Mobile ViewBUILDING INTERIORS ACOUSTICAL SEALANT CHOICES AGE of a BUILDING - how to determine AGE of PLUMBING MATERIALS & FIXTURES AGE of CHIMNEYS & FIREPLACES AGE of AIR CONDITIONERS & HEAT PUMPS AGE of FOUNDATION MATERIALS AGE of FRAMING MATERIALS AGE of FLOORING MATERIALS AGE of ELECTRICAL WIRING AGE of HEATERS, BOILERS, FURNACES AGE of WATER HEATERS ACOUSTICAL SEALANT CHOICES AIR BYPASS LEAKS AIR LEAK DETECTION TOOLS AIR LEAK MINIMIZATION AIR POLLUTANTS, COMMON INDOOR AIR LEAK SEALING PROCEDURE AIR SEALING STRATEGIES ANIMAL ALLERGENS APPLIANCE EFFICIENCY RATINGS ARCHITECTURE & BUILDING COMPONENT ID ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings ASBESTOS LIST of PRODUCTS ASBESTOS PHOTO GUIDE to Materials ASBESTOS REMOVAL, Wetting Guidelines ATTIC LEAKS, CONDENSATION & MOLD ATTIC VENTILATION BASEMENT CEILING VAPOR BARRIER BASEMENT HEAT LOSS BASEMENT LEAKS, INSPECT FOR BASEMENT WATERPROOFING BATH & KITCHEN DESIGN GUIDE BATHROOM VENTILATION BEST CONSTRUCTION PRACTICES GUIDE BLOWER DOORS & AIR INFILTRATION BLOWER FAN CONTINUOUS OPERATION BLOWER FAN OPERATION & TESTING BLOWN-IN INSULATION BOOKSTORE BRICK LINED WALLS BRICK VENEER WALL INSULATION BRICK VENEER WALL Loose, Bulged BRICK WALL DRAINAGE WEEP HOLES BUCKLED FOUNDATIONS due to INSULATION? BUILDING NOISE DIAGNOSIS & CURE CABINETS & COUNTERTOPS CACTUS FUNGI / MOLD CAR MOLD CONTAMINATION CARPET DUST IDENTIFICATION CARPET MOLD CONTAMINATION CARPET PADDING ASBESTOS, MOLD, ODORS CARPET STAIN DIAGNOSIS CARPET & other STAIN TESTS CARPET TEST PROCEDURE CARPETING & INDOOR AIR QUALITY CARPETING, SELECTION & INSTALLATION CATHEDRAL CEILING INSULATION CATHEDRAL CEILING VENTILATION CEILING FINISHES INTERIOR CEILINGS, DROP or SUSPENDED PANEL CEILINGS, PLASTER TYPES CEILINGS, PLASTER, LOOSE HAZARDS CHIMNEY INSPECTION DIAGNOSIS & REPAIR CHINESE DRYWALL HAZARDS COMBUSTION AIR for TIGHT buildings CONDENSATION or SWEATING PIPES, TANKS COOLING LOAD REDUCTION by ROOF VENTS CRAWL SPACES DECK & PORCH CONSTRUCTION DEW POINT CALCULATION for WALLS DEW POINT TABLE - CONDENSATION POINT GUIDE DIRECTORY of MOLD / ENVIRONMENTAL EXPERTS DIRT FLOOR MOLD CONTAMINATION Disinfectants Disinfecting Buildings with Bleach DOORS, INTERIOR DRYER VENTING DRYWALL HAZARDS, CHINESE DRYWALL INSTALLATION Best Practices DRYWALL MOLD DRYWALL MOLD RESISTANT EFFLORESCENCE, Salts & White / Brown Deposits ELDERLY & VETERANS HOME SAFETY ENGINEERED WOOD Flooring EXTERIOR WALL SIDING TRIM & FINISHES FIBERGLASS INSULATION FIBERGLASS HAZARDS FIBERGLASS INSULATION MOLD FLAT ROOF MOISTURE & CONDENSATION FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP FLOOD DAMAGED FOUNDATIONS FLOOD VENTS & FLOOD PORTS FLOODS IN buildings-mold FLOOR TYPES & DEFECTS FLOOR, CERAMIC TILE FLOOR, CONCRETE SLAB CHOICES FLOOR, CONCRETE SLAB POURED FINISH FLOOR DAMAGE DIAGNOSIS FLOOR, ENGINEERED WOOD & LAMINATES FLOOR FRAMING & SUBFLOOR for TILE FLOOR, KITCHEN & BATH OPTIONS FLOOR, LAMINATE PLASTIC FLOOR RADIANT HEAT Mistakes to Avoid FLOOR, RESILIENT VINYL or CORK FLOOR, STONE, GRANITE, MARBLE, AGGLOMER FLOOR & SUBFLOOR MOLD, HIDDEN FLOOR TILE ASBESTOS IDENTIFICATION FLOOR TILE HISTORY & INGREDIENTS FLOOR WOOD AGE TYPES HISTORY FLOOR WOOD, DAMAGE DIAGNOSIS FLOOR, WOOD ENGINEERED, LAMINATE, INSTALL FLOOR, WOOD FINISHES FLOOR, WOOD INSTALLATION GUIDE FLOOR, WOOD MOISTURE FLOOR, WOOD RADIANT