| InspectAPedia® |
InspectAPedia
| |
Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair | Ask a Question or Search InspectAPedia |
Mobile ViewHEATING SYSTEMS AFUE DEFINITION, RATINGS AGE of AIR CONDITIONERS & HEAT PUMPS AGE of HEATERS, BOILERS, FURNACES AGE of WATER HEATERS AIR CONDITIONING & HEAT PUMP SYSTEMS AIR FILTERS for HVAC SYSTEMS ANODES & DIP TUBES on WATER HEATERS AIR HANDLER / BLOWER UNITS AIRBOUND HEAT SYSTEM REPAIRS ANODES & DIP TUBES on WATER HEATERS ANTI SCALD VALVES APPLIANCE EFFICIENCY RATINGS ASBESTOS IDENTIFICATION IN buildings BACKDRAFTING HEATING EQUIPMENT BACKFLOW PREVENTER VALVE, HEATING SYS BACKFLOW PREVENTER, HEATER WATER FEEDER BACKUP HEAT for HEAT PUMPS BANGING HEATING PIPES RADIATORS BAROMETRIC DAMPERS BASEBOARD HEAT BIOGAS PRODUCTION & USE BLEVE EXPLOSIONS BLOWER DOORS & AIR INFILTRATION BLOWER FAN CONTINUOUS OPERATION BLOWER FAN OPERATION & TESTING BLUE vs YELLOW COMBUSTION FLAMES BLUERAY Recall BOILERS, HEATING BOILER LEAKS CORROSION STAINS BOILER LEAKS, HOW TO LOCATE BOILER NOISE SMOKE ODORS BOILER OPERATING PROBLEMS BOILER OPERATION DETAILS BOILER PRESSURE & TEMPERATURE SETTINGS BOOKSTORE - InspectAPedia BUILDING SAFETY HAZARDS GUIDE CAPACITORS for HARD STARTING MOTORS CARBON DIOXIDE - CO2 CARBON MONOXIDE - CO CARBON MONOXIDE WARNING CHIMNEY INSPECTION DIAGNOSIS REPAIR CHIMNEYS & Flues - Asbestos Transite Pipe CHINESE DRYWALL HAZARDS CIRCULATOR PUMPS & RELAYS COOL OFF HEAT, Thermostat Switch COMBUSTION AIR COMBUSTION AIR for TIGHT buildings COMBUSTION GASES & PARTICLE HAZARDS COMBUSTION PRODUCTS & IAQ COMPLETE COMBUSTION, Stoichiometric CONDENSING BOILERS/FURNACES CONDENSING BOILERS/FURNACES DAMAGE CONVECTOR HEATERS - HYDRONIC COILS CREOSOTE FIRE HAZARDS DEFINITION of Heating & Cooling Terms DIAGNOSE & FIX AIR CONDITIONER / HEAT PUMP DIAGNOSE & FIX HEATING PROBLEMS-BOILER DIAGNOSE & FIX HEATING PROBLEMS-FURNACE DIRECT VENTS / SIDE WALL VENTS DIRECTORY of OIL TANK EXPERTS DRAFT HOODS - gas fired DRAFT MEASUREMENT, CHIMNEYS & FLUES DRAFT REGULATORS, DAMPERS, BOOSTERS DUCT SYSTEM & DUCT DEFECTS DUST CONTAMINATION FROM HVAC? ELECTRIC HEAT, DIAGNOSIS, REPAIR ELECTRIC MOTOR DIAGNOSTIC GUIDE ELECTRIC MOTOR OVERLOAD RESET SWITCH ELECTRICAL POWER SWITCH FOR HEAT EVAPORATIVE COOLING SYSTEMS FAN, AIR HANDLER BLOWER UNIT FAN AUTO ON Thermostat Switch FAN, COMPRESSOR/CONDENSER UNIT FAN CONVECTOR HEATERS - HYDRONIC COILS FAN LIMIT SWITCH FAN NOISES FILTERS, AIR for HVAC SYSTEMS FILTERS, OIL on HEATING EQUIPMENT FIRE SAFETY CONTROLS FIREPLACES & HEARTHS FLAME COLOR, BLUE vs YELLOW COMBUSTION FLOODED HEATING EQUIPMENT REPAIR FLUE VENT CONNECTORS FREEZE-PROOF A BUILDING FUEL OIL TYPES & CHARACTERISTICS FUEL UNIT, HEATING OIL PUMPS FURNACES, HEATING FURNACE CONTROLS & SWITCHES FURNACE EFFICIENCY, HIGH vs MID FURNACE HEAT EXCHANGER LEAKS FURNACE OPERATION DETAILS FURNACE OPERATING TEMPERATURES GALVANIC SCALE & METAL CORROSION GAS BURNER Flame & Noise Defects GAS DETECTION & MEASUREMENT Drager gas sampling pump Colorimetric gas detection tubes GAUGE, REFRIGERATION PRESSURE TEST TIF 5000 Gas Detector TIF 8800 Gas Detector Warnings: gas detectors Warning: gas detector tubes GAS EXPOSURE EFFECTS, TOXIC GAS EXPOSURE LIMITS & STANDARDS GAS EXPOSURE TEST PROCEDURES GAS FIRED WATER HEATERS GAS LP & Natural Gas Safety Hazards GAS LP & Natural Gas Pressures GAS PIPING, VALVES, CONTROLS