ate

 

InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile Phone/PDA website viewMobile View
STRUCTURAL INSPECTIONS & DEFECTS

ADVANCED INSPECTION METHODS
AGE of a BUILDING - how to determine
AGE of CHIMNEYS & FIREPLACES
AGE of CESSPOOL
AGE of AIR CONDITIONERS & HEAT PUMPS
AGE of FOUNDATION MATERIALS
AGE of FRAMING MATERIALS
AGE of FRAMING METHODS
AGE of FLOORING MATERIALS
AGE of ELECTRICAL WIRING
AGE of HEATERS, BOILERS, FURNACES
AGE of PLUMBING MATERIALS & FIXTURES
AGE of ROOFING STYLE, MATERIALS
AGE of SEPTIC SYSTEM
AGE of SEPTIC DRAINFIELD
AGE of SIDING MATERIALS
AGE of WATER HEATERS
AGE of INDOWS & DOORS

ARCHITECTURE & BUILDING COMPONENT ID
  Architectural Styles - Illustrated Guide
  ARCHITECTURE, STYLE, & Building Age
  Architecture Dictionary of buildings, Components
  Building Age & Architectural Style
  Chimney Architectural Styles - Photo Guide
  KIT HOMES, Aladdin, Sears, Wards, Others
  Mobile Homes, Modulars, Panelized, & Factory-Built
  Roofs & Architectural Styles - Photo Guide
  Roof Dormer Types - Photo Guide
  Siding, Sheathing Identification - Photo Guide
  Window Types - Photo Guide

ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS ROOFING / SIDING DUST
ATTIC LEAKS, CONDENSATION & ATTIC MOLD

BASEMENT HEAT LOSS
BASEMENT LEAKS, INSPECT FOR

BATH & KITCHEN DESIGN GUIDE
BATHROOM VENTILATION
BEST CONSTRUCTION PRACTICES GUIDE

BOOKSTORE - INTERIORS

BRICK LINED WALLS
BRICK VENEER WALL INSULATION
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES

BUILDING NOISE DIAGNOSIS & CURE

CABINETS & COUNTERTOPS

CARPET PADDING ASBESTOS, MOLD, ODORS
CARPET STAIN DIAGNOSIS
CARPETING, SELECTION & INSTALLATION

CASEWORK, CABINETS, SHELVING INSTALLATION

CATHEDRAL CEILING INSULATION
CATHEDRAL CEILING VENTILATION
CEILING FINISHES INTERIOR
CEILINGS, DROP or SUSPENDED PANEL
CEILINGS, PLASTER TYPES
CEILING TILES - Asbestos-Containing

CHIMNEY INSPECTION DIAGNOSIS & REPAIR
CHINESE DRYWALL HAZARDS

CONDENSATION or SWEATING PIPES, TANKS
CONDENSATION on WINDOWS & SKYLIGHTS

CHIMNEY INSPECTION DIAGNOSIS & REPAIR

DOORS, INTERIOR

ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR
  KNOB & TUBE WIRING

FLOOR TYPES & DEFECTS
FLOOR TILE ASBESTOS IDENTIFICATION
FLOOR TILE HISTORY & INGREDIENTS

HEATING SYSTEMS
  AGE of AIR CONDITIONERS & HEAT PUMPS
  AGE of HEATERS, BOILERS, FURNACES

HISTORIC HOMES
HOUSE PARTS, DEFINITIONS

INSULATION IDENTIFICATION GUIDE

KIT HOMES, Aladdin, Sears, Wards, Others

LATH, METAL, PLASTER & STUCCO
LIGHTING, INTERIOR GUIDE

MOLD AGE - Old is the Mold?