HEAT FLOOR, WOOD SOLID STRIP, PLANK FLOOR, WOOD TYPES FLOORING MATERIALS, Age, Types FORMALDEHYDE HAZARDS FOOTING & FOUNDATION DRAINS FOUNDATION BULGE or LEAN MEASUREMENTS FOUNDATION CRACKS & DAMAGE GUIDE FOUNDATION WATERPROOFING FRENCH DRAINS FRAMING DAMAGE, INSPECTION, REPAIR FRAMING DETAILS for BETTER INSULATION FREEZE-PROOF A BUILDING FROST HEAVES, FOUNDATION, SLAB FUNGICIDAL SPRAY & SEALANT USE GUIDE GAS DETECTION & MEASUREMENT GAS EXPOSURE EFFECTS, TOXIC Carbon Dioxide - CO2 Carbon Monoxide - CO METHANE GAS SOURCES GAS EXPOSURE LIMITS & STANDARDS GAS EXPOSURE TEST PROCEDURES HEAT LOSS in buildings HEAT LOSS DETECTION TOOLS HEAT LOSS INDICATORS HEAT LOSS PREVENTION PRIORITIES HEAT LOSS R U & K VALUE CALCULATION HEAT TAPES & CABLES on Roofs for Ice Dams HEATING COST SAVINGS METHODS HOT ROOF DESIGNS: Un-Vented Roof Solutions HOUSEWRAP AIR & VAPOR BARRIERS HOUSE DOCTOR, how-to be HUMIDITY LEVEL TARGET ICE DAM PREVENTION INDOOR AIR QUALITY & HOUSE TIGHTNESS INDOOR AIR QUALITY IMPROVEMENT GUIDE INDOOR HOUSE DUST & DEBRIS INSULATION CHOICES Insulation Air & Heat Leaks INSULATION FACT SHEET- DOE INSULATION for GREENHOUSE or SOLARIUM INSULATION IDENTIFICATION GUIDE INSULATION INSPECTION & IMPROVEMENT INSULATION LOCATION - WHERE TO PUT IT INSULATION LOCATION for BRICK VENEER WALLS INSULATION LOCATION for CAPES, CRAWLSPACES INSULATION LOCATION for CATHEDRAL CEILINGS INSULATION LOCATION for GREENHOUSE or SOLARIUM INSULATION MOLD INSULATION R-Values & Properties INTERIOR FINISHES: BEST PRACTICES INTERIOR FINISHES: DRYWALL KIT HOMES, Aladdin, Sears, Wards, Others KITCHEN & BATH DESIGN GUIDE LIGHTING, EXTERIOR GUIDE LIGHTING, INTERIOR GUIDE LOG HOME GUIDE METAL LATH, PLASTER & STUCCO MOBILE HOME INSPECTIONS MOISTURE CONTROL in BUILDINGS MOLD: A COMPLETE GUIDE TO MOLD MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD MOLD APPEARANCE - WHAT MOLD LOOKS LIKE MOLD CLEANERS - WHAT TO USE MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD MOLD CONSULTANTS/INSPECTORS MOLD CULTURE TEST KIT VALIDITY MOLD DETECTION & INSPECTION GUIDE MOLD or INDOOR AIR EMERGENCY RESPONSE MOLD EXPERT, WHEN TO HIRE MOLD FAQ's MOLD ODORS, MUSTY SMELLS MOLD PREVENTION GUIDE MOLD RELATED ILLNESS GUIDE MOLD SAFETY WARNINGS MOLD SPRAYS, SEALANTS, PAINTS MOLD STANDARDS MOLD TEST KITS for DIY MOLD TESTS MOLD TESTING METHOD VALIDITY Nanomaterials Hazards NOISE / SOUND DIAGNOSIS & CURE NOISE, AIR CONDITIONER COMPRESSOR NOISE, DUCT VIBRATION DAMPENERS NOISE CONTROL for HEATING SYSTEMS NOISE CONTROL for FLOORS NOISE CONTROL for PLUMBING NOISE CONTROL for ROOFS NOISES COMING FROM WATER HEATER ODORS & SMELLS DIAGNOSIS & CURE PASCAL CALCULATIONS PAINT FALURE, DIAGNOSIS, CURE, PREVENTION PLASTER PLASTER & BEAVERBOARD & DRYWALL PLASTER BULGES & PILLOWS PLASTER LATH, METAL PLASTER, LOOSE FALL HAZARDS PLASTER TYPE IDENTIFICATION PLASTER VENEER Best Practices PLASTER VENEER Best Practices RADIANT HEAT RADIANT HEAT Floor Mistakes to Avoid RADIANT HEAT TEMPERATURES RADIANT SLAB FLOORING CHOICES RADIANT SLAB TUBING & FLUID CHOICES ROOF VENTILATION SPECIFICATIONS ROT, FUNGUS, TERMITES ROT, TIMBER FRAME SAFETY HAZARDS & INSPECTIONS SAFETY: Elderly & Veterans Home Safety SAFETY for ELECTRICAL INSPECTORS SEARS KIT HOUSES SINKHOLES, WARNING SIGNS SINKING BUILDINGS SLAB CRACK EVALUATION SOUND CONTROL in buildings Splits in