SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

SEPTIC CARE INSTRUCTIONS
SEPTIC CONSULTANTS
SEPTIC D-BOX INSPECTION
SEPTIC DRAINFIELD FAILURE DIAGNOSIS
SEPTIC DRAWINGS
SEPTIC DYE TEST PROCEDURE
SEPTIC FAILURE SIGNS
SEPTIC INSPECTION & TEST GUIDE
SEPTIC LIFE EXPECTANCY
SEPTIC ODORS
SEPTIC PUMPS
SEPTIC SUPPLIES & PARTS
SEPTIC SYSTEM DESIGN ALTERNATIVES
SEPTIC SYSTEM DESIGN BASICS
SEPTIC SYSTEMS, HOME BUYERS GUIDE to
SEPTIC SYSTEM SAFETY WARNINGS
SEPTIC TANKS
SEPTIC TREATMENTS & CHEMICALS
SEWAGE & SEPTIC CONTAMINANTS
SEWAGE BACKUP, WHAT TO DO
SEWAGE BACKUP TEST & CLEANUP
SEWAGE BACKUP PREVENTION
SEWAGE CONTAMINATION in buildings
SEWAGE CONTAMINANTS in FRUIT / VEGETABLES
SEWAGE EJECTOR / GRINDER PUMPS
SEWAGE LEVELS in SEPTIC TANKS
SEWAGE NITROGEN CONTAMINANTS
SEWAGE PATHOGENS in SEPTIC SLUDGE
SEWAGE PUMPS
SEWER BACKUP PREVENTION
SEWER GAS ODORS
SEWER LINE REPLACEMENT
SINKHOLES, WARNING SIGNS
SMELL PATCH TEST to Track Down Odors
SOAKAWAY BED FAILURE DIAGNOSIS
SULPHUR & SEWER GAS SMELL SOURCES
SUMP PUMPS

TOILETS, INSPECT, INSTALL, REPAIR
TOILET ALTERNATIVES
TOILETS, DON'T FLUSH LIST
TRAPS on PLUMBING FIXTURES
TREATMENTS & CHEMICALS, SEPTIC

VIDEO GUIDES: Septic Videos

WASHING MACHINES & SEPTIC SYSTEMS
WATER SOFTENERS & CONDITIONERS
WATER SUPPLY & DRAIN PIPING
WASTEWATER TREATMENT BASICS
WATER, WELLS, WATER TANKS: TESTING GUIDE
WINTERIZE A BUILDING

More Information

Photograph of a septic cleaning contractor opening a septic tank for inspection and pumping.Online Class: Inspecting Septic Systems, Testing Methods & Procedures
     

  • Classroom presentation on how to inspect, diagnose, and test septic systems, septic tanks, septic piping, and septic drainfields.
    • What is a Septic System - What is Onsite Wastewater Disposal? How do septic systems work?
    • Types, Causes, and Failure Criteria for Septic Systems: Defining "Failed" Onsite Wastewater Treatment or Disposal
    • Septic maintenance requirements; septic inspection safety procedures
    • Locate the septic tank, d-box, drainfields; inspection points
    • How to Inspect & Evaluate the Condition of Septic Systems - sequence of steps
    • Septic Inspector Qualifications/Licensing; Levels of septic inspection
  • SEPTIC SYSTEM INSPECTION LEVELS - separate article
    • LEVEL-0 SEPTIC INSPECTIONS or LEVEL-1 SEPTIC INSPECTIONS
    • LEVEL-2 SEPTIC INSPECTIONS or LEVEL-3 SEPTIC INSPECTIONS
  • Questions & Answers about how to inspect or test septic systems, septic inspection procedures, septic failure criteria, and septic inspection results reporting.
  • References

Click to Show or Hide Related Topics

  • SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR - home
  • BOD WASTEWATER TEST
  • CHLORINE IN SEPTIC WASTEWATER
  • CHLORAMINE / CHLORINE Tests
  • CLEARANCE DISTANCES, SEPTIC SYSTEM
  • CLOGGED DRAIN DIAGNOSIS
  • EFFLUENT RETENTION TIME
  • FLOODED SEPTIC SYSTEMS, REPAIR
  • GUIDE TO SEPTIC SYSTEMS
  • HOW SEPTIC SYSTEMS WORK
  • HOME BUYERS GUIDE to SEPTIC SYSTEMS
  • HOME SELLERS GUIDE
  • ODORS, SEPTIC or SEWER
  • PLANTS & TREES OVER SEPTIC SYSTEMS
  • SEPTIC & CESSPOOL SAFETY
  • SEPTIC BIOMATS
  • SEPTIC CLEARANCE DISTANCES
  • SEPTIC COMPONENT LOCATIONS
  • SEPTIC LOADING & DYE TEST PROCEDURE - home
  • SEPTIC PUMPS
  • SEPTIC SYSTEMS, PLANTS OVER
  • SEPTIC SYSTEM INSPECTION & TEST GUIDE - home
    • ABANDONED or NEW SEPTIC SYSTEM TESTS
    • DISPOSAL vs TREATMENT
    • SEPTIC FAILURE CAUSES / SIGNS
    • SEPTIC FAILURE CRITERIA
    • SEPTIC FAILURE LAWSUIT
    • SEPTIC FAILURE WET SPOTS
    • SEPTIC D-BOX INSPECTION
  • SEPTIC DRAINFIELD INSPECTION & TEST - home
    • SEPTIC DRAINFIELD LOCATION
    • SEPTIC DRAINFIELD FAILURE CAUSES
    • SEPTIC DRAINFIELD FAILURE DIAGNOSIS
    • SEPTIC DRAINFIELD LIFE
  • SEPTIC SYSTEM INSPECTION CLASS
    • SEPTIC INSPECTION LEVELS
    • SEPTIC SYSTEM INSPECTION WORK SHEETS
  • SEPTIC SYSTEM ODORS
  • SEPTIC SYSTEM PUMPS
  • SEPTIC SYSTEM SAFETY WARNINGS
  • SEPTIC TANK INSPECTION PROCEDURE - home
    • SEPTIC TANK GRASS or SNOWMELT
    • SEPTIC TANK LOCATION
  • SEPTIC TANK PUMPING PROCEDURE - home
  • SEWAGE EJECTOR / GRINDER PUMPS
  • SEWAGE LEVELS in SEPTIC TANKS
  • SOIL CONDITIONS
InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

How to conduct septic inspections & report septic system conditions: this septic system inspection and testing classroom presentation explains how septic systems are inspected & tested, from the basics of what a septic system is, what the components of a septic system are, how each component is found and inspected, and what constitutes a septic system failure at each component or step. We give detailed procedures for visual inspection of septic systems, septic system testing including loading and dye tests and other procedures, invasive inspection methods, septic tank pumping, D-box examination, field inspection, septic capacity evaluation, & reporting the condition of septic systems, drywells, cesspools, leachfields, galleys and other onsite waste disposal systems and equipment. Future trends in on site waste / wastewater disposal & legislation pertaining to septic systems and groundwater contamination are also discussed.

Green links show where you are. © Copyright 2013 InspectAPedia.com, All Rights Reserved. Author Daniel Friedman.

 Septic Inspection Procedure - Online Course

Sketch of a conventional septic system showing tank and drainfieldsIf you already know the basics about septic systems, tanks, drainfields, and septic inspection procedures in general, then you can skip immediately our list of individual, detailed septic inspection procedures found at SEPTIC SYSTEM INSPECTION & TEST GUIDE.

Home buyers who want less technical advice should see the Home Buyer's Guide to Septic Systems. Also see The Septic Systems Home Page.

The text of this septic inspection class and guide follows the indexed contents listing immediately below.

Septic system inspection class with text and illustrations for the inspection, testing, and diagnosis of septic systems (onsite wastewater disposal systems) provided by Daniel Friedman at Inspection Training Associates Inspection Expo '98, Riviera Hotel, Las Vegas NV October 1-4, 1998 [updated and expanded through05/17/2012] The author is a Massachusetts Licensed Title 5 Septic Inspector, and a licensed home inspector New York State License # 16000005303 (inception to 2008). Other credentials are at our bio and our contact information available online.

  • What is a Septic System - What is Onsite Wastewater Disposal?
    • Explaining septic systems to clients
    • What are the Functions of a Septic System:
    • What are the Components of a Typical Septic System (Onsite Waste Disposal System)
    • Special Types of Septic Systems and Alternative Septic Designs
  • Septic Failure Causes for Septic Systems: Defining "Failed" Onsite Wastewater Treatment or Disposal
    • Septic Failure Criteria
    • Cesspool failures (MA) Massachusetts
    • Soil Absorption System Failures (leach fields, drain fields, seepage pits)
  • Maintenance Needs of Septic Systems
    • Septic Tank pumping frequency depends on these variables:
  • Septic System Inspection Safety & Health Concerns:
  • How to Inspect & Evaluate the Condition of Septic Systems - On Site Waste Disposal
    • Collect Historical Information about the Onsite Waste Disposal System
    • Visual Site Inspection of the Septic System:
    • Locate the Septic System
    • Inspecting Outside Waste Piping
    • Performing Septic Loading & Dye Tests
    • Pumping Septic Tanks for Further Investigation of System Condition
    • Excavating & Inspecting Septic Distribution Boxes
    • Inspecting the Soil Absorption System of an Onsite Wastewater Disposal System
  • Recent & Future Trends in Onsite Waste Disposal Systems
    • Concern for Water Quality is increasing
    • Effluent Disposal vs. Treatment
    • Legislation & Mandated Upgrades
    • Alternative and Advanced Onsite Waste Water Treatment & Disposal Systems are Available
    • Global Warming & Septic Systems
  • Septic system inspector licensing or qualifications
  • Septic system inspection levels: level 0, level 1, level 2 defined
  • Sample Septic Inspection Worksheets & Test Reports

What is a Septic System - What is Onsite Wastewater Disposal?

A "septic system," also referred to as a private, on-site waste disposal system, receives waste water and solids from a building's plumbing facilities (bathrooms, kitchens, shower, laundry), treats, and then disposes of the effluent from this waste, by permitting it to absorb into soils at the property.

As we elaborate at WHAT IS A SEPTIC SYSTEM?, a septic system at a typical home consists of a septic tank or "holding Tank" where natural bacterial action decomposes human waste products into environmentally acceptable components - the major end-components being water, mixed with some other components that are not readily consumed by the bacterial action, gases, and undigested solids.

The end products, except the undigested solids, are then discharged to the on-site environment. In a conventional septic tank, sewage waste treatment is just partial, up to about 45% of what is needed. The remaining treatment of wastewater as well as the actual disposal of liquid waste (clarified effluent) is in the soils of the drainfield.

Wastewater or septic effluent treatment is accomplished by bacterial (and other microorganism) action in the "septic" or "treatment" tank and it is mostly accomplished by bacteria in the soil around and below the effluent absorption system, or "drain field." This bacterial action is needed to reduce the level of pathogens in the effluent discharges from the waste system into the soil. In addition to reducing the level of pathogens and the reduction of organic waste to a combination of new cell masses, CO2, and water, wastewater treatment removes organic matter, nitrites and nitrates, and phosphorous. In an absorption field the soil performs an additional role of filtering the septic effluent.

Having a property served by a private or onsite septic system means that wastewater, that is blackwater from toilets and graywater from sinks, showers, washers, etc., is disposed-of on the property rather than being piped to a municipal sewage treatment plant. Actually this is speaking carelessly. More precisely, solid waste is retained in a holding (septic) tank from which it is periodically removed for disposal at an approved dumping facility. Clarified effluent is discharged from the tank (onsite wastewater) and is allowed to seep into the soil on the property through a drainfield or other system.

Explaining septic systems to a home owner or home buyer

"Yuck! You mean sewage stays in my yard?" I don't want that stuff on my property!

Yep. But not to worry, properly installed and maintained, the system can be sanitary and unobtrusive. It's true however that some maintenance is needed, particularly periodically pumping the tank. We'll talk about that in a minute. First let's look at a very basic understanding of what's installed and how it works.

The principal components of a private on-site waste disposal system usually include the following:

  • Wastewater Piping connecting the building to the treatment tank conducts wastewater from toilets, sinks, tubs, showers, out to a septic tank. Wastewater from toilets is called "black water" and wastewater from sinks is called "graywater"
  • A septic tank or sewage treatment tank which retains solid waste, letting liquid waste flow to an onsite disposal system. Be sure to see SEPTIC TANK PUMPING SCHEDULE since pumping the septic tank regularly is the single most useful thing you can do to extend the life of a septic system.
  • Effluent piping connecting and conducting clarified effluent from the treatment tank to a distribution box
  • A distribution box connecting the effluent line from the tank to the absorption system or "drain field" - SEPTIC D-BOX INSPECTION
  • An absorption system which permits effluent to drain to soils below and some of it to evaporate to air above. There are many ways to get rid of septic effluent, described at SEPTIC SYSTEM DESIGN BASICS and at SEPTIC SYSTEM DESIGN ALTERNATIVES, or see the list and definitions given at Master List of Septic System Types
  • A bio-mat or bio-mass of pathogen-digesting bacteria which forms in soil below the absorption system. The bio-mat is what makes the wastewater sufficiently sanitary to discharge into the ground.

Many variations on this general scheme are used, depending on local climate, soil conditions, available space, economy, and available materials. Special equipment and systems may be designed for problem or difficult sites such as rocky or wet ground, permafrost, or wet tropical marshlands.

Below is a simple sketch of a septic tank showing how solid waste is retained inside the tank while liquid effluent flows to the drainfield. (Click images to see an enlarged version).

Septic tank sketch

Key articles for people unfamiliar with septic systems: If you don't know if your building is connected to a public sewer or a private septic system, see SEPTIC or SEWER CONNECTION?.

Readers should also See Septic Guide for Home Buyers or Owners and Septic Maintenance Repair.

Other helpful but still basic articles for owners of a property with a septic system include:

  • Septic Tank Pumping Guide: When, Why, How to pump the septic tank
  • Table of Required Septic & Well Clearances: Distances Between Septic System & Wells, Streams, Trees, etc.
  • Ten Steps to Keeping a Septic System Working, suggestions from the U.S. EPA, edits and additions by DJF
  • What is a Septic System An Engineer's View & Septic System FAQ's

What are the Functions of a Septic System:

In a typical modern system, waste from house plumbing, (kitchen sink, bathroom sink, shower, toilet, laundry) flows through house waste pipes into a two-part system: a septic tank, whose job is to retain all solid waste, and a soil absorption system whose job is to permit clarified effluent (liquid from the tank) to seep into the soil. In the absorption system bacteria which occur naturally in the soil digest septic bacteria and other pathogens so that the liquid is eventually sanitary and doesn't contaminate the private wells, ponds, or streams. There is some bacterial action in the tank but most of it, and all of the important action occurs in the soil absorption system.

What are the Components of a Typical Septic System (Onsite Waste Disposal System)

What is the Septic Tank and What's its Function?

The septic tank in a modern system is a water tight container, usually concrete, sometimes fiberglass. Older steel tanks were used in many areas but might be considered a problem because of both small size and because eventually they rust out and fail. The tank is normally "full" of liquid and waste all the time. Since the tank is normally water tight, if we run 100 gallons of water in the house, 100 gallons of water enters the tank and pushes 100 gallons of effluent out of the tank into the soil absorption system.

The job of the septic tank is to keep solid waste from flowing out into the absorption system where it would clog the soil absorption system. Floating debris such as grease collects in the scum layer. Heavier solid waste eventually settles to the bottom of the tank.

Some wastewater treatment occurs in the tank, up to perhaps 40% of the total treatment needed before wastewater is discharged to the environment. Treatment in the septic tank includes mostly anaerobic bacterial action and conversion of organic nitrogen to ammonia.

Anaerobic treatment in a conventional septic tank is slow and incomplete. You can see that the "tees" or baffles to permit only liquid effluent to flow out of the tank to the absorption field. Alternative septic system designs, and there are quite a few, include aerobic septic systems which, by adding oxygen and air to the septic tank, increase the level of treatment there. Septic tanks require periodic cleaning to remove solids - more on that later at Pumping Septic Tanks.

Alternative septic system designs such as aerobic septic tanks use a pump to add air (oxygen) to the septic tank or other methods to increase the level of sewage treatment in the tank. But beware of just adding an air pump to a conventional septic tank not designed for that purpose: the continued agitation waste in such a tank can lead to rapid clogging failure of the drainfield. See Septic System Design for a wide variety of alternative septic system designs including aerobic and others.

More Reading about Septic System Basics and Septic Tanks

  • Buyer's Guide Home Buyer's Guide to Septic Systems Inspection & Testing - What to Do, Step by Step.
  • What is a Septic System An Engineer's View & Septic System FAQ's
  • Ten Steps to Keeping a Septic System Working, suggestions from the U.S. EPA, edits and additions by DJF
  • Retention Time in Septic Tanks Septic Tank Pumping Guide discusses retention time and "net free area" in a tank (allowing for sludge and scum layers)

Above you can see sketches of two commonly-used concrete septic tanks.

What is the Septic Leach Field. What are its Components and its Function?

Clarified effluent flows from the tank into a soil absorption system, (SAS), also commonly called a drainfield, leach field, leaching bed. The drainfield is typically made of perforated pipes buried in gravel-filled leaching trenches or in a leaching bed. There are other types of SAS as well, and in the case of alternative or slightly more sophisticated septic systems, perhaps a raised bed or sand bed system.

The job of the soil absorption system is to treat the effluent by removing contaminants. This happens as the effluent soaks into the soil where bacterial action and filtration take place to convert unsanitary liquid to a sanitary condition before it flows onward deeper into the soil or ultimately to other locations. A biological mat forms below the SAS and performs this treatment.

Here's a sketch of side and top views of a system. Notice the three "drop boxes" also called distribution boxes which are used to connect several perforated pipes together.

Here's an idea of how effluent flows into the soil from the soil absorption system:

The job of the distribution box, or drop-box, or "d-box" is to provide equal distribution to each absorption pipe or trench, or in some cases to allow you to adjust the flow of septic effluent unevenly among various leachfield lines if that's needed.

Notice that in proper operation the effluent is moving down, not up to the surface.

The Homeowner is Responsible for Septic System Maintenance & Repairs

Septic systems are costly to install and they are not entirely care free. In the septic tank, undigested solids (sludge) in the bottom of the septic tank should be pumped out every two to four years, depending on usage and tank size - exactly when to pump or clean out the septic is given at SEPTIC TANK PUMPING SCHEDULE. If the septic tank sludge is not removed periodically, it will eventually carry over into the leach field and cause the field to fail.

A well designed septic system can handle a reasonable amount of normal household chemicals such as drain cleaners, laundry detergent and bleach; excessive usage can be detrimental. You should avoid putting in chemicals that are toxic to the bacteria, such as paint thinner, solvents, insecticides, etc. See WHAT CAN GO INTO TOILETS & DRAINS? for details of what should not be flushed down toilets or other drains. And if a garbage disposal is used, more frequent tank pumping may be needed. (See GARBAGE DISPOSAL vs SEPTICS)

Depending on the size of the tank and your location, plan on a cost of about $200 each time the tank is pumped. When the tank is pumped, your service person should also check the tank baffles for possible damage; ask them to do this inspection before you contract with them. While the tank is open, the service technician can also run some water from a hose into the distribution box to get an indication that the leach field is also still functioning; ask if the company offers this service.

More Reading about Septic System Drainfields or Leach Fields

  • Absorption Field Design size and specifications for leach fields, absorption beds, gravelless systems, seepage pits
  • Absorption Fields Trench Length has an example of calculating leach line trench length.
  • Leach Field Size specifications for leach fields, absorption beds, gravelless systems, seepage pits
  • Percolation Tests septic soil tests, deep hole tests
  • Planting Over Septic Systems: trees, shrubs, groundcover over the septic system: what can you plant over or near septic system components without causing a problem?
  • Wastewater Treatment Basics describes the basic processes that occur in wastewater treatment processes

Special Types of Septic Systems and Alternative Septic Designs

Older properties used systems such as cesspools, or tanks connected to DRYWELL DESIGN & USES or seepage pits which worked but often have more limited capacity and/or life. Special land forms may require special systems. In areas where there is limited space, rocky soil, or other limitations, mound systems (bring in fill for rocky sites), dosing systems (pumps to overcome elevation restrictions) , sand filter beds (alternative treatment) , and other special systems such as recirculating sand filters and even systems that inject chlorine into effluent for discharge into waterways may be installed. We discuss special systems if we have reason to believe that one is installed at the property being inspected. Different test procedures may be required! See Septic System Design for a wide variety of these alternative septic system designs.

  • Cesspools: explained, design specifications, safety, photos, sketches
  • DRYWELL DESIGN & USES Home Buyer's or Owner's Advice

Types, Causes, and Failure Criteria for Septic Systems: Defining "Failed" Onsite Wastewater Treatment or Disposal

This section lists types of failure of septic system failure by individual system component, the common causes of each septic component failure, and provides defining "septic failure criteria".

More detailed "how to" steps instructing how to inspect specific septic components for signs of failure are discussed at my separate online book chapter in text that compliments material here: How Does Each Septic System Component Fail? If you link to that book-text, please return to the class-text here using your browser's "BACK" button. Otherwise the reader may be confused about where you are, as the text in this class section below appears later in the book text as well.

In simplest terms, there are two visible disposal failures:

  • Toilets or other fixtures back up into the house - but first see "Diagnosing Clogged Drains then return here using your browser's "BACK" button.
  • Effluent or sewage appears at the surface of the yard, or the neighbor's yard!

Septic odors may also indicate a system failure or an imminent failure. But such odors may also be produced by defects in the plumbing vent system or other site conditions. Beware, sewer gas contains methane and is explosive if it reaches a dangerous concentration inside a building.

Typical causes range from things that are easy and cheap to repair, to a need for complete system replacement:

  • Clogged pipes
  • Broken pipes
  • Damaged tank
  • Tipped distribution box
  • Clogged/broken soil absorption piping
  • Clogged absorption soils (grease & solids)
  • Saturated soil absorption area

However there can also be treatment failures. Effluent may not back up or appear on the surface, but if insufficiently treated effluent reaches a private well or any stream or waterway, the environment is being contaminated -- an unacceptable condition. Historically many people have just worried about disposal. As the quality of drinking water deteriorates in many areas and as population grows in many previously thinly-populated areas, proper treatment has become the real concern for everyone's health.

For example, if there is not sufficient soil between the bottom of the soil absorption system trenches and the local groundwater, the local environment is being contaminated.

Other causes of onsite wastewater disposal system failure:

  • Driving over the absorption system, leach field, drainfield
  • Paving over the absorption system
  • Flooding the absorption system with surface or roof runoff, or rocky, poorly-drained or under-sized sites may simply lack capacity
  • Improper original construction , especially on rocky, poorly-drained sites (pipes settle, for example)
  • Tipped or flooded distribution boxes, resulting in uneven loading of soil absorption system lines
  • Use of septic tank or drain field additives which claim to extend system life can generate so much activity in the tank that solids are held in suspension and forced into the soil absorption system! Do not add any treatments, chemicals, yeast, or other treats to a septic system. In general these treatments don't work, may ruin the system, and are illegal in many localities. There is no magic bullet to repair a bad SAS.
  • Rusting steel tank covers can cause death! Rusted covers can collapse. I have reports of children and adults who have died from this hazard, as recently as December 1997. In 2000 I consulted in a fatality involving an adult falling into a cesspool. At a building inspection I myself stepped through a hidden, rusted-through steel septic tank cover. Falling into a septic tank, drywell, or cesspool is quickly fatal, either from being buried by falling soils and debris, or by asphyxiation. Septic gases are highly toxic and can kill in just minutes of exposure. Even leaning over an empty (just pumped) tank has led to collapse and fatality of a septic pumper.
  • Concrete tank lids: can be damaged by vehicle traffic; heavy duty covers are available.
  • Steel tank baffles: rust out and fall off, permitting solids to enter the soil absorption system
  • Steel tank bottoms rust out permitting effluent to leak into soils around the tank, possibly giving a large void in tank at time of testing, thus subverting a loading or dye test;
  • Leaky septic tanks: a septic tank should be water tight. If ground or surface water leak into the tank the result is often a flooded and failed drainfield; if sewage effluent leak out of the septic tank the result is the discharge of inadequately treated effluent into the soils and in the case of a very leaky septic tank, the result may also be a too-rapid loss of effluent in the septic tank resulting in too rapid build-up of solids and total system clogging and failure.
  • Concrete tanks can crack or sections may separate causing leaks with the same effects as just stated
  • Concrete tank baffles: may erode from chemicals, detergents, poor concrete mix, water flowing over top of baffles, or may be broken by improper pumping procedures
  • Houses clustered around a lake: often will have a marginal system as properties were crowded together, built as part-time summer-camps, were built without code supervision, and often were built using amateur, marginal home-made systems.
  • Age: eventually even a well-maintained SAS will clog and have to be replaced.

List of Septic System (Onsite Waste Disposal System) Failure Criteria

Massachusetts Title 5 lists specific failure criteria and serves as a good model for septic inspections anywhere.

  • Backup anywhere in the system
  • Discharge of effluent to the surface, stream, etc. regardless of whether or not septic dye is observed
  • Static effluent level above outlet in the D-box
  • System has to be pumped more than 4x/year
  • Metal septic tanks (municipality dependent; note that in special site conditions small metal tanks may be the "only" solution and may be approved by local officials. An owner/buyer must be informed of the implications of such installations.)
  • Soil Absorption System (or cesspool, etc) is at a depth exposing it to the maximum groundwater level

List of Cesspool Failure Criteria (MA)

  • less than 6" of freeboard
  • less than 1/2 day's storage
  • within100 ft. of a pond or dug well (surface water supply)
  • within50 ft. of a private well (modern sanitary well)
  • between50 and 100 ft from a private well if well fails bacteria test
  • in MA, within Zone 1 of a public well
  • BOH evaluation is required if within 50ft of any surface water

List of Drainfield/Soil Absorption System Failures (leach fields, drain fields, seepage pits)

  • Breakout of effluent observed (& I consider odors as well)
  • BOH evaluation in MA if within 100 ft of surface water supply
  • within Zone 1 of a public well
  • within 50ft of a private well
  • between 50ft and 100ft of a private well if well fails bacteria test.

FAILURE CAUSES - Septic Failure Causes: How Does Each Septic System Component Fail? - What to Look For During a Septic Inspection

This chapter is maintained at SEPTIC FAILURE CAUSES - Septic Failure Causes: How Does Each Septic System Component Fail? - What to Look For During a Septic Inspection, but text is repeated here for readers who scroll down

Before digging up your septic tank or calling a septic pumper, if you think the septic system is failed because of drain blockage or drains backing up into the building, you should to see "Diagnosing Clogged Drains: Is it a blocked drain or the septic system? - A First Step for Homeowners". If you link to that text, please return here using your browser's "BACK" button.