PLASTER & BEAVERBOARD & DRYWALL
PLASTER BULGES & PILLOWS
PLASTER LATH, METAL
PLASTER, LOOSE FALL HAZARDS
PLASTER TYPE IDENTIFICATION

PLASTIC ROOFING TYPES

PLUMBING MATERIALS & FIXTURES, AGE of

RADIANT BARRIERS

ROLL ROOFING, ASPHALT

ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF ARCHITECTURAL STYLES - PHOTO GUIDE
ROOF CLEANING RECOMMENDATIONS
ROOF DORMER TYPES - PHOTO GUIDE
ROOF INSPECTION SAFETY & LIMITS

ROOF NOISE TRANSMISSION
ROOF REPLACEMENT SNAFUs
ROOF SLOPE DEFINITIONS
ROOF VENTILATION SPECIFICATIONS

ROOF NOISE TRANSMISSION

ROOFING FELT UNDERLAYMENT REQUIREMENTS
ROOFING MATERIALS, Age, Types
ROOFING TILE SHAPES & PROFILES
ROOFING UNDERLAYMENT BEST PRACTICES

ROT, FUNGUS, TERMITES
ROT, TIMBER FRAME

SADDLE CONSTRUCTION at CHIMNEYS

SEARS KIT HOUSES
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

SLATE ROOF INSPECTION & REPAIR
SNOW GUARDS on SLATE & METAL ROOFS
SOD ROOFING
SOUND CONTROL in buildings

STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAIRS, RAILINGS, LANDINGS, RAMPS
STUCCO WALL METHODS & INSTALLATION

STANDARDS for ROOFING
STONE CLEANING METHODS
STONE ROOFING
STRESS SKIN INSULATED PANELS

TEST LABS - ROOF SHINGLE
THATCH ROOFING
THERMAL EXPANSION of MATERIALS
THERMAL MASS in buildings

TILE ROOFING

TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

UNDERLAYMENT REQUIREMENTS on ROOFS

WALK-ON ROOF SURFACES

WALL SIDING TRIM & FINISHES
WALL FINISHES INTERIOR

WARRANTIES for ROOF SHINGLES

WATER ENTRY in buildings
WIND DAMAGE to ROOFS
WINTERIZE A BUILDING

WOOD SHAKE & SHINGLE ROOFING

WORKMANSHIP & ROOF DAMAGE

ZINC METAL ROOFING

More Information

Sketch of basic architectural house styles with common period dates

Guide to Roof Age, Style, & Choices of Roofing Materials - Determinng the Age of a Building
InspectAPedia®  -    

  • This building roof architectural style & materials photo guide and text help determine the age of a building roofing materials & styles
  • Building component age: construction materials, methods, including hardware, saw cuts, and other details can help determine when a building was constructed or when it was modified.
  • Questions & answers about how to estimate building age from its roofing architectural style and materials

Roof age & architectural style guide: Here we provide a photo guide and a series of detailed descriptive articles that offer guidance in determining the age of a building and its roof by examination of the choices of roofing materials as well as the building roof architectural style.

InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

Also see (page left links) article on specific types of roof covering such as ASPHALT ROOF SHINGLES where we include articles about how those materials wear, fail, or leak. The age of a building or its individual components can sometimes be determined quite accurately by documentation, but when documents are not readily available, visual clues such as those available during a professional home inspection can still determine when a house was built by examining its components, building materials, even nails, fasteners, and types of saw cuts on lumber.

Readers should also see Roofs & Architectural Styles - Photo Guide and Roof Dormer Types - Photo Guide

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Roofing Materials as Indicators of Building Age

PHOTO of wood shingle roof, Key West Florida, adjacent to Hemingway's house Wood shingle roofing has been in use for hundreds of years in the U.S. and Europe.

But an inspection of interior and exterior roofing details can indicate the probable age of a wood roof (which can last up to 40 years) as well as the roofing history of the building, the number and types of roofing layers, and related house-age-determination details.

The wood shingle roof shown in the photo below is on a building in Key West, Florida, adjacent to the Hemingway house, viewed from the Key West tower. Notice the absence of lichens on the wood shingles in the roof area below the metal-flashed rooftop tower?

