InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile Phone/PDA website viewMobile View
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR

ADDITIVES / TREATMENTS for SEPTIC SYSTEMS
AEROBIC SEPTIC SYSTEMS
ALTERNATING BED SEPTIC SYSTEMS

BACKUP PREVENTION, SEWER LINE
BIOLOGICAL POLLUTANTS
BIOLOGICAL POLLUTANTS in the HOME - EPA
BOOKS, RECOMMENDED SEPTIC
BOOKSTORE, SEPTIC SYSTEMS

CESSPOOLS
CESSPOOL SAFETY WARNINGS
CHECK VALVES
CHEMICALS & TREATMENTS for SEPTICS
CHLORINE IN DRINKING WATER
CISTERNS
CLOGGED DRAIN DIAGNOSIS & REPAIR

D BOX TROUBLESHOOTING
DEFINITIONS OF SEPTIC SYSTEM TERMS
DIFFICULT SEPTIC SITES
DISTRIBUTION-BOX INSPECTION, SEPTIC
DRAINFIELD FAILURE DIAGNOSIS
DRIVING or PARKING OVER SEPTIC COMPONENTS?
DRYWELL DESIGN & USES

FILTERS SEPTIC & GREYWATER
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODED SEPTIC SYSTEMS, REPAIR

GARBAGE DISPOSAL vs SEPTICS
GRAVELLESS SEPTIC SYSTEMS
GRAVITY/SIPHON DOSING SYSTEMS
GREYWATER SYSTEMS

HOME BUYERS GUIDE to SEPTIC SYSTEMS
HOME SELLERS GUIDE TO SEPTIC INSPECT

LAGOON SEPTIC SYSTEMS
LEACHFIELD FAILURE DIAGNOSIS

MEDIA FILTER SEPTIC SYSTEMS
MOUND SEPTIC SYSTEMS

NOISE / SOUND DIAGNOSIS & CURE

ODORS & SMELLS DIAGNOSIS & CURE
ODOR DIAGNOSIS CHECKLIST
ODORLESS CHEMICALS / GASES: CHECK FOR?
ODORS, PLUMBING SYSTEM
ODORS, SEPTIC or SEWER
ODORS, SULPHUR SMELL SOURCES

OUTHOUSES & LATRINES

PLANTS & TREES OVER SEPTIC SYSTEMS
PRESSURE DOSING SEPTIC SYSTEMS

RAISED BED SEPTIC SYSTEMS

SAND BED SEPTIC SYSTEMS
SEEPAGE PITS

SEPTIC & CESSPOOL SAFETY
SEPTIC AUTHORITIES

SEPTIC BACKUP PREVENTION
SEPTIC BACKUP REPAIR
SEPTIC BOOK, ONLINE
SEPTIC BOOKSTORE
SEPTIC BIOMATS

SEPTIC CARE INSTRUCTIONS
SEPTIC CLEARANCE DISTANCES
SEPTIC CODES & REFERENCES
SEPTIC CONSULTANTS

SEPTIC D-BOX INSPECTION

SEPTIC DRAINFIELD FAILURE DIAGNOSIS
SEPTIC DRAINFIELD INSPECTION & TEST
SEPTIC DRAINFIELD LIFE
SEPTIC DRAINFIELD LOCATION
SEPTIC DRAINFIELD RESTORERS?
SEPTIC DRAWINGS

