CERTIFICATIONS for ROOFING CONTRACTORS CHOOSING A ROOFING CONTRACTOR ASBESTOS CEMENT & FIBER CEMENT ROOFING ASPHALT ROOF SHINGLES BUILT UP ROOFS CERTIFICATIONS for ROOFING CONTRACTORS CHIMNEY INSPECTION & REPAIRS CHOOSING A ROOFING CONTRACTOR CLAY TILE ROOFING CONCRETE ROOFING CORRUGATED ROOFING ENERGY SAVINGS in BUILDINGS FIRE RETARDANT PLYWOOD FLAT ROOF MOISTURE & CONDENSATION HEAT TAPES & CABLES on Roofs for Ice Dams INSULATION & VENTILATION INSPECTION & IMPROVEMENT LOW SLOPE ROOFING MATERIALS MASONITE WOODRUF FIBERBOARD ROOFING MEMBRANE & SINGLE PLY ROOFS METAL ROOFING TYPES MODIFIED BITUMEN ROOFING ROOF INSPECTION SAFETY & LIMITS ROOF VENTILATION SPECIFICATIONS ROOF VENTING ENERGY SAVING DETAILS SLATE ROOF INSPECTION & REPAIR How to Inspect & Repair Types of Roofing Slate Slate Colors, Chemistry Slate Roof Aging and Durability Ribbon Slates Slate Roof Installation Quality Other factors in Condition Slate Roof Repair history Slate Roof Leaks Slate Holding actions How to Repair Slate Roofs Copper Tab Method Slate Hook Method SLATE ROOF PHOTO LIBRARY Slate References Slate Sources, Repairs SLATE ROOF INSPECTION CLASS SOD ROOFING SIDING WOOD STAIN DIAGNOSIS on Building Exteriors STAIN DIAGNOSIS on Roofs STANDARDS for ROOFING STONE ROOFING THATCH ROOFING THERMAL EXPANSION of MATERIALS THERMAL MASS in BUILDINGS THERMAL MASS in UPSTAIRS TILE ROOFING WARRANTIES for ROOF SHINGLES WOOD SHAKE & SHINGLE ROOFING WORKMANSHIP & WIND DAMAGE More Information InspectAPedia Blog - News Updates Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Privacy Policies Contact Us |
We also provide slate sources and where to buy slate roofing materials and slate roofing tools and products. This is a detailed article describing procedures for evaluating the condition of slate roofing. How to inspect, identify defects, and estimate remaining life of slate roofs are addressed. The article also references slate repair procedures, repair slate sources, and slate quarries. © Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use the links at page left to navigate this document or to go to Other Website Topics. Green links at left show where you are in our document & website. Slate Roof Replacement & Repair Sources
Slate "look alike" products are also available using cementious materials. If the building owner cannot afford to repair a slate roof where most slates are intact, holding action slate roof repairs should be followed, such as simply sliding metal flashing up under broken or missing slates on the roof. We purchased this slate removing tool (also useful for removing other types of roof shingles where careful work is needed) at Davies Hardware, on Main Street in Poughkeepsie, NY.
In addition to these slate sources there are several slate look-alike substitutes. While the application techniques, flashing and nailing concerns are similar, the wear characteristics of these materials may be quite different and were not evaluated for this paper. This paper is not an endorsement, nor a critique of any of these materials.
Slate Roofing References
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. SLATE ROOF INSPECTION & REPAIR About The AuthorsAlan Carson and Dan Friedman are ASHI Members, home inspectors, educators and writers in Toronto and Poughkeepsie respectively. Information in this article is taken from the references shown below, from inspection experience, from opinions shared at ASHI and other education seminars, from the authors' personal, limited experience repairing and rebuilding of slate roofs, and from very helpful Bill Markcrow and Doug Sheldon at Vermont Structural Slate Co. We also paraphrased from a presentation to NY Metro ASHI Members by Mr. Steven Trapasso in October, 1990. Mr. Trapasso has 40 years experience in working with slate, and has a clear love affair with the material, particularly when it comes from Vermont. | ||||||
|
ROOFING INSPECTION & REPAIR More Information InspectAPedia Blog - News Updates Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Roofing Plumbing Water Septic Structure Accuracy & Privacy Policies Contact Us |