InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US

Mobile viewMobile View
OIL STORAGE TANKS

ABANDONING OIL TANKS
ABOVE GROUND OIL TANK INSPECTIONS
AFUE DEFINITION, RATINGS
AGE of OIL TANK
ANODES & DIP TUBES on WATER HEATERS

BIOGAS PRODUCTION & USE
BOILERS, HEATING

BURIED OIL TANK ADVICE
BURIED OIL TANKS, FINDING

COMBUSTION PRODUCTS & IAQ

DEFINITION of Heating & Cooling Terms
DIAGNOSE & FIX HEATING PROBLEMS-BOILER
DIAGNOSE & FIX HEATING PROBLEMS-FURNACE

FILTERS, OIL on HEATING EQUIPMENT
FIRE SAFETY CONTROLS
FLAME COLOR, BLUE vs YELLOW COMBUSTION
FLOATING UP OIL STORAGE or SEPTIC TANKS
FLOODED HEATING EQUIPMENT REPAIR
FLOODED WATER HEATER REPAIR
FUEL OIL TYPES & CHARACTERISTICS
FUEL UNIT, HEAING OIL PUMPS

GALVANIC SCALE & METAL CORROSION
GAUGES ON HEATING EQUIPMENT

HEAT LOSS in buildings
HEAT TAPES, Heat, Insulation prevent Freeze-Up

HEATING COST FUEL & BTU Cost Table
HEATING COST SAVINGS METHODS

HEATING OIL CLOUD WAX GEL POINT
HEATING OIL EXPOSURE HAZARDS, LIMITS
HEATING OIL - OLD, USEABLE?
HEATING OIL PIPING TROUBLES
HEATING OIL SHELF LIFE
HEATING OIL SLUDGE
HEATING OIL TANKS
HEATING OIL USAGE RATE

HEATING SYSTEM INSPECT DIAGNOSE REPAIR
HEATING SYSTEM NOISES

HOME BUYERS GUIDE TO OIL TANKS
HOT WATER HEATERS

NO HEAT - BOILER / FURNACE DIAGNOSIS
NOISE CONTROL for HEATING SYSTEMS
NOISES COMING FROM WATER HEATER

ODORS & SMELLS DIAGNOSIS & CURE
ODORS FROM HEATING SYSTEMS

OIL BURNERS
OIL BURNER INSPECTION GUIDE
OIL BURNER NOISE SMOKE ODORS
OIL BURNER SOOT & PUFFBACKS

OIL FILTERS on HEATING EQUIPMENT
OIL FILTER MISSING
OIL FUEL TYPES & CHARACTERISTICS

OIL LINE CLOGGING FIX
OIL LINE SAFETY VALVES
OIL ODORS, LEAKY OIL TANK PIPING
OIL PUMP FUEL UNIT

OIL SPILL CLEANUP / PREVENTION

OIL TANKS
OIL TANK ABANDONING PROCEDURE
OIL TANK AGE
OIL TANK, BURIED, ADVICE
OIL TANK, BURIED, FINDING

OIL TANK FAILURE CAUSES
OIL TANK FAILURE RATES
OIL TANK FLOATING UP

OIL TANK GAUGES
OIL TANK INSPECTION, ABOVE GROUND
OIL TANK INSPECTION REPORTS

OIL TANK LEAKS & SMELLS
  OIL TANK LEAK ENVIRONMENTAL ISSUES
  FREQUENCY of OIL TANK LEAKS
  HOME INSPECTOR OIL TANK REPORT
  OIL TANK LEAK IMPACTS
  OIL TANK LEAK CAUSES
  OIL TANK LEAK CLEANUP GUIDE
  OIL TANK LEAK REPORTING REGULATIONS - ALL
  OIL TANK REGULATIONS - CANADA
  OIL TANK LEAK REPORTING in NEW JERSEY
  OIL TANK LEAK & SIZE REPORTING REQUIREMENTS
  OIL TANK LEAK TESTING
  LEAKY OIL TANK FILL PIPES
  OIL TANK LEAK REPORTING BASICS
  WHAT IF AN OIL TANK IS LEAKING?

