InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
Home | Air
Conditioning
| Electrical
-
Energy Saving
| Environment
Indoor
| Exteriors | Heating | Home
Inspection
| Insulate
-
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Solar
Energy
| Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


SEPTIC SYSTEMS HOME
HOW TO FIND A SEPTIC TANK
SEPTIC SEARCH SAFETY
WHO KNOWS SEPTIC LOCATION?
FIND MAIN WASTE LINE EXIT
DISTANCE TO TANK
POSSIBLE SEPTIC TANK LOCATIONS
  VISUAL CLUES LOCATE TANK
  WHERE TO LOOK
  SEPTIC TANK DEPTH
SEPTIC TANK LOCATING EQUIPMENT
SEPTIC TANK COVERS
DOCUMENT TANK LOCATION

Septic Systems Bookstore
SEPTIC VIDEOS

More Information

InspectAPedia® Home & Site Map
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



LARGER IMAGE: having a general idea of what septic components are helps you find where they may be locatedA Guide to Possible Septic Tank Locations
InspectAPedia®  -    

  • A Guide to Possible Septic Tank Locations helps us determine how to find the septic tank and drainfield
  • Where to look for the septic tanks, septic tank covers, or septic tank cleanout lids
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

Septic tank location guide: this document provides procedures for finding a septic tank by considering what locations are possible. This article tells us how to locate a septic tank when it's placement is not already known or when the location of the septic tank is not visually obvious. Videos showing how to find the septic system, septic tank, & septic drainfield are at SEPTIC VIDEOS. Also see Drainfield Location - how to find the leach fields.

Citation of this article by reference to this website and brief quotation for the sole purpose of review are permitted. Use of this information at other websites, in books or pamphlets for sale is reserved to the author. Reviewers and content suggestions are welcome and are credited at "References." This document is a chapter of Inspecting, Testing, & Maintaining Residential Septic Systems an online book on septic systems.

© Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

How to Find the Septic Tank by Looking Outside the Building

The photo at page top shows a terrible way to find the septic tank - by driving over it and getting stuck. A survey of a building site for locations that could reasonably be expected to house a septic tank or drainfield is a useful step in understanding where septic components could be buried.

POSSIBLE TANK LOCATIONS - Site Conditions Determine Possible Septic Tank Locations

If you have no idea what a septic system is, see the "More Reading" articles below. If you have a general picture of what the typical septic system components are, how big they are, and how they are connected together, you can have a reasonable idea about where these items might even fit at a property.

LARGER IMAGE: melted snow may mark septic tank location In this example, my client is pointing to an area of obvious fill across the yard in front of his new home. Everywhere else was thick with trees and also was swampy. The septic system tank and fields were almost certainly going to be in this (improperly prepared) mounded area. Look in the distant photo at the original grade and you'll see that the contractor put the mound in a natural swale which turned out to be a natural creek - the system lacked sufficient fill soil - effluent moved from the leach field to the stream the contractor had buried, and simply appeared at the end of the mound. But that's another story.

Look around the building site with these septic tank location tips in mind:

  • The septic tank is probably on the property - though in unusual cases such as the subdivision of a family property it might be on the neighbor's land.
  • Septic tanks need space to be buried-in, normally eight feet or more of soil, though special "low boy" tanks can be placed in as little as four feet of soil and advanced wastewater treatment systems can be above ground entirely. (You won't have trouble seeing advanced aboveground systems.
  • Often septic tanks are located close to buildings (perhaps 10 feet away) in areas where there appears to be space for the tank and adequate soil depth, but at a problem site such as a house built on a rock cliff or on a steep slope, the tank may have been located at some distance. Look for other property areas which are not thickly populated with mature trees. (It would be foolish to plant trees over the septic components but people may do so. But at a fairly modern site, the excavator digging to place the septic tank won't have jammed her backhoe among huge old close-together trees.
  • Look for the septic tank (and drain fields) downhill from the building: unless a pumping system is installed (you should find switches, alarms, wires), the septic system is working by gravity. The tank will not normally be far uphill from the building.
  • Look for the septic tank uphill from the building: if a pumping system is installed the tank may be anywhere, but still we needed space and soil depth to locate it. If there is an obviously "constructed" area of earth fill (a mound system) serving as a probable leach field, the tank may be at the near (to building) end of that mound.

More Reading:
Drawing Library © drawings of septic system components, fields, layouts. These are educational, not engineering drawings and are © protected. Sample engineering drawings and plans wanted for the website.
Safety: Septic System, Septic Tank, & Cesspool Safety Warnings for Septic Inspectors, Septic Pumpers, and Homeowners
What is a Septic System An Engineer's View, & Septic System FAQ's

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

HOW TO FIND A SEPTIC TANK
SEPTIC SEARCH SAFETY
WHO KNOWS SEPTIC LOCATION?
FIND MAIN WASTE LINE EXIT
DISTANCE TO TANK
POSSIBLE SEPTIC TANK LOCATIONS
  VISUAL CLUES LOCATE TANK
  WHERE TO LOOK
  SEPTIC TANK DEPTH
SEPTIC TANK LOCATING EQUIPMENT
SEPTIC TANK COVERS
DOCUMENT TANK LOCATION

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building design, inspection, and repair, and about indoor environment testing, diagnosis, and cleanup are at the InspectAPedia Bookstore.
  • ...
SEPTIC SYSTEMS HOME
HOW TO FIND A SEPTIC TANK
SEPTIC SEARCH SAFETY
WHO KNOWS SEPTIC LOCATION?
FIND MAIN WASTE LINE EXIT
DISTANCE TO TANK
POSSIBLE SEPTIC TANK LOCATIONS
  VISUAL CLUES LOCATE TANK
  WHERE TO LOOK
  SEPTIC TANK DEPTH
SEPTIC TANK LOCATING EQUIPMENT
SEPTIC TANK COVERS
DOCUMENT TANK LOCATION

SEPTIC INFO ARTICLES
HOME BUYERS GUIDE to SEPTIC SYSTEMS
SEPTIC PUMPING REPAIR
SEPTIC TREATMENTS
SEPTIC CONSULTANTS
SEPTIC AUTHORITIES
SEPTIC SYSTEM BOOKS REFS CODES
SEPTIC SYSTEM DESIGN MANUAL - Online
SEPTIC SYSTEM DESIGN BASICS
SEPTIC SYSTEM DESIGN ALTERNATIVES

Septic Systems Bookstore
SEPTIC SYSTEMS ONLINE BOOK
SEPTIC VIDEOS
List Your Service/Product

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Roofing
Plumbing Water Septic
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

04/12/2008 - 05/20/2006 - InspectAPedia.com/septic/SepticTankFind3.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark