners whose home is connected to a sewer system as well.

      Sewer gases are more than an obnoxious odor. Because sewer gas contains methane there is a risk of an explosion hazard. In addition some writers opine that there are possible health hazards from sewer gas exposure, such as a bacterial infection of the sinuses (which can occur due to any sinus irritation). Depending on the sewer gas source and other factors such as humidity and building and weather conditions, mold spores may also be present in sewer gases.
    • Septic or Sewer Odors: Wet Weather or Cold Weather Sewage or Septic Odors: Diagnosis and Repair Guide. This article discusses the diagnosis and correction of sewer gas or septic odors with focus on diagnosing odor sources and causes in cold weather. Some of the diagnostic steps pertain to all seasons.
    • Sewer Gas Odors from drains: Diagnosing Clogged Drains & Septic System Backups: Is it a blocked drain or the septic system? - A First Step for Homeowners.

      This article series explains how to investigate slow or blocked drains and septic system backups to distinguish between a probable septic system failure versus a probable blocked building drain. When a building drain is clogged or slow, or when there is a septic system backup, it's important to determine where the problem lies, since the repair steps can be quite different and costs can vary widely.
    • SULPHUR & SEWER GAS SMELL SOURCES list of sources of sulphyr & sewer gas odors in buildings
    • Siding Odors: Vinyl Siding Failures, Diagnosis, Repair, Proper Installation: Siding, window, screen, & other "plastic" odors: We've investigated a number of reports of strange odors in residential buildings that were ultimately traced to vinyl or plastic which was outgassing. we have observed this phenomenon with vinyl siding, plastic or vinyl window or door screens, and plastic or vinyl windows.

      A key diagnostic step was the observation that the odors were strongest when the material under investigation was exposed to sunlight or other sources of heat. [This article is under development, September 2007, and we welcome content suggestions or questions].
    • Home Buyer's Detailed Guide to Septic Systems - Buying a Home With a Septic Tank. This article discusses septic tank care and maintenance and addresses some causes and cures of septic odors indoors or outside.
    • URETHANE FOAM Deterioration, Outgassing
    • VINYL CHLORIDE HEALTH INFO - dioixin (carcinogen) and HCL (acid) hazards from vinyl building products such as siding, windows, trim, especially if these substances are burned, also during production, possibly during outgassing in or on homes
    • Water Odors: How to Identify Odors in Drinking Water. This article discusses how to identify, diagnose, and cure common odors that may be present in drinking water. We also discuss which of these odors may warn of unsanitary conditions.

  • Oil Storage Tanks - Petroleum tanks, underground tanks, and above ground tanks, also other fuel tanks
    • Oil Tanks - The Oil Storage Tank Information Website: Buried or Above Ground Oil Tank Inspection, Testing, Cleanup, Abandonment of Oil Tanks
    • Abandon a Buried Oil Tank, How To - Abandoning Commercial Underground Tanks, Russ Brauksieck, ASHI Tech. Journal, Vol.3 No.1 Spring 1993, P. 40-41 [Reprint]
    • Environmental Issues & Regulations for Oil Tanks, Registration, Abandonment, Leak Reporting
    • Abandonment-Heating Oil Tanks less than 2,001 gallons - New Jersey Guidance
    • Abandonment, Closure, or Removal of Heating Oil Tanks - New Jersey Guidance
    • Underground Storage of Flammable and Combustible Liquids - Tank Removal, Abandonment or Placing Temporarily Out of Service - New Jersey Guidance
    • Above Ground Oil Tanks: Visual Inspection of Oil Storage Tanks for evidence of leaks, damage, improper piping - photos and text
    • Above Ground Oil Tanks Checklist, an Oil Company's advice
    • Above Ground Tanks UL Standards, UL Tank Listing Standards, guidance for home owners, buyers, and inspectors
    • Buried Oil Tanks - Finding How to Find Buried Oil Tanks and "Nearly Hidden" and Leaky Oil Tanks - photos and text.
    • Buried Fuel tank - Advice - Buried FUEL Tank - GAS or OIL advice for home buyers, inspection report language
    • NewHome Inspection Report Language Library: Buried Oil Tanks, Basic home buyer advice - home inspection report language suggestions
    • NewHome Inspection Report Language Library: Visible Defects in Oil Tank Installations, Tanks, and Heating Oil Piping
    • NewHome Inspection Report Language Library: Gas Fuel Piping or Tank Faults Basic advice - home inspection report language suggestions
    • Home Inspection Report Language Library: Oil Tanks text file list © Oil and Other Storage Tank Leaks, Testing, Abandonment, Inspection - UST home inspection report language files - Reference List
    • Indoor Environment Website Indoor Building Environmental Hazard Detection, Testing, Repair, & Prevention - Main Web Page
    • Leaky Heating Oil Tanks - Advice for Home Owners or Buyers: caused of leaks in oil tanks, oil tank testing alternatives, what to do about leaky tanks: D.J. Friedman, ASHI Tech. Journal, Vol.2 No.1, Winter, 1992 p. 42-43 Illus
    • Leaky Oil Tank Piping at the oil storage tank filler or vent piping can be diagnosed and repaired
    • Leak or Failure Rates for Home Heating Oil Tanks
    • Legal Issues Regarding Buried Oil Storage Tanks K.S. Rea, Attorney, summary from ASHI Chapter Seminar.
    • Primer on Petroleum Bulk Storage Tanks & Petroleum Contamination of Property Paul H. Ciminello, ASHI Tech. Journal, Vol.3 No.1 Spring 1993, p 35-39
    • Petroleum Bulk Storage J. Sibblies, NY State DEC, Advice to Home Owners and Home Inspectors about Oil Storage Tanks - summary from ASHI Chapter Seminar.
    • Septic Tank inspection, testing, diagnosis, repair
    • Web Link Exchange: Contact Us to list your website or contact information for oil tank testing, tank corrosion research, oil industry experts

  • Pesticides Contaminate House [PDF], also see TERMITE SHIELDS vs TERMITICIDE.
  • Pollen Allergens: identification, advice including a pollen identification photo library
  • Rodent control issues, including dander, fecal, and urine contamination of buildings and building insulation are discussed at our "Mold Action Plan" page.
  • Pesticides U.S. EPA advice
  • US EPA Radon Zone Map

  • Radon: detection, correction, & prevention in buildings
    • Health Effects of Radon
    • Guide to Measuring Radon
    • Effects of Radon on Home Sales
    • How to Remove Indoor Radon
    • See Radon Enviro-Scare for a full discussion of the normal cycle of public fear that accompanies the discovery and publicity of various environmental hazards, including radon gas and see Enviro-Scare, the Cycle of Public Fear for our article about consumer environmental safety worry cycles that change over time.
    • For a Thorough Background in Radon Hazards, Radon Mitigation, & the History of Radon Concerns in the U.S. also see these articles reprinted/adapted/excerpted with permission from Solar Age Magazine - editor Steven Bliss.
      • "Radon's Threat Can Be Subdued", part 1 - William Turner, Terry Brennan, Solar Age Magazine Radon and its progeny are the slipperiest pollutants in the indoor environment, but there are simple ways to keep radon and its relations at bay.
      • "Radon's Threat Can Be Subdued", part 2 - what is radon, where does radon come from, how does radon get indoors, and why is radon a problem in buildings.
      • "Radon's Threat Can Be Subdued", part 3 - standards for airborne radon levels in buildings and recommended levels of radon for action, how radon is best detected, and radon action plan.
      • "Radon's Threat Can Be Subdued", part 4 - radon prevention advice for new construction, radon in well water - how it is removed, sources of information about radon gas and radon contamination.