SEPTIC DYE TEST PROCEDURE

SEPTIC FAILURE LAWSUIT
SEPTIC FAILURE SIGNS
SEPTIC FIELD INSPECTION
SEPTIC FILTERS
SEPTIC FLOOD RESPONSE

SEPTIC INSPECTION BOOK
SEPTIC INSPECTION & TEST GUIDE
SEPTIC LIFE EXPECTANCY
SEPTIC LIFE MAXIMIZING STEPS

SEPTIC METHANE GAS
SEPTIC ODORS

SEPTIC PUMPS
SEPTIC PUMPING REPAIR

SEPTIC REFERENCES

SEPTIC & CESSPOOL SAFETY
SEPTIC SUPPLIES & PARTS
SEPTIC SYSTEM DEFINITIONS

SEPTIC SYSTEM DESIGN ALTERNATIVES
SEPTIC SYSTEM DESIGN BASICS
SEPTIC SYSTEM DESIGN MANUAL - Online

SEPTIC SYSTEMS, HOME BUYERS GUIDE to

SEPTIC SYSTEM INSPECTION & TEST GUIDE
SEPTIC SYSTEMS INSPECTION COURSE
SEPTIC INSPECTION TYPES & LEVELS

SEPTIC SYSTEM ODORS
SEPTIC SYSTEM PUMPS
SEPTIC SYSTEMS ONLINE BOOK
SEPTIC SYSTEM SAFETY WARNINGS
SEPTIC SYSTEM TYPES, MASTER LIST

SEPTIC TANKS
SEPTIC TANK BAFFLES
SEPTIC TANK COVERS
SEPTIC TANK, HOW TO FIND
  SEPTIC SEARCH SAFETY
  WHO KNOWS SEPTIC LOCATION?
  FIND MAIN WASTE LINE EXIT
  DISTANCE TO SEPTIC TANK
  POSSIBLE SEPTIC TANK LOCATIONS
  VISUAL CLUES LOCATE the SEPTIC TANK
  WHERE TO LOOK for the SEPTIC TANK
  SEPTIC TANK DEPTH
  SEPTIC TANK LOCATING EQUIPMENT
  SEPTIC TANK LOCATION SKETCH
SEPTIC TANK INSPECTION PROCEDURE
  CLEANING SEPTIC TANKS
  MEASURE SCUM & SLUDGE
  SEPTIC TANK INSPECTION CHECLIST
  STEEL SEPTIC TANKS
  CONCRETE SEPTIC TANKS
  FIBERGLASS / PLASTIC SEPTIC TANKS
  HOME MADE SITE BUILT TANKS
  SEPTIC TANK BAFFLES
  SEPTIC TANK SOLIDS & SCUM
  SEWAGE LEVELS in SEPTIC TANKS
SEPTIC TANK LEAKS
SEPTIC TANK LEVELS of SEWAGE

SEPTIC TANK PUMPING SCHEDULE
SEPTIC TANK PUMPING PROCEDURE
SEPTIC TANK SAFETY
SEPTIC TANK SIZE
SEPTIC TANK TEES
SEPTIC TESTS: DYE & LOADING TESTS
SEPTIC TREATMENTS & CHEMICALS
  SEPTIC PRODUCTS FOR SALE
  ARE ADDITIVES USEFUL?
  PUMPING PREVENTS FAILURES
  CANADA PROHIBITS ADDITIVES
  ONTARIO MINISTRY
  US EPA on ADDITIVES
  SEPTIC ADDITIVE TYPES
  SEPTIC DRAINFIELD RESTORERS?

SEWAGE BACKUP TEST & CLEANUP
SEWAGE & SEPTIC CONTAMINANTS
SEWAGE CONTAMINATION in buildings
SEWAGE CONTAMINANTS in FRUIT / VEGETABLES
SEWAGE EJECTOR / GRINDER PUMPS
SEWAGE LEVELS in SEPTIC TANKS
SEWAGE NITROGEN CONTAMINANTS
SEWAGE PATHOGENS in SEPTIC SLUDGE
SEWER BACKUP PREVENTION
SEWER GAS ODORS
SEWER LINE REPLACEMENT

SINKHOLES, WARNING SIGNS
SMELL PATCH TEST to Track Down Odors
SOAKAWAY BED FAILURE DIAGNOSIS
SULPHUR & SEWER GAS SMELL SOURCES
SUMP PUMPS

TOILETS, INSPECT, INSTALL, REPAIR
TOILET ALTERNATIVES
TOILET FLUSHOMETER VALVES
TOILET INSTALLATION PROCEDURE
TOILET OVERFLOW EMERGENCY
TOILET PLUGS, SEWER BACKUP
TOILET REPAIR GUIDE
TOILET TISSUE CHOICES
TOILET TYPES
Toilet Types, Flush Methods
TOILETS, DON'T FLUSH LIST
TRAPS on PLUMBING FIXTURES
TREATMENTS & CHEMICALS, SEPTIC

