FREE Encyclopedia of Building & Environmental Construction, Diagnosis, Maintenance & Repair No ChatBot Pledge: The accuracy & trustworthiness of every InspectApedia article or Q&A is researched by human experts.
HVAC Manuals, Parts Lists, Wiring Diagrams Brands F - I
POST a QUESTION or COMMENT about where to find furnace or boiler installation and service or maintenance manuals and guides
Manuals, parts lists, wiring diagrams for HVAC equipment:
Free downloadable manuals for Air Conditioners, Boilers, Furnaces, Heat Pumps. Here we provide free downloadable copies of installation and service manuals for heating, heat pump, and air conditioning equipment, or contact information for the manufacturers who can provide that information for nearly all major brands of HVAC equipment.
We include links to contact information for each manufacturer or producer of these air conditioners, heat pumps, furnaces, boilers and related equipment, parts, and installation, repair, wiring diagrams, manuals.
We include immediate downloads of example installation & repair manuals and wiring diagrams for air conditioners, heat pumps, and heating equipment from a variety of manufacturers as well as contact information to obtain the exact manual or wiring diagram for your unit.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
Free Furnace, Heat Pump, Air Conditioner Installation & Service Manuals, Wiring Diagrams, Parts Lists
Below we provide HVAC manufacturer contact information and direct links to free downloadable installation, service, and users manuals, focusing on hard-to-find manuals for older models or discontinued equipment. We also provide links to the manufacturer's current model lists and literature.
Note: for page loading speed, this index to HVAC manuals is spread across several pages, but all of the individual companies are listed in
this HVAC MANUALS MASTER INDEX
Heil Quacker HVAC, purchased by Toronto Company Inter City Gas, Toronto, from Whirlpool, thence using the Tempstarbrand. HVAC operations now owned by International Comfort Products. ICP was purchased in turn by United Technologies.
Homer Furnace Company, Coldwater Michigan, with offices across the U.S., produced the Homer Pipeless Furnacee, [Ilustrated above]
Home Furnance Corporation purchased by Lear-Siegler Inc. who became Miller Heating & Air Conditioning in 1986 after being acquired by Nortek Inc. Listed as Nordyne. See Intertherm.
International Heater, originally founded as International Oil Burner, St. Louis MO in 1919, purchased by Weil McLain 1965 as International Heating & Air Conditioning division in 1973-1974. Weil McLlain purchased by Marley Company.
INTERTHERM HVAC purchased by Nordyne 1987. Since 1998 Intertherm Boilers or HVAC sold under White-Westinghouse brands Frigidaire, Gibson, Kelvinator, Philco, Tappan and as OEM for ThermalZone.
Note: for page loading speed this index to HVAC manuals is spread across several pages, but all of the individual companies are listed in
this HVAC MANUALS MASTER INDEX
Direct Links to Free Downloads of Heat Pump parts lists, wiring diagrams. Direct Links to Free Downloads of Boiler Manuals. Links to free copies of Lennox Equipment Installation, Service, & Owners Manuals for Lennox furnaces, Lennox heat pumps, Lennox Air Conditioners. Furnace & Boiler recalls, heating system safety notices.
Before paying for a furnace or boiler or air conditioner manual, see if it is already listed here or at the manufacturer's website. If you have trouble finding a mechanical system installation or service manual, Contact Us and we will research it for you at no charge.
Also see MANUALS for HEATING & A/C SYSTEM CONTROLS for a list of free downloadable PDF files of common heating system controls used on boilers, furnaces, heat pumps.
HVAC data tag decoding: For help in decoding air conditioner, boiler, furnace, heat pump, water heater data tags and determining the age, model, or specifications of that equipment, see
In those articles we provide documents with extensive equipment data tag decoding information, both free, and for purchase from other sources.
AtReferences or Citations we provide more contact information, links to current model list information, product specifications, and installation/operation manuals for each manufacturer.
