This article lists significant wood frame and masonry wall structural defects, definitions, and home inspection education topics.
This article series, beginning at BUILDING DEFECTS LISTS , provides lists of common building defects and basic defect knowledge that also outline recommended curriculum content for home inspector education. The building defects and inspection points listed in these articles also guide homeowners and home buyers to building areas that merit careful attention and often point areas of safety concern or important maintenance and repair tasks.
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
These curriculae and building defect lists are based on smilar curriculum documents first prepared by Joe Scaduto, an ASHI member who prepared course material for Northeastern University's Building Inspection Certificate program in 1988, subsequently by DF, InspectApedia's editor, for New York University ca 1988 and later, with others, recommended to ASHI, the American Society of Home Inspectors.
ASHI did not adopt this material though currently that association as well as others offer extensive HOME INSPECTOR EDUCATION material. The curriculum and lists of defects are informed by additional analysis of the process of home inspection that was developed beginning Calgary, AB for Canadian and U.S. home inspector education and certification examinations in 1997.
Other early contributors to home inspection education in the U.S. and Canada include Dr. Jess Aronstein, Alan Carson, Mike Casey, Mark Cramer, John Cox, Dwight Barnett, Douglas Hansen, Rick Heyl, Larry Hoytt, Bill Merrill, Kevin O'Malley, Dennis Robitalille, Keith Peddie, Pat Porzio, Roger Robinson.
1. Describe the function of interior and exterior house wall systems. Differentiate between loading bearing and partition walls.
2. Describe these types of common house wall construction: solid masonry, wood frame, masonry veneer.
3. List the materials and components of each of the wall types above.
4. Describe the features of adequate installation and repair technique for each of the wall types above.
5. Define the following terms:
wythe, header brick, stretcher brick, lateral support for walls, lintel, arch, rafter spread, brick expansion, bowing wall, corbeling, platform framing, balloon framing, sole plate, bottom plate, base plate, sill plate, top plate, jack stud, girt, offset bearing wall, fire stopping, vented rain screen principle, weep hole, efflorescence, brick ties, rope wicks, shear walls.
6. Identify the codes or standards which apply to wall systems in your area.
1. Describe the inspection procedure for exterior and interior walls.
2. Identify the common wall defects listed on the next page.
3. Describe the implication of each defect.
4. Communicate findings to client verbally and in writing, recommending corrective action where needed.
Also see BRICK FOUNDATIONS & WALLS
and BRICK VENEER WALL Loose, Bulge
Also see BRICK FOUNDATIONS & WALLS and BRICK VENEER WALL LOOSE, BULGED
Readers should see STRUCTURAL INSPECTIONS & DEFECTS for our complete list of articles on this topic.
Also see HOME & BUILDING INSPECTORS & INSPECTION METHODS. Use the Search Box at the top or bottom of these pages to find in-depth information about building, energy savings, and indoor environment inspection, diagnosis and repair at this website.
Watch out: these inspection lists do not list all possible defects for the systems discussed, and not all home or building inspectors will examine all of the items listed here. CONTACT us to suggest corrections or additions to articles at this website
...
Continue reading at ARTICLE INDEX to BUILDING DAMAGE, DISASTER, REPAIR or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
STRUCTURE, WALL DEFECTS LIST at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.