OIL TANK LEGAL ISSUES
OIL TANK LIFE

OIL TANK PIPING & PIPING DEFECTS
OIL TANK PRESSURE

OIL TANK REGULATIONS
  BULK STORAGE OF PETROLEUM PRODUCTS
  OIL TANK LEAK REPORTING BASICS
  OIL TANK LEAK REPORTING REGULATIONS - ALL
  OIL TANK LEAK REPORTING, NEW JERSEY
  OIL TANK LEAK & SIZE REPORTING REQUIREMENTS
  OIL TANK LEGAL ISSUES
  OIL TANK REGULATIONS - CANADA
  OIL TANK LEAK & SIZE REPORTING REQUIREMENTS
OIL TANK REMOVAL COs
OIL TANK REMOVAL FINANCIAL AID
OIL TANK REPORT LANGUAGE

OIL TANK SAFETY
OIL TANK SLUDGE
OIL TANK STANDARDS
OIL TANK STANDARDS - Detailed List
OIL TANK SPILL CLEANUP / PREVENTION
OIL TANK SUPPORT

OIL TANK TESTING
  Mesa 2-D TEST for OIL TANK LEAKS
  PRESSURE TESTING OIL TANKS
  SOIL TESTING FOR OIL TANK LEAKS
  STANDARDS FOR TANK TESTING
  ULTRASOUND TEST for AST OIL TANKS
  WATER in OIL TANKS, TEST FOR
OIL TANK TESTING COs

OIL TANK WATER CONTAMINATION
OIL TANK WATER REMOVAL

SOOT on OIL FIRED HEATING EQUIPMENT

STAIN DIAGNOSIS on BUILDING INTERIORS

WATER HEATERS

More Information

Heating Oil Underground & Above ground Oil Storage Tank Home Buyer's / Home Owner's Guide
- Oil Storage Tank Leak Testing Options and Test Companies
InspectAPedia®  -         

  • What types of oil storage tank leak tests are available
  • What are the pros and cons of alterative methods of testing for oil tank leaks?
  • Questions & answers about choosing among oil tank leak testing methods

Guide to types of oil storage tank leak tests available: this article discusses the types of oil storage tank tests that may be performed on buried oil tanks and above ground oil storage tanks to check for leaks or imminent leaks.

InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

Not all storage tank tests are equal in accuracy nor cost, and some are more appropriate than others, depending on other factors.

We include a listing of oil and fuel storage tank testing companies and services, and invite (no-fee) listings from other companies providing that service. Many storage tank testing companies also offer storage tank removal and site cleanup services as well. This is a chapter of our "Heating Oil Underground & Above ground Oil Storage Tank Leaks, Testing, Problems & Solutions, Home Buyer's / Home Owner's Guide" which offers extensive free un-biased oil storage tank inspection and testing advice for property buyers and owners. Qualified service providers may be listed at this website at no fee.

Home buyers should be sure to review OIL TANK TESTING - Leaky Heating Oil Tanks - How Oil Tanks are Tested for Evidence Leaks, of Current or Previous Oil Spills andOIL TANK LEGAL ISSUES - Home Buyers and Home Owners Guide to Leaky Heating Oil Tanks - What to Do About & When to Report Oil Tank Leaks. Leaky Heating Oil Tanks.

Home owners who have old oil tanks above ground or any age oil tank below ground should also be sure to review OIL TANK ABANDONING PROCEDURE - Abandoning Commercial vs. Residential Underground Oil Storage Tanks (UST) - Procedures & Regulations A separate website addresses Septic Tanks.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

TANK TESTING - Oil Tank Inspection and Oil Leak Testing Choices

Look for yourself: Before deciding to hire a tank testing company for professional inspection and testing, some basic information such as the age (property and tank), tank location, and type of oil tank, and for above-ground tanks, a simple visual inspection of the tank and its piping, can give you and idea of the risks involved. Look for obvious leaks such as oil stains on the ground or floor under or around the tank and around the oil fired equipment. Remember to look under the oil tank at its bottom, as most leaks occur in the lower portion of the tank.