Federal Boilers
Current Contact: Federal Corporation, 120 E Main St
Oklahoma City OK 73104
4 USA, Tel: 05.239.7301 Web: federalcorp.com
The Federal Boiler Company was founded on my father's birthday [DF] April 23, 1918 in Oklahoma City. Currently the company distributes a wide range of boilers and water heaters including products manufactured by most major brands such as Cemline, Hamilton Engieering, Laars, Lochinvar, Peerless, Rite Boilers, and supporting equipment such as pumps by Barnes, Burks, Taco and Little Giant, and heting controls by Honeywell, Johnson Controls, Honeywell, Maxitrol, etc.
According to the company's website (below),
Federal Corporation is a manufacturer representative and wholesale distributor serving Oklahoma, Texas, Arkansas and surrounding regions.
Federal Boiler Company History
Federal Boiler Co, Inc., Midland Park, Park, New Jersey - including gas boilers ca 1950. This Federal Boiler Company was later bought by and merged with the Easco Boiler Company.
This Federal Boiler Company provided hot water heating system boilers as well as radiators and baseboard heating components.
Question: Manufacturer, Make, Model, Type, Serial# and Date of Manufacturer of the Federal Boiler
2020/10/14 Matt said:
Can you identify the Manufacturer, Make, Model, Type, Serial# and Date of Manufacturer of the Federal Boiler identified by the pic of the attached tag.
Matt please try again: using the "add image" button you can post a .jpg .gif etc. image file. Most-likely, if your boiler's data tag contains the name "Federal Boiler Co." then it's the older New Jersey company that we cite above.
Fedders Air Conditioners - window air conditioners
Contact Fedders Corporation, Singapore 16 Raffles Quay #26-00, Hong Leong Building, Singapore 048581 China Website: www.fedders.com
Fedders Air Conditioning, a U.S air conditioner brand since 1896 when the company was founded by Theodore Fedders, sold central A/C in the U.S. until 1980.
The company, purchased by Airwell Group, retained the brand name Fedders as well as names listed below, currently owned by a Chinese company, acquired Emerson Quiet Kool in 1991.
The company currently sells window air conditioners branded as Airtemp, Climatrol, Emerson, Eubank, Fedders, Hunter, Koppel, Melcor, Polenz A MAC-10, Maytag (license agreement), Trion, Sun, air conditioning units
Ferguson HVAC Air Handlers, Air Conditioning, Manuals
Watch out: there are numerous HVAC companies using the name Ferguson incuding distributors and local HVAC service companies.
Contact: Ferguson Heating & Cooling, Website: https://heatingcooling.fergusonhvac.com/
Distributes Bosch, Goodman, Fujitsu, Mitsubisi, Trane Rheem, Ruud, and other HVAC equipment, varying by region in the U.S.
Website excerpt: Ferguson HVAC is a national distributor of residential and commercial heating & cooling equipment, parts and supplies.
Contact Firebird, Ballymakeera, County Cork, Ireland, distributed by Quincy Hydronic Technology Inc., 3560 Lafayette Rd.,Bldg. 2 Unit A., Portsmouth NH 03801 USA, Tel: 800-501-7697
Fitzgibbons Boiler Company
1932 Fitzgibbons Boiler advertisement shown above, appearing in American Architect & Architecture, cites Fitzgibbons steel boilers used to heat new U.S. Federal buildings including post offices and courthouses. (Ad for sale on eBay in 2023)
Fitzgibbons Boiler Company, 876 Seventh Avenue, New York NY with boiler works in Oswego NY
Example Federal Boiler model number: TC-125 Gas boiler.
Flame-Master Gas Furnaces - a little information
Watch out: Names and who is using them can change over time: for example the name "Flamemaster" appears on other products such as sealants, coatings and packaging produced by Flamemaster in Pacoima California, US - not a heting equipment manufacturer.
The product line Flamemaster gas furnaces shared product designs with ClimateMater. ClimateMaster continues in business (in 2015) as a manufactuer of geothermal heat pump systems.
Here is what we have found of the history of Flame Master furnaces and Flame-Master furnace manua availability.
