AIR BYPASS LEAKS AIR LEAK DETECTION TOOLS Find Heat Loss & Air Leaks Heat Loss Investigation Sequence Blower Door Test Data Results Smoke Gun for Air Leaks Smoke Pencil / Smoke Gun Suppliers Attic Energy Losses - InfraRed Basement Energy Losses- IR & Visual Duct System Air Movement Living Space Heat Loss Targets & Hidden Leak Points Thermography IR Infra Red & Thermal Scanners Convective Loops & Thermal Bypass Leaks Insulation Air & Heat Leaks The Bottom Line on Energy Retrofits AIR LEAK MINIMIZATION AIR SEALING STRATEGIES ASBESTOS IDENTIFICATION IN BUILDINGS ATTIC LEAKS, CONDENSATION & ATTIC MOLD BLOWER DOORS & AIR INFILTRATION CARPET TEST GUIDE ENERGY SAVINGS in BUILDINGS FRAMING DETAILS for BETTER INSULATION FRAMING DETAILS for DOUBLE WALL HOUSES HEAT LOSS in BUILDINGS HEAT LOSS DETECTION TOOLS HEAT LOSS INDICATORS HEAT LOSS PREVENTION PRIORITIES HEAT LOSS R U & K VALUE CALCULATION Heat Tapes: Use on Roofs for Ice HEATING COST SAVINGS METHODS HEAT LOSS CALCULATIONS HEATING SYSTEMS HOUSEWRAP AIR & VAPOR BARRIERS HUMIDITY LEVEL TARGET ICE DAM PREVENTION INDOOR AIR QUALITY IMPROVEMENT GUIDE INSULATION INSPECTION & IMPROVEMENT Insulation Air & Heat Leaks INSULATION LOCATION for BASEMENT FLOORS INSULATION LOCATION for BRICK VENEER WALLS INSULATION LOCATION for CAPES, CRAWLSPACES INSULATION LOCATION for CATHEDRAL CEILINGS INSULATION LOCATION for GREENHOUSE or SOLARIUM INSULATION R-Values & Properties INTERIORS of BUILDINGS Investigation of Indoor House Dust Debris MOLD INFORMATION CENTER MOLD APPEARANCE - WHAT MOLD LOOKS LIKE MOLD APPEARANCE - STUFF THAT IS NOT MOLD MOLD INSPECTORS & MOLD TESTERS ROOF VENTING ENERGY SAVING DETAILS SIDING WOOD STAIN DIAGNOSIS on Building Exteriors STAIN DIAGNOSIS on Indoor Surfaces STAINS on Indoor Surfaces: PHOTO GUIDE THERMAL TRACKING & THERMAL BRIDGING What is Thermal Tracking Ceiling Thermal Tracking Marks Wall Thermal Tracking Stains Floor Carpet Thermal Tracking Stains Air Bypass Leaks Marks on Insulation Thermal Tracking to Diagnose IAQ Stains HVAC Supply Registers Pet Stains on Floors Pet Stains on Walls Human Occupant Stains on Walls Stains from Candles, Woodstoves, Fireplaces Other Stains on Indoor Walls & Ceilings What to Do About Thermal Tracking THERMAL EXPANSION of MATERIALS THERMAL MASS in BUILDINGS THERMAL MASS FLOOR SLABS THERMAL MASS in UPSTAIRS THERMAL MASS WALL DESIGN VAPOR BARRIERS & AIR SEALING at BAND JOISTS VAPOR BARRIERS & CONDENSATION in BUILDINGS VAPOR BARRIERS & HOUSEWRAP VAPOR CONDENSATION & BUILDING SHEATHING SIDING WOOD STAIN DIAGNOSIS on Building Exteriors STAIN DIAGNOSIS on Indoor Surfaces STAINS on Indoor Surfaces: PHOTO GUIDE More Information InspectAPedia Blog - News Updates Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Plumbing Water Septic Roofing Structure Accuracy & Privacy Policies Contact Us |
This article describes, provides identification photographs, & diagnoses the cause certain How to Recognize & Diagnose Pet Stains on Building Walls and links to other causes of various interior wall and ceiling stains and explains how to recognize thermal tracking, thermal bridging stains, building air leaks, and building insulation defects. Often these stains are mistaken for toxic indoor mold. When investigating a building for a mold problem, you can save mold test costs by learning how to recognize Stuff that is Not Mold or is only Harmless Mold but may be mistaken for more serious contamination - save your money. Because some clients have on occasion sent samples to our mold test lab that really should not have been collected, much less looked-at, we provide this library of photographs of things that are "not mold" and don't need to be tested. These are substances that you can easily learn to recognize in buildings. Save your mold test money, and increase the accuracy of your mold contamination inspection or test for toxic or allergenic mold in buildings: review these items to learn recognize non-fungal materials or even possibly harmless cosmetic "black mold" often mistaken for "toxic fungal growth." Readers should see HEAT LOSS in BUILDINGS. Also see AIR SEALING STRATEGIES and AIR LEAK DETECTION TOOLS as well as AIR LEAK MINIMIZATION. For photos of snow melt on rooftops that also show points of building heat transfer and loss, see STAIN DIAGNOSIS on Building Exteriors. © Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. How to Recognize Pet Stains on Building Walls
How to Recognize Wall Stains from Human Occupants
We welcome more thermal tracking, soot tracking, air bypass leaks, and similar photos of indoor stains as well as text suggestions to expand this detail and would be glad to credit contributors. Usually soot marks, thermal bridging, or thermal tracking stains appear, if at all, in the building interior locations discussed in the remaining sections of this article. ... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. THERMAL TRACKING
|
||||||
|
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY MOLD INFORMATION CENTER WHAT MOLD LOOKS LIKE MOLD IN HOMES USING LIGHT TO FIND MOLD MOLD BY MICROSCOPE STUFF THAT IS NOT MOLD DIAGNOSE OTHER DARK STAINS on Indoor Surfaces STAINS on Indoor Surfaces: PHOTO GUIDE CARPET TEST GUIDE Investigation of Indoor House Dust Debris More Information InspectAPedia Blog - News Updates Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Privacy Policies Contact Us |
More Information on Building Diagnostic Inspections and Repairs
|