Maintenance Needs of Septic Systems

A principal measure to avoid system failure is periodic tank pumping. Systems can appear to "work" for a long time without maintenance. Modern system failure theory talks about systems that "crash." This means that a system can appear to be ok for a long while but may actually be getting in so much trouble that by the time a problem is noticed it's too late to do anything about it. The system crashes and is beyond repair. When a tank is not pumped sufficiently often there is less settling time for waste entering the tank, so small bits of floating solids are pushed out into and begin clogging the soil absorption system, shortening and eventually ending its life. I've found 9-year old systems which were in total failure for this reason.

Septic Tank pumping frequency depends on these variables:

  • Septic Tank size or capacity
  • The volume of wastewater (number of occupants)
  • Amount of solids in wastewater (garbage disposers)

Table I at Septic Tank Pumping Guide: When, Why, How provides details of tank size in gallons, number of occupants in the building, and tank pumping frequency in years.

Septic tanks will not fail immediately if they are not pumped. However, an un-maintained septic tank is no longer protecting the soil absorption field from solids. Continued neglect may result in system failure and even replacement of the soil absorption field. In some cases, site limitations may make replacement of the absorption field impossible.

Septic System Inspection Safety & Health Concerns:

Before discussing inspecting septic systems, cesspools, septic tanks, drainfields, etc., critical septic inspection safety issues must be reviewed. Making a mistake can result in a fatality for the septic inspector, septic pumper, building occupants, or anyone who has the misfortune to walk over and fall into an unsafe or collapsing system.

  • Do not enter septic tanks/cesspools (fatality reports)
  • Do not lean into septic tanks/cesspools (gas hazards, anoxia, asphyxiation)
  • Note and take appropriate actions regarding unsafe tank covers
  • Special hazards: pumping site-built cesspools, Long Island NY Fatality following Cesspool pump and collapse
  • Special hazards: unsafe covers, collapsing steel tanks and covers, New York near-miss falling into septic tank, potential fatality cases involving children at two sites
  • Septic collapse during exploratory excavation to find equipment
  • Note and take appropriate actions regarding site or building unsanitary conditions (sewage backups)
  • Do not bring sewage-contaminated clothing into your home
  • Tetanus inoculations needed if working in this field
  • Warnings which should be in writing and orally issued to
    1. Septic and cesspool pumpers, workers, installers
    2. Homeowners or building occupants
  • Rope off and prevent access immediately if you detect a collapse risk or unsafe cover. Inform all appropriate parties.

  • Read: Septic System Safety: Septic System, Septic Tank, & Cesspool Safety Warnings for Septic Inspectors, Septic Pumpers, and Homeowners
  • Read: Cesspool Safety Warnings include dangers of cave-in and fatality
  • Read: Septic System Warnings to Home Owners and Home Buyers

SAFETY WARNINGS - Septic Tank Safety Warnings for Septic Inspectors, Septic Pumpers, and Homeowners

This information is maintained SEPTIC & CESSPOOL SAFETY - Septic System, Septic Tank, & Cesspool Safety Warnings for Septic Inspectors, Septic Pumpers, and Homeowners - Excerpts are below.

Providing inspection and diagnosis of on-site waste disposal systems is an extremely valuable public service which helps protect people from expensive unanticipated septic system repair costs and helps protect public health by assuring sanitary disposal of sewage and gray water waste from buildings. More importantly though, such inspections may detect and warn about serious safety hazards at some properties. The strong warnings issued below intend to reduce septic system safety hazards for inspectors and property owners/occupants, but it is not the author's intention to dissuade inspectors from providing this valuable service. But danger lurks at cesspools, open covers, tanks or tank covers in poor condition, and from high levels of methane gas. These risk collapse, falling, asphyxiation, and other potentially fatal hazards as well as risks of unsanitary conditions.

  • Don't work alone: Falling into a septic tank or even leaning over a septic tank can be fatal. Do not work on or at septic tanks alone - workers can become suddenly overcome by methane gas.
  • Do not ever go into a septic tank unless you are specially trained and are wearing the special equipment and gear for that purpose, including self-contained breathing apparatus.
  • Don't enter the septic tank: Never go into a septic tank to retrieve someone who has fallen in and was overcome by toxic gases without a self-contained breathing apparatus (SCBA). if a SCBA is not available, call for emergency services and put a fan at the top of the tank to blow in fresh air.
  • Don't lean over the septic tank openings Do not lean over or stick your head into the septic tank to examine its interior - you could fall in to the tank or become overcome by gases and fall into the tank, an event which is likely to be fatal.
  • Don't ignite flames Do not light a flame at or near the tank - methane gas is explosive. At one tank pumpout my client described the explosion and burns received by the pumping contractor when he stood by the tank and lit a cigarette.
  • Site must be ventilated: Decomposing wastes in the septic tank produce toxic gases (such as methane) which can kill a human in a matter of minutes. When working on a tank be sure the area is well ventilated.
  • Rope off & Mark Dangerous Sites: If your inspection discover that there are dangerous conditions, such as an unsafe tank cover, tank collapse, or a home-made septic tank or cesspool (which are at increased risk of sudden collapse) such areas should be roped off and clearly marked as dangerous to prevent access until proper evaluation and repairs can be made.
  • Safe covers: be sure that the tank and its access ports have sound and secure covers that do not risk collapse and which cannot be removed by children.
  • Septic & Cesspool Collapse Hazards: Old steel tanks, thin, rusting steel or rotting home-made wood tank covers, site-built tanks and cesspools, and recently-pumped cesspools are at particular risk of collapse. Falling into a septic tank or cesspool is likely to lead to rapid asphyxiation from methane and in cases of collapse, there is risk of becoming buried. The author has consulted in cases involving such fatalities (homeowner fell into a site-built cesspool), and at one site inspection, walking near an overgrown area the author himself stepped through a rusting steel septic tank top, surviving only by throwing himself into a nearby clump of brambles! Beware of
    • flimsy, rusted, old-steel, home-made, or missing septic tank/drywell/cesspool covers
    • abandoned systems which may not have been filled-in
    • collapsed, or collapsing septic tanks or cesspools
    • possible presence of multiple components at a property, abandoned or in-use
  • Unsanitary conditions: Be alert for unsanitary conditions such as surface effluent or sewage backups into buildings, events which risk serious viral and bacterial hazards and which indoors, may require professional cleaning. Be alert for personal sanitation hazards when working around septic systems, such as open cuts or failure to wash properly after working on systems.
  • Damage to Septic Components: Avoid damaging septic system components or the building: Improper septic testing procedures, such as flooding a dosing-system, can damage the system. Also, remember to check for leaks into or under the building being tested when running water into the building fixtures and drains. Don't leave water running unattended - at risk of flooding the building.

Septic System Safety Warnings for Home Owners and Home Buyers

Septic system concerns for a building owner start with safety. Here are some red flags:

  • Signs of collapse-possible fatal hazards: include depressions or "soil subsidence" anywhere on or around the property. Any suspect area should be roped-off and absolutely no one should walk over or even close to such a spot until it has been investigated by a professional.
  • Old or abandoned systems: such as site-built cesspools or drywells were often made with a thin steel or wood cover which with age can collapse. If the history of the site or visual observation suggests that there are or were old systems at the property, professional investigation is warranted. Improper "abandonment" (failing to fill-in a pit) can lead to sudden collapses. Signs that there may be old systems at a property might come from anecdotal evidence (ask a neighbor, ask the local septic installing or service companies), or visual evidence such as seeing abandoned waste pipes at basement or crawl space walls or floors. Don't assume that an old house which is now connected to the public sewer didn't previously have an on-site waste disposal system.
  • Septic service by untrained workers: such as aerating, agitating, or pumping out an old site-built cesspool, can lead to sudden system collapse. Prevent access over or near any such systems.
  • Unsanitary conditions such as discharge of sewage effluent to the yard surface, to a nearby well or stream, or previous septic backups into a building deserve professional attention. Indoors special cleaning may be needed to remove bacteria or other pathogens.
  • Septic testing by inexpert "inspectors" who may not follow an adequate procedure increases the risk of a costly surprise.
  • Uninformed homeowners may not notice a danger or malfunction .Homeowners should review the safety warnings listed above. The information here is general in nature. Since conditions and requirements vary widely at individual sites, the you should obtain qualified expert advice pertaining to the specific system about which you have questions, and should not rely on this general text for costly diagnostic/repair/replacement decisions. In other words, I'll try to give you some helpful information. In exchange, don't expect me to pay for your new septic system.

How to Inspect & Evaluate the Condition of Septic Systems - sequence of steps

Septic systems should be conducted in as non-intrusive a manner as possible. Depending on the level of service being provided by the inspector, local conditions, and client/owner requirements, the depth of information collected and extent of testing performed will vary widely. The steps described below give a general outline of types of investigation possible.

Collect Historical Information about the Onsite Waste Disposal System

Collect existing information from owner, realtor, municipality, if available: Original "as approved" or "as built" plans showing system components, layout, type of use, design flow, water use records, service (pumping) and repair records.

Visual Site Inspection of the Septic System:

Examine the site for possible component locations & other clues:
  • On a property by a stream, pond, storm sewer, watch out for "repairs" that extended the SAS into these locations.
  • Look for site problems: rocky areas, wet areas, areas taking surface or roof runoff and prone to flooding, odors, unusual growth, green stripes marking leach trenches, soggy sewage erupting at the surface, signs of recent excavation.
  • If a well casing is visible note its location and distance from actual or most likely septic component locations.
  • Notice dry as well as wet areas; if you perform a loading/dye test you'll want to look for changes anywhere on the property.

Even if you are not performing a septic inspection or test, if you are able to notice obvious signs of failure and fail to report them, you may be considered not to have conducted your inspection with professional diligence in behalf of your client.

How to Locate Septic System Components

We're talking about mostly buried stuff here. Remember that unless you actually find and open an access cover and confirm flow from the house into it, all you're doing is identifying typical or likely component locations in order to assist in understanding the property and to look for signs of failure.

  • Septic Plans: Never assume that the system was installed exactly according to plan. Never assume that components are located in the most likely space unless you have hard evidence. Never assume that a tank cover you see is for a system still in use; it may have been abandoned.
  • Main waste pipe in house indicates only the point of exit and a likely direction for septic components; components may be anywhere, even off the property or actually non-existent! Look for room for a tank and for room for the SAS.
  • Tanks: are often buried close (10' or more) to the building as that's where there is backfill and a place to bury this large object; but they can be quite remote.
  • Rectangular outline, depression, dry or green growth may mark a concrete septic tank; Round outline about 5' in diameter may mark a steel tank. Watch out for unsafe covers!
  • Recent excavations: may mark septic components.
  • Tank covers, cleanout-access ports: may be visible;
  • On a fairly new property one would not expect the SAS to be located on a rocky ridge or amongst dense mature trees where a backhoe would not have been able to pass for excavation.
  • Sewage does not flow up-hill unless there is a pump-system or siphon system installed
  • Basement plumbing: may not empty into the main system - notice the level at which the main waste line exits the building; if it's above basement fixtures and there is no sewage pump system you should be looking for additional septic components.
  • Special equipment: is available to locate pipes and tanks, using snakes and electronic sensors. A septic contractor or plumber in your area may have these tools; even a simple plumbing snake from the main house cleanout can indicate probable distance to a tank.
  • Distances between septic system components and wells, streams, etc. are detailed in my Table of Septic and Well Distances citing various authorities and distances to streams, lakes, farm buildings, etc.
  • Depressions in the ground, especially near a building, may indicate the location of a septic tank; depressions in the drainfield often will mark the locations of leach bed lines, and similarly, a depression in the drainfield area in the shape of a small rectangle may indicate the location of a septic distribution box.

SEPTIC CLEARANCES - Online Table of Required Clearances: Distances Between Septic System & Wells, Streams, Trees, etc.

Details about septic system clearances are at Online Table of Required Septic Clearances: Distances Between Septic System & Wells, Streams, Trees, etc. but text is repeated here for readers who scroll down rather than linking to the separate chapter.

Common guidelines are at least 50' clearance or distance between the well and the septic system tank or 150' between the well and the septic drainfield or leaching bed. Beware that local soil and rock conditions can make these "rules of thumb" very unreliable. See "One and Two Family Dwelling Code, Section P-2510-Combined Seepage Pits and Disposal Fields," and Table P-2504, "Location of Sewage Disposal System." Other references are cited at the end of this table.

Typical clearances for septic tank, soil absorption system (SAS), etc. This table describes distance requirements between septic components and wells, streams, trees, property boundaries, lakes, etc. A second section of the table gives distances from wells to septic systems and other encumbrances. NOTE: these distances are for conventional onsite waste disposal systems which specify clearances presuming that effluent is being disposed-of after minimal treatment such as is received by a septic tank or cesspool. Advanced onsite wastewater treatment systems, such as those described by Jantrania and Gross (2006), permit substantial reduction in these clearances, depending on the level of treatment achieved.

Inspecting Outside Waste Piping

Outside waste piping conducts sewage (black water and gray water) from the building to the treatment tank or "septic tank," and from the treatment tank to the distribution box. These lines should be of solid, non-perforated material and need to be protected from mechanical damage (such as by vehicles). Piping extending from the distribution box into drain fields is normally perforated, though solid lines might be used if effluent is being processed by more specialized devices such as seepage pits, galleys, or a sand-bed system.