      • "Defeating Radon" part 1- Terry Brennan, Bill Turner, Solar Age Magazine - How does radon get into buildings, how do I know if a building has a radon gas problem, how can I solve radon problems in existing homes, and what can I do to prevent radon from entering new homes. Part 1: where Radon comes from, how to diagnose radon
      • "Defeating Radon" part 2- Guide to keeping radon out of new houses - design details
      • "Defeating Radon" part 3- Key spots to seal, to stop radon gas leaks into buildings
      • "Defeating Radon" part 4- Data on radon levels in buildings before & after radon mitigation treatment
      • "Defeating Radon" part 5- Air filtering, testing after radon mitigation, where to buy radon tests
  • NewSTAIN DIAGNOSIS on BUILDING INTERIORS, how to diagnose stains on walls, floors, carpets, and how to determine the stain source
  • NewSOUND CONTROL in BUILDINGS - principles of sound transmission, soundproofing designs, materials, details

  • Septic Systems and Onsite Waste Disposal
  • GO TO The Septic Information Website The Septic System Information Website - Home Owners and Home Buyers Guide to Septic Systems, Septic Inspectors Guide, Septic Repair Guide, Septic Design: Extensive, Detailed Consumer and Industry Information on Septic System Inspection, Testing, Maintenance, Repairs, Alternative Designs for on-site waste disposal
    • Additives & Chemicals for Septic System Maintenance , Are they even needed? Are they even legal?
    • Alternative Onsite Wastewater Disposal (Septic System) Designs for Septic Systems - design engineers, consultants, products, books for special problem situations, difficult soils, old system repairs
    • Biomat Formation in the Septic System Drainfield Absorption System - what leads to drain field clogging and expensive drainfield repairs
    • Buyer's Guide to Septic Systems for home and other Building buyers
    • Capacity: Determining Needed Septic Capacity - Septic Tank Capacity vs. Usage: What size is required?
    • Capacity: Determining Needed Septic Capacity - Water Usage: Typical residential water usage for people, appliances, and activities.
    • Clearances Required - Well distance to Septic, Septic clearance from well, trees, lakes, streams, property boundary, etc.
    • CLOGGED DRAIN DIAGNOSIS & REPAIR - is the problem the septic system or the Building drain system?
    • Contaminants, Septic identifying water and soil contaminants produced by onsite waste disposal systems
    • Contamination in Buildings from Sewage and Septic backup: inspection, testing, remediation, & references
    • Dye Tests: how to perform a Septic Loading and Dye Test - a septic function test
    • Inspecting and Testing Septic Systems: How to inspect and test onsite waste disposal systems Book materials: Detailed step by step procedures for owners and septic inspectors; inspection safety, procedures, problems, clearances, reports
    • Inspecting Onsite Waste Disposal Systems Class Materials: Explaining Septic System Operation to Clients; Visual Inspection, Testing, Invasive Inspection , Evaluation, Reporting; Future Trends, Legislation
    • Septic Contaminants, identifying - what are the contaminants produced by septic systems and what can be done about them if they escape initial treatment?
    • Library, Septic Drawings © These are educational, not engineering drawings and are © protected. Sample engineering drawings and plans wanted for the website.
    • Pumping Septic Tanks: When, How, What to Watch For when pumping or cleaning septic tanks
    • Septic System Inspections, Diagnosis, Repair, & Maintenance:: Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, Septic System an online book, details of inspection and testing procedures.
    • Septic System Maintenance - Tank Pumping: When, How, What to Watch For
    • Septic System Maintenance - Additives & Chemicals, Are they even needed? Are they even legal?
    • Sewage and Septic backup contamination in Buildings: inspection, testing, remediation, & references to expert sources
    • Tank Size, calculating septic tank size required by occupants and anticipated usage
    • What is a Septic System An Engineer's View, provided by Lockwood Engineering, & Septic System FAQ's

  • Sewage and Septic backup contamination in buildings: inspection, testing, remediation, & references to expert sources- see these detailed articles beginning at SEWAGE BACKUP TEST & CLEANUP
  • SULPHUR & SEWER GAS SMELL SOURCES list of sources of sulphyr & sewer gas odors in buildings

  • Water Supply, Contamination Levels, Water Testing Procedures
    • Drinking Water testing, contamination, correction - all topics
    • Drinking Water Testing Advice for home buyers home owners home inspectors
    • Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters
    • Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid
    • General water testing and corrective measure advice: contact your local health department.
    • Interpreting Drinking Water Test Results
    • Correcting Contaminated or Unsatisfactory Water
    • Drinking Water Contamination and Pollution How to Detect, Test, Correct, and Prevent Well Water Contamination - US EPA - Groundwater
    • Drinking Water Contaminant Levels - Maximum Allowed
    • How to Reduce Lead Contamination in Drinking Water: how to test & correction lead in drinking water
    • Lead Contamination from Water Supply Lines/Entry Mains, Lead Testing & Correcting Contamination from - Lead Pipe Problems/Advice
    • When and How to Shock or Chlorinate a Well - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
    • Extreme Lead Poisoning Symptoms Suggested by Feb 2006 NY Times Article on Kosovo Roma Camps
    • Water and Waste Water Test Methods, US EPA
    • Water Requirements, Home & Outdoor Living
    • ATSDR: Nitrate/Nitrite Toxicity [Big, Slow-Loading File] U.S. Government ATSDR Science Corner - 2.5MB PDF
    • Water Supply & Drain Piping, wells, Pumps, Water Supply Equipment
    • WATER TESTS, CONTAMINANTS, TREATMENT - what tests should be performed on drinking water and what treatment methods are recommended to remove water contaminants?
    • Septic Systems Information Website, septic system maintenance, inspection, testing, repair, & alternatives, preventing septic system failure
    • Sewage or Septic contamination in buildings - Investigation, Testing and Remediation
    • SULPHUR & SEWER GAS SMELL SOURCES list of sources of sulphyr & sewer gas odors in buildings

  • WATER PUMP SAFETY - plastic water & other storage tanks, chemical safety, endocrine disruptors, carcinogens
  • World Trade Center Collapse Dust microscopic image library of World Trade Center Collapse WTC dust from September 11th catastrophe

  • Questions & Answers regarding this article

    Questions & answers about detecting, testing for, and removing environmental hazards found in or around buildings.

    Ask a Question or Search InspectAPedia

    HTML Comment Box is loading comments...

    Recommend / Share this Article            

    ...