Contact: Bow Valley Resource Services, Ltd., Flame Master Gas Furnaces, (previously a 1960's company named Hi-Tower) a Canadian firm in Calgary, Alberta, also previously filed for activcity in the U.S. in California, no longer active.
May have also produced model 394 & 396 Natural-Draft Flame-Master gas furnaces and gas furnaces sold under the brands of Bryant, Day & Night, and Payne Furnace brands. Estimated cessation 1986.
Watch out: some spoofing websites have gamed the search engines when you search for Flame-Master Furnace Manual and either load executable virus files or tell you they're giving you a Flame-Master Furnace manual but actually deliver a manual for a Kil 1825 Router. If a reader can share a Flame-Master furance manual with our other readers, contact us using the page-bottom CONTACT link. - Ed.
On 2020-02-25 - by (mod) - Flame Master furnace blower motor replacement
Roger
What motor is "burnt out" ?
- Oil burner motor?
- Blower fan motor?
In any case I'd bet a six-pack of Castle Danger beer that the motor on your Flame Master furnace is not unique but rather an off-the-shelf electric motor that can be replaced with a generic unit.
Pull the motor and take it to a local electrical or HVAC supplier. The only wrinkle might be if there's an unusual shaft length that needs to be matched.
On 2020-02-25 by Roger
I have a flame master furnace installed around 1986, the motor burnt out and cannot find a replacement, anybody know where we can order the motor?
McAuley, Jr., John A., THERMAL SHOCK to HEATING BOILERS [PDF], risks of thermal shock damage to heating equipment, contact Mr. McAuley at Brant Steel Products Limited 49 Craig Street Brantford Ontario N3R 7H8 Tel: 519-756-5700
Email: fabricate@brantsteel.com
Website: www.brantsteel.com
Contact Fleetline: Fleetline Hot Water Boilers, Brant Steel Products Limited 49 Craig Street Brantford Ontario N3R 7H8 Tel: 519-756-5700
Email: fabricate@brantsteel.com
Website: www.brantsteel.com
Brant Steel Products, the manufacturer of the FLEETLINE BOILER,
is part of the eKOCOMFORT group of manufacturers.
_
KOCOMFORT™ group of manufacturers
Question: How do I determine the efficiency of my 1995 Fleetline Oil Fired Boiler?
How do I determine the efficiency of my 1995 Fleetline oil fired boiler? - Duncan 11/21/12
Reply:
Duncan,
The heating service tech (not you) should do the following:
Clean the system completely, including boiler, flue vent connector, and if needed, chimney
Assure proper combustion air source
Adjust the system to factory spec: oil pressure, draft, burner nozzle, electrodes, etc.
THEN
the tech will measure the stack temperature at the breech, the CO2 level.
The combination of CO2 level and temperature allow anyone to read a chart of combustion efficiency of the unit in that condition.
Just looking up a spec somewhere tells you little about how your system is actually performing unless you take the steps above.
To read details about this procedure Search InspectApedia for
Oil Burner Tests & Adjustments: Measure & Set Oil Burner Smoke & CO2 Levels
Fraser Johnston Furnaces
Our Fraser Johnston Furnace Guide, aka Fraser Johnson Furnaces, has its own page now found at FRASER JOHNSTON HVAC
FP Industries Franks Piping Boilers
Founded in Eastern Canada in the 1950s, FP Industries, or previously Franks Piping Boilers, was a steel boiler manufacturer, later merged with Dettson Industries. The merged boiler manufactuer then marketed boilers under the Hydra boiler brand.
In 1983 Dettson released their Hydra III boiler under the FP or Frank’s Piping brand. Dettson Industries was, in turn, purchased by the Ouellet Group in 2010.
Lou, if you can post a photo (one per comment) of the FP Boiler data tag, and of the boiler and another of its logo that would be most helpful; I'm researching the history of FP Industries.