House to tank

This line may become blocked by waste, damaged by collapse of a section, or invaded by roots. Detection of these conditions is fairly easy by routing a snake or power snake from the building drain to the septic tank. An experienced power snake operator can often tell by "feel" that a drain line is collapsed, partially collapsed, or invaded by roots. While you may make a temporary "repair" of such a condition by drain-cleaning, if the line is broken or root-invaded, you should expect to have to excavate and replace it soon.

Tank to Distribution Box

The same failures can occur on this line as from house to tank. Opening the D-box can also show whether or not effluent is being directed uniformly into each of the leach lines. A tipped D-box can overload one line and cause early failure of the absorption system. If this is happening, flow adjustment end-caps (eccentric holes) can be installed in the distribution box on the inlet end of each of the drain lines, permitting adjustment of effluent delivery into each line, perhaps relieving the problem line and redistributing effluent into the others.

Drain field piping

In a conventional "drain field" of perforated pipes buried in gravel-filled trenches, a drain line may be invaded by tree roots. This is why experts advise keeping tree and shrub plantings away from drain fields. Vehicle traffic can also collapse this or any outdoor waste piping, which is why experts advise against ever driving over a drainfield or over any other septic system components.

Guide to Performing Septic Loading & Dye Tests

Septic Loading and Dye Testing is a useful, somewhat controversial, and not conclusive test of a system involving placing a tracer dye in a toilet, flushing the dye into the system, and running a reasonable test volume of water (minimum 150 gallons or 50-gallons per bedroom) into the system to look for signs of blockage in the building, backup in the building, or breakout of effluent (possibly dyed) anywhere on or around the property. There is no question that this procedure is useful in that it has disclosed numerous septic failures and has proven that preexisting wet areas did, in fact, come from the septic system. It will NOT find every failure condition. Below I describe the general procedure for performing a loading and dye test of an onsite waste disposal or "septic" system.

A very detailed description of this procedure is at Septic Loading & Dye Test Procedure Details, a chapter of "Inspecting, Testing, & Maintaining Residential Septic Systems"

  • Obtain owner permission. If a buyer has indicated that a septic test is to be performed one might expect the owner to have given permission for a loading and dye test but it's not the case that an owner understands ahead of time what is going to be done. If an owner objects to running water or performing a dye test the inspector should not proceed with the test and should inform the client, including the implications of the situation. A realtor present at the inspection should, by virtue of the realtor agency for the seller, be able to confirm that the septic test is to be performed.
  • Do not perform loading tests on certain systems: dosing systems and recirculating sand bed systems may require that flows into them be limited in volume and time; some systems can be damaged by excessive flooding.
  • Do not permit system pumpout right before testing: an empty tank may be 1000 gallons or more; it will not be filled by a typical loading and dye test, therefore the SAS will not have been loaded at all, and false conclusions may be drawn about the condition of the system.
  • If pumping and tank inspection are to be performed in conjunction with a dye test: the optimum procedure would be to open and inspect the tank at its normal operating condition. The static level liquid in the tank (high, normal, low) may give evidence of a problem that will be masked when the system is flooded. Tank pumping may then be delayed until after the loading test has had opportunity to test the SAS. If there is obvious tank damage (missing baffles, collapsing tank, abnormal liquid levels) the dye test should not proceed.
  • Document: when and where water was run, at what fixtures, for what length of time, at what measured or estimated average flow rate, and at what total volume.
  • Confirm water flow into main waste line: from the fixtures where it is being run. Note piping that may suggest presence of separate drywells and do not use fixtures draining thereto for septic system testing. Document that drywells were not tested if you're not performing additional tests thereon.
  • Monitor water supply equipment during test: if flow declines or stops, be sure to stop the test to avoid possible damage to a well pump.
  • Watch for leaks and backup at fixtures: check each fixture before walking away leaving water running. Ask Douglas Hansen what happens if you don't do this.
  • Inspect: suspected SAS area as well as all property areas for evidence of dye or effluent breakout before and after the test.
  • Check nearby streams, storm drains: for presence of dyed effluent. Dye often appears in 10-20 minutes if there is a gross system failure; however it may not appear for 5 days in some cases.

More Reading about Septic Loading and Dye Tests - Detailed Procedures

  • Dye Amounts, Water Volume: how much septic dye and how much water to use to perform a septic dye test
  • Dye Tests: how to perform a Septic Loading and Dye Test - the complete procedure for septic loading & dye testing, a septic function test
  • SEPTIC FAILURE SPOTS - Where septic system trouble is likely to show up regardless of septic dye testing
  • SPOTTING SEPTIC BREAKOUTS - Spotting Dyed Septic Effluent Breakout Outside - Where Septic Dye is Likely to Show Up During a Septic Dye

Excavating & Pumping Septic Tanks for Further Investigation of System Condition

This task is handled by a septic pumping company or a company working along with a septic system inspector. I schedule the pumper to arrive several hours after starting my inspection so I can do my loading test if one is to be performed. A detailed septic report (such as required by MA Title 5) includes:

  • Description of septic tank: age, size, condition, location
  • Distance between bottom of scum layer and bottom of outlet tee (want 2" or more else need pump)
  • Distance between top of scum layer and top of outlet tee (want 2" or more else need pump)
  • Thickness of scum layer
  • Depth of sludge layer and distance from top of sludge to bottom of outlet tee (want 12" or more else need pump)
  • Evidence of leakage into our out of tank (abnormal liquid top level)
  • Evidence of effluent backup (runs back into tank during pumpdown). Note that a backup due to a plugged line is not a system failure; backup due to leach area (SAS) plug is considered a system failure.
  • Other defects such as damaged baffles and unsafe tank covers.

Inspecting the Septic Tank Condition

Details about septic tank inspection are at Septic Tank Condition - How to Inspect Septic Tanks. Excerpts are below.

The purpose of the treatment tank or "septic tank" is to contain solid waste and to permit the beginning of bacterial action to process sewage into a combination of clarified effluent, settled sludge, or floating scum in the tank. An intact, un-damaged septic tank is normally always filled with these materials. However the inspector performing a "visual" check of the septic system needs to be alert for some important findings:

  • Subsidence at the tank location - may risk dangerous, potentially fatal collapse
  • Evidence of recent work
  • Evidence of backup or effluent breakout at the surface in the tank area

Only by pumping and visual inspection can actual tank capacity and condition be completely determined. Probing in the area of a tank, without excavation, is not recommended as the probe may damage a steel or fiberglass tank. When a tank is uncovered for pumping additional critical details may be observed before the pumping operation

  • Condition and safety of the tank and access covers
  • Liquid and waste level in the tank - evidence of waste passing over the baffles - a flooded system, an indicator of system failure
  • damage to the tank baffles

When the tank is opened and to be cleaned or pumped out additional information is available:

  • Thickness of scum and sludge levels: Septic tank maximum scum and sludge buildup prior to pump out, and instructions for measuring the floating scum layer thickness and settled sludge layer thickness in a septic tank are available in a separate chapter at Septic Tank Pumping Guide
  • Back-flow of effluent into the tank during pumpdown - an indicator of flooded leach fields
  • Additional evidence of damage to the tank baffles
  • Evidence of damage to the tank itself - cracks, leaks

Steel septic tanks

Steel tanks typically last 20-25 years, then rust, and collapse. Before this time steel baffles may rust off (damaging the drain field with sludge) or the tank top may become rusty and unsafe. Since steel tank tops can be replaced while leaving the old tank in place, the condition of the top itself is not a reliable indicator of tank condition.

Rusting steel tank covers can cause death! Rusted covers can collapse. I have reports of children and adults who have died from this hazard, as recently as December 1997. In 2000 I consulted in a fatality involving an adult falling into a cesspool. At a building inspection I myself stepped through a hidden, rusted-through steel septic tank cover. Falling into a septic tank, drywell, or cesspool is quickly fatal, either from being buried by falling soils and debris, or by asphyxiation. Septic gases are highly toxic and can kill in just minutes of exposure. Even leaning over an empty (just pumped) tank has led to collapse and fatality of a septic pumper.

Steel tank baffles: rust out and fall off, permitting solids to enter the soil absorption system

Steel tank bottoms rust out permitting effluent to leak into soils around the tank, possibly giving a large void in tank at time of testing, thus subverting a loading or dye test.

Concrete septic tanks

Concrete tanks at an existing septic installation are usually viable, but might have damaged baffles or cracks that permit seepage of groundwater in or septic effluent out around the tank. Occasionally we've seen tanks made of poor-quality concrete (insufficient portland cement) which eroded badly. If the tank outlet or absorption system have been blocked, examination of the tank interior may show that effluent is or has been above the top of the baffles (see "baffles" below) thus indicating a system failure discussed next.

Concrete tanks can crack or sections may separate causing leaks with the result of not only improper disposal of effluent (wrong location) but also subverting an attempt at a septic loading and dye test since when the system is un-used the tank liquid levels drop abnormally. The inspector may detect this condition only if there is a tank inspection port which is readily and safely accessible for before, during, and after inspection when running a loading and dye test.

Home made or "site built tanks- [TBD]

Site built systems, in my experience, are often under-sized and worse, dangerous. There is a serious risk of collapse of old rotting wood covers, collapsing concrete block dry-laid tank or "cesspool" walls, etc. Other types of tanks and home-made onsite systems are described below at Septic Tank Type, Capacity, Material Details

Baffles: Inspecting the Condition of Septic Tank Baffles

Baffles in a septic tank are provided to keep solids and floating scum and grease inside the tank. Baffles are provided at both the inlet to the tank (from the building) and the outlet from the tank (to the absorption system).

Broken baffles or high sludge levels can cause solids to flow out of the tank and into the absorption system. The result is reduced absorption into surrounding soil and eventual failure of the system. Floating scum thickness and settled solids thickness can be measured through access ports into the tank or cesspool. Finding solids at or covering the outlets or damaged baffles should result in report of a very questionable adsorption system and possible major repair cost.

Concrete tank baffles: may erode from chemicals, detergents, poor concrete mix, water flowing over top of baffles, or may be broken by improper pumping procedures

If baffles are lost or damaged (rusted off on a steel tank or broken off on a concrete tank), they can be repaired or replaced. For example at a steel tank the contractor may simply insert a plastic piping "Tee" into the tank inlet or outlet to create a new baffle system.

However, depending on how long the tank was used without good baffles, the volume of solids and grease that moved from the tank to the absorption system will have begun clogging soils there and will have reduced the future life expectancy of the absorption system.

Baffle damage and repair, or even a complete tank replacement when the absorption system has been left alone always lead the author to warn the building owner that the future life of the absorption system may be in doubt and that additional expense will be involved.

Solids: Inspecting the Level of Accumulated Solids, Sludge and Floating Scum in Treatment Tanks

Solids entering a septic tank are intended to remain there until pumped out during tank service. A large portion of solids settle to the bottom of the tank as sludge. Grease and floating scum remain at the top of the sewage in the tank. Baffles (discussed above) help keep solids, scum, and grease in the tank. Bacterial action in the tank make a modest reduction in the solids volume and begin the processing of sewage pathogens, a step later completed by soil bacteria in the absorption fields.

Net free area: If the sludge level becomes too high or the floating scum layer too thick, in addition to risking passage of solids out of the tank (damaging the absorption system), the remaining "net free area" of liquid in the tank is reduced. When the net free area becomes too small, there is insufficient time for waste entering the tank to settle out as bottom sludge or top floating scum. That is, for an in-use septic tank with a small net free area, the frequent entry of solid and liquid waste will keep the tank debris agitated, thus forcing floating debris into the absorption system where the life of that component will be reduced (due to soil clogging).

The importance of keeping an adequate net free area in a septic tank is the reason that tanks need to be pumped at regular intervals. Building owners who never pump a tank until it is clogged have already damaged the absorption system.

Measuring septic tank sludge thickness & scum layer

Septic tank maximum scum and sludge buildup prior to pump out, and instructions for measuring the floating scum layer thickness and settled sludge layer thickness in a septic tank are available in a separate chapter at Septic Tank Pumping Guide: When, Why, How to Pump A Septic Tank

SEPTIC TANK TIPS - Septic Tank Types, Capacity, Material Details

Septic Tank Types: concrete and steel septic tanks and warnings are discussed above at Inspecting Septic Tank Condition.

Septic Tank Size Requirements and How to Calculate the Size and Volume of a Septic Tank are discussed in a separate chapter, " Table of Required Septic Tank Sizes: Septic Tank Capacity vs Usage in Daily Gallons of Wastewater Flow & How to Calculate the Size (in gallons) of a Septic Tank"

Other septic tank types: might include site-built cesspool using concrete blocks or rubble, steel drums, or other. Beware of very limited capacity, failure to comply with local codes, etc. Steel tanks are at high risk of rust and collapse, and higher risk of loss of baffles; frequently tank cover is damaged by excavation for pumping if no cleanout opening is provided.

Limited Capacity of site-built equipment: Homemade systems are very likely to be in violation of local plumbing codes and standards; significant costs to cure may be involved. Tanks smaller than 900 gallons are below minimum size in some jurisdictions. Areas of wet soils, or very small yards should suggest that there may not be room for a conventional absorption system.

Extra costs will be involved in repairing or extending such installations. Sand-bed filtration systems may have to be replaced with other more costly systems when their operation fails or a use permit expires. Systems that dump into local waterways may require periodic inspection and re-certification by state departments of environmental conservation, or may be outlawed. Use of "drywells" to separate graywater from sewage may be clues of limited system capacity. Graywater may not be discharged to the surface nor to storm sewers.