    Technical Reviewers & References

    Google
    • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
    • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
    • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
    • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY - see detailed links at page left

  • U.S. Army Field Manual FM-8-285-Noxious_Chemicals discusses Ammonia, Carbon Monoxide, Hydrogen Sulfide, Oxides of Nitrogen, Hazards caused by fire
  • Gregory Brown, P.E., Eastern Environmental Engineering Services, Califon NJ, Tel: 908-832-5098, Email: gabrown48@comcast.net. Mr. Brown, a licensed professional engineer in New Jersey and Pennsylvania, provides environmental / compliance, investigation, and remediation services and is the contributor of ENVIRONMENTAL REGULATIONS, New Jersey - Update on New Jersey Environmental Regulations that impact real estate transactions.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Environmental Health & Investigation Bibliography - our technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Adkins and Adkins Dictionary of Roman Religion discusses Robigus, the Roman god of crop protection and the legendary progenitor of wheat rust fungus.
  • Kansas State University, department of plant pathology, extension plant pathology web page on wheat rust fungus: see http://www.oznet.ksu.edu/path-ext/factSheets/Wheat/Wheat%20Leaf%20Rust.asp
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • US EPA - Mold Remediation in Schools and Commercial Building [ copy on file as /sickhouse/EPA_Mold_Remediation_in_Schools.pdf ] - US EPA
  • US EPA - Una Breva Guia a Moho - Hongo [on file as /sickhouse/EPA_Moho_Guia_sp.pdf - - en Espanol

Allergies, Allergens, Allergy Testing in Buildings - References & Products

  • Air Conditioning System Blower Fans & Filters Cascading for Optimum Indoor Air Quality
  • Allergen Tests in Buildings advice about how to test, what to look for, in evaluating the level of dog, cat, or other animal allergens in a building
  • "IgG Food Allergy Testing by ELISA/EIA, What do they really tell us?" Sheryl B. Miller, MT (ASCP), PhD, Clinical Laboratory Director, Bastyr University Natural Health Clinic - ELISA testing accuracy: Here is an example of Miller's critique of ELISA http://www.betterhealthusa.com/public/282.cfm - Townsend Letter for Doctors and Patients
    The critique included in that article raises compelling questions about IgG testing assays, which prompts our interest in actually screening for the presence of high levels of particles that could carry allergens - dog dander or cat dander in the case at hand.
    http://www.tldp.com/issue/174/IgG%20Food%20Allergy.html contains similar criticism in another venue but interestingly by the same author, Sheryl Miller. Sheryl Miller, MT (ASCP), PhD, is an Immunologist and Associate Professor of Basic and Medical Sciences at Bastyr University in Bothell, Washington. She is also the Laboratory Director of the Bastyr Natural Health Clinic Laboratory.
  • Allergens: Testing for the level of exposure to animal allergens is discussed at http://www.animalhealthchannel.com/animalallergy/diagnosis.shtml (lab animal exposure study is interesting because it involves a higher exposure level in some cases
  • Allergens: WebMD discusses allergy tests for humans at webmd.com/allergies/allergy-tests
  • Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
  • Atlas of Mold Related Illness Symptoms & Complaints - long list of both documented, studied mold related illness, and complaints ascribed to mold contamination or allergens in buildings
  • Cat Dander: how to inspect and test a building for past or current presence of cats, cat hair, cat dander, and cat allergens
  • Clinical Atlas of Mold Toxicity - An Online Description of Toxic, Pathogenic, Allergenic Fungi, Fungal Diseases
  • Fiberglass Insulation Contains Mold© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?
  • Mold Action Guide detailed guide on finding, removing, and preventing indoor mold contamination
  • Odors, Odor Detection, Smells, & Gases how to find and identify sources of noxious or toxic odors and gases
  • Other environmental risks, Our much longer list: Asbestos, carbon monoxide, electromagnetic fields, etc.
  • Ozone: The Use of Ozone Indoors for Control of Odors and Mold Removal in Buildings: A Summary of Hazards and False Claims.
  • Pollen Allergens: identification, plant pollen and indoor air quality
  • Products to Reduce Mold & Allergy Problems to reduce indoor mold or allergen levels: air cleaners, air purifiers, dust mite covers, vacuum cleaners, crawl space vents
  • Recognizing Allergens: What various indoor allergens look like - identification photos to help identify pollen, dust mites, animal dander, toxic or allergenic mold - Common Mold and other Allergens, Irritants, Remedies & Advice
  • Rodent control issues, including dander, fecal, and urine contamination of Buildings and Building insulation are discussed at our
  • Sewage and Septic backup contamination in Buildings: inspection, testing, remediation, & references to expert sources
  • Action Guide: What to do about mold, mildew, and other indoor allergens
  • ...

Asbestos Hazard, Testing, Removal, References & Products

  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • ASBESTOS IDENTIFICATION IN BUILDINGS How to find and recognize asbestos in Buildings - visual inspection methods, list of common asbestos-containing materials
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • Asbestos in Good Condition
  • Asbestos in Good Condition
  • Asbestos in Your Home U.S. EPA, Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • Asbestos HVAC Ducts and Flues field identification photos and guide
  • Asbestos NESHAP Adequately Wet Guidance, EPA340/1-90-019, December 1990, U.S. ENVIRONMENTAL PROTECTION AGENCY, Office of Air Quality Planning and Standards, Stationary Source Compliance Division, Washington, DC 20460,original web source: http://www.epa.gov/region04/air/asbestos/awet.htm
  • Asbestos paper duct wrap
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print, text and images available at InspectAPedia.com).
  • Asbestos Transite Chimneys, Flues, & Pipes in Buildings
  • Asbestos under the microscope
  • Asbestos Vibration Dampers & Asbestos in the Air Handler
  • Ceiling tiles: How to recognize ceiling tiles that may contain asbestos
  • Examples of unusual uses of asbestos in buildings
  • Fiberglass: Indoor Air Quality Investigations: Health Concerns About Airborne Fiberglass: Fiberglass in Indoor Air from HVAC ducts, and Building Insulation
  • Enviro-Scare: Electric Power Lines, Electromagnetic Fields, Cancer Risk, & "Enviro-Scare" - The Normal Curve Cycle of Public Fear of Environmental Issues
  • Dust from the World Trade Center collapse following the 9/11/01 attack: the lower floors of this building contained spray-on fire-proofing asbestos materials.
  • Asbestos Information Links: Asbestos Detection, Testing, Recognition, Hazards, Field Photos, and Information Sources, including health-related links such as legal services and information about mesothelioma and other cancers.
  • "Handling Asbestos-Containing roofing material - an update", Carl Good, NRCA Associate Executive Director, Professional Roofing, February 1992, p. 38-43
  • EPA Guidance for Controlling Asbestos-Containing Materials in Buildings, NIAST, National Institute on Abatement Sciences & Technology, [republishing EPA public documents] 1985 ed., Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460

Fiberglass in Buildings: hazards, testing, cleanup, prevention: references & products

For more information about fiberglass as an indoor air quality concern see:

