Photograph of backfilling the sewer line trenchSewer Line Replacement Procedure - final backfill

This article describes the final backfill stage when a sewer pipe or "drain line" is replaced.

The line which was replaced in this photo-illustrated case runs from the building exterior to a septic tank located downhill from the home.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers, products, or services discussed at this website.

Guide to Details of Final backfill of the sewer line trench

Photograph of backfilling the sewer line trench Photograph of backfilling the sewer line trench

We present an actual case study, illustrated with photos of each step in the diagnosis and replacement of a blocked sewer line. Technical reviewers are welcome and are listed at "References."

This is a chapter of SEPTIC SYSTEM INSPECTION & MAINTENANCE COURSE an online book on septic systems. Also see CLOGGED DRAIN DIAGNOSIS & REPAIR diagnosing septic backups and septic system failures versus clogged drains. Citation of this article by reference to this website and brief quotation for the sole purpose of review are permitted. Use of this information at other websites, in books or pamphlets for sale is reserved to the author.

After the drain pipe was fully bedded on and under sand, the excavator proceeded to backfill the remainder of the trench by pushing the excavated soil back in place. A skilled excavator can leave the site "rough graded" into a pretty smooth surface.

In this case a little work with an iron rake and some grass seed and the yard surface was back in acceptable condition. We bought a fast-growing fall-seeding grass seed so that grass would grow quickly so as to avoid erosion on the sloped rear yard, and we used some mulch to help hold the new seed in place until grass had sprouted.

Photograph of backfilling and burying site debris Photograph of backfilling and burying site debris

The excavator took advantage of the backfill time to crush and bury piping scraps and debris from the excavated old sewer line. However we collected some of the larger debris, rubber and metal scraps, or other suspect items that had turned up during excavating (including a 1920's vintage automobile tire) to be hauled to a proper disposal site instead of permitting them to simply be buried on this residential property.

Final Site Grading after Sewer Line Replacement

The final grading over a sewer lineor any other septic piping system (such as drainfield trenches) should be left slightly mounded to accomodate the natural settlement of disturbed soils without leaving a trench or depression in the yard surface.

Final Site Cleanup after Sewer Line Replacement

We picked out plastic and other large debris items that the client did not want to discover later in the property's soil. Some of these materials, such as broken sections of abandoned used sewer piping may involve sharp edges or bacteriological hazards and should be disposed-of appropriately.


...

Continue reading  at DOCUMENT BURIED COMPONENT LOCATION or select a topic from the closely-related articles below, or see the complete ARTICLE INDEX.

Or see these

Recommended Articles

Suggested citation for this web page

FINAL BACKFILL SEWER LINE TRENCH at InspectApedia.com - online encyclopedia of building & environmental inspection, testing, diagnosis, repair, & problem prevention advice.


Or see this

INDEX to RELATED ARTICLES: ARTICLE INDEX to DRAIN SEPTIC SEWER PIPES

Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia

Ask a Question or Search InspectApedia

Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly.

Search the InspectApedia website

Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. Apologies for the delay.

Only one image can be added per comment but you can post as many comments, and therefore images, as you like.
You will not receive a notification
when a response to your question has been posted.
Please bookmark this page to make it easy for you to check back for our response.
Our Comment Box is provided by Countable Web Productions countable.ca

Comment Form is loading comments...

Citations & References

In addition to any citations in the article above, a full list is available on request.



ADVERTISEMENT