VIDEO GUIDES: Septic Videos
WASHING MACHINES

WASTEWATER TREATMENT BASICS

WATER, WELLS, WATER TANKS: TESTING GUIDE
WATER PURIFIERS

WATER QUALITY TESTS, CONTAMINANTS, TREATMENT
WATER QUANTITY IMPROVEMENT
WATER QUANTITY USAGE GUIDE

WATER SOFTENERS & CONDITIONERS
WATER SUPPLY & DRAIN PIPING

WATER TESTS, CONTAMINANTS, TREATMENT
WATER TREATMENT EQUIPMENT CHOICES

WELLS CISTERNS & SPRINGS
WELL CLEARANCES

WETLAND SEPTIC SYSTEMS

WINTERIZE A BUILDING

More Information

LARGER IMAGE: a steel septic tank with a rusted cover was located in this walking area. A photo of the steel septic tank cover after the author
stepped through it is shown below.

Septic Tank Condition - How to Inspect Steel Septic Tanks
InspectAPedia®  -         

  • Characteristics of steel septic tanks
  • Septic tank inspection procedure - details
  • Types of Septic Tanks: steel septic tanks, concrete septic tanks, fiberglass septic tanks, home made septic tanks - definitions and characteristics of various types of septic tanks
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

This document describes how to inspect the condition of a septic tank, providing special considerations for inspecting steel septic tanks. Inspecting steel septic tanks is a key component in onsite wastewater disposal systems. The photo shows an area where the author walked just before stepping through a rusted-out steel septic tank cover (shown below).

This is a chapter of Septic Systems Inspection, Testing our online book about septic system inspection procedures, defects in onsite waste disposal systems, septic tank problems, septic drainfield problems, checklists of system components and things to ask. Also see The Septic Information Website our main page of articles and information about septic systems and onsite wastewater disposal systems inspection, testing, diagnosis, maintenance, and repair.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

STEEL SEPTIC TANKS - Life Expectancy, What Breaks, What to Look For

Photo of a collapsing steel septic tank location

Steel septic tanks typically last 20-25 years, then rust, and collapse.

Before this time steel baffles may rust off (damaging the drain field with sludge), the tank top may become rusty and unsafe, or the tank bottom may have rusted through. You can see the steel septic tank baffle in the lower left of this photo - notice that the top edges of the baffle have rusted away?

In the photo shown here the steel septic tank cover had rusted through and was covered with brush and about two inches of soil.

Guide to Steel Septic Tank Maintenance and Repair

Photo of a steel septic tank cover near a home in the U.S.

Keep surface and roof runoff away from steel septic tanks or any other septic tanks and also from other septic system components like D-boxes and drainfields. Flooding the system with uninvited water risks shortening the drainfield life and leads to septic system failure.

In the photo at left the steel septic tank is not only located too close to the house (typical for the era of its installation in the 1960's), but also it is near a roof drainage downspout. The owner has wisely added an extension to redirect downspout spillage away from this tank.

Special Hazard Warning for Steel Septic Tank Covers

Rusting steel tank covers can cause death! Rusted covers can collapse. We have reports of children and adults who have died from this hazard, as recently as December 1997. In 2000 the author consulted in a fatality involving an adult falling into a cesspool.

At a building inspection the author, even though walking carefully, stepped through a hidden, rusted-through steel septic tank cover (shown in the photo included here).

Falling into a septic tank, drywell, or cesspool is quickly fatal, either from being buried by falling soils and debris, or by asphyxiation. Septic gases are highly toxic and can kill in just minutes of exposure. Even leaning over an empty (just pumped) tank has led to collapse and fatality of a septic pumper.