  • Asbestos: How to find and recognize asbestos in buildings - visual inspection methods, list of common asbestos-containing materials (Asbestos is not fiberglass and vice versa).
  • BASEMENT MOLD includes examples of moldy fiberglass insulation found in basements
  • CRAWLSPACE MOLD includes additional examples of moldy fiberglass insulation found in crawl spaces
  • Duct System Defects
  • Fiberglass in Indoor Air, HVAC ducts, and Building Insulation, Indoor Air Quality Investigations, building insulation and HVAC duct work insulation hazards
  • FIBERGLASS HAZARDS
  • Fiberglass Particle Identification in the Fiberglass Test Laboratory
  • Fiberglass References - Government Agencies & Authorities list of public documents on fiberglass
  • Goodman Gray Flex Duct Deterioration and Failures
  • INSULATION INSPECTION & IMPROVEMENT
  • Insulation Identification Photographs - Fiberglass insulation photos, yellow, pink, green, white fiberglass identification in building attics, walls, ducts, other locations
  • Insulation Identification Photographs - Cellulose insulation photos, Mineral wool insulation photos, rock wool insulation photos, cotton insulation photos, balsam wool insulation photos
  • Insulation Identification Photographs - Vermiculite insulation photos
  • Lab Identification of Fiberglass photographs and text assist in laboratory identification of fiberglass fibers and fragments in air, dust, or material samples in the laboratory using forensic microscopic techniques.
  • Mold in Fiberglass building insulation, when, why, and how fiberglass becomes a reservoir of problem mold in buildings.
  • AIR FILTERS, OPTIMUM INDOOR
  • Owens Corning Flex Duct Deterioration and Failures
  • World Trade Center Dust Particle Identification
  • Fiberglass carcinogenicity: "Glass Wool Fibers Expert Panel Report, Part B - Recommendation for Listing Status for Glass Wool Fibers and Scientific Justification for the Recommendation", The Report on Carcinogens (RoC) expert panel for glass wool fibers exposures met at the Sheraton Chapel Hill Hotel, Chapel Hill, North Carolina on June 9-10, 2009, to peer review the draft background document on glass wool fibers exposures and make a recommendation for listing status in the 12th Edition of the RoC. The National Institute of Environmental Health Sciences is one of the National Institutes of Health within the U.S. Department of Health and Human Services. The National Toxicology Program is headquartered on the NIEHS campus in Research Triangle Park, NC. The National Institute of Environmental Health Sciences is one of the National Institutes of Health within the U.S. Department of Health and Human Services. The National Toxicology Program is headquartered on the NIEHS campus in Research Triangle Park, NC.
    Following a discussion of the body of knowledge, the expert panel reviewed the RoC listing criteria and made its recommendation. The expert panel recommended by a vote of 8 yes/0 no that glass wool fibers, with the exception of special fibers of concern (characterized physically below), should not be classified either as known to be a human carcinogen or reasonably anticipated to be a human carcinogen. The expert panel also recommended by a vote of 7 yes/0 no/1 abstention, based on sufficient evidence of carcinogenicity in well-conducted animal inhalation studies, that special-purpose glass fibers with the physical characteristics as follows longer, thinner, less soluble fibers (for 1 example, > 15 μm length with a kdis of < 100 ng/cm2/h) are reasonably anticipated to be a human carcinogen for the listing status in the RoC. The major considerations discussed that led the panel to its recommendation include the observations of tumors in multiple species of animals (rats and hamsters). Both inhalation and intraperitoneal routes of exposure produced tumors, although inhalation was considered more relevant for humans.
  • Fiberglass insulation mold: occurrence of mold contamination in fiberglass insulation can be impossible to see with the naked eye, but can be significant
  • World Health Organization International Agency for Research on Cancer - IARC Monographs on the Evaluation of Carcinogenic Risks to Humans - VOL 81 Man-Made Vitreous Fibers, 2002, IARCPress, Lyon France, pi-ii-cover-isbn.qxd 06/12/02 14:15 Page i - World Health Organization, 1/21/1998. - Fiberglass insulation is an example of what IARC refers to as man made vitreous fiber - inorganic fibers made primarily from glass, rock, minerals, slag, and processed inorganic oxides. This article provides enormous detail about fiberglass and other vitreous fibers, and includes fiberglass exposure data.
  • http://monographs.iarc.fr/ENG/Monographs/vol81/mono81.pdf - the article (large PDF over 6MB)
    http://monographs.iarc.fr/ENG/Monographs/vol81/mono81-6A.pdf - article details
    http://monographs.iarc.fr/ENG/Monographs/vol81/mono81-6C.pdf - studies of cancer in experimental animals in re vitreous fibers such as fiberglass;
    http://monographs.iarc.fr/ENG/Monographs/vol81/mono81-6E.pdf - summary of data reported & evaluation
    http://monographs.iarc.fr/ENG/Monographs/vol81/mono81-6F.pdf for the article references
    To search the IARC monographs on various environmental concerns and carcinogens, use http://monographs.iarc.fr/ENG/Monographs/PDFs/index.php
  • ...

