InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


mobile guide to mold in buildingsMobile View
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

MOLD: A COMPLETE GUIDE to TEST CLEAN PREVENT

ACCEPTABLE MOLD LEVEL
ACCURACY OF VARIOUS MOLD TEST METHODS

ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
ACTIVITY of MOLD in buildings
AGE of MOLD - Old is the Mold?

AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY
AIRBORNE MOLD SPORE COUNT ACCURACY
AIRBORNE PARTICLE ANALYSIS METHODS

ALLERGEN TESTS for buildings
ALLERGENS in buildings, RECOGNIZING
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY

ATTORNEYS and EXPERT WITNESSES
ATTIC MOLD

BASEMENT MOLD
BASEMENT MOLD WATER IMPACT
BASICS YOU NEED to FIND, TEST, REMOVE MOLD
BASKETBALL MOLD SYNDROME - BBMS
BATHROOM MOLD
BROWN HAIRY BATHROOM MOLD
BIBLIOGAPHY for ENVIRONMENTAL HEALTH, MOLD, IAQ

BIOLOGICAL POLLUTANTS
BIOLOGICAL POLLUTANTS in the HOME - EPA
Bisphenol-A, BPA

BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC

BLEACHING MOLD, Advice about
BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
BUY PRODUCTS for MOLD & ALLERGY CONTROL
BUYERS GUIDE - home inspections for mold

CARPET DUST IDENTIFICATION
CARPET MOLD CONTAMINATION
CARPET PADDING ASBESTOS, MOLD, ODORS
CARPET FUNGICIDAL SPRAY
CARPET STAIN DIAGNOSIS
CARPET & other STAIN TESTS
CARPET TEST GUIDE
CARPETING & INDOOR AIR QUALITY
CARPETING, SELECTION & INSTALLATION

CHAIN OF CUSTODY - TEST SAMPLE

CLEARANCE INSPECTIONS - MOLD CLEANUP
CONSTRUCTION DETAILS TO AVOID MOLD
CRAWL SPACES

DIRT FLOOR MOLD CONTAMINATION
DO IT YOURSELF MOLD CLEANUP
DO-IT-YOURSELF MOLD CLEANUP WARNINGS
DRYWALL MOLD

DUCT SYSTEM & DUCT DEFECTS
DUST ANALYSIS for FIBERGLASS
DUST CONTAMINATION FROM HVAC?
DUST SAMPLING PROCEDURE

EFFLORESCENCE, Salts & White / Brown Deposits
ESSENTIAL STEPS IN FINDING MOLD

FEAR of MOLD - MYCOPHOBIA
Fiberboard Insulation Sheathing Mold

FIBERGLASS INSULATION MOLD
FIBERGLASS PARTICLE CONTAMINATION TEST

FIELD INVESTIGATION SERVICE

FIND MOLD, ESSENTIAL STEPS
FIND MOLD in buildings, HOW TO

FIRE DAMAGE vs MOLD DAMAGE

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODS IN buildings-mold

FLOORING MATERIALS, Age, Types

FUNGICIDAL SPRAY & SEALANT USE GUIDE

GASES, EXPOSURE, TESTING
GAS MEASUREMENT TOOLS
Gas Toxicity Levels
GAS EXPOSURE EFFECTS
GAS TEST PROCEDURES

House Dust Analysis

HOUSEWRAP AIR & VAPOR BARRIERS
HIDDEN MOLD, HOW TO FIND

HUMIDITY CONTROL & TARGETS INDOORS

INDOOR AIR HAZARDS TABLE
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE

INSULATION INSPECTION & IMPROVEMENT
INSULATION MOLD
ITCHY FABRICS

LABORATORY SERVICES
LAB PROCEDURES MICROSCOPE TECHNIQUES

MICROSCOPE DIGITAL PHOTOGRAPHY
Digital Photography & the Microscope
Introduction to Digital Photography and Microscopy
Some Factors Involved in Obtaining and Using Good Photomicrographs
The Digital Image Formation Chain
Selection of Digital Cameras
Camera mounts
Camera Settings
  Automatic Settings
  Image print size
  Manual setting mode
Focusing tips for Digital Cameras
Take some test photos
Getting your photos from camera to the computer
  Simple method - flash card
  Manufacturer's cables
  Video bus
Building and Organizing a Digital Photo Library on a computer
  Photo library management
  Photo Library design
  First Pass Screening
  Saccardo Method
Image Library Backup Suggestions
References for Digital Photography