Gas BTUH & Cubic Feet Gas Conversion LP Natural Gas Gas Flame & Noise Defects Gas Igniter Defects, Repairs Gas Leak Detection Gas Lighting Pipes & Fixtures Gas Meters Gas Piping Defects Gas Regulators for Appliances Gas Regulators for LP Tanks Gas Regulators, Two Stage Gas Shutoff Valves LP Gas Tanks LP & Natural Gas Safety Hazards LP & Natural Gas Pressures METHANE GAS SOURCES Natural Gas Combustion Products Types of Fuel Gas Source GAUGES ON HEATING EQUIPMENT GEOTHERMAL HEATING SYSTEMS HEAT EXCHANGER LEAKS HEAT LOSS in buildings HEAT LOSS DETECTION TOOLS HEAT LOSS INDICATORS HEAT LOSS PREVENTION PRIORITIES HEAT LOSS R U & K VALUE CALCULATION HEAT PUMPS, DiAGNOSIS, REPAIR HEAT TAPES & CABLES on Roofs for Ice Dams HEATING COST FUEL & BTU Cost Table HEATING COST SAVINGS METHODS HEATING LOSS DIAGNOSIS-BOILERS HEATING LOSS DIAGNOSIS-FURNACES HEATING OIL TANKS HEATING SMALL LOADS HEATING SYSTEM INSPECT DIAGNOSE REPAIR HEATING SYSTEM NOISES HEATING SYSTEM SERVICE & MAINTENANCE HEATING SYSTEM TYPES HIGH EFFICIENCY BOILERS/FURNACES HOT WATER HEATERS HOT WATER IMPROVEMENT HUMIDITY LEVEL TARGET ICE DAM PREVENTION INSULATION INSPECTION & IMPROVEMENT LP & Natural Gas Safety Hazards MANUALS & PARTS GUIDES - HVAC METHANE GAS SOURCES MIXING / ANTI-SCALD VALVES MIX VALVE SCALD PROTECTION, Best Practices MOTOR OVERLOAD RESET SWITCH Natural Gas Combustion Products NO HEAT - BOILER NO HEAT - FURNACE NOISE / SOUND DIAGNOSIS & CURE NOISE CONTROL for HEATING SYSTEMS NOISE CONTROL for PLUMBING NOISES COMING FROM WATER HEATER ODORS & SMELLS DIAGNOSIS & CURE ODORS FROM HEATING SYSTEMS OIL BURNERS OIL FILTERS on HEATING EQUIPMENT OIL FILTER MISSING OIL FUEL TYPES & CHARACTERISTICS OIL & GAS PIPING OIL LINE CLOGGING FIX OIL LINE QUICK STOP VALVES OIL LINE SAFETY VALVES OIL ODORS, LEAKY OIL TANK PIPING OIL PUMP FUEL UNIT OIL SPILL CLEANUP / PREVENTION OIL TANKS PLASTIC HEATER VENT PULSE COMBUSTION HEATERS PASCAL CALCULATIONS RADIANT BARRIERS RADIANT HEAT RADIANT HEAT Floor Mistakes to Avoid RADIANT HEAT TEMPERATURES RADIANT SLAB FLOORING CHOICES RADIANT SLAB TUBING & FLUID CHOICES RADIATORS RELIEF VALVES - TP Valves on Boilers RELIEF VALVES - STEAM TP VALVES RELIEF VALVES - Water Heaters RELIEF VALVES - Water Tanks Reset Switch - Heater Primary Control Reset Switch Broken - Quick Repair Reset Switch - Electric Motors Reset Switch - Stack Relays SAFETY HAZARDS & INSPECTIONS SAFETY HAZARDS GUIDE SAFETY, HEATING INSPECTION SAFETY,HOME HEATING TIPS Safety Recalls, Chimneys, Vents, Heaters SOLAR HEATING SYSTEM DESIGNS SOLAR HOT WATER HEATERS SOOT on OIL FIRED HEATING EQUIPMENT SPILL SWITCHES - Flue Gas Detection SPLIT SYSTEM AIR CONDITIONERS & HEAT PUMPS STACK RELAY SWITCHES STAIN DIAGNOSIS on BUILDING INTERIORS STEAM HEATING SYSTEMS TANKLESS COILS THERMAL EXPANSION of MATERIALS THERMAL MASS in buildings THERMAL TRACKING & HEAT LOSS THERMOSTATS, HEATING / COOLING Transite Pipe Chimneys & Flues VIDEO GUIDES: Heating System Videos VIDEO GUIDES - InspectAPedia.com WATER HEATERS WATER HEATER SAFETY WATER HEATERS for HOME HEATING USE? WATER HEATER NOISES WATER HEATER SCALE - De-Liming Procedure WATER HEATER SCALE PREVENTION WATER SOFTENERS & CONDITIONERS WINTERIZE A BUILDING WOOD, COAL STOVES & FIREPLACES WOOD STOVE SAFETY More Information |