We discuss here various roofing materials (Wood, slate, asphalt shingles (in several generations), clay tile, metal roofing (several styles and generations), and how they assist in finding The age of a building below.

History and Dates of Use of Various Roofing Materials

(in process)

This article explains the eras of use of different types of roofing materials as an aid to understanding the history and age of buildings. If you are trying to determine the age and condition of a particular roof covering, please see Roofing.

  • Asbestos fiber and asbestos cement roofing: see ASBESTOS CEMENT & FIBER CEMENT ROOFING and also see our quick review of Asbestos Cement Building Products given below.
  • Asphalt roofing shingles: see ASPHALT ROOF SHINGLES
  • Asphalt roll roofing:
  • Built-up roofing:
  • CLAY TILE ROOFING
      Clay Roofing Tile Types
      Clay Roof Tile Installation Specs
      Clay Roof Tile Connections
      CLAY TILE ROOF DAMAGE & WEAR
  • MASONITE WOODRUF FIBERBOARD ROOFING
  • Metal roofing and roof types:
  • Modified bitumen roofing:
  • Rubber and synthetic roof coverings:
  • Slate roofing materials: see SLATE ROOF INSPECTION & REPAIR
  • SOD ROOFING
  • STONE ROOFING
  • THATCH ROOFING
  • WOOD SHAKE & SHINGLE ROOFING
  • Wood Shingles

Cement Board & Fiber Cement Building Products

Asbestos-Cement Board & Fiberboard Products

Exterior Siding & Roofing Using Asbestos Cement included asbestos cement shingles, asbestos cement siding, corrugated asbestos-cement roofing.

See Asbestos Roofing Materials and ASBESTOS CEMENT & FIBER CEMENT SIDING

Other fiber cement materials used in construction included
TRANSITE PIPE AIR DUCTS
Transite Pipe Chimneys & Flues
Transite Pipe Water Supply Piping

Also see ASBESTOS IDENTIFICATION IN buildings and see SIDING MATERIALS, Age, Types

Modern Cement Board & Fiber Cement Products

Cement board is a non-structural building sheathing material which in its contemporary form is made from Portland cement covered with a reinforced fiberglass mesh fabric. Cement board is used as a tile backer or a backer board for stucco applications on buildings. Current producers include Custom Building Products (WonderBoard™) and US Gypsum (Durock™).

Panels made of a mixture of cement and wood fibers are produced for building siding by James Hardi (Hardi-panel and Cemplank™), and CertainTeed (Weatherboard™).

(History & dates in process, contributions invited - CONTACT us)

Visual clues pointed out by a home inspector or available to any careful building inspector can help indicate the age of a building.

Clues to building age include these examples which we expand and detail in text and articles below and listed at the left of this page.

Sketch of basic architectural house styles with common period dates
  • Architectural style, decorations, trim, building components - our introductory material is at ARCHITECTURE, STYLE, & Building Age. For detailed guides, see these articles:
    ARCHITECTURE & BUILDING COMPONENT ID
      Architectural Styles - Illustrated Guide
      Architecture Dictionary of buildings, Components
      Building Age & Architectural Style
      Chimney Architectural Styles - Photo Guide
      