MICROSCOPE SLIDE PREPARATION
  Slide Preparation Procedure
  Slide Stain & Media Recipes
  Permanent Slide Mounts
  Gelvatol
  Meltmount
  Mowiol
  The Stains File

MICROSCOPE SLIDE PREP - PERMANENT MOUNTS
  Required materials
  To use meltmount slides

MILDEW in buildings ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOISTURE CONTROL in buildings

MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD ACTIVITY in buildings
MOLD AGE - Old is the Mold?

MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD ATLAS & PARTICLES INDEX

MOLD by MICROSCOPE
MOLD in the PETRI DISH, PHOTOS
Mold on Books, Book Conservation

MOLD CLASSES, HAZARD LEVELS

MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP - BLEACH
MOLD CLEANUP - HEALTH RISKS
MOLD CLEANUP - LIMITATIONS
MOLD CLEANUP - MISTAKES to AVOID
MOLD CLEANUP - MEDIA BLASTING
MOLD CLEANUP - SAFETY WARNINGS
MOLD CLEANUP - WOOD FLOORING
MOLD CLEANUP - WOOD FRAMING & PLYWOOD

MOLD CLEARANCE INSPECTIONS
MOLD CLEARANCE: FOLLOWUP STEPS

MOLD CLINICAL REFERENCE TEXTS

MOLD CONSULTANTS/INSPECTORS

MOLD CONTAMINATION LEVELS

MOLD CULTURE PHOTOS
MOLD CULTURE TEST KIT VALIDITY
MOLD CULTURE SAMPLING METHOD

MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTORS - ENVIRONMENTAL MEDICINE

MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE, FOOD HAZARDS
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS

MOLD FAQ's
MOLD FREQUENCY in buildings
MOLD GROWTH ON SURFACES, PHOTOS
MOLD GROWTH on SURFACES, TABLE OF
MOLD GROWTH in/on BUILDING INSULATION

MOLD INFORMATION CENTER
MOLD INSPECTORS & MOLD TESTERS
MOLD INSPECTION SERVICE
MOLD INVESTIGATION PROCEDURE TIPS
MOLD INVESTIGATION REPORTS

MOLD KILLING GUIDE
MOLD LAB REPORTS

MOLD LEVEL IN AIR, VALIDITY
MOLD LEVEL REPORTS
MOLD LEVELS IN buildings
MOLD by MICROSCOPE
MOLD ODORS, MUSTY SMELLS
MOLD on or in CARPETS
MOLD ON DIRT FLOORS

MOLD PREVENTION GUIDE

MOLD RELATED ILLNESS GUIDE
MOLD RELATED ILLNESS SYMPTOMS
MOLD RESISTANT CONSTRUCTION

MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS

MOLD STANDARDS
MOLD STANDARDS - GOVERNMENT
MOLD STANDARDS - WORLD WIDE

MOLD TOXICITY VARIATION

MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES

MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE

OZONE for MOLD OR ODORS

PAINT ANALYSIS, DIAGNOSTIC USES
PAINT & STAIN GUIDE, EXTERIOR
PAINT FALURE, DIAGNOSIS, CURE, PREVENTION
PAINT FAILURE CHECKLIST
PAINTING MISTAKES
PAINT FAILURE DICTIONARY
PAINT FAILURE ANALYSIS LAB PHOTOS
Paint Failure Case Photographs-SITE
Paint Failure Case Photographs-LAB
PAINT LAB SAMPLE PREPARATION
PAINT SURFACE PREPARATION

Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
POLLEN Photographs

RENTERS & TENANTS GUIDE TO MOLD
ROBIGUS & Wheat Rust Fungus
ROT, TIMBER FRAME

SLIDE PREPARATION, MICROSCOPE

SMELL PATCH TEST to Track Down Odors

SOUND CONTROL in buildings

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAINS & Thermal Tracking

TECHNICAL & LAB PROCEDURES
THERMAL TRACKING Indicates Heat Loss
TRAPPED MOLD BETWEEN WOOD SURFACES

VAPOR BARRIERS & CONDENSATION in buildings
VENTILATION in buildings

WALL SIDING TRIM & FINISHES
WALL FINISHES INTERIOR

WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in buildings
WATER ODORS, CAUSE CURE
World Trade Center Collapse Dust Photos

More Information

Photograph of Aspergillus sp. conidiophores at 1200x, lacto phenol cotton blue stain .