More Reading:
Septic Tank Pumping Guide which gives the tank pumping schedule as a function of tank size and wastewater usage (or occupants).
Septic System Additives & Chemicals and advice about using them to "help" or "inoculate" or "fix" your septic system.

More Reading About Pumping and Inspecting Septic Tanks

  • Baffles, Septic Tank septic tank baffles defects and inspection suggestions
  • Cesspool Safety Warnings include dangers of cave-in and fatality
  • Septic Sludge & Scum Levels in Septic Tanks - Measuring the Level of Accumulated Solids, Sludge and Floating Scum in Treatment Tanks
  • Septic Tank Inspection Procedure - How to Inspect Septic Tanks and evaluate the septic tank condition, baffles, sludge levels, damage, evidence of septic failure, etc.
  • Septic Tank Location - How to Find the Septic Tank, how deep will the cover be, how to document its location
  • Septic Tank Pumping Frequency Guide for Septic Tanks: When, How, What to Watch For when pumping or cleaning septic tanks
  • Septic Tanks, Concrete defects and inspection suggestions for concrete septic tanks
  • Septic Tanks, Fiberglass or Plastic defects and inspection suggestions for fiberglass or plastic septic tanks
  • Septic Tanks, Steel defects and inspection suggestions for steel septic tanks
  • Septic Tanks, Home Made defects and inspection suggestions for home made or site built septic tanks

Excavating & Inspecting Septic Distribution Boxes

  • Evidence of solids carryover from the tank
  • Leakage in or out of the D-box
  • Flow not moving equally into each distribution SAS line
  • Evidence of backup of effluent: stains showing liquid level has been above the outlet tee - this would be considered evidence of a system failure.

INSPECTING THE D-BOX - Inspecting the Septic System Distribution Box

This chapter is maintained at INSPECTING the D-BOX but text is repeated here for readers who scroll down rather than linking to the separate chapter.

photo of a septic distribution box used to connect the septic tank effluent outlet line to a network of
drainfield pipes The distribution box (more than one may be in use) connects a single effluent line from the septic tank to a network of absorption system components such as drainfield leach lines or to a network of seepage pits or galleys. The photo above shows the adjustable weir outlets that permit balancing flow among drainfield lines. (Source EPA who used photo from Ayres Associates.) More sketches of D-box layouts and configurations are shown in this EPA drawing.

Regulating effluent distribution: In good system design the outlet openings from the distribution box to each drainfield line can be adjusted to regulate the flow among the various absorption lines. Elegantly simple, a plug with an eccentric hole is inserted into the end of each leach line fed from the D-box. By turning the plug in the end of the leach line pipe one can place the eccentric hole higher or lower with respect to the bottom of the distribution box, thus compensating for a slightly tipped box, differences in leach line length, or differences in leach line condition.

Photograph of  a modern concrete distribution box - in this case, stacked up at the manufacturing facility in Kingston, NYUneven effluent distribution: If a distribution box becomes tipped (or clogged) effluent may be routed to only a portion of the absorption system, thus overloading it and leading to a "breakout" of effluent at the surface or to clogging and system backup. An examination of the box interior may show flood lines in the box if the drain field has been clogged or saturated in the past even if at the time of inspection the box is not flooded.

If the fields have been flooded you should be pessimistic about the remaining life of the absorption system. If the box is tipped and/or effluent has not been uniformly distributed among the drainfield lines (assuming they are of equal length and in equally good soils), only a simple adjustment of the outflow may be needed. Round plugs with eccentric openings may be present or can be inserted in the D-box outlet openings to regulate flow among the individual absorption lines. (C)Trap Daniel Friedman Copyright Protected text.

Tipped or flooded distribution boxes, resulting in uneven loading of soil absorption system lines. This condition can flood one or two lines leading to early field failure.

Inspecting the Soil Absorption System of an Onsite Wastewater Disposal System - the Drainfield or Soakaway Bed

The purpose of this component is to perform final treatment of effluent in a conventional or advanced design septic system by permitting treated effluent to flow from the septic tank (or other treatment tank) into the soil. Bacterial action and filtering there remove additional pathogens to bring the discharged effluent to an acceptable level of sanitation, thus permitting its discharge into the environment. "Soil absorption system" is a general term for what people call the "leach field," "leachfield," "drainage bed," "seepage area," "drip area" (usually in newer alternative design systems), "septic mound" "galleys," "drain trenches" or similar terms. If you have synonyms to add to this list, contact me and I'll add it here.

  • Signs of hydraulic failure
  • Condition of surface vegetation
  • Ponding in the disposal area
  • Encroachments into the SAS area (building a pool, for example)
  • Other sources of hydraulic loading in the SAS area (downspouts or area drainage)

INSPECTING FIELDS - Inspecting the Absorption System or Drainfield

Details about inspecting septic drainfields are at SEPTIC DRAINFIELD INSPECTION - Septic Failure Causes: How Does Each Septic System Component Fail? - What to Look For During a Septic Inspection. Excerpts are below.

This article explains types of septic system failure in the drain field, leach field, seepage bed, or similar component. We list the causes of each type of septic component failure, and list the septic component failure criteria or in other words what conditions are defined as "failure"?. The detailed "how to" steps instructing how to inspect specific septic components for signs of failure are discussed in the text above.

Absorption Field Failure Causes of drainfields and leaching beds

  • Soil clogging at the biomat layer which forms below and around the drainfield trenches (or other absorption systems). The biomat is a bacteria layer which forms in soil below and around drainfield trenches where septic effluent or wastewater is discharged. This layer is critical in the processing of fine biological solids and pathogens which are in the effluent, and without it the septic system would not be adequately treating the effluent. Inadequately-treated effluent released into the ground risks contamination of nearby ponds, wells, streams, etc.
  • Driving over the absorption system, leach field, drainfield
  • Paving over the absorption system
  • Flooding the absorption system with surface or roof runoff, or rocky, poorly-drained or under-sized sites may simply lack capacity
  • Use of septic tank or drain field additives which claim to extend system life can generate so much activity in the tank that solids are held in suspension and forced into the soil absorption system! Do not add any treatments, chemicals, yeast, or other treats to a septic system. In general these treatments don't work, may ruin the system, and are illegal in many localities. There is no magic bullet to repair a bad SAS.
  • Improper original construction , especially on rocky, poorly-drained sites (pipes settle, for example)
  • Houses clustered around a lake: often will have a marginal system as properties were crowded together, built as part-time summer-camps, were built without code supervision, and often were built using amateur, marginal home-made systems.
  • Age: eventually even a well-maintained SAS will clog and have to be replaced.

More Reading:
The formation, clogging, and measures to protect and extend the life of the biomat is discussed at Septic System Absorption System Biomat Formation as a subchapter of this text.

DISPOSAL vs TREATMENT - Effluent Disposal and Drain Clogging Failures

In simplest terms, there are two visible septic effluent or onsite wastewater disposal failures:

  • Toilets or other fixtures back up into the house - but first see "Diagnosing Clogged Drains then return here using your browser's "BACK" button.
  • Effluent or sewage appears at the surface of the yard, or the neighbor's yard!

Septic odors may also indicate a system failure or an imminent failure. But such odors may also be produced by defects in the plumbing vent system or other site conditions. Beware, sewer gas contains methane and is explosive if it reaches a dangerous concentration inside a building.

Typical causes range from things that are easy and cheap to repair, to a need for complete system replacement:

  • Clogged pipes
  • Broken pipes
  • Damaged tank
  • Tipped distribution box
  • Clogged/broken soil absorption piping
  • Clogged absorption soils (grease & solids)
  • Saturated soil absorption area

However there can also be septic effluent treatment failures. Effluent may not back up or appear on the surface, but if insufficiently treated effluent reaches a private well or any stream or waterway, the environment is being contaminated -- an unacceptable condition. Historically many people have just worried about disposal. As the quality of drinking water deteriorates in many areas and as population grows in many previously thinly-populated areas, proper treatment has become the real concern for everyone's health.

For example, if there is not sufficient soil between the bottom of the soil absorption system trenches and the local groundwater, the local environment is being contaminated.

SEPTIC FIELD FAILURE CRITERIA - Soil Absorption System Failures: (leach fields, drain fields, seepage pits)

Drainfield life: What destroys or shortens the life of the absorption system?

It's easy to ruin or shorten the life of a drainfield/leaching bed:

  • install a drainfield in wet weather (which compacts the soil)
  • drive over the drainfield or build a parking lot over it (compacts soil, breaks pipes)
  • plant trees on the septic absorption field (roots enter pipes)
  • put a swimming pool in the middle of a drainfield - yes I've seen people do this!
  • forget to pump out the septic tank regularly (solids/grease are discharged into the fields, clogging the soil)
  • direct roof runoff or surface runoff across the drainfield or into the septic tank (flooding the system)
  • install the drainfield in an area of high seasonal water tables (flooding the system)
  • use the septic system to dispose of illegal oils, chemicals, fats, greases - one system in New York near the Taconic State Parkway was connected to house in which was operated an illegal drug manufacturing operation. So much contaminant was flushed down house drains that the workers contaminated their own well and poisoned themselves
  • discharge excessive salts or other chemicals which destroy the The formation, clogging, and measures to protect and extend the life of the biomat is discussed at biomat in the drainfield

Soil Absorption System Failure Criteria

  • Breakout of effluent observed (& I consider odors as well)
  • BOH evaluation in MA if within 100 ft of surface water supply
  • within Zone 1 of a public well
  • within 50ft of a private well
  • between 50ft and 100ft of a private well if well fails bacteria test.

The Drainfield: Leaching Bed Soil Condition & Liquid level

The absorption system or "drain field" has two jobs. First, it disposes of liquid effluent by permitting it to seep into the soil below. Second, a "bio-mat" of bacteria which forms in the soil below the drainage field processes pathogens in the septic effluent to make the effluent sufficiently sanitary as to avoid contaminating nearby ground water.

This distinction between successful "disposal" and successful "treatment" is important to avoid groundwater contamination but has not been addressed by regulation in every municipality. Municipalities which require a minimum distance between the bottom of the drain field trenches (or equivalent component) and the top of the seasonal high ground water table have recognized the importance of a working bio-mat and the need to provide adequate dry soil for it to function.

Even in a well-designed drainage field, eventually the soil surrounding the drainfield device (perforated pipe in gravel trench or other seepage system) becomes clogged with grease and debris. Examining an excavated cross-section of a failed drainfield will often display a black or gray band of sludge and grease of about 1" thickness at the inside perimeter of the gravel trench. When this layer of soil becomes sufficiently clogged the passage of effluent into the soil below is slowed and eventually blocked, leading to the need for replacement. Keeping a tank pumped so as to reduce the passage of debris and grease into a drain field will extend its life.

This is the most expensive problem to correct. Look for septic effluent seepage to ground surface in area of equipment or downhill from such equipment. Look for (illegal) drain field line extensions to nearby streams, storm drains, or adjoining properties where the temptation to "fix" a failing system by sending the effluent to an improper destination overwhelmed a previous owner or repair company. In some areas inspectors use septic loading and dye test. Seepage may be due to overloaded tank, failed absorption system, or blocked/broken piping (may be less costly).

An excavator or septic contractor will often explore one or more drain lines (or similar components) by excavating a portion of it to look for evidence of flooding or soil clogging. We've used a simple probe at the end and along a leach bed to check for flooding of that component. (Be careful not to break or collapse old piping.)

Guide to Septic Drainfield PERC TESTS - Septic Soil Percolation Requirements and Soil Depth Requirements for Septic Absorption Systems / Septic System Drainfields

This chapter is maintained at Soil Percolation Requirements and Soil Depth Requirements for Septic Absorption Systems / Septic System Drainfields but text is repeated here for readers who scroll down rather than linking to the separate chapter.

Perc Tests: What is a septic system soil percolation test?

In specifying the size and type of absorption field (leach field, seepage pits, galleys, other) a septic engineer or health department official will require that a soil percolation test or "perc" test be performed. You may hear it described as a "deep hole test." The first time I participated in this procedure I found myself smiling with surprise at how low-tech the procedure actually was (in New York State.) After identifying the most-likely location on the lot for placement of a septic drainfield, the excavator used a backhoe to dig a rough hole about 5 ft. deep. Happily no groundwater immediately filled in the hole (which would have been bad news).

Perhaps this is why builders try to have this test done in July which is the period of most-dry weather and lowest groundwater table levels. After digging this rough hole, the septic engineer poured a 5-gallon (joint compound) bucket of water into the hole. In some cases a few buckets might be dumped therein.

After that sophisticated move, the observers simply watched the rate at which the water disappeared. a one-inch drop in water level in this hole in three minutes was considered very good. If the water was found still in the hole at no drop in level the next morning, this was considered seriously bad and probably requiring some soil exchange or other special design measures.

What are the soil perc test standards and other soil requirements for septic systems?

I like the Massachusetts Title 5 Septic Inspection criteria for defining a (at least possibly) functional drainfield, as the text explains the role of the biomass below the absorption bed, sets soil depth requirements, and recognizes the importance of keeping the bottom of the working biomass area in well drained soil sufficiently above the seasonal high water table.

Here is an example of soil requirements for a functional drainfield. This version is particularly clearly written and is for residents of Ohio but the principles apply anywhere. "In Ohio, soil absorption systems can be used in areas where the percolation rate of the soil is between 3 and 60 minutes per inch (soil permeability between 1 and 20 inches per hour).

At least 4 feet of suitable soil is required under the soil absorption system to provide adequate treatment of the septic tank effluent. To accommodate the construction of the system and provide adequate soil cover to grade, a minimum of 5 1/2 to 6 1/2 feet of suitable soil is needed above the limiting layer.