      Mobile Homes, Modulars, Panelized, & Factory-Built
      Roofs & Architectural Styles - Photo Guide
      Roof Dormer Types - Photo Guide
         Window Types - Photo Guide
  • Building material types (shiplap siding, cement asbestos shingle siding, aluminum siding, vinyl siding, plywood vs. tongue and groove sheathing, even types of brick. See FLOORING MATERIALS, Age, Types, etc (listed below).
  • Chimneys & Fireplaces, Age, Type, chimney construction, type of mortar used, materials; also see Chimney Architectural Styles - Photo Guide
  • Electrical Components, Age, Types, electrical wiring, different wire types and generations of wire, fuses, circuit breakers, panels, etc.
  • FLOOR TILE HISTORY & INGREDIENTS - history of asphalt floor tile, vinyl-asbestos floor tile, dates, ingredients, manufacture
  • FLOORING MATERIALS, Age, Types wide board wood, strip flooring, pre-finished flooring, vinyl flooring, ceramic tile floors, vinyl-asbestos tile floors, "linoleum", carpeting, etc.
  • FOUNDATION MATERIALS, Age, Types, such as use of brick, stone, wood, concrete block, poured concrete
  • FRAMING MATERIALS, Age, Types, lumber width and edge finish of wood boards in various uses, interior trim, and
  • FRAMING METHODS, Age, Types, Construction and framing methods such as post and beam, presence or absence of a ridge board, balloon framing or platform framing
  • FRAMING SIZE & Spacing, Age, Types logs, hewn timbers, full-sized dimensional lumber, modern dimensional lumber, trusses, web trusses, panelized construction, etc.
  • Heating Equipment, Age, Types, such as mechanical systems and plumbing materials; presence of gas piping, style of fireplace
  • Insulation Materials, Age, Types, when did builders first no insulation, or use brick, corn cobs, newspaper, mineral wool, rock wool, vermiculite, fiberglass, chopped fiberglass, cellulose, foam board and spray foam insulating products?
  • Nails and Hardware, Age, Types Construction fasteners, nails, screws, the use of treenails or pegs in post and beam framing, and fasteners such as roofing nails and screws used, hardware: window and door hardware, hinges, doorknobs, door pulls, latches
  • Plaster & Beaverboard & Drywall what did we use on building walls before drywall and paneling? Ages and eras of plaster, plasterboard, wood lath, metal lath, etc.
  • Plumbing Materials & Fixtures, Age, Types such as lead and clay pipes, orangeburg pipe, cast iron, galvanized iron, PVC and ABS plastics
  • ROOFING MATERIALS, Age, Types, asphalt shingles, stone roofs, slate roofs, tile roofs, wood shingle and shake roofs, built up roofing ("tar and gravel roofs"), modified bitumen roofs, EPDM and other membrane roof coverings
  • Saw Cuts, Tool Marks, Age of, hand hewn adze marks or even the type of saw cut marks on framing lumber
  • Sears Kit Houses and also LOG HOME GUIDE for examples of pre-cut and kit homes.
  • SIDING MATERIALS, Age, Types
  • WINDOWS & DOORS, Age, Types
  • And many similar details are available to the careful eye.

Keep in mind that even when we can identify specific types of building materials and building methods, precise dating of the time of construction of a building remains difficult: old building materials were often re-used, so beams, siding, and other components may appear in a building built later than when the materials were first made.

Also, in the U.S. various states had machines for making cut nails, screws, and sawmills at different times. For example, New York State was industrialized earlier than some western or southern states, so machine-made nails appear earlier in New York than elsewhere.

Questions & Answers regarding this article

Questions & answers about how to estimate building age from its roofing architectural style and materials.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