Focusing Tips for Digital Photography at the Microscope
InspectAPedia®  -    

  • How to focus a digital camera to take sharp photographs through the microscope
  • Recommendations for digital cameras, adapters, photograph organizing software for microscope digital photography
  • Recommended camera adjustments and settings for use with a microscope
  • Questions & answers about obtaining sharp focused microphotographs

Microphotography - how to focus the digital camera through the microscope: how to obtain sharp, in-focus photographs through the microscope using a low-cost digital camera. The purpose of this paper is to help microscopists photograph, store, and use digital microphotographs using modern digital cameras and transmitted-light microscopes.

InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

Photograph of a stereo microscope combined with a Nikon Coolpix 9500 digital camera

Discussion focuses on selection of cameras adapt well to microscope eyepieces or trinocular heads, and on camera settings and procedures to obtain best quality photographs. We also discuss image resolution and size settings and make recommendations. Cameras used as examples in this paper include the Nikon Coolpix series 990, 995, and 4500.

[The photograph at page very top is one of our earliest attempts at photographing Aspergillus sp. using lacto phenol cotton blue stain. Even a beginner can obtain very good microphotographs with just a little care. The photograph shown here is of one of our stereoscopic microscopes in use for making digital photographs.

The techniques discussed in this paper work well with digital cameras and any type of microscope, low power stereo zoom to high power forensic polarized light microscopes.]

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

PAAA 2005 Symposium, University of Tulsa, Tulsa Oklahoma - June 2-5, 2005 - updated 02/23/2009
Note: the latest version of this document can be found at InspectAPedia.com/mold/digipix.htm
last update 20 August 2007 © Daniel Friedman All Rights Reserved

Focusing tips for digital photography at the microscope

Hold the camera dead still against the eyepiece while shooting; the rim of the camera lens should press against your eyepiece sides, so you're not scratching anyone's lens. Or use a standard lens mount that replaces the eyepiece, or use a microscope with a trinocular head and mount your camera there.

  • On our forensic microscope we mount the camera on the trinocular head and we add a Nikon MC-EU1 remote control which connects to the camera by a cable and permits us to take photos using a button on the desktop, avoiding touching the camera at all for least disturbance. However this device is not really necessary. This may be the only instance where the shutter delay on older digital cameras is an advantage. Simply press the shutter button and then remove your hands from the camera, giving it time to settle down before the shutter activates.
  • If you're not getting a sharp photo the camera may be auto-focusing on a different part of the image.
  • Be sure the object of interest is located in the center of the viewing area or use the camera's optional "manual focus" mode to select which area of the field is to be focused-upon.
  • If you find the camera just can't get a clear photo no matter what, it might be that the image of interest lacks sufficient points of contrast (lines work best) for the camera to "see" what to focus upon.
  • Try turning off the camera's auto-focus by setting it to focus at infinity. Then with the camera turned on, adjust the microscope stage up or down for the sharpest image shown on the camera LCD screen. You can improve your performance doing this by zooming in on the camera during focusing, then zooming out to get the image you want.
  • For example shooting Periconia if you focus the microscope on the warty surface the edges of the spore will be blurred and it may take several tries at 100x to get a good shot. If you re-focus the microscope to show the sharp edges of the spore you'll see the camera hesitates much less before deciding it's got the image in focus.
  • Try several shots, review on the camera screen, then load into your PC for really better examination.

Take some test photos through the microscope

Focus your microscope on your slide for best image Try shooting first through the eyepiece that has a reticule or other scale - you'll see the camera sometimes focuses on the scale rather than the image but at times, if the particle is close to the scale in depth this gives sharp results;

Try now shooting the same image through the other eyepiece - one with no scale mounted in it - forces camera to focus on the particle - which we put in the center of the field. Also we set this eyepiece on our microscope to "0" image adjustment since we think the camera would not prefer to have to focus through the correction we otherwise set for our own eye.