A limiting layer may be bedrock, an impervious soil layer (hardpan, fragipan) or a seasonally high water table (gray soil or mottles). The soil absorption system must be at least 8 feet from any drain line on the lot, 50 feet from a water supply, and 10 feet from the property line, right-of-ways and the house. Septic systems cannot be placed on the flood plain and are limited to areas with less than a 15 percent slope." http://ohioline.osu.edu/aex-fact/0743.html Ohio State University Fact Sheet "Septic Tank - Soil Absorption Systems"

Our separate article by Lockwood includes a description of the calculations to answer the question: How Big Should the Leach Field Be? and includes a practical example using sample calculations and a table of soil percolation rate vs. field size

FIELD SIZE - Septic Leach Field or Septic Absorption Field Size: How large does the absorption field need to be?

Details about determining septic drainfield size or soakaway bed size are at SEPTIC DRAINFIELD SIZE. Excerpts are below.

The size of the absorption field needed (in square feet of area, presumably also unencumbered by trees, driveways, buildings, etc.) can range considerably depending on the soil percolation rate. A lot with a good percolation rate or "perc" of perhaps one inch of percolation in three minutes might require about 4500 square feet for a typical three bedroom home. If the same home were built where there was a poor a soil percolation rate of an hour per inch, 9000 square feet or more might be required for the absorption area.

Drainfield size and location also have to take into account local zoning - setback requirements from property borders, setbacks from streams, wetlands, wells, water supply lines, and other encumbrances.

More Reading:
How Big Should the Leach Field Be? includes a practical example using sample calculations and a table of soil percolation rate vs. field size
Design Basics for Septic Systems: Choosing Septic Tank Size, Leach Field Size - basic septic system volume and absorption system design guides.

Drainfield trench/line specifications

In the most common design of drainfield, perforated pipes are buried in gravel-filled trenches to form the drainfield. Pipes are placed across the slope line of sloped property (so that all of the effluent doesn't simply rush down to and leak out at the end of the drain line pipe). While some experts describe the bottom of these trenches as "level" in practice they are dug to slope slightly, perhaps 1/8" per foot or less.

A typical septic leach field trench is 18 to 30 inches in depth, and 8 to 12 inches wide. The trenches are dug about 6 feet apart which allows, in good design, space for a set of replacement trenches to be placed between the original ones when the first set fails. The maximum length of a trench is typically about 150 feet but I've found installations that were three times that length.

Where lot space does not permit drainfield trenches such as I've just described, a septic engineer may specify that seepage pits or galleys are to be installed. These fit in a smaller space since a single pit may be 6' to 8' in diameter. But the depth to which effluent is being delivered (4' or more) means that the sewage effluent is unlikely to be fully treated by a biomass. These systems may successfully "dispose" of effluent but they are probably not adequately "treating" it.

[See Tables for sizing drainfields and mound systems, USDA, soils, guide to Soil percolation tests, trench dimensions, loading in gpd per foot. e.g. , moderately limited perc rate of 5-10 min/inch has max sewage loading rate to trench and bed bottom of 1 gallon per square foot per day per trench and .5 gal per bed.

The Biomat: The formation, clogging, and measures to protect and extend the life of the biomat, or organism layer below and around soil absorption system effluent discharge piping is discussed at Septic System Absorption System Biomat Formation as a subchapter of this text.

MOUND SYSTEMS - Septic mound systems

Details about septic mound systems are at MOUND SEPTIC SYSTEMS. Excerpts follow.

To build a mound system, extra soil is brought to a site and sculpted to form a drainfield of adequate thickness and area. These systems are common where soils are rocky or where there simply is not enough soil above the local water table to provide adequate absorption.

A mound system may be fed by gravity at some sites but it's also common for the effluent to reach the mound by having been "pumped-up" from a septic tank. Pump-up (to elevations higher than the building main drain exit) and some septic mound systems use a single or duplexed pump either in a clear baffled section of the tank, or in a separate effluent pumping chamber. Duplexed systems offer more reliability. If the first pump fails the second takes over, and an alarm bell or light are turned on.

Grinder/Ejector pumps are used at both private and public sewage disposal systems to pump up from low areas (such as a basement toilet) where the sewer line exits the building at a higher level and where gravity drains are therefore not workable. Flush-up toilets, systems that use a venturi-system rather than a grinder pump, may be encountered but may be in violation of local plumbing codes as they may comprise an unsanitary cross- connection (using house water pressure to force sewage up and out).

What ruins a septic mound system?

A good way to ruin a septic mound system or to build one with a short life is very common in the Northeastern U.S. where I find what I call "pseudo mound septic systems" in which the builder has killed two birds with one stone. Instead of clearing an area and bringing in the proper volume and type of soil to build the mound, the builder finds a spot into which s/he can push all of the tree stumps and construction debris from the building project.

The stumps and trees are then buried with backfill to produce an nice looking "mound" with just enough soil to bury a network of drainfield pipes. If you see a mound system that has horizontal trees sticking out of its base, or if it has mysterious pipes leaving its base, I would be very suspicious about the design and longevity of the system, as well as concerned about its legality.

Septic Pumps and Alarms for Septic Tanks and Mound Systems

[TBA] Additional data on this topic for Canada: see Ministry of the Environment, Class 4 Sewage Systems, on hand via AC

More Reading about Septic Mounds

SEPTIC MOUND SYSTEMS as Components of Alternative Septic Systems for Difficult Sites
Mound System Installation and Design Details from New York State Septic System Design Regulations 75-A.9 Alternative Septic Systems.
Ohio State University has a nice web page describing Septic Mound Systems.

CESSPOOLS for onsite wastewater disposal

See CESSPOOLS for details about these systems. Excerpts are below.

Photograph of  a modern concrete seepage cesspool or seepage pit A cesspool combines the septic treatment tank and absorption system into a single component. Basically a cesspool is a stone or concrete block or (safer) pre-cast concrete (photo) lined pit into which sewage is discharged. Solids remain in the pit, effluent is absorbed into soil below and at the sides of the cesspool. This older design was often used where there is limited physical space, and where the soil absorption rate high. We have more to add to this section, but the bottom line is that for most installations you should consider this an obsolete, limited capacity system likely to need replacement, and involving significant cost. Some immediate concerns are stated next.

Cesspool Safety Warnings

  • Safety Warning: do not walk over the top of or close to the edges of a cesspool or any other onsite pit or excavation because of the danger of fatal collapse. Keep pets and children away from such systems.
  • Safety Warning: there is a high risk of cesspool collapse, risking fatality if someone falls in to one of these systems. This is particularly true for older site-built systems that were often made of dry-stacked stone or concrete block, and more-so if such systems are not protected by a very secure cover.
  • Safety Warning: pumping cesspools is dangerous since older site-built systems may be more likely to collapse inwards when relieved of their contents.
  • Safety Warning: aerating or agitating sludge at the bottom of a cesspool in an attempt to renew its function or extend its life also risk system collapse.

Cesspool Failure Criteria (MA)

Failure Criteria for Cesspools: If the waste level is within 12" of the inlet pipe near the top of a cesspool the system is at end of life and needs to be replaced. Some municipalities and experts will state other distances. In Massachusetts according to the Massachusetts Title 5 Septic Law the following are considered a failed or unacceptable cesspool installation:

  • less than 6inches of freeboard
  • less than 1/2 day's storage
  • within100 ft. of a pond or dug well (surface water supply)
  • within50 ft. of a private well (modern sanitary well)
  • between50 and 100 ft from a private well if well fails bacteria test
  • inMA, within Zone 1 of a public well
  • BOH evaluation is required if within 50ft of any surface water

Drywells for Graywater Disposal: Warnings

A drywell, or "seepage pit" is used at some building sites to receive "gray water" from a laundry, sink, or shower.

The pit may be site-built of stone or dry-laid concrete block, rubble-filled, or constructed of (safer) pre-cast concrete. Design may be similar to that of a cesspool, described above, but only gray-water and not sewage is discharged into a drywell.

  • Safety: the same concerns for collapse hazards apply as were described above for cesspools.
  • Limited septic system capacity is implied by the presence of a drywell. Wet soil conditions or limited space for a functioning drain field (for the septic system) often leads property owners to reduce the liquid load on the septic system by routing gray water to a separate drywell. Where such a system is installed owners/buyers should be alert for these conditions and should expect to face extra costs for system maintenance and repair as well as limited septic system capacity.
  • An exception to the warning above: at a large building where a sink or laundry are added in an area distant from piping connected to the septic system, an owner may add a remote drywell as an alternative to inconvenient and costly routing of a drain line from the laundry to the existing septic system.

DRYWELL DESIGN & USES in many areas are a misnomer since during wet weather as water tables rise, the "drywell" is not very dry and in fact may fill up with water and simply stop working.

In wet areas of the Northeastern U.S., for example, I disagree with the practice of "solving" a roof drainage disposal problem at a flat site by building a "drywell" since in my experience these fail rather soon and in some cases even fill up and work backwards, sending water back to a building footing drain or roof drainage system where water then leaks into the building!

Details about drywells are found at Septic Drywells

Recent & Future Trends in Onsite Waste Disposal Systems

Concern for Water Quality is increasing

Text under revision.

Effluent Disposal vs. Treatment

In many states including my own New York, focus has traditionally been on successful "disposal" of effluent which has received Level-1 treatment by a septic tank. Successful onsite wastewater "disposal" means we don't see the waste water on the surface of a property and that a dye test does not detect it being discharged into nearby surface streams or lakes. But successful onsite wastewater treatment means we are not contaminating the ground water. The Massachusetts Title 5 Septic Inspection standards and procedures make this distinction but many states have not adopted such rigorous standards (as of January 2006).

Legislation & Mandated Upgrades

Alternative and Advanced Onsite Waste Water Treatment & Disposal Systems are Available

A "conventional" septic tank and drainfield just won't work at some sites for reasons like these:

  • The site is too rocky for a conventional septic system or perhaps there is no soil at all.
  • The site is too small for a conventional septic system
  • The site is too wet for a conventional septic system
  • The site is too dry for a conventional septic system
  • The site is too steep for a conventional septic system
  • The site is too close to a lake or stream for a conventional septic system
  • The community or occupants cannot afford a conventional nor an expensive alternative septic system design.

There are solutions for most site problems, including septic handling and wastewater treatment systems that can fit in a very small space and operate completely above ground. Alternative septic system designs and products have increased significantly in number in the past 20 years as experts have experimented with media treatment systems and alternative materials for treatment, septic tanks, and soil absorption or even evaporation systems. Systems that use no water or only very little water, and very important, systems that re-use graywater from a site have been designed. We have published a large article series describing a variety of alternative septic system designs and also have collected reference sources: books, government resources, online articles. These articles and resources for alternative septic system designs are organized and listed at ALTERNATIVE DESIGNS.

Global Warming and Onsite Waste Disposal Issues

12/4/2006: different areas will experience quite different concerns as weather conditions, sea levels, and soil moisture are amended by the effects of global warming in the coming century, or perhaps much sooner.

  • Areas of Rising Sea Level and Effects on Septic Systems: Rising sea levels will saturate soils and make conventional in-soil disposal and treatment ineffective, raising serious health concerns for very large populations of the earth who currently live at or close to sea level and in coastal areas.
  • Amended Weather Patterns Resulting in More Rain and Effects on Septic Systems:: may occur in some areas as both sea currents (Gulf Stream) relocate and air currents (Jet Stream) relocate. Areas of increased rainfall resulting in increased soil moisture levels will reduce effluent disposal capability of conventional septic systems in those areas and may interfere with treatment of effluent in the biomat.
  • Amended Weather Patterns Resulting in Less Rainfall and Effects on Septic Systems: areas becoming very dry may ease effluent disposal in soils up to a point. But soil pathogens necessary to form and function as the biomat that treats septic effluent require soil moisture. Too-dry soils may interfere with successful treatment.

Septic System Design Improvements and Products

  • New materials and products for septic tanks permit systems to be installed where there is no soil perc, or no soil at all. Wastewater treatment systems are available which also can significantly reduce the distance required between septic components and wells, streams, lakes, etc.
  • See Jantrania & Gross, Advanced Onsite Wastewater Systems Technologies
  • Advanced onsite wastewater treatment system types discussed in the above text include the following:
    • Aerobic treatment units
    • Media filters, single pass and recirculating
    • Natural systems for polishing or recycling secondary effluent
    • Waterless toilets, graywater systems, alternatives to flush toilets
    • Disinfection systems

Septic Inspector Qualifications/Licensing

If you perform septic inspections you are obligated to do so with proper information, training, procedures, and in some communities a license is required. Some states (e.g. CA, CT, NJ, MA) have specific certification requirements for inspectors of septic systems, as well as specific regulations regarding the performance of the inspection itself.

Be sure to obtain information pertinent to your own state, usually from the state health department or state department of environmental protection. For example, Massachusetts septic inspectors will want to look at the links and the Title 5 regulations at our page on the Massachusetts Septic Testing Law. Other links to septic system installation and inspection regulatory agencies are at our "Local, State, U.S. Federal Government, & International Agencies & Resources for Septic Systems Wastewater Treatment" page.

Septic System Inspection Authorities

see SEPTIC AUTHORITIES, DESIGN REGS - excerpts follow.

INSPECTION AUTHORITY: some municipalities and states (EG. Pennsylvania) provide septic inspection and testing certification. However a generalist inspector such as an ASHI professional, in the course of a home inspection, is permitted to observe and report visual evidence of defects, probable, or possible defects, just as any contractor might observe and report when coming to a property for any reason.