Structural Wood Beams STAIN & BIODETERIORATION AGENT CATALOG STAINS on buildings - QUICK GUIDE STAIN DIAGNOSIS on BUILDING EXTERIORS STAIN DIAGNOSIS on BUILDING INTERIORS STAIN DIAGNOSIS on ROOFS STAIN DIAGNOSIS on STONE STAINS & FINISHES, INTERIOR STAINS on INDOOR SURFACES: PHOTO GUIDE STAIRS, RAILINGS, LANDINGS, RAMPS STONE CLEANING METHODS STRESS SKIN INSULATED PANELS STUCCO WAll FAILURES DUE TO WEATHER STUCCO WALL METHODS & INSTALLATION STUCCO OVER FOAM INSULATION STUCCO PAINT FAILURES SUMP PUMPS GUIDE SWEATING (CONDENSATION) on PIPES, TANKS THERMAL EXPANSION of MATERIALS THERMAL MASS in buildings THERMAL TRACKING Indicates Heat Loss TILE INSTALLATION DETAILS TRIM, INTERIOR INSTALLATION TRUSS UPLIFT, ROOF TRUSSES, Floor & Roof VAPOR BARRIERS & CONDENSATION in BUILDINGS VENTILATION in buildings VINYL Siding or PLASTIC Window ODORS in buildings VINYL CHLORIDE HEALTH INFO WALL SIDING TRIM & FINISHES WALL FINISHES INTERIOR WATER BARRIERS, EXTERIOR BUILDING WATER ENTRY in buildings WIND WASHING INSULATION At EAVES WINDOWS & DOORS WINTERIZE A BUILDING WOOD Burning Heaters Fireplaces Stoves WOOD FLOOR DAMAGE More Information |
This article defines and illustrates types of modern wood flooring, including solid wood floors, engineered wood floors, and laminate wood floor products. We also illustrate wood lookalike laminate flooring products. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.Our home page for all information about wood flooring is at FLOOR TYPES & DEFECTS. And at FLOOR, WOOD ENGINEERED, LAMINATE, INSTALL provide details about the selection and installation of engineered wood and laminated wood floors. Our page top photo illustrates what can happen to an engineered-wood floor (or any wood floor for that matter) if it is exposed to flooding from a burst plumbing or heating pipe. Also see INTERIORS of buildings, our home page for information about all topics relating to building interiors. © Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Definition of flooring types: Hardwood flooring, Engineered Wood Flooring, Laminate FlooringHere we define three basic types of flooring products: hardwood flooring, engineered wood flooring, and laminate flooring. We illustrate each of these floor covering approaches with flooring sample photographs below. [Solid] Hardwood flooring is illustrated by our photo at below-left. This hardwood flooring sample is Vintage Maple Natural 3/4" thick x 3 1/4" wide tongue and groove flooring produced by Tarkett and has a hardness rating of 4 on a 1 to 5 scale. Solid hardwood flooring is just that - flooring material made out of a single piece of hardwood, usually cut into a tongue-and-groove profile that is installed to the subfloor by nailing through the tongue on a diagonal into the floor board and into the subfloor below. Engineered wood flooring is illustrated by our second photo at below right. Shown is Click Bamboo-Toast 9/16" flooring available through Home Depot® stores. Engineered wood flooring combines a top layer of wood that is bonded to multiple plies of softwood that affords uniformity and dimensional stability. Engineered wood flooring is sold in a variety of edge profiles including tongue-and groove and "click" flooring whose planks interlock together. Engineered wood flooring may be nailed or stapled to the subfloor or in some products it is installed as a floating floor over the subfloor.