FRIEDRICH SERVICE MANUALModels MWM18Y3J / MRM18Y3J, MWM24Y3J / MRM24Y3J [PDF], retrieved 2017/04/02, original source: http://friedrich.gear.host/documents/dss/MM18YJ-MM24YJ.pdf
Contact Friedrich Air Conditioning, Window Air Conditioners, Ductless / Split System Air Conditioners, Hazardguard, Uni-Fit, WallMaster (through-wall air conditioners), portable air conditioners, dehumidifiers, PTAC units, Breze Units, and Vert-I-Pac Units:
Friedrich Corporation 10001 Reunion Place, Ste. 500 San Antonio, Texas 78216 USA (210) 546-0500 (800) 541-6645 Website: https://www.friedrich.com/contact-us
Friedrich Residential HVAC was acquired by ARCO in the early 1980s.
The company was re-named Friedrich Climate Master Inc. in 1985, selling water source heat pumps. Friedrich was dropped from the tradename in 1987.
Friedrich HVAC products evolved into Arcoaire. The Friedrich Air Conditioning name is still used on window units & mini splits after purchase of Zoneaire from ICP.
GAZCO STUDIO Conventional Flue MANUAL [PDF] (2008) For use in GB, IE (Great Britain and Eire) COVERING THE FOLLOWING MODEL:
Studio 1 conventional flue :
8700CFCHEC 8701CFCHEC
P8700CFCHEC P8701CFCHEC
GAZCO STUDIO 2 Balanced Flue MANUAL [PDF] (2015) For use in Australia covering these models: Natural Gas #8701BFLECAU & Propane Gas #P8701BFLECAU
STOVAX Studio Inset Convector Cassette MANUAL [PDF] For use in GB & IE (Great Britain & Republic of Ireland). This edition incorporates PM400 Issue 4 for the purposes of installation in Smoke Control Areas
GE General Electric Heating & Air Conditioning Manuals, Catalog, Age, Data Tag Decoder
On 2018-05-15 by (mod) - Gilbarco (or Gilbarco Veeder Root) furnace
Mike
Like you I have searched for a Gilbarco (or Gilbarco Veeder Root) furnace manual that might tell us more about decoding the model data on the furnace to figure its BTU rating - with no success though I'll continue to look.
It would help if you'd add a photo of the data tag and of any other tags or labels you can find on the furnace as well as a photo of the furnace itself. Often we can find the BTUh rating on the data tag even if it's not encoded in the unit's model number.
History of Gilbarco in a nutshell:
Gilbarco was founded in 1865 by Charles Gilbert and John Barker to market their invention that processed crude oil to provide gas used in building gas lights. Five years later their company became the Gilbert and Barker Manufacturing Company.
We can speculate about the age of your heater, if it bears a "GILBARCO" brand or label, by noting that it was in 1966 that the company changed its name to Gilbarco, Inc. and moved its corporate HQ from Springfield MA to Greensboro NC. Between 1987 and 1990 Gilbarco was acquired by GE- UK.
The company's focus was on pay-at-the-pump gas pumps. Between 1999 and 2002 the Gilbarco brand was acquired by Danaher Corp. and merged with Veeder-Root.
- Adapted from History of Gilbarco at http://www.gilbarco150.com/ 2018/05/15
On 2018-05-15 by Mike
Find the btu for a Gilbarco furnace series A 6 model A-16 sereal number 295814
Goettl Air Conditioning Inc.
Gottel got promoted to its own web page now found at
Goodman HVAC - also Amana Manuals & Error Code Table
Goodman Global and Goodman Manufacturing, founded in 1982, is currently (2017) a member of the Daikin Group, Osaka, Japan, after being purchased in 2012. Goodman produces residential and commercial HVAC equipment.
Goodman Heating & Air Conditioning, 7401 Security Way Houston, TX 77040 USA Tel: 1-877-254-4729 (USA) www.goodmanmfg.com - or - www.amana-hac.com
Website: http://www.goodmanmfg.com/
Grant Boilers, Grant Euroflame, Grant Engineering
GRANT BOILERS Grant Euroflame (Grant Engineering U.K.)