  Roofs & Architectural Styles - Photo Guide
  Roof Dormer Types - Photo Guide

  • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. Thanks to Alan Carson and Bob Dunlop, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education including the ASHI-adopted Home Inspection Training Program (home study course), publications such as the Home Reference Book, report writing materials including the Horizon report writer, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
  • Thanks to reader Kathy Bohon for suggesting using various sources of public records to determine the age of a home, 7/30/2009.
  • Carson Dunlop, Associates, Toronto, have provided us with (and we recommend) Carson Dunlop Weldon & Associates' Technical Reference Guide to manufacturer's model and serial number information for heating and cooling equipment ($69.00 U.S.). Technical Reference Guide, Carson Dunlop Weldon & Associates, Ltd., 120 Carlton St. Suite 407, Toronto, Ontario, M5A 4K2 Canada, ISBN 1-895585-90-2 165pp.
  • America's Favorite Homes, mail-order catalogues as a guide to popular early 20th-century houses, Robert Schweitzer, Michael W.R. Davis, 1990, Wayne State University Press ISBN 0814320066 (may be available from Wayne State University Press)
  • American Plywood Association, APA, "Portland Manufacturing Company, No. 1, a series of monographs on the history of plywood manufacturing",Plywood Pioneers Association, 31 March, 1967, www.apawood.org
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print).
  • Building Research Council, BRC, nee Small Homes Council, SHC, School of Architecture, University of Illinois at Urbana-Champaign, brc.arch.uiuc.edu. "The Small Homes Council (our original name) was organized in 1944 during the war at the request of the President of the University of Illinois to consider the role of the university in meeting the demand for housing in the United States. Soldiers would be coming home after the war and would be needing good low-cost housing. ...  In 1993, the Council became part of the School of Architecture, and since then has been known as the School of Architecture-Building Research Council. ... The Council's researchers answered many critical questions that would affect the quality of the nation's housing stock.
    • How could homes be designed and built more efficiently?
    • What kinds of construction and production techniques worked well and which did not?
    • How did people use different kinds of spaces in their homes?
    • What roles did community planning, zoning, and interior design play in how neighborhoods worked?
    "
  • "An Example of Colonial Paneling", Norman Morrison Isham, The Metropolitan Museum of Art Bulletin, Vol. 6, No. 5 (May, 1911), pp. 112-116, available by JSTOR.
  • Manufactured & Modular Homes: Modular Building Systems Association, MBSA, modularhousing.com, is a trade association promoting and providing links to contact modular builders in North America. Also see the Manufactured Home Owners Association, MHOAA, at www.mhoaa.us. The Manufactured Home Owners Association of America is a National Organization dedicated to the protection of the rights of all people living in Manufactured Housing in the United States.
  • Re-Bath, tub lining products is a bath tub relining manufacturer and distributor located in Tempe, Arizona - see rebath.com
  • Pergo AB, division of Perstorp AB, is a Swedish manufacturer or modern laminate flooring products. Information about the U.S. company can be found at http://www.pergo.com where we obtained historical data used in our discussion of the age of flooring materials in buildings.
  • Plank House Construction: webslog from plankhouse.wordpress.com/2009/01/25/plank-house-construction/ and where plank houses were built by native Americans, see
    Large 1:6 Scale Plank House Construction / P8094228, Photographer: Mike Meuser
    06/12/2007 documented at yurokplankhouse.com where scale model Museum quality Yurok Plank Houses are being sold to raise money for the Blue Creek - Ah Pah Traditional Yurok Village project.
  • Scott C. LeMarr has provided his file of keys to decode Furnace and Water Heater Age from the data provided on the manufacturer's equipment labels. Mr. LeMarr is a professional home inspector, Certified Professional Inspector/President, MASTER Indoor Environmental Specialist (MIES). Vice President of Wisconsin NACHI. He and his company, Honest Home Inspections, LLC. can be reached at 262-424-5587 or by email to scott@honesthomeinspections.com
  • Weaver: Beaver Board and Upson Board: Beaver Board and Upson Board: History and Conservation of Early Wallboard, Shelby Weaver, APT Bulletin, Vol. 28, No. 2/3 (1997), pp. 71-78, Association for Preservation Technology International (APT), available online at JSTOR.
  • What Style Is It?: A Guide to American Architecture, Rev., John C. Poppeliers, S. Allen Chambers, Wiley; Rev Sub edition (October 6, 2003), ISBN-10: 0471250368, ISBN-13: 978-0471250364