Steel septic tank baffle problems: on a steel septic tank the inlet and outlet baffles often rust out and fall off before the owner realizes that the tank needs repair or replacement. This damage permits solids to enter the soil absorption system. In the photo shown above on this page the steel septic tank baffle has rusted away at its top - visible in the lower left of the tank top opening. If a steel septic tank is otherwise in good condition but its baffles have become damaged or have been lost entirely, try inserting a plastic tee in the inlet and outlet waste lines.

Septic tank baffles, or septic tank tees prevent solids from flowing out of the tank into the drainfield, or from blocking waste flow into the tank from the building it serves. But if you see that the steel septic tank baffles have been missing for some unknown time, perhaps a long time, especially at the tank outlet end, you can assume that this condition has reduced the future life of the drainfield by permitting solid waste to flow into that area of the septic system. See Septic Tank Tees for more details about this septic system component.

Steel tank bottoms rust out permitting effluent to leak into soils around the tank, possibly giving a large void in tank at time of testing, thus subverting a loading or dye test. Since steel tank tops can be replaced while leaving the old tank in place, the condition of the top itself is not a reliable indicator of tank condition.

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

SEPTIC TANK GRASS or SNOWMELT
SEPTIC TANK INSPECTION PROCEDURE
  SEPTIC TANK INSPECTION CHECLIST
  STEEL SEPTIC TANKS
  CONCRETE SEPTIC TANKS
  FIBERGLASS / PLASTIC SEPTIC TANKS
  HOME MADE SITE BUILT TANKS
  SEPTIC TANK BAFFLES
  SEPTIC TANK SOLIDS & SCUM

More Reading about septic tanks

  • Septic Tank Location - How to Find the Septic Tank
  • SEPTIC TANK INSPECTION PROCEDURE - how to inspect septic tanks, a checklist, and the proper sequence of inspection during septic tank pumping
  • MEASURE Septic Tank SCUM & SLUDGE - How and Why to Measure Septic Tank Scum and Sludge in the Septic Tank
  • Septic Tank EFFLUENT RETENTION TIME - Septic Effluent Retention time and Effective Septic Tank Volume - Why pump a septic tank before it is "full" of solids and grease?

The Septic Systems Online Book - Where Are We?

  • This Chapter: SEPTIC TANK GRASS or SNOWMELT
    SEPTIC TANK INSPECTION PROCEDURE
    Subchapters you may not have read include:
    MEASURE SCUM & SLUDGE
    CLEANING SEPTIC TANKS
  • Next Chapter: SEPTIC DRAINFIELD FAILURES
  • First Chapter: SEPTIC SYSTEMS ONLINE BOOK

Septic System References & Books

  • "International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
  • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • Manual of Septic Tank Practice, US Public Health Service's 1959
  • The Home Buyer's Guide to Septic Systems
  • Home & Outdoor Living Water Requirements
  • Septic Tank Capacity vs Usage in Daily Gallons of Wastewater Flow, calculating required septic tank size, calculating septic tank volume from size measurements
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf.
  • How Big Should the Leach Field Be? - table of soil percolation rate vs. field size
  • Septic System Drainfield Absorption System Biomat Formation - what leads to drain field clogging and expensive drainfield repairs
  • Septic Tank Pumping Guide: When, Why, How to pump the septic tank
  • Table of Required Septic & Well Clearances: Distances Between Septic System & Wells, Streams, Trees, etc.
  • Ten Steps to Keeping a Septic System Working, suggestions from the U.S. EPA, edits and additions by DJF
  • What is a Septic System An Engineer's View & Septic System FAQ's
  • Pennsylvania State Fact Sheets relating to domestic wastewater treatment systems include:
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-161, Septic System Failure: Diagnosis and Treatment
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-162, The Soil Media and the Percolation Test
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-l64, Mound Systems for Wastewater Treatment
  • Pennsylvania State Wastewater Treatment Fact Sheet SW-165, Septic Tank-Soil Absorption Systems
  • Document Sources used for this web page include but are not limited to: Agricultural Fact Sheet #SW-161 "Septic Tank Pumping," by Paul D. Robillard and