Grant also makes their service manuals available via a smartphone app. Perhaps they can also be downloaded by computer from the company's website too, though I didn't find that source. Quoting from the company's website:
Launched in 2015, the Grant TechBox is exactly what its name suggests – an electronic source which stores all the Grant product technical manuals as downloads.
Whether you need the installation manual for a product no longer manufactured, such as the Multipass boiler, or the technical information on a Grant Spira biomass boiler, the TechBox app is there to support engineers out in the field.
Grant Engineering (UK) Limited
Hopton House, Hopton Industrial Estate, Devizes, Wiltshire SN10 2EU
Telephone: (0870) 7775553 Fax: (0870) 7775559
email: info@grantuk.com website: www.grantuk.com or also www.grantuk.com/products/oil-fired-boilers/
Grant Engineering (UK) Ltd only trade in mainland UK.
For enquiries in Northern Ireland please visit the Grant NI website www.grantni.com
For enquiries in Southern Ireland please visit the Grant Engineering (Ireland) website www.grantengineering.ie
Greenheck produces energy recovery ventilators, indirect furnaces, dedicated outdoor air systems (DOAS), packaged rooftop units, HVAC duct heaters, and other HVAC equipment.
Contact Greenheck: Greenheck, P.O. Box 410
Schofield, WI 54476 USA, Tel: 715-359-6171 Website: www.greenheck.com
HAIER Air conditioners, dishwashers, electric motors
Photo: Zhang Qiu Hai Er DianJi You Xian Gong Si the manufacturer for this particular Haier electric motor, model QC.J 01 provided courtesy of reader T.J. 2017/07/14
Contact: Haier America, New York NY 10018 USA, or Haier America,
Wayne, NJ 07470 USA Web: www.Haier.com Tel: 1-800-313-8495 provides replacement parts and accessories for Haier appliances in the U.S. and Canada.
Haier appliance service center locator: Tel: 1-800-337-3639
Haier Group, Haier Industrial Park, No. 1, Haier Road, 266101, Qingdao, China, Tel: +86 532 876 36957, Tel: 1-877-337-3639 USA, Email: hractech@haier.com Email: customercare@haieramerica.com USA, Website: www.haier [DOT] com - Warning: on 2017/07/15 this website address given by the company's literature (above) could not be reached. Website: https://www.haieramerica.com/ is the company's USA web page.
Product manuals, wiring diagrams etc. were not found at the company's website (July 2017) but are available from various other online sources including haier.encompass.com
Zhangqiu Haier Electromotor Co., Ltd. is a long-established producer of Haier electric motors located in Zhangqiu Economic Development Zone Jinan, Shandong, China and doing business since 1958.
The company became a subsidiary of Haier Group in 1998. Haier electgric motors are used in household appliances such as washing machines, with other motor models used in refrigerators, air conditioners and other equipment.
Hallmark heating equipment has been manufactured in the U.S. since the 1940's,
Boyertown Furnace has owned the Hallmark OIl Fired Furnace brand since 1982.
Contact: Boyertown Furnace Company, PO Box 100, Boyertown PA 19512, Tel: 610-369-1450, Website: http://www.boyertownfurnace.com/ The company's website provides an online contact form but no mailing address, no email, no telephone.
This manual covers installation and operation of the MODU-FIRE® FORCED DRAFT 2500 & 3000 MFD. The model numbers may include a prefix to indicate special features or different options.
While details may differ slightly, basic operation is the same for all models. Boilers are built to operate with natural gas or propane. Check the rating label for the correct gas type and flow rate.
Hartley Boiler Works
Hartley Boiler Works at 704 Lafayette Street in Montgomery, Alabama. Produced tublular boilers.
Hartley & Sugden Boilers
Above: (possibly unrelated) Hartley & Sugden Atlas & Premier Works, Atlas, Advertisement from 1881.
Hartley & Sugden Limityed, Victoria Road, Gibbet St., Halifax, founded in 1867, became a publicly-held company in 1878 and from the 1920s produced the Heatanbake boiler and the Oilex range.