Gases: Toxic gases, indoor exposure levels, testing, identification

  • A Toxic Gas Testing Plan: A Gas Sampling Plan for Residential and Commercial Buildings lists some of the toxic indoor gases for which we test, depending on the building complaint and building conditions
  • CCSP, 2008: Analyses of the effects of global change on human health and welfare and human systems. A Report by the U.S. Climate Change Science Program and the Subcommittee on Global Change Research. [Gamble, J.L. (ed.), K.L. Ebi, F.G. Sussman, T.J. Wilbanks, (Authors)]. U.S. Environmental Protection Agency, Washington, DC, USA. Web search 08/28/2010, original source: http://nepis.epa.gov/
  • Gas Exposure Hazard Levels: for Toxic Gas Exposure to Ammonia, Arsine, Arsenic, Bromine, Carbon Dioxide, Carbon Monoxide, Hydride, Ozone - allowable exposure levels and hazard levels
  • Carbon Dioxide Gas Toxicity hazard level, poisoning symptoms, & testing
  • Health Effects of Carbon Dioxide - see "National Advisory Committee for Acute Exposure Guideline Levels (AEGLs) for Hazardous Substances; Proposed AEGL Values, Federal Register Document", http://www.epa.gov/EPA-TOX/2002/February/Day-15/t3774.htm note that these are proposed guidelines
  • Carbon Dioxide CO2: Geologic Sequestration Health Effects: "Vulnerability Evaluation Framework for Geologic Sequestration of Carbon Dioxide [on file as /hazmat/CO2_EPA_VEF-Tech_Doc_072408.pdf ] - ", US EPA, EPA430-R-08-009, July 2008, web search August 2010,original source: http://www.epa.gov/climatechange/emissions/downloads/VEF-Technical_Document_072408.pdf
  • Carbon Dioxide CO2: Geologic Sequestration, U.S EPA, web search 08/28/2010, original source:
    http://www.epa.gov/climatechange/emissions/co2_gs_tech.html
    • GTSP, 2006: Carbon Dioxide Capture and Geologic Storage: A Core Element of a A Global
      Energy Technology Strategy to Address Climate Change (PDF, 37 pp., 6.05 MB, About PDF).
      April 2006, JJ Dooley et al. Global Energy Technology Strategy Program (GSTP)
    • IPCC, 2005: Special Report on Carbon Dioxide Capture and Storage, Special Report of the
      Intergovernmental Panel on Climate Change [Metz, Bert, Davidson, Ogunlade,
      de Coninck, Heleen, Loos, Manuela, and Meyer, Leo (Eds.)]. Cambridge University Press, The
      Edinburgh Building Shaftesbury Road, Cambridge CB2 2RU England
  • Carbon Monoxide Gas Toxicity hazard levels, poisoning symptoms, & testing
  • Fluorine, Its Compounds, and Air Pollution,: a Bibliography with Abstracts, US Environmental Protection Agency, Office of Air Quality Planning and Standards, Research Triangle Park, North Carolina 27711, December 1976. Web search 08/28/2010, original source: http://nepis.epa.gov.
    NOTE: because the EPA's original source of this document in PDF format is damaged we have created a text image file, converted to a new PDF for readability.
  • Formaldehyde: US EPA. UFFI (Urea Formaldehyde Foam Insulation) was previously considered a hazard (formaldehyde outgassing). Subsequent research virtually closed concern regarding this material; however formaldehyde appears to remain a health concern for sensitive individuals.
  • Greenhouse Gas Overview: Carbon Dioxide: U.S. EPA, web search 08/28/2010, original source:
    http://www.epa.gov/climatechange/emissions/co2.html
  • Nitrogen Oxides: Air Quality Criteria for Oxides of Nitrogen, Vol III of III, US EPA, EPA600/8-91/049cF, August 1993, web search 08/28/2010, original source: http://nepis.epa.gov [Large PDF 25MB]
    Key chapters in this document evaluate the latest scientific data on (a) health effects of NOx measured ill laboratory animals and exposed human populatIOns and (b) effects of NOx on agricultural crops, forests, and ecosystems, as well as (c) NOx effects on visibility and nonbiological materials. Other chapters describe the nature, sources, distribution, measurement, and concentratiOns of NOx m the environment These chapters were prepared and peer reviwed by experts from various state and Federal government offices, academia, and private industry for use by EPA to support decision makIng regarding potentIal risks to public health and the enVIronment Although the document IS not intended to be an exhaustIve literature reVIew, It IS intended to cover all the pertinent literature through early 1993
  • Ozone Warnings - New Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Sampling for gases in air such as VOC's, MVOC's, toxic chemicals, and combustion products.
    Unfortunately no single test or tool can detect all possible building contaminants. We use methods and equipment which can test for common contaminants. If the identity of a specific contaminant is known in advance we can also test for a very large number of specific contaminant gases in buildings.
    We use gas sampling equipment provided by the two most reliable companies in the world, Draeger-Safety's detector-tubes and Drager accuro� bellows pump, the Gastec� cylinder pump and detector-tube system produced by Gastec or Sensidyne, and we also use Sensidyne's Gilian air pump. For broad screening for combustibles and a number of other toxic gases and for leak tracing we also use Amprobe's Tif8850. All of these instruments, their applications, and sensitivities (minimum detectable limits) for specific gases are described in our Gas Sampling Plan online document.
  • Sulfur dioxide & other Oxides: Air Quality Criteria for Particulate Matter and Sulfur Oxides, Vol. III, US EPA, Environmental Criteria and Assessment Office, Research Triangle Park NC 27711, Dec. 1982, EPA-600/8/2-029c. Web search 08/26/2010, original source: http://nepis.epa.gov [large PDF]
  • Radon Gas U.S. EPA Radon level maps, web search 2005, original source: http://www.epa.gov/iaq/radon/zonemap/zmapp33.htm
  • "Table Z-1 Limits for Air Contaminants, 1910.1000 Table Z-1" OSHA standard for air contaminant limits (http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=STANDARDS&p_id=9992) - includes for CO2, Carbon dioxide.........| CAS No. 124-38-9 | 5000 ppm | 9000 mg/m3 limits for carbon dioxide as an air contaminant.
  • Toxic Gas Exposure Hazards and Test Protocols including links to our toxic gas exposure screening and gas testing protocols.
  • ...

Mold Contamination Testing, Cleanup, Prevention: references & products

  • GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminantsThe Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
  • Aerobiology, Building Science, Microscopy, & Laboratory References, an extensive technical bibliography
  • Allergens: what they look like in buildings
  • Associations: Sick House, Sick Building, SBS - Air Quality, Government, Private Associations and Information Resources
  • Atlas of Clinical Fungi, 2nd Ed., GS deHoog, J Guarro, J Gene, & MJ Figueras, Centraalbureau voor Schimmelcultures, Universitat Rovira I Virgili, 2000, ISBN 90-70351-43-9 (you can buy this book at Amazon)
  • Atlas of Mold Related Illness: Index of Symptoms and health, physical, neurological, psychological, and other complaint which people suspect may be mold or building-related.
  • Atlas of Indoor Mold, Online Clinical Mold Atlas, Toxins, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • Black Mold that is Harmless Photos of recognizable, usually harmless black mold on wood, bluestain, ceratocystis, ophistoma
  • Building Floods: quick steps after a building flood or plumbing leak can prevent costly mold contamination
  • Classes of Mold: what types of cosmetic, allergenic, or toxic mold are a problem? Can mold be cleaned-up successfully?
  • Clinical Mold References - Detailed bibliography of mold reference texts
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • "Disease Prevention Program for Certain Vegetable Crops," David B. Langston, Jr., Extension Plant Pathologist - Vegetables, University of Georgia (PDF document) original source: www.reeis.usda.gov/web/crisprojectpages/209797.html
  • "Disease Prevention in Home Vegetable Gardens," Patricia Donald, Department of Plant Microbiology and Pathology, Lewis Jett
    Department of Horticulture, University of Missouri Extension - extension.missouri.edu/publications/DisplayPub.aspx?P=G6202
  • "Management of Powdery Mildew, Leveillula taurica, in Greenhouse Peppers," Ministry of Agriculture and Lands, British Columbia - Original source: www.agf.gov.bc.ca/cropprot/peppermildew.htm
  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Fiberglass: Mold in Fiberglass Insulation© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation - DJF
  • Fifth Kingdom, Bryce Kendrick, ISBN13: 9781585100224, is available from the InspectAPedia online bookstore - we recommend the CD-ROM version of this book. This 3rd/edition is a compact but comprehensive encyclopedia of all things mycological. Every aspect of the fungi, from aflatoxin to zppspores, with an accessible blend of verve and wit. The 24 chapters are filled with up-to-date information of classification, yeast, lichens, spore dispersal, allergies, ecology, genetics, plant pathology, predatory fungi, biological control, mutualistic symbioses with animals and plants, fungi as food, food spoilage and mycotoxins.
  • Fungi, Identifying Filamentous, A Clinical Laboratory Handbook, Guy St-Germain, Richard Summerbell, Star Publishing, 1996, ISBN 0-89863-177-7 (English) (buy at Amazon)
  • Looking for Mold Procedure: what mold is often found where in buildings - simple technical presentation
  • Meruliporia: the house eating fungus or "poria"
  • Mold Action Guide: Step-by-Step Instructions, What to do about mold, mildew, and other indoor allergens
  • MOLD APPEARANCE - WHAT MOLD LOOKS LIKE Photos of what mold looks like in buildings
  • MOLD APPEARANCE - STUFF THAT IS NOT MOLD Photos of NOT-mold material that is sometimes mistaken for mold
  • MOLD ATLAS & PARTICLES INDEX, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • MOLD BY MICROSCOPE Mold under the microscope - photo identification of the most common indoor molds found in buildings
  • Mold FAQs Answers to Most Questions about Indoor Mold, Mold Related Illness, Mold Cleanup, Mold Prevention
  • US EPA: Mold Remediation in Schools and Commercial Building [ copy on file as /sickhouse/EPA_Mold_Remediation_in_Schools.pdf ] - US EPA
  • Mold spores in the Home - a Photo ID Library for detection and identification of mold allergens
  • Mold Test Kits - How to Collect and Send Your Own Mold Sample to our mold testing lab or to any mold lab you wish
  • Most Common Indoor Molds Found in Buildings, A Table of
  • Mycology, Fundamentals of Diagnostic, Fran Fisher, Norma B. Cook, W.B. Saunders Co. 1998, ISBN 0-7216-5006-6 (buy this book at Amazon)
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Rot concerns in buildings-some building mold such as Meruliporia incrassata "Poria" risks serious rot and hidden structural damage
  • US EPA: Una Breva Guia a Moho - Hongo [on file as /sickhouse/EPA_Moho_Guia_sp.pdf - - en Espanol

