This article provides EPA advice about asbestos hazards in some vermiculite insulation
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.
This page provides important information on how to protect yourself and your family if you suspect that you might have vermiculite insulation from Libby, Montana.
Vermiculite is a naturally-occurring mineral composed of shiny flakes, resembling mica. When heated to a high temperature, flakes of vermiculite expand as much as 8-30 times their original size. The expanded vermiculite is a light-weight, fire-resistant, and odorless material and has been used in numerous products, including insulation for attics and walls. Sizes of vermiculite products range from very fine particles to large (coarse) pieces nearly an inch long.
A mine near Libby, Montana, was the source of over 70 percent of all vermiculite sold in the United States from 1919 to 1990. There was also a deposit of asbestos at that mine, so the vermiculite from Libby was contaminated with asbestos. Vermiculite from Libby was used in the majority of vermiculite insulation in the United States and was often sold under the brand name Zonolite. If you have vermiculite insulation in your home, you should assume this material may be contaminated with asbestos and be aware of steps you can take to protect yourself and your family from exposure to asbestos.
Look at the photos on this website and then look at the insulation without disturbing it. Vermiculite insulation is a pebble-like, pour-in product and is usually gray-brown or silver-gold in color.
The following photographs show typical vermiculite insulation.
You should assume that vermiculite insulation is from Libby and treat the material as if it contained asbestos by not disturbing it or by using a trained professional if it needs to be removed. Since the Libby mine was estimated to be the source of over 70 percent of all vermiculite sold in the United States from 1919 to 1990 and vermiculite from Libby was contaminated with asbestos, further testing is not necessary to take the appropriate precautions. While you can hire a trained professional to test your attic for asbestos, this may be expensive and, depending on the methods used, might give you erroneous results. We do not recommend that you open your walls to check for vermiculite.
Asbestos causes cancer and other diseases. There is no known safe level of asbestos exposure. Asbestos fibers must be airborne to cause a health risk through inhalation, so the first step is not to disturb the material, which would release more fibers into the air. If you remove or disturb the insulation, it is probable that you may inhale some asbestos fibers - the degree of health risk depends on how much and how often this occurred. If you do not go into your attic, handle, or disturb the insulation, it is likely that you will not be exposed to asbestos fibers from vermiculite insulation.
Also, you need to consider if any disturbance of the insulation - possibly by a contractor doing work in your attic - may result in the fibers being deposited into other areas of your house where an exposure might be possible.
It is not possible to say whether your exposure may result in disease. Exposure to asbestos increases your risk of developing lung diseases including asbestosis, lung cancer, or mesothelioma, and disease may not occur until decades after exposure. The risk of disease increases as the level, duration, and frequency of exposure increases. That risk is made worse by smoking.
If you are concerned about possible exposure, talk to your doctor and consider consulting a physician who specializes in lung diseases, also known as a pulmonologist. For more information on asbestos-related diseases see the Agency for Toxic Substances & Disease Registry Web site.
YOU SHOULD ASSUME THE VERMICULITE CONTAINS ASBESTOS AND DO NOT DISTURB IT! Any disturbance could potentially release asbestos fibers into the air. If you absolutely have to go in your attic and it contains vermiculite insulation, you should limit the number of trips you make and shorten the length of those trips in order to help limit your potential exposure.
We recommend that you:
...
Continue reading at VERMICULITE INSULATION - home, or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.
Or see these
US EPA PROTECT YOUR FAMILY FROM ASBESTOS-CONTAMINATED VERMICULITE INSULATION (2013) - retrieved de-novo 2024/01/05, original source: epa.gov/asbestos/protect-your-family-asbestos-contaminated-vermiculite-insulation at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.
Or see this
Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia
Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.
Search the InspectApedia website
Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.
Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca
In addition to any citations in the article above, a full list is available on request.