Below: Hartley & Sugden SCP Junior 40 Gas Fired boiler - photo source: edited & adapted from bidspotter UK.
Hearthstone Boilers & Heating Equipment
Contact: Hearthstone, HearthStone Quality Home Heating Products, Inc.®
317 Stafford Ave.
Morrisville, VT 05661 USA
E-mail: inquiry@hearthstonestoves.com
Watch out: see the US CPSC recall notice below as it involves 140,000 horizontal furnaces manufactured by Consolidated Industries - and reports of 50 fires. Note that there is no PSC has received more than 50 reports of fires associated with the 140,000 horizontal furnaces manufactured by Consolidated Industries Inc.
US CPSC FURNACE RECALL: CONSOLIDATED INDUSTRIES HORIZONTAL FURNACES [PDF] (July 2001) [Note that there is currently (2022) no remedy available to consumers and the company that announced the recall is out of business.
Excerpts WASHINGTON, D.C. - The U.S. Consumer Product Safety Commission (CPSC) is announcing a recall of about 30,000 furnaces sold in California. Seven firms are offering to repair or replace certain furnaces, which were sold under their own labels, but were manufactured by Consolidated Industries Inc.
The units involved are gas-fired horizontal furnaces equipped with steel "NOx" rods installed above the burners and are commonly called NOx rod furnaces. These furnaces pose a substantial risk of fire.
All the furnaces can be identified by the steel rods installed above the burners. The firms participating in this recall are Amana Company, L.P., of Amana, Iowa; Bard Manufacturing, of Bryan, Ohio; Carrier Corporation, of Syracuse, N.Y.; Goettl Air Conditioning Inc., of Phoenix, Ariz.; Goodman Manufacturing Company L.P., of Houston, Texas; Heat Controller Inc., of Jackson, Mich.; and The Trane Company, a division of American Standard Inc., of Tyler, Texas.
Hisense was founded in 1969 in Qingdao, China while Hisense USA is the U.S. headquarters that was established by our parent company - Hisense - in Suwanee, GA ca 2013.
Holland Furnace Co. - illustrated above in a 1937 advertisement, based in Holland, Michigan. The company, foiunded in 1906 by Kolla and his son-in-law Landwehr operated for sixty years, declaring bankruptcy in 1966.
Some interesting safety history of the Holland Furnace Co. was written by Rob Sligh, cited below.
Sligh, Rob, THE RISE AND FALL OF HOLLAND FURNACE COMPANY [PDF] The Holland Professional Club, March 2017, retrieved 2021/05/08, original source: http://www.hollandprofessionalclub.org/wp-content/uploads/2015/10/2017-March-Rob-Sligh-The-Rise-and-Fall-of-Holland-Furnace-Company.pdf
Excerpts: The Michigan Corporation and Securities Commission held hearings in 1951 involving 25
complaints that Detroit branch salesmen exaggerated the risk of asphyxiation, explosion or
fire, and the need for repairs or new furnaces.
The Company admitted the 25 complaints
were serious, but pointed out they were only a fraction of the 25 to 30 thousand house calls
made in Detroit during that period.
Holland Furnace produced an innovative, coal-fired furnace that was the best in its day.
But Holland’s innovative furnaces required different and more precise installation.
Readers may want to compare this case with BLUERAY RECALL
HTP, a subsidiary of Ariston Thermo USA, LLC, provides space heating, water heating, indirect water heating, and combination heating appliancesd as well as solar heating systems.
Contact: HTP Boiler Co., 272 Duchaine Boulevard
New Bedford, MA 02745
USA, Tel: 800 323 9651
Telephone: 508 763 8071
Fax: 508 763 3769
E-mail: sales@htproducts.com Website: htproducts.com
ICE BMA-Series GAS HEATER MANUAL [PDF] contact Midco International Inc, 4140 West Victoria Street, Chicago, Illinois 60646 Tel 773.604.8700 fax 773.604.4070 web www.midco-intl.com email sales@midco-intl.com
ICG Inter City Gas -> ICP
Question: manuyal for a 1978 IGC Furnace model ICG UFE 60A
I'm trying to find a manual for our old unit heater in the garage.