OTHER IAQ ISSUES: How To Find and Address Other Indoor Air or Indoor Environment Contaminants Besides Mold

Mold or allergens may not be the only or even the main indoor environmental contaminant. Don't let media attention to mold cause so much enviro-scare fear that other, possibly more urgent hazards go un-addressed.

  • Fiberglass building insulation and HVAC duct work insulation hazards
  • Sewage and Septic backup contamination in buildings: inspection, testing, remediation, & references to expert sources
  • Other environmental risks: Asbestos, carbon monoxide, electromagnetic fields, environmental illness, fiberglass, MCS - multiple chemical sensitivity, toxic gases, etc
  • Indoor Gas Sampling Plan for Residential Buildings lists a number of toxic indoor gases which we test for, depending on the building complaint and building conditions
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Pet control - if you can't say goodbye to your bird, cat, dog, guinea pig, hamster, tropical fish, then limit the areas they occupy and limit the airflow from that area to sleeping or other areas of the building, use allergenic bedding, eliminate wall-to-wall carpeting, improve housecleaning including use of a HEPA-rated vacuum cleaner. For more details see our article Dog, Cat, and Other Animal Dander - Information for Asthmatics and Indoor Air Quality
  • Rodents, Mice, Squirrel Control - I find high levels of mouse and rodent dander, fecal dust, and urine-contaminated dust in some buildings, and high levels of these materials in building insulation in those locations. If you have a mouse problem, particularly if mice and their waste (fecals or urine) are contaminating the building HVAC or building insulation, may need both steps to clean up or remove infected materials and steps to stop an ongoing rodent problem. If squirrels are a problem, the cleanup needs to include closing off entry openings into the building. Get some help from a licensed pest control expert.