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson Dunlop The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop. The Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
  • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
  • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
  • The Journal of Light Construction has generously given reprint permission to InspectAPedia.com for this article. All rights and contents are ©Journal of Light Construction and may not be reproduced in any form.
  • Asphalt Roofing Residential Manual,
  • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
  • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
  • Concrete Folded Plate Roofs, C. Wilby PhD BSc CEng FICE FIStructE (Author), Butterworth-Heinemann, 1998, ISBN-10: 0340662662, ISBN-13: 978-0340662663
  • Concrete Shell Roofs, C. Wilby PhD BSc CEng FICE FIStructE (Author),
  • Concrete Dome Roofs (Longman Concrete Design and Construction Series),
  • Green Roof Plants: A Resource and Planting Guide, Edmund C. Snodgrass, Lucie L. Snodgrass, Timber Press, Incorporated, 2006, ISBN-10: 0881927872, ISBN-13: 978-0881927870. The text covers moisture needs, heat tolerance, hardiness, bloom color, foliage characteristics, and height of 350 species and cultivars.
  • Green Roof Construction and Maintenance, Kelley Luckett, McGraw-Hill Professional, 2009, ISBN-10: 007160880X, ISBN-13: 978-0071608800, quoting: Key questions to ask at each stage of the green building process Tested tips and techniques for successful structural design Construction methods for new and existing buildings Information on insulation, drainage, detailing, irrigation, and plant selection Details on optimal soil formulation Illustrations featuring various stages of construction Best practices for green roof maintenance A survey of environmental benefits, including evapo-transpiration, storm-water management, habitat restoration, and improvement of air quality Tips on the LEED design and certification process Considerations for assessing return on investment Color photographs of successfully installed green roofs Useful checklists, tables, and charts
  • Handbook of Building Crafts in Conservation, Jack Bower, Ed., Van Nostrand Reinhold Company, NY 1981 ISBN 0-442-2135-3 Library of Congress Catalog Card Nr. 81-50643.
  • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
  • Historic Slate Roofs : With How-to Info and Specifications, Tina Skinner (Ed), Schiffer Publishing, 2008, ISBN-10: 0764330012 , ISBN-13: 978-0764330018
  • Low Slope Roofing, Manual of, 4th Ed., C.W. Griffin, Richard Fricklas, McGraw-Hill Professional; 4 edition, 2006, ISBN-10: 007145828X, ISBN-13: 978-0071458283
    • Roof failure causes in depth (and specific methods for avoiding them)
    • Roof design fundamentals and flourishes, based on voluminous industry research and experience
    • New technologies and materials -- using them safely and correctly
    • Comprehensive coverage of all major roofing systems pecifications, inspection, and maintenance tools for roofing work
  • Metal Roofing, an Illustrated Guide, R.A. Knowlton , [metal shingle roofs],
  • Problems in Roofing Design, B. Harrison McCampbell, Butterworth Heineman, 1991 ISBN 0-7506-9162-X (available used)
  • Roofing The Right Way, Steven Bolt, McGraw-Hill Professional; 3rd Ed (1996), ISBN-10: 0070066507, ISBN-13: 978-0070066502
  • Slate Roofs, National Slate Association, 1926, reprinted 1977 by Vermont Structural Slate Co., Inc., Fair Haven, VT 05743, 802-265-4933/34. (We recommend this book if you can find it. It has gone in and out of print on occasion.)
  • The Slate Roof Bible, Joseph Jenkins, www.jenkinsslate.com, 143 Forest Lane, PO Box 607, Grove City, PA 16127 - 866-641-7141 (We recommend this book).
  • Slate Roofing in Canada (Studi4es in archaeology, architecture, and history),
  • Smart Guide: Roofing: Step-by-Step Projects, Creative Homeowner (Ed), 2004, ISBN-10: 1580111491, ISBN-13: 978-1580111492
  • Tile Roofs of Alfred: A Clay Tradition in Alfred NY
  • "Weather-Resistive Barriers [copy on file as /interiors/Weather_Resistant_Barriers_DOE.pdf ] - ", how to select and install housewrap and other types of weather resistive barriers, U.S. DOE
  • Wood Shingle Roofs, Care and Maintenance of wood shingle and shake roofs (EC), Stanley S. Niemiec (out of print)
  • ...