Model UFE 60 A
Says ICG on the front.
Serial #: E 431843
I'm guessing it was made in 1978. - Kathryn Elford
Moderator reply: check Intercity Gas Corporation furnace manuals
Ingersoll Rand Corporation Manuals Guides, Contact Information
Ingersoll Rand produces products under brands Club Car, IR Ingersoll Rand, Thermo King, and Trane. ThermoKing produces Thermolite solar panels and truck or van refrigeration systems.
Contact Ingersoll Rand:
Global Headquarters
170/175 Lakeview Drive
Airside Business Park
Swords, Co. Dublin
Ireland
Asia Headquarters
10/F, Tower B, City Center of Shanghai
100 Zun Yi Road Shanghai 200051
People’s Republic of China
Main Line: +0086-21-22081288
Europe Headquarters
Alma Court Building
Lenneke Marelaan 6
1932 Sint-Stevens-Woluwe
Belgium
Main Line: +32-2746-12-00
North America
800-E Beaty Street
Davidson, NC 28036
USA
+1-704-655-4000
Contact: Best Buy Brand, Web: www.insigniaproducts.com Tel: 1-877-467-4289 (U.S. / Canada) or 01-800-926-3000 (Mexico)
INSIGNIA is a trademark of Best Buy and its affiliated companies. Distributed by Best Buy Purchasing, LLC,
7601 Penn Ave South, Richfield, MN 55423 U.S.A.
Contact: Intellidyne, LLC, 303 Sunnyside Blvd. Suite 75, Plainview NY 11803 USA Tel: 516-676-0777
Inter-City Products Furnaces
Shown at left is an InterCity Products gas furnace GUI100A012GIN manufactured in 1991.
This 100K BTUI unit was included in a 2013 study of gas furnace energy efficiency improvements conducted for the U.S. Energy Agency. The study is cited just below
S. Yee, and J. Baker, "Improving Gas Furnace Performance: A Field and Laboratory Study at End
of Life L. Brand", Partnership for Advanced Residential Retrofit August 2013,
retrieved 2/27/2014, original source: http://apps1.eere.energy.gov/buildings/publications/pdfs/building_america/gas_furnace_performance.pdf NOTICE
Available electronically at http://www.osti.gov/bridge Available for a processing fee to U.S. Department of Energy and its contractors, in paper, from: U.S. Department of Energy
Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, TN 37831 Tel: 865.576.8401 email: mailto:reports@adonis.osti.gov
To identify the model of the furnaces covered by the manual listed just above, use one of the two keys give just below to decode your Inter-City furance model number.
[Click to enlarge any image]
InterCity HVAC Age Decoder
InterCity HVAC equipment manufacturing date is usually encoded in the serial number
YYWW567890
or in the serial number format
XYYWW56790
(ignore the first alphabetic character, pick up the first four numeric digits, and decode them as YYWW as we illustrate here.
Use the first four numeric digits that form YYWW where YY is year of manufacture and WW is week of manufacture in that year.
The remaining numeric digits, usually 5, form a unique serial numer or manufacturing sequence number of the equipment.
This same manufacturing date encoding appears in most HVAC equipment distributed under the ICP brands of:
Arcoaire, Comfortmaker, Heil, ICP, International Comfort Products, Inter-City Products, Keeprite, Tempstar, and UTC, United Technologies Inc.,
InterCity HVAC Manuals
Intercity Furnace Manual: INTER-CITY FURNACE SERVICE MANUAL [PDF2.1MB] for Inter-City Gas Condensing Furnaces manufactured after 1988,
I may not have this exactly right because trying to track the history of names and brands in the HVAC industry, like the plumbing industry, is a bit like playing whack-a-mole, but the Inter-City HVACR brand, before whack-a-mole'ing over to United Technologies (cf Carrier) acquired either directly or indirectly the following product names & lines: American Air Filter, Arcoaire, Comfortmaker, McQuay, Singer, Snyder General,
In 1991 Arcoaire became part of Inter-City Products (name later changed to International Comfort Products). In 1999, ICP was in turn acquired by United Technologies, the parent of Carrier Corporation.