Paint & Fiber Forensic Analysis, Diagnosis, Conservation

  • Analysis of Modern Paints, Thomas J.S. Learner, Research in Conservation, 2004 ISBN 0-89236-779-2
    [Chemistry of modern paints, overview of analytical methods, pyrolysis-gas chromatography signatures of basic modern paints and their constituents, Fourier transform infrared spectroscopy for paint analysis, direct temperature-resolved mass spectrometry, and analysis in practice - technical reference useful for forensic paint science, focused on art works. One of our most useful texts in forensic investigation of paint failures and paint problem diagnosis - for building investigators as well as art conservators. -DF]
    Although oil remains an important binding medium in artists' paints, today's synthetic resins are being used with increasing frequency. This was true during much of the twentieth century, when artists such as David Alfaro Siqueiros, Jackson Pollock, and Pablo Picasso used commercial or industrial paints based on synthetic resins. The growing popularity of synthetic resin materials carries important implications for the conservation, preservation, and treatment of modern art.
    This volume outlines the techniques that are currently employed to analyze the synthetic resins used in modern painting materials, such as pyrolysis-gas chromatography-mass spectrometry, Fourier Transform infrared spectroscopy, and direct temperature-resolved mass spectrometry. For each technique, results are given for standard samples of the principal classes of synthetic binding media, various pigments and extenders, tube paint formulations, and microscopic paint fragments taken from actual works of art.
    Primarily intended for conservation scientists, conservators, researchers, and students of conservation, this book will also be of interest to other museum professionals.
  • Art, Biology, and Conservation: Biodeterioration in Works of Art, Robert J. Koestler et als. Eds., Metropolitan Museum of Art, 2003, ISBN 1-58839-107-8
    Series of excellent research and advice articles on art work conservation of special use to conservators and also to building, artifact, and art forensic investigators. MOMA. - DF
    Despite the perception that artworks are timeless and unchanging, they are actually subject to biological attack from a variety of sources—from bacteria to fungi to insects. This groundbreaking volume, which publishes the proceedings of a conference held at The Metropolitan Museum of Art in 2002, explores how the development of these organisms can be arrested while preserving both the work of art and the health of the conservator.
    The richly illustrated text, containing the writings of over 40 scientists and conservators, is divided into sections on stone and mural paintings, paper, textiles, wood and archaeological materials, treatment and prevention, and special topics. The artworks and cultural properties discussed include, among many others, Paleolithic cave paintings, Tiffany drawings, huts built by early Antarctic explorers, and a collection of toothbrushes taken from Auschwitz victims. -- Robert J. Koestler is a research scientist at The Metropolitan Museum of Art; Victoria H. Koestler is a freelance writer and editor; A. Elena Charola is a freelance conservation scientist; and Fernando E. Nieto-Fernandez is a biologist at Old Westbury College, New York.
  • Cultural Heritage and Aerobiology, Methods and Measurement Techniques for Biodeterioration Monitoring, Paolo Mandrioli, Guilia Caneva, and Cristina Sabbioni, Eds., Kluwer Academic Publishers, 2003 ISBN 1-4020-1622-0
    This is a translated and revised edition of the original Italian version. This book is the first to give a general overview of the application of aerobiology (the science that studies the biological components of the atmosphere) to the conservation of our cultural heritage. Aerobiological monitoring makes it possible to estimate the risks of degradation of artefacts of historical or artistic importance by airborne microorganisms (airborne spores and vegetative structures) according to the types of materials forming the artefacts, to the conditions of the microclimate and to the type of environmental pollution, thus enabling the planning of preventive or reparative intervention. Among the book's main features are: + Aspects of the biodeterioration of different materials (paper, wood, fabrics, parchment, leather, stone, glass, metals, plastic, etc.). + Methods for measuring environmental parameters, both physical (microclimatic) and chemical (pollutants). + Methods and techniques of aerobiological monitoring. + Specific problems concerning the different types of environments. Audience: The subject is thoroughly explored, thus supplying a useful tool to those who are in charge of the conservation of our cultural heritage (libraries, archives, museums, churches, hypogea, monuments, archaeological sites, etc.).
    See our book review of this reference.
  • Exterior Paint Problems on Historic Woodwork [Copy on file as /exterior/Preservation_Brief_10_ Exterior_Paint_Problems_on_Historic_Woodwork.pdf ] - , Kay D. Weeks and David W. Look, AIA, U.S. Department of the Interior, National Parks Service Preservation Brief No. 10. Web search 02/01/2011, original source: http://www.nps.gov/hps/tps/briefs/brief10.htm
  • Microscopy of Textile Fibres (Microscopy Handbooks, 32), P H Greaves, Garland Science; 1 edition (January 1, 1995), ISBN-10: 1872748244, ISBN-13: 978-1872748245
    [We ordered our copy from the British publisher - now it's on Amazon.
    These 3 fiber books have been essential forensic lab references supplementing our McCrone Research courses on forensic microscopy; also of use to textile conservators. - DF
    An up-to-date practical guide to the properties and characteristics of textile fibres, with clear advice on sampling, specimen preparation and examination procedures.
  • Microscopy of Animal Textile Fibres, Alex Blakey Wildm, 1954
    Hard to obtain, useful for forensic microscopy - DF
  • Modern Paints Uncovered (Getty Conservation Institute Symposium Proceedings), Thomas Learner, Getty Publications (March 1, 2008),ISBN-10: 089236906X, ISBN-13: 978-0892369065
    Over the past seventy years, a staggering array of new pigments and binders has been developed and used in the production of paint, and twentieth-century artists readily applied these materials to their canvases. Paints intended for houses, boats, cars, and other industrial applications frequently turn up in modern art collections, posing new challenges for paintings conservators.
    This volume presents the papers and posters from "Modern Paints Uncovered," a symposium organized by the Getty Conservation Institute, Tate, and the National Gallery of Art and held at Tate Modern, London, in May 2006. Professionals from around the world shared the results of research on paints that have been available to artists since 1930--the date that synthetic materials began to significantly impact the paint industry.
    Modern Paints Uncovered showcases the varied strands of cutting-edge research into the conservation of contemporary painted surfaces. These include paint properties and surface characteristics, analysis and identification
  • Of Microbes and Art: The Role of Microbial Communities in the Degradation and Protection of Cultural Heritage, Kindle Edition, Springer; 1 edition (June 30, 2000), ASIN: B000VHV4FC
  • Paint Handbook: testing, selection, application, troubleshooting, surface preparation, etc., Guy E. Weismantel, Ed., McGraw Hill Book Company, 1981
    [Excellent but a bit obsolete paint theory and practice, also a bit light on field investigation methods, out of print, available used. Very useful reference for paint testing, selection, and paint failure diagnosis - focus on non-artistic use of paints such as on buildings, roofs, marine coatings. -DF]
    How to select and apply the right paint or coating for any surface. The first major reference to help you choose the correct paint or other finish to do the job best on a particular surface exposed to a particular environment. Experts in the field give full advice on testing surface preparation, application, corrosion prevention, and troubleshooting. The handbook covers wood, metal, composites, and masonry, as well as marine applications and roof coatings. A ``must'' working tool for contractors, architects, engineers, specification writers, and paint dealers
  • Paint Magic, Jocasta Innes, Frances Lincoln; 4th edition (August 17, 2006), ISBN-10: 071122272X, ISBN-13: 978-0711222724 - Paint advice for home decoration, including painting techniques such as antiquing, bambooing, bleaching, color washing, combing, decorative painting, dragging, dyeing, gliding, graining, japanning, lacquering, lining, marbling, porphyry, rag-rolling, sponging, staining, stencilling, stippling, tortoiseshelling, trompe l'oeil, and vinegar painting - DF
  • Paint and Surface Coatings, Theory and Practice - [purchase at Amazon.com], R. Lambourne & T.A. Strivens, Ed., Woodhead Publishing Ltd., William Andrew Publishing, 1999 ISBN 1-85573-348 X & 1-884207-73-1
    [ This is perhaps the leading reference on modern paints and coatings, but is a difficult text to obtain, and is a bit short on field investigation methods. Encyclopedic reference on the composition, production, properties, use, and testing of paints and coatings - DF]
    Provides a comprehensive reference source for all those in the paint industry, paint manufacturers and raw materials suppliers, undergraduate and postgraduate students, and industrial paint users.