Test Images for evaluating image resolution: you may already have images on file suitable for this purpose. we use slides of diatoms or radiolarians - particles which have very fine detail and sharp edges. One can also purchase slides specially prepared for this purpose (but they are expensive.) we tried using our stage micrometer but other images have finer detail.

Questions & Answers regarding this article

Questions & answers about obtaining sharp focused microphotographs

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Digital Photography & the Microscope
Introduction to Digital Photography and Microscopy
Some Factors Involved in Obtaining and Using Good Photomicrographs
The Digital Image Formation Chain
Selection of Digital Cameras
Camera mounts
Camera Settings
  Automatic Settings
  Image print size
  Manual setting mode
Focusing tips for Digital Cameras
Take some test photos

Getting your photos from camera to the computer
  Simple method - flash card
  Manufacturer's cables
  Video bus

Building and Organizing a Digital Photo Library on a computer
  Photo library management
  Photo Library design
  First Pass Screening
  Saccardo Method

Image Library Backup Suggestions
References for Digital Photography

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Aerobiology, Building Science, Microscopy, & Laboratory References, an extensive technical bibliography
  • Atlas of Clinical Fungi, 2nd Ed., GS deHoog, J Guarro, J Gene, & MJ Figueras, Centraalbureau voor Schimmelcultures, Universitat Rovira I Virgili, 2000, ISBN 90-70351-43-9
  • Atlas of Mold Related Illness: Index of Symptoms and health, physical, neurological, psychological, and other complaint which people suspect may be mold or building-related.
  • Atlas of Indoor Mold, Online Clinical Mold Atlas, Toxins, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • Building Floods: quick steps after a building flood or plumbing leak can prevent costly mold contamination
  • Classes of Mold: what types of cosmetic, allergenic, or toxic mold are a problem? Can mold be cleaned-up successfully?
  • Clinical Mold References - Detailed bibliography of mold reference texts
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • "Disease Prevention Program for Certain Vegetable Crops," David B. Langston, Jr., Extension Plant Pathologist - Vegetables, University of Georgia (PDF document) original source: www.reeis.usda.gov/web/crisprojectpages/209797.html
  • "Disease Prevention in Home Vegetable Gardens," Patricia Donald, Department of Plant Microbiology and Pathology, Lewis Jett
    Department of Horticulture, University of Missouri Extension - extension.missouri.edu/publications/DisplayPub.aspx?P=G6202
  • "Management of Powdery Mildew, Leveillula taurica, in Greenhouse Peppers," Ministry of Agriculture and Lands, British Columbia - Original source: www.agf.gov.bc.ca/cropprot/peppermildew.htm
  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Fifth Kingdom, Bryce Kendrick, ISBN13: 9781585100224, is available from the InspectAPedia online bookstore - we recommend the CD-ROM version of this book. This 3rd/edition is a compact but comprehensive encyclopedia of all things mycological. Every aspect of the fungi, from aflatoxin to zppspores, with an accessible blend of verve and wit. The 24 chapters are filled with up-to-date information of classification, yeast, lichens, spore dispersal, allergies, ecology, genetics, plant pathology, predatory fungi, biological control, mutualistic symbioses with animals and plants, fungi as food, food spoilage and mycotoxins.
  • Fungi, Identifying Filamentous, A Clinical Laboratory Handbook, Guy St-Germain, Richard Summerbell, Star Publishing, 1996, ISBN 0-89863-177-7 (English)
  • Mold Action Guide: Step-by-Step Instructions, What to do about mold, mildew, and other indoor allergens
  • US EPA: Mold Remediation in Schools and Commercial Building US EPA
  • US EPA: Una Breva Guia a Moho - Hongo - en Espanol
  • Most Common Indoor Molds Found in buildings, A Table of
  • Mycology, Fundamentals of Diagnostic, Fran Fisher, Norma B. Cook, W.B. Saunders Co. 1998, ISBN 0-7216-5006-6
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com