United Technolgies, or UTC, is a conglomerate corporation based in Connecticut in the U.S. that includes also Otis, Pratt Whitney, Sikorsky, UTC Aerospace Systems,
Intertherm was re-named Nordyne Corp. in 1987, producing equipment also branded as Miller HVAC. Since 1998 Nordyne has sold equpment under the following brands: Frigidaire, Kelvinator & Gibson, Nordyne (OEM for Thermal Zone), Philco, Tappan, White-Westinghouse.
These instructions cover the installation of KCABA0301ACD and KCABA0401HPD kits into Inthertherm (See page 1) and Coleman (See page
5) electric furnace.
Excerpt: This instruction covers the installation of blower control box kit Part No. KMACC0401E14 and KMACC0601FE4. These kits are designed to add
cooling controls to Nordyne/Miller/Intertherm Electric Furnaces using the existing multi-speed furnace blower. These kits will not work with
heating-only blowers. These kits are designed for installation with a 4-wire heating/cooling thermostat.
These kits are designed to work with the electric furnaces listed below. When using the existing furnace blower in some applications, the resulting
airflow may be too low. A blower change out is recommended in any application which results in less than 350 CFM/12,000 Btuh. Blower
packages KMABA03013TE, KMABA04014TE, KMABA05013TE, and KMABA06014TE are available if blower changeout is required.
Kit Part No. KMACC0401E14 is for use with Nordyne/Miller/Intertherm E1EH and E2EH Electric Furnaces. Kit Part No. KMACC0601FE4 is
for use with Nordyne/Miller/Intertherm FEHB, FEBB, E1EH and E2EH Electric Furnaces. Refer to Table 1 for kit contents.
Refer to the
appropriate section for your furnace and control kit.
• Section 1—Installation of Kit Part No. KMACC0401E14 in Nordyne/Miller/Intertherm E1EH and E2EH Electric Furnaces
• Section 2—Installation of Kit Part No. KMACC0601FE4 in Nordyne/Miller/Intertherm FEHB and FEBB Electric Furnaces
ADVERTISEMENT
Reader Comments, Questions & Answers About The Article Above
Below you will find questions and answers previously posted on this page at its page bottom reader comment box.
Apologies but I'm not quite sure what part you're referring to. Do you mean a combustion chamber liner? If so, there are plenty of retrofit kits on the market.
On 2020-11-08
by Jim B.
I am looking for the parts Number for an Climatol gas furnace #1740-200-51-10 "Burner box" and if it still available ?? JIM.b.
On 2020-07-08 - by (mod) -
George
AUDnn are an American Standard product - please see the manuals listed at
AMERICAN STANDARD AGE MANUALS & PARTS GUIDES boilers & furnaces
AUD100 series I need a service Manuel. I need to adjust the dip switches for a five ton air conditioning system (2,000 cfm)
On 2020-05-25 - by (mod) -
Thomas
I'll be glad to see if we have or can find the service manual you need, but we'll have a better time of it if you can tell me the brand that goes with that model number; a photo of the unit would be great too.
On 2020-05-25 by Thomas Metcalf
Need owners manual HVAC model # PGMD24G0602 Forced Air Furnace with Cooling Unit, outdoor only
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Comments & Questions are Welcome Here
If you posted comments here and no longer see what you wrote, please check for your comment in the Reader Q&A found above on this page.
Citations & References
In addition to any citations in the article above, a full list is available on request.
In addition to citations & references found in this article, see the research citations given at the end of the related articles found at our suggested
Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. Tel: (416) 964-9415 1-800-268-7070 Email: info@carsondunlop.com. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
Carson Dunlop Associates provides extensive home inspection education and report writing material. In gratitude we provide links to tsome Carson Dunlop Associates products and services.