Hire an expert: Specialty companies and some oil companies have equipment to test buried tanks for leaks. Soil testing, simple low-psi pressure-testing and sophisticated electronic testing are commonly used. I advise home buyers to have a soil test performed rather than a pressure test of an existing oil tank, since even if the tank is not currently leaking we would prefer an assurance that it didn't leak before, say from a plumbing connection that was repaired.

In addition to oil tank inspection, oil piping inspection, and oil tank testing to "pass" or "fail" an oil storage tank, more sophisticated tests are available to assess the chances that an existing heating oil storage tank has leaked or is likely to have a serious leak soon. These include a oil tank corrosion analysis which adds to the basic tank inspection and tests an assessment of the level of corrosion of the tank walls and thus the chances of its leaking or failure, and soil corrosion or soil corrosivity evaluation which includes an evaluation of soil samples collected from around the tank in order to assess the degree to which the soil in which the oil tank has been buried will contribute to the process of corrosion of the (presumably steel) buried oil tank.

Testing for water in an oil tank (above ground or buried) is simple and can be done by any service person. Tank testing methods vary in risk to the tank, cost, invasiveness, length of time to complete, and more.

From a previous use, a buried oil tank may be present or may have been present at a property now served by an indoor, above ground oil tank or even by LP or natural gas. So don't assume that because you don't see a tank that none was ever used or present at a property.

OIL TANK LEAK TESTING COs / OIL TANK REMOVAL COs - Oil Tank Testing, Removal, Consulting Environmental Service Companies

  • CT: Enviro Tech of Fairfield County oil tank testing and locating services, Connecticut
  • CO: Tank Specialists, Far West Assoc, Colorado, Wyoming, S. Nevada, S., Baja CA
  • NY: Dorson Environmental Management, Inc., 45 Knollwood Rd., 3rd Fl., Elmsford NY 10523: 914-592-3117
  • OH: CTL Engineering, Inc., Columbus OH (HQ) - UST Management, Testing, Inspection, Analysis: 614-276-8123 614-276-6377 FAX.
    ctl@ctleng.com Offices in NC, OH, WV, VA [Thanks for website support]
  • NY-Nationwide Hodgens Engineering Service, 800-463-4367 Jay Hodgens, james@hodgens.net EPA Compliance and SPCC Planning Specialist www.hodgens.net/hes/spcc.php (Also offers radon testing using a continuous working level monitor)
  • VA: Virginia Geotechnical Services, P.C. Email: W. Jerrold Samford, P.G.
  • Mediation, Environmental Dispute - KMG
  • Disposal, Hazardous Waste, SET Home Pg
  • Sound Pictures of Stored Waste
  • Tank / other Env Services Braun-Intertec (C)trap
  • Tank / other Env Services ENSCI Southeast US (C)trap
  • Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Questions & Answers regarding this article

Questions & answers about choosing among oil tank leak testing methods

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • TANK FAILURE CAUSES discusses the causes of oil storage tank leaks in more detail.
  • The rate or frequency of oil tank leaks or oil storage tank failures, focused on underground storage tanks or USTs, is discussed in detail at TANK FAILURE RATES provides Oil Tank Failure Data - Oil Tank Failure Rates - Oil Tank Leak Probability as a Function of Tank Age, Location, Condition, Soil Conditions and Other Factors

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

OIL TANK LEAKS & SMELLS
  OIL TANK LEAK ENVIRONMENTAL ISSUES
  FREQUENCY of OIL TANK LEAKS
  HOME INSPECTOR OIL TANK REPORT
  OIL TANK LEAK IMPACTS
  OIL TANK LEAK CAUSES
  OIL TANK LEAK CLEANUP GUIDE
  OIL TANK LEAK REPORTING REGULATIONS - ALL
  OIL TANK REGULATIONS - CANADA
  OIL TANK LEAK TESTING
  LEAKY OIL TANK FILL PIPES
  OIL TANK LEAK REPORTING BASICS
  WHAT IF AN OIL TANK IS LEAKING?

Listing submissions welcome, there is no listing fee. InspectAPedia.com - Directory Listing & Link Exchange Instructions. Add your listing & support InspectAPedia.com by exchanging links - no listing fee & no conflicts of interest.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com