For municipalities requiring certification of septic test providers, home inspectors should consult with local officials for further advice.Note: some authorities, such as New Jersey Administrative Code 7:9-3.17 (b)5 require septic system evaluations to be performed only by a licensed professional engineer, licensed health officer, licensed sanitary engineer, or trained technician under supervision of the septic system inspector as defined in the pertinent code.

However our review of these codes finds them probably unenforceable since in some instances the codes contradict themselves (see quote below) or the code agencies provide homeowner pamphlets calling for annual inspections which are made by the homeowner him or her self. "All testing of operating systems which requires a hydraulic loading which is in excess of the design flow shall be performed under the supervision of a licensed professional engineer." (New Jersey EPA, Sub 12, 7:9A-12.7 System Testing.") Some codes also require that the details of the septic evaluation procedure itself be included in the report. [Information courtesy of Ed Fitzgerald, ASHI.]

Definitions of Levels 0-1-2-3 of Septic System Inspection and Testing

Details about levels of septic inspections are at SEPTIC SYSTEM INSPECTION LEVELS Excerpts are below.

Anyone inspecting septic systems MUST be familiar with the hazards and safety concerns discussed at SEPTIC SYSTEM SAFETY WARNINGS

LEVEL-0 Septic Inspections - Basic Visual or Visual Plus Loading & Septic Dye Test - no pumping

This level of inspection is typically provided during a "home inspection" for real estate transactions. It pumping may not be appropriate if the system is a recent installation (less than 2 years old), or if it has been recently pumped (a year or less, perhaps more depending on tank size and building occupancy), and if there are not other historical or site observations raising question about the system condition.

  1. VISUAL ONLY: Basic visual inspection and reporting of information (Performed by home inspector or other expert) (Some municipalities require this test be performed only by specifically licensed septic contractors or engineers.)

  2. VISUAL PLUS LOADING DYE TEST - Visual + Dye test and system loading. Warning: using an inadequate amount of tracer dye or an insufficient volume of water for this test will make it meaningless. Therefore ordering a "stand-alone" septic loading and dye test of a system should be expected to cost considerably more than such a test which can be performed overlapped in time with other building inspection services. Beware of quick, minimal tests which place only a small volume of liquid into the system (perhaps 50 gallons over 10 or 15 minutes).

LEVEL 1 Septic Inspections: Level 0 plus open accessible covers, plus Loading/Dye Test, possibly Pumping

This inspection is comprised of:

  1. The steps in a Level 0 inspection
  2. Additional visual inspection steps to open accessible covers & inspect equipment.
  3. Septic Dye Test: This inspection usually include a septic loading and dye test. If a dye test is to be performed it must be done before the system is pumped or further inspected - otherwise the loading test cannot test the absorption system.
  4. Pumping: In some states such as Pennsylvania, this level may include requiring tank pump out and inspection. (Performed by home inspector or other expert) (Some municipalities require this test be performed only by specifically licensed septic contractors or engineers.) This is the Pennsylvania PSMA definition for level-1. More detail is at Level 1.

LEVEL 2 Septic Inspections: Level 1 plus scum and sludge levels, pump tank, check D-boxes

This inspection is comprised of:

  1. The steps in a Level 0 inspection
  2. The steps in a Level 1 inspection
  3. Additional steps to:
    • locate, excavate if needed, open, inspect the septic tank
    • determine the septic system capacity, scum thickness, baffle condition, etc. (Performed by septic pumping contractor or other expert.) (Some municipalities require this test be performed only by specifically licensed septic contractors or engineers.) More detail is at Level 2.
    • pump and inspect the emptied septic tank, baffles
    • locate, excavated if needed, and inspect the distribution boxes

LEVEL 3 Septic System Inspections Level 2 plus soil and perc tests, poss. engineering analysis

This inspection is comprised of:

  1. All of the steps in a Level 0,1, and 2 inspection
  2. Additional site excavation to make test openings in leaching area, other test holes to observe soil conditions, test the soil percolation rate, and if needed, perform other engineering work necessary to certify an existing system or to permit specification of system replacement. (Performed by septic pumping contractor, engineer, or other expert.) (Some municipalities require this test be performed only by specifically licensed septic contractors or engineers.)

How to Perform a Septic Loading & Dye Test

The septic loading and dye test procedure, data to be recorded, and minimum quantities of water and septic dye needed are discussed in a separate chapter at Septic Loading and Dye Test Procedure Details - a chapter of this text "Inspecting, Testing, & Maintaining Residential Septic Systems".

Septic Dye Test Warnings to be Included With Septic Test Reports

  1. If property has been vacant more than a week or the system has been only minimally used, additional levels of testing and inspection are necessary to determine system condition. If the system has been serviced recently, contact the septic pumping company to inquire about the type and condition of the waste disposal equipment. If the system has not been serviced recently, limited but important additional information regarding the condition of the system may be obtained by having a septic contractor open, clean, and inspect the septic tank (and distribution boxes). Particularly in the case of older systems that have not been serviced, if the property owner will permit this step we recommend it. Excavation and pumping are beyond the scope of our loading and dye-test procedure. Practices in some states require pumping and inspection at sale.
  2. Septic systems are basically a "buried" installation which is hidden from normal visual inspection. Many possible problems may not show themselves at the time of a visual inspection, and thus one cannot make accurate prediction of the future condition of the system. Determination of location, condition, or life expectancy of buried septic components is not possible from a visual inspection. Costly problems may not be visible.
  3. Periodic pumping is recommended to prevent costly damage to the absorption system. Pumping frequency depends on system usage, tank size, and other factors.
  4. The inspection includes visual examination of probable tank and absorption system areas, surface and perimeter, at the beginning, during, and at the end of a loading or dye test, if such was ordered and performed.

Sample Septic Inspection & Test Reports

Here are links to examples of field data collection sheets used in preparation of a septic inspection report Examples of final, written septic inspection and testing reports are available and can be provided on request to the author.

  • SEPTIC SYSTEM INSPECTION LEVELS - include data collection forms & checklists for each septic inspection level
  • SEPTIC INSPECTION WORK SHEETS - data collection forms for septic system inspections
  • SEPTIC TANK INSPECTION PROCEDURE - what sorts of tank failure evidence can be seen & reported
  • SEPTIC DRAINFIELD INSPECTION - what evidence of drainfield failure can be seen & reported
  • INSPECTING SEPTIC D-BOX - problems found & reported at the septic distribution box
  • SEPTIC DRAINFIELD INSPECTION - what signs of drainfield or soakaway bed failure can be observed & how are they reported?

Frequently Asked Questions (FAQs) about septic inspection & testing

...


Frequently Asked Questions (FAQs)

...

Ask a Question or Search InspectApedia

Questions & answers or comments about how to inspect or test septic systems, septic inspection procedures, septic failure criteria, and septic inspection results reporting.

Ask a Question or Enter Search Terms in the InspectApedia search box just below.

Technical Reviewers & References

Related Topics, found near the top of this page suggest articles closely related to this one.

  • The complete set of septic system inspection, testing, design, and repair references is maintained at SEPTIC REFERENCES.

    1. "EPA Design Manual: Onsite Wastewater Treatment and Disposal Systems," R. Otis et al, EPA 625/1-80-012. GPO Bookstore, 26 Federal Plaza, Room 110, New York NY 10278 212-264-3825.
    2. "Septic Systems," T. & A. Ferrero, Tri State ASHI Seminar, November 6-7 1993, and attachments listed below.
    3. "Septic Tank Pumping," Paul D. Robillard, Kelli S. Martin, Penn State College of Agriculture, Cooperative Extension, Agricultural Engineering Fact Sheet SW-161, Agricultural Engineering Department, 246 Agricultural Engineering Building, University Park PA 16802 814-865-7685 814-863-1031 FAX.
    4. "Preventing Septic System Failures," Paul D. Robillard, Kelli S. Martin, Penn State College of Agriculture, Cooperative Extension, Agricultural Engineering Fact Sheet SW-162.
    5. "Mound Systems for Wastewater Treatment," Paul D. Robillard, Kelli S. Martin, Penn State College of Agriculture, Cooperative Extension, Agricultural Engineering Fact Sheet SW-164
    6. "Septic Tank Soil Absorption Systems," Paul D. Robillard, Kelli S. Martin, Penn State College of Agriculture, Cooperative Extension, Agricultural Engineering Fact Sheet SW-165
    7. "The Soil Media and Percolation Test," Paul D. Robillard, Kelli S. Martin, Penn State College of Agriculture, Cooperative Extension, Agricultural Engineering Fact Sheet SW-163
    8. "Level 1 Septic System Inspections During Real Estate Transactions," Paul D. Robillard, Kelli S. Martin, Penn State College of Agriculture, Cooperative Extension, Agricultural Engineering Fact Sheet SW-166
    9. "Take Care of Your Septic Tank," Washington State Septic Tank Pumpers Association, (WSSTPA) (Les Eldredge, President, 206-334-8263); Courtesy of Bob Kelwitz, 10/93. Items 3-9 provided courtesy of Jules Falcone.
    10. "Cottage Country, Environmental Manual for Cottages," 6th Ed., 1989, ISBN 0-7729-5085-7, Environment Ontario, 135 Clari Ave. West, Suite 100, Toronto Ontario M4V 1P5
    11. Septic Tank Maintenance," Circular 1343/January 1990, and "Why Do Septic Systems Fail?," K. Manci & J.A. Moore, Extension Circular 1340/January 1990, Oregon State University Extension Service, and "Know your Septic System," a home buyer's guide to on-site septic systems, Washington Association of Realtors, Govt. Affairs Dept, PO Box 719, Olympia WA 98507 206-943-3100, provided by Len Sherr, Bend OR
    12. One and Two Family Dwelling Code, Section P-2506, Septic Tank Design and Construction.
    13. "The Septic Tank Home Wastewater Treatment and Disposal System," Southern Rockingham Regional Planning District Commission, 19 Main St., Salem NH 03079 603-893-5766
    14. "Septic Tank News & Views," Stanley Carraway, Florida ASHI Seminar, October 9-10, 1993 available from FLASHI Chapter, includes some USDA tables and charts on design, loading, and references the New (1992) Chapter 10D-6, Florida Administrative Code, Standards for Onsite Sewage Disposal Systems.
    15. Pennsylvania Septic Management Association, RD 3 Box 3231, Moscow, PA 18444
    16. HUD Handbook 4910.1 (Well Clearances)
    17. "Private Sewage Disposal, Some Suggestions," RES-I-TEC, 145D Grassy Plains St., Bethel CT 06801 1989
    18. "A Homeowner's Manual for Septic Systems," Robert Berg, Wastewater Facilities Management Element Bureau of Construction and Connection Permits, State of New Jersey Department of Environmental Protection, Division of Water Resources, January 1990, 609-984-4429, courtesy of Lewis Home Inspections
    19. "What Remodelers Should Know About Septic Systems,", Russ Lanoie, Journal of Light Construction [New England Builder], July, 1988, p. 31-36, RR#2, PO Box 146, Richmond VT 05477
    20. "Water Conservation and Wastewater Disposal," R. Siegrist et al., 1978, ASAE Pub. 5-77:121-136
    21. "Soil Infiltration Capacities as affected by septic tank effluent application strategies. In: Proceedings of the 3rd national Symposium on Individual and Small Community Sewage Treatment." ASAE Pub. 1-82 pp. 72-74. ASAE PO Box 410, St.Joseph MI 49085
    22. "Aerobic on-site systems studied in New Mexico," Asbury R. and Hendrickson C., 1982, Journal of Environmental Health, 45:86-87
    23. "Soil Clogging: Mechanisms and Control," R. Otis, Proceedings of the 4th National Symposium on Individual and Small Community Sewage Treatment, ASAE Pub. 07-85 pp. 238-250, ASAE, 2590 Niles Rd., St. Joseph MI 49085-9659
    24. "Residential Graywater Management in California," A. Ingham, 1980. California State Water Resources Control Board, PO Box 100, Sacramento CA 95081
    25. "On-site disposal of small wastewater flows," R. Otis, 1977, Department of Civil and Environmental Engineering, University of Wisconsin, Madison.
    26. NAHB Library, several resources listed, contact NAHB, 15th and M Streets NW, Washington, DC 20003 202-822-0203. "Pumped septics - improved waste-water systems distribute effluent from septic tanks over a wide area, preventing contamination of drinking water," Noele Stuart, Popular Science, My 1989, p. 84; "Septic tank effluent pump systems: an alternative to conventional sewers and grinder pump systems," Small Flows, October 1991, p 4. Courtesy of Heather Groves, NAHB Library and Information Center. 800-368-5242 Ext 204 (CD ROM search service, fees involved, for GTHBA members and NHBA members)
    27. "Septic Tank/Water Softener, potential effects of water softener use on septic tank soil absorption on-site wastewater systems; the effect of home water softener waste regeneration brines on individual aerobic wastewater treatment plants," Water Quality Research Council, Water Quality Association, 477 E. Butterfield Road, Lombard IL 60148
    28. "Design Handbook, Grinder Pumps, Low Pressure Sewer Systems," Environment One Corporation, 2773 Balltown Road PO Box 773, Schenectady NY 12301 518-346-6161 (Richard C. Grace, Sales Mgr.)
    29. "What you should know before buying a home served by a septic system," State of Connecticut, Department of Health Services, 150 Washington St., Hartford CT 06106, via Allspect, Westhaven CT and Butterly's Building Inspection Service, CT.
    30. "Soil infiltration capacities as affected by septic tank effluent application strategies," D.L. Hagett, et al, 1982, In: Proceedings of the 3rd National Symposium on Individual and Small Community Sewage Treatment." ASAE Pub. 1-82, pp. 72-84. ASAE, PO Box 410, St Joseph MI 49085, current address: ASAE, 2950 Niles Rd., St Joseph MI 49805-9659, courtesy of Bob Stead, ASHI.
    31. "Aerobic on-site systems studied in New Mexico," R. Asbury and C. Hendrickson, Journal of Environmental Health 45: 86-87,
    32. "Soil clogging: mechanisms and control," R. Otis, 1985, in National Symposium on Individual and Small Community Sewage Treatment." ASAE Pub. 1-82, pp. 238-250.
    33. "Residential Greywater Management in California," California State Water Resources Control Board, PO Box 100, Sacramento CA 95801
    34. "EPA Design Manual: Onsite Wastewater Treatment and Disposal Systems," R. Otis, et al., No. EPA-625/1-80-012 (or later edition if avail.)
    35. "On-site disposal of small wastewater flows," R. Otis, Dept. of Civil and Environmental Engineering, University of Wisconsin, Madison WI
    36. Private communication and "Private Sewage Disposal System," septic
          checklist developed for ITA, Inspection Training Associates, Kevin
          O'Malley, 1016 S. Tremont Street, Oceanside CA  92054, 800/323-9235
         Private communication, K. Oberg to DJ Friedman,  12/15/93, 12/16/93, 7/22/94
         Private communication, J. Appleby to DJ Friedman, 9/16/93, Venice FL
         Private communication, D. Barnett to DJ Friedman, 9/15/93, Evansville IN
         Private communication, N. Becker to DJ Friedman, 9/15/93
         Private communication, E. Fitzgerald to DJ Friedman, 9/94, Adoption of New
      Jersey environmental protection law addressing septic system operation and
      maintenance, Subchapter 12, documented in New Jersey Register, 8/21/89, Cite 21
      NJR 2635. Requires annual inspection beginning in 4th year after construction,
      describes acceptability criteria, inspection steps, conditions of failure.
         Private communication, T. Moore to DJ Friedman, 1/15/94, "Private
          Septic System Evaluation," Goshen NY, 914-294-3398
         Private communication, S. Vermilye to DJ Friedman, 1/15/94, and
          sample checklist, 914-255-8888.
         Private communication, D. Surette to DJ Friedman, 5/6/94
         Private communication, R. Klewitz to DJ Friedman, 10/1/93
         Private communication, L. Scherr to DJ Friedman, 10/1/93,
          Cascade Home Inspection, Bend OR
         Private communication, G. Reid to DJ Friedman, 12/6/93
         Private communication, G. Carroll to DJ Friedman, 11/29/93,
          Action Inspection Service, Cincinnati, OH
         Private communication, R. Johnson to DJ Friedman, 11/5/93,
          The Home Specialist, Inc., Roswell GA
         Private communication, E. Rawlins to DJ Friedman, 10/7/93, Boca Raton FL,
      and "You and Your Septic Tank, a guide to the proper operation and maintenance
      of a septic tank system," Department of Natural Resource Protection, 500 E.
      Broward Blvd, Suite 104, Fort Lauderdale FL 33394 305-765-5181,
          Broward County, FL, January 1993
         Private communication, R. and B. Williams to DJ Friedman, 11/20/93,
          Williams Home Inspection Co, Hollis NH
         Private communication, A. Carson and R. Dunlop to DJ Friedman, 2/6/92,  11/10/93
         Private communication, L. Cerro to DJ Friedman, 8/22/93
         Private communication, R. Passaro to DJ Friedman, 9/15/93, 10/15/93,
      Res-I-Tec Corp., Bethel CT; also see Passaro's "Private Sewage Disposal, Some
      Suggestions," NY Metro ASHI Seminar, October 1993 (cc on hand)
         Private communication, J. Falcone to DJ Friedman, 10/15/93
         Private communication, C. Greenberg to DJ Friedman, 9/9/93
         Private communication, V. Faggella to DJ Friedman, 9/14/93,
          9/24/93, Yorktown Heights, NY
         Private communication, R. Stead to DJ Friedman, 9/20/93, Charlton MA
         Private communication, T. Lewis to DJ Friedman, 9/20/93,
          Lewis Home Inspection, Lawrenceville NJ
         Private communication, G. Guarino to T. Lewis, 12/12/91, Septic system
      failure and inspection limitations, Township of Hopewell, Department of Health,
      201 Washington Crossing, Pennington Rd., Titusville NJ  08560
         Private communication, C. Eldredge to J. Falcone,  3/27/91, Septic
      Certification and Testing Information from the Pennsylvania Septage Management
      Association, Curt Eldredge, General Manager, Wastewater Management, Inc., West
      Chester PA  19380  215-436-4045.
          