Laminate flooring, including laminate wood flooring looks like a hardwood floor, provides a hard surable surface, but is usually less costly per square foot than the solid or engineered wood floor products above. At below left is a laminate floor product that provides a thin vinyl skin with a wood grain image. This click-lock laminate floor product (Palace Oak Light) is produced by Home Legend™ and is warranted for 55 years in residential use. At below right our photograph shows another Home Legend™ flooring product, Tigerwood, that is sold in three flooring versions: 3 1/2" wide x 3/8" "click" (shown in our photo), also available in 1/2" thick engineered wood design, and also sold in a 3 1/4" wide x 3/4" solid wood version.
Sorting out the Confusion: What's the Difference Between Engineered Wood Flooring and Laminate Wood FlooringWhat's the difference beween an engineered wood flooring product and a laminated wood flooring product? It's confusing looking through flooring types, labels, and samples at wood floor suppliers like Home Depot® where dozens of choices are available. But the answer to the question of the difference beween engineered wood floors and laminate wood floors lies in the thickness of the top or exposed wood layer. Engineered wood flooring has a top or exposed real wood layer that is typically 1/8" or greater in thickness, bonded to plies of softwood below. Laminated wood flooring also has a top or exposed layer of real wood, but typically in a layer that may be just 1/16" or even less (shown at above right). A laminated wood floor surface is not one that you are likely to ever try to re-finish by sanding - the top veneer is just too thin. But then, some of these laminates are warranted for a long time in residential use. An engineered wood floor can often be sanded and re-finished if necessary - perhaps once. FLOOR, WOOD ENGINEERED, LAMINATE, INSTALL provides details about the selection and installation of engineered wood and laminated wood floors. Comparing Engineered Wood Floors to Solid Wood Floors
A solid wood floor may or may not be capable of being sanded and re-finished - it depends. While there are some pre-finished solid wood floors that are dead smooth (no V-groove), most pre-finished solid wood floors have at least a slight champfer along the floor boards' edges - see our photo at left. That produces a shallow "Vee" groove between adjacent pre-finished flooring planks. The V-groove hides slight differences in flooring thickness or installation variaitons that otherwise might appear. But the V-groove means that you cannot easily sand and refinish the flooring since doing so risks leaving Vees insome areas and not others - really a wierd looking result. Of course with the thickness of a full 3/4" solid wood floor you probably have enough thickness to sand shallow vee grooves right out of existence should floor sanding and re-finishing become really necessary. Resources: Manufacturers, Industry Associations, & Sources of Indoor Engineered Wood and Wood Laminate Flooring MaterialsPrefinished Wood FlooringAlloc Inc. www.alloc.com Snap-together, no-glue long-strip and single-strip laminated flooring Anderson Hardwood Floors www.andersonfloors.com Laminated strip, nail, glue, and