  • Plant Biology for Cultural Heritage: Biodeterioration and Conservation, Giulia Caneva, Maria Pia Nugari, Ornella Salvadori, Getty Publications (January 15, 2009), ISBN-10: 0892369396, ISBN-13: 978-0892369393
  • Quality Assessment of Textiles, Karl Marshall, Kindle Edition, Springer; 2nd edition (October 31, 1993, ASIN: B00193F3BI
    The damage which can occur in certain fibrous raw materials or during the production and storage of textiles is expertly described in this book by Karl Mahall. He particularly shows how to find concealed textile defects by using microscopic analysis. The examples represent typical cases that the author encountered during forty years of experience in the industry. Well-illustrated with impressive photographs, they invite you to follow each step and learn to apply the same methodology in practice. This book is especially useful as a manual for both chemical and textile engineers and quality engineers. It is also a useful reference for others in the textile industry in general.
  • Seeing Through Paintings, Physical Examination in Art Historical Studies, Andrea Kirsh, Rustin S. Levenson, Materials in Fine Arts, 2000 ISBN 99-051835 [ forensic science, technical reference, focused on art works - DF]
    One of the best texts available for forensic investigation of the history, authenticity, and condition of paintings - DF
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF - ** Particuarly useful text **
  • Understanding Ventilation, John Bower, The Healthy House Institute, ISBN 0-9637156-5-8, 1995 [General building science-DF - ** Particularly useful text. Mr. Bower has retired from the field but his book continues to be important]
  • Dampness in Buildings, Diagnosis, Treatment, Instruments, T.A. Oxley & E.G. Gobert, ISBN 0-408-01463-6, Butterworths, 1983-1987 [General building science-DF]
  • "Moisture Control in Buildings: Putting Building Science in Green Building," Alex Wilson, Environmental Building News, Vol. 12. No. 5. [Good tutorial, "Moisture 101" outlining the physics of moisture movement in buildings and a good but incomplete list of general suggestions for moisture control - inadequate attention given to exterior conditions such as roof and surface drainage defects which are among the most-common sources of building moisture and water entry.--DJF]
  • "Paint Failure Problems and Their Cure," Daniel L. Cassens and William C. Feist, National Forest Products Laboratory, online via Purdue University, http://www.ces.purdue.edu/extmedia/NCR/NCR-133.html
  • Why House Paint Fails [on file as /exterior/Why_House_Paint_Fails_FPL1.pdf ] - , Mark Knaebe, US FPL, web search August 2010, original source: http://www.fpl.fs.fed.us/documnts/finlines/knaeb95a.pdf
  • Why Paint Jobs Fail [on file as /exterior/Why_Paint_Fails_Bennett.pdf ] - , web search, August 2010, original source: http://www.bennette.com/pdf/whyfail.pdf, four pages describing alligatoring, bleeding, blistering, etc. Bennette Corporation, P.O. Box 9088, Hampton, VA 23670, Phone: 757-838-7777, Toll Free: 800-869-2929 Fax: 757-827-0529, Email: info@bennette.com, Website: www.bennette.com quoting:
    Bennette Paint Manufacturing Company, Inc. is a Virginia corporation which was founded in Newport News, Virginia in 1966 by James P. Bennette, Sr. In 1984, Mr Bennette sold the company to his employees through an Employee Stock Ownership Plan (ESOP). Today the company has a modern manufacturing plant, research laboratory, central warehouse and general offices located at 401 Industry Drive, Hampton, Virginia. From these facilities the company is able to supply quality paints and coatings through its company owned distribution and service centers and authorized dealers located in Virginia, North Carolina and South Carolina. Bennette Paint Manufacturing Company, Inc. also owns and operates Bennette Equipment Company which specializes in the sale, service, and rental of paint spraying and pressure cleaning equipment.
  • Supplemental Guidelines for Removing Paint From Interior and Exterior Wood Surfaces [on file as "/exterior/Paint_Removal_USGSA.pdf ] - , US General Services Administration, Historical Preservation Technical Procedures, 06400-02, web search August 2010, original source: //w3.gsa.gov/web/p/Hptp.nsf/0/40aff5a115b6a9e5852565c50054b4f4?OpenDocument
  • "Common Paint Problems," http://www.parkerpaint.com/Common%20Paint%20Problems.html illustrates common paint failures - though their images and text appear to have been stolen from PPG - see http://www.ppg.com/getpaint/etraining/solver/exterior.html which catalogs paint failures and causes
  • "Paint problem solver" from Lowes, http://www.lowes.com/lowes/lkn?action=howTo&p=Improve/PntPrbSlv.html&rn=RightNavFiles/no.html
  • "Mill Glaze: Myth or Reality," R. Sam Williams, Mark Knaebe, US FPL, original source: fpl.fs.fed.us/documnts/finlines/willi01a.pdf
  • http://www.paintlab.com/failure.html is a lab offering paint chip failure analysis
  • PPG Exterior Failures http://www.ppg.com/getpaint/etraining/solver/exterior.html
  • "Peeling Back Paint Layers For a Glimpse Into the Past," James Barron, The New York Times, 25 Feb 2010, p. A26
  • "Staining and Microbiological Infestation of Acrylic Paintings on Hardboard", Ulrik Runeberg, Conservator (Dipl. Rest./M.A.), Museo de Arte Contemporáneo de Puerto Rico, San Juan Presented,April 2007 conference in Richmond Virginia, sponsored by the AIC (American Institute for Conservation), this paper discussed the staining and microbial infestation of acrylic paintings on hardboard. - private correspondence, ER <->DF 12 September 2006. The following quotation is from the paper's abstract:
    "Hardboard served as a common and popular support for many modern paintings that were carried out from the mid - 1920’s, and still is used occasionally in contemporary art. Many artists rejected hardboard as an inferior industrial construction material of low aesthetical value, whereas others considered the processed and compressed wood fiber boards to be a stable, light and economic alternative to solid wood panels and other rigid supports.
    "From the conservator’s critical point of view, the many disadvantages of this type of support include:  high acidity, hygroscope characteristics, tendency of ‘off-gassing’, (>tendency of) warping, occasional flaking of painting material in the case of tempered hardboard. The deterioration of paintings on hardboard depends on a number of factors including:  the quality of the hardboard, prevailing storage conditions, and the preparation of the support by the artist. While there are many paintings on hardboard that are in very good condition, this paper will focus on those paintings that are heavily deteriorated and damaged.
    "A very characteristic damage found on porous painting layers such as acrylic colour on hardboard, is the formation of stains. Generally, those stains are described without any differentiation as ‘fox-spots’. The examination of various paintings concerned led to the conclusion, that there exist different kinds of stains that need to be discriminated against each other, to ensure an appropriate conservation and restoration treatment.
    "This paper aims to characterize and differentiate the stains, and will provide preventive and practical treatment proposals for the conservation and restoration of affected paintings.  Questions such  as ‘What are the stains composed of?’ and ‘Which may be the causes?’ will be addressed.  Stains may consist of a variety of contents, such as: Ligneous residues, fungal infestation, bacterial activity, a combination of microbial and support induced discolouration [SID], a ‘symbiotic relation’ of ‘SID’ and fungal infestation, or the blooming of ingredients from the original painting materials. A range of microscopic analysis of the actual microbiological infestation of selected samples will be provided.  The paintings that were examined, sampled and treated, are part of the Puerto Rican heritage, and were all kept in excessive humid tropical conditions, before they entered the Conservation Department of the Museum of Contemporary Art in Puerto Rico.
    "Conservation treatment options of stained paintings on hardboard will be discussed.  A high level of acidity (caused from SID and/or micro-organisms) may require measures of reduction, disinfection and neutralization. Treatment methods that reduce the ligneous stains and residues of micro-organisms, and neutralize affected areas in painting layers include stain removal through the application of soaking compresses (poultices), and de-acidification through alkaline material.
    "Other aspects of deterioration, that do not have to do directly with the formation of stains, but also are typical for hardboard as painting support, will be mentioned briefly." - U.R.
  • ...

Sewage Contamination, Septic Backups, Bacterial & Mold Hazards: references, products

  • Safety: Septic System, Septic Tank, & Cesspool Safety Warnings for Septic Inspectors, Septic Pumpers, and Homeowners
  • Septic Contaminants, identifying - what are the Nitrogen contaminants produced by septic systems and what can be done about them if they escape initial treatment?
  • Septic Tank Pathogens in Sludge and Floating Scum: what makes up the contents of residential sewage
  • Measuring Septic Sludge & Scum Levels in Septic Tanks - Measuring the Level of Accumulated Solids, Sludge and Floating Scum in Treatment Tanks
  • Sewage and Septic Contamination in Residential Buildings - inspecting and testing for bacterial contamination after a sewage spill: consumer information and expert resources
  • Septic Flood Response when and what to do to a septic system after area flooding

  • The Septic Information Website - Inspecting, Designing, & Maintaining Residential Septic Systems
  • "Remediation of Sewage Contaminated Crawlspaces", Byjim Holland, CR, "Cleaning and Restoration," July 1999, pp 22-24, original source: restcon.com/links/articles/Remediating%20Contaminated%20Crawlspaces.pdf
  • Escherichia coli O157:H7- US CDC
  • Demistifying Ecoli - Federation of Ontario Cottagers
  • Microbiology home page - US EPA
  • Cost effective testing for blackwater contamination in buildings Aerotech Labs
  • Indicator organisms, testing for sewage contamination in buildings Aerotech Labs
  • SEPTIC BACKUP PREVENTION
  • SEPTIC BACKUP REPAIR
  • Septic Contaminants, identifying - what are the contaminants produced by septic systems and what can be done about them if they escape initial treatment?
  • Sewage and Septic Contamination in Residential Buildings - consumer information and expert resources (this web page)
  • Sewage Pathogens in Septic Tank Sludge and Floating Scum: what makes up the contents of residential sewage
  • The Septic Information Website - Inspecting, Designing, & Maintaining Residential Septic Systems
  • Septic System Flood Response - what to do when a septic system has been exposed to flood waters
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com