LP or natural gas regulator requirements: this article explains why, when, and where a two-stage gas regulator system is recommended at a building. Our page top photo shows a a large, remote, and centralized outdoor LP gas storage tank serving multiple homes in a small community in New York. A second LP gas regulator was required at individual buildings. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.
© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Recommendations for use of two-stage gas regulationIn this article series we provide descriptions and photographs of unsafe gas piping, regulators, or controls on heating systems, indications of unsafe or improperly operating gas appliances, gas meters, and other gas installation defects. This document also provides free sample draft home inspection report language for reporting defects in oil and gas piping at residential properties. Gas Cylinder or Tank Regulators: Readers concerned with installing, inspecting, or testing LP Gas regulators which are found on outdoor above ground or buried gas cylinders used for storage of LP Gas on site should also see How to Inspect & Test LP Gas Tank or Cylinder Regulators. Readers concerned with changing the fuel type between LP gas and natural gas for a gas fired appliance should see our safety warnings at Gas Conversion LP Natural Gas. General safety warning: improper installation and even improper inspection and testing methods involving natural or "LP" gas can involve dangerous conditions and risk fire or explosion. If you smell gas you should leave the building immediately and should do so without doing anything that could create a spark such as operating a light switch or telephone. From a safe location, call your gas company's emergency line and/or your fire department. The text provided here is a working draft and may be incomplete or inaccurate. Many residential LP gas installations will be found with a single gas pressure regulator at the storage tank. A "two stage" LP gas regulation system uses two gas pressure regulators. Gas flows out of the LP Gas storage tank first through a "high pressure" regulation stage (usually installed right at the LP gas tank) and then through a second "low pressure" regulator as a second stage (usually installed close to the point of LP gas entry into the building). Two stage LP gas regulation is required for certain installations but is less often found installed at single family residential properties. Experts recommend this "two-stage" regulation of LP gas installations, particularly where large LP tanks are installed above or below ground for several reasons:
Actual NG or LPG gas pressures vary: [Note: the exact pressure you see in the building at an appliance may vary from these numbers depending on the gas distribution piping system size, diameter, number of appliances served, number of appliances operating, regulator adjustment, and other factors. See Gas Regulators for Appliances and Gas Regulators for LP Tanks. See LP or Natural Gas Pressures for a table showing the range of variation in LP gas pressure in the tank at various temperatures. - Ed.] Questions & Answers regarding this article. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
Recommend / Share this Article
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. GAS PIPING, VALVES, CONTROLS
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
|