floating Armstrong World Industries www.armstrong.com Bruce, Hartco, and Robbins prefinished plank and engineered strip BHK of America www.bhkuniclic.com Snap-together, no-glue laminated wood flooring Columbia Wood Flooring www.columbiaflooring.com Prefinished solid strip Duro-Design www.duro-design.com Floating click-lock oak flooring Gammapar www.gammapar.com Engineered wood strip with oil, UV-cured urethane, or acrylic-impregnated finish Junkers Hardwood www.junkershardwood.com Floating solid strip with metal clip installation Kahrs www.kahrs.com Laminated strip with UV-cured acrylic urethane, nail, glue, or floating Lauzon www.lauzonltd.com Prefinished strip, laminated strip, and click-lock laminated plank Mannington Mills www.mannington.com Laminated strip and plank with polyurethane and aluminum-oxide finish Medallion Hardwood Flooring www.medallionhardwood.com Prefinished solid hardwood strip and plank with aluminum-oxide finish Tarkett Wood Floors www.harris-tarkett.com Prefinished solid hardwood, laminated, and long-strip flooring MercierWood Flooring www.mercierdurable.com Prefinished solid strip and laminated strip with aluminum-oxide finish PermaGrain Hardwood Flooring www.permagrain.com Acrylic-impregnated laminated strip and plank Zickgraf Hardwood Flooring www.zickgraf.com Prefinished solid strip with UV-cured urethane with diamond and aluminum oxide Bamboo Flooring Producers & SourcesBamtex (a division of Wood Flooring International) www.bamtex.com Laminated bamboo and palm flooring Duro-Design www.duro-design.com Laminated bamboo flooring with durable water-based finish Gammapar www.gammapar.com Acrylic-impregnated bamboo flooring Hawa Bamboo Flooring www.hawabamboo.com Prefinished bamboo flooring with aluminum-oxide finish Natural Cork www.naturalcork.com Prefinished glue-down or nail-down 3-ply bamboo planks with aluminum-oxide finish Resilient Flooring Manufacturers ListCongoleum www.congoleum.com Vinyl sheet flooring and tiles Domco (division of Domco Tarkett Group) www.domco.com Vinyl sheet flooring and tiles Forbo www.forbo-flooring.com Linoleum sheet and tiles Mannington Mills www.mannington.com Vinyl sheet flooring and tiles Nova Distinctive Floors www.novafloorings.com Laminated linoleum surface over fiberboard and cork planks, floating installation Tarkett www.tarkettna.com Vinyl sheet flooring and tiles Cork Flooring Manufacturers & SourcesAmerican Cork Products Co. www.amcork.com Prefinished parquet tiles and floating floor planks Amorim Revestimentos (formerly Ipocork) www.wicanders.com Floating or glue-down laminated cork tiles with UV-acrylic or oil finish BHK of America www.bhkuniclic.com Snap-together, no-glue, laminated cork flooring with UV-acrylic finish Expanko Cork Inc. www.expanko.com Cork tiles with wax or polyurethane finish Korq Inc. (212) 758-2593 Natural Cork www.naturalcork.com Glue-down cork tiles and floating laminated planks with UV-cured acrylic finish Nova Distinctive Floors www.novafloorings.com Laminated cork planks with glue-down and floating click-lock installation WECork www.wecork.com Cork tiles, sheets, and floating floors -- Above list adapted with permission from Best Practices Guide to Residential Construction. Questions & Answers regarding this article. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...