    37. Wells and Septic Systems, 2nd Ed., Max and Charlotte Alth, Rev. by S. Blackwell Duncan, Tab Books, 1992 ISBN 0-8306-2137-7
    38. Onsite Wastewater Treatment Systems, Bennette D.Burks, Mary Margaret Minnis, Hogarth House Ltd., 1994, ISBN 0-9641049-0-3
    39. The Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000, ISBN 0-936070-20-X
    40. EPA, Washington, DC 20460, original source: http://www.epa.gov/owm/septic/pubs/homeowner_guide_long.pdf [Copy on file as EPA_Septic_System_homeowner_guide.pdf ]
    41. NSFC, Septic Tank Inspection and Troubleshooting,
    42. Lake, Andrew, Septic Tank Inspection, NSFC, 800-624-8301, web search 5/17/12, original source: http://www.nesc.wvu.edu/pdf/ww/septic/inspection_sfq_w04.pdf [Copy on file as NSFC_Septic_Tank_Inspection.pdf]
    43. Vogel, Michael P., "Septic Tank Inspection and Troubleshooting", Montana State University Extension Service, MT 199403 HR, rev 2005, web search 5/17/12, original source: http://msuextension.org/publications/HomeHealthandFamily/MT199403HR.pdf [Copy on file as MSU_Septic_Tank_Inspection.pdf]
    44. Septic System Inspections, Massachusetts Department of Environmental Protection, Mass DEP, One Winter St., Boston MA 02108, 617-292-5500, original source: http://www.mass.gov/dep/water/wastewater/inspects.htm,
    45. Supplement Existing Septic System Inspection Report, 1 May 2001, Connecticut State Department of Public Health, (860) 509-7296.original source: http://www.ct.gov/dph/lib/dph/environmental_health/environmental_engineering/pdf/supplement.pdf [Copy on file as Septic_Report_CT.pdf ]
    "International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
  • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • Manual of Septic Tank Practice, US Public Health Service's 1959
  • US EPA Onsite Wastewater Treatment Systems Manual [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers. U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf
  • Septic Tank Capacity vs Usage in Daily Gallons of Wastewater Flow, calculating required septic tank size, calculating septic tank volume from size measurements
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf.
  • How Big Should the Leach Field Be? - table of soil percolation rate vs. field size
  • Septic System Drainfield Absorption System Biomat Formation - what leads to drain field clogging and expensive drainfield repairs
  • Septic Tank Pumping Guide: When, Why, How to pump the septic tank
  • Table of Required Septic & Well Clearances: Distances Between Septic System & Wells, Streams, Trees, etc.
  • Ten Steps to Keeping a Septic System Working, suggestions from the U.S. EPA, edits and additions by DJF
  • What is a Septic System An Engineer's View & Septic System FAQ's
  • Pennsylvania State Fact Sheets relating to domestic wastewater treatment systems include:
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-161, Septic System Failure: Diagnosis and Treatment
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-162, The Soil Media and the Percolation Test
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-l64, Mound Systems for Wastewater Treatment
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-165, Septic Tank-Soil Absorption Systems
  • Document Sources used for this web page include but are not limited to: Agricultural Fact Sheet #SW-161 "Septic Tank Pumping," by Paul D. Robillard and Kelli S. Martin. Penn State College of Agriculture - Cooperative Extension, edited and annotated by Dan Friedman (Thanks: to Bob Mackey for proofreading the original source material.)
  • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006). Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text I recommend for professionals--DF.
  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; Quoting from Amazon's description: For the homebuilder, one mistake in estimating or installing wells and septic systems can cost thousands of dollars. This comprehensive guide filled with case studies can prevent that. Master plumber R. Dodge Woodson packs this reader-friendly guide with guidance and information, including details on new techniques and materials that can economize and expedite jobs and advice on how to avoid mistakes in both estimating and construction. Chapters cover virtually every aspect of wells and septic systems, including on-site evaluations; site limitations; bidding; soil studies, septic designs, and code-related issues; drilled and dug wells, gravel and pipe, chamber-type, and gravity septic systems; pump stations; common problems with well installation; and remedies for poor septic situations. Woodson also discusses ways to increase profits by avoiding cost overruns.
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; Quoting an Amazon reviewer's comment, with which we agree--DF:This book is informative as far as it goes and might be most useful for someone with an older system. But it was written in the early 1980s. A lot has changed since then. In particular, the book doesn't cover any of the newer systems that are used more and more nowadays in some parts of the country -- sand mounds, aeration systems, lagoons, etc.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Home Reference Book - Carson DunlopThe Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 25th Ed., 2012, is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. Field inspection worksheets are included at the back of the volume. Special Offer: For a 10% discount on any number of copies of the Home Reference Book purchased as a single order. Enter INSPECTAHRB in the order payment page "Promo/Redemption" space. InspectAPedia.com editor Daniel Friedman is a contributing author.

    Or choose the The Home Reference eBook for PCs, Macs, Kindle, iPad, iPhone, or Android Smart Phones. Special Offer: For a 5% discount on any number of copies of the Home Reference eBook purchased as a single order. Enter INSPECTAEHRB in the order payment page "Promo/Redemption" space.
  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Onsite Wastewater Disposal, R. J. Perkins; Quoting from Amazon: This practical book, co-published with the National Environmental Health Association, describes the step-by-step procedures needed to avoid common pitfalls in septic system technology. Valuable in matching the septic system to the site-specific conditions, this useful book will help you install a reliable system in both suitable and difficult environments. Septic tank installers, planners, state and local regulators, civil and sanitary engineers, consulting engineers, architects, homeowners, academics, and land developers will find this publication valuable.
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around, suffering a bit from small fonts and a weak index. (DF volunteers to serve as indexer if Burks/Minnis re-publish this very useful volume.)While it contains some material more technical than needed by homeowners, Burks/Minnis book on onsite wastewater treatment systems a very useful reference for both property owners and septic system designers. We refer to it often. While Minnis says the best place to buy this book is at Amazon (our link at left), you can also see this book at Minnis' website at http://web page .pace.edu/MMinnisbook
  • Soil Percolation Tests soil perc testing guide and instructions
  • Percolation Testing Manual, CNMI Division of Environmental Quality, PO Box 501304, Saipan, MP 96950
  • Planting Over Septic System Component", Daniel Friedman (author/editor, InspectAPedia.com), The Innovator, Winter/Spring 2008, BCOSSA, British Columbia OnSite Sewage Association, 201-3542 Blansard St., Victoria BC V8X 1W3 Canada
  • Save the Septic System - Do Not Flush These Items Down the Toilet, Daniel Friedman, InspectAPedia.com - PDF document, printable
  • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance. Both new and used (low priced copies are available, and we think the authors are working on an updated edition--DF. Quoting from one of several Amazon reviews: The basics of septic systems, from underground systems and failures to what the owner can do to promote and maintain a healthy system, is revealed in an excellent guide essential for any who reside on a septic system. Rural residents receive a primer on not only the basics; but how to conduct period inspections and what to do when things go wrong. History also figures into the fine coverage.
  • Test Pit Preparation for Onsite Sewage Evaluations, State of Oregon Department of Environmental Quality, Portland OR, 800 452-4011. PDF document. We recommend this excellent document that offers detail about soil perc tests, deep hole tests, safety, and septic design. Readers should also see Soil Percolation Tests and for testing an existing septic system, also see Dye Tests
  • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM; This septic system classic whose title helps avoid intimidating readers new to septic systems, is available new or used at very low prices. It's more entertainment than a serious "how to" book on septic systems design, maintenance, or repair. Not recommended -- DF.
  • Water Wells and Septic Systems Handbook, R. Dodge Woodson. This book is in the upper price range, but is worth the cost for serious septic installers and designers. Quoting Amazon: Each year, thousands upon thousands of Americans install water wells and septic systems on their properties. But with a maze of codes governing their use along with a host of design requirements that ensure their functionality where can someone turn for comprehensive, one-stop guidance? Enter the Water Wells and Septic Systems Handbook from McGraw-Hill.
    Written in language any property owner can understand yet detailed enough for professionals and technical students this easy-to-use volume delivers the latest techniques and code requirements for designing, building, rehabilitating, and maintaining private water wells and septic systems. Bolstered by a wealth of informative charts, tables, and illustrations, this book delivers:
    * Current construction, maintenance, and repair methods
    * New International Private Sewage Disposal Code
    * Up-to-date standards from the American Water Works Association
  • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992. We have found this text very useful for conventional well and septic systems design and maintenance --DF. Quoting an Amazon description:Here's all the information you need to build a well or septic system yourself - and save a lot of time, money, and frustration. S. Blackwell Duncan has thoroughly revised and updated this second edition of Wells and Septic Systems to conform to current codes and requirements. He also has expanded this national bestseller to include new material on well and septic installation, water storage and distribution, water treatment, ecological considerations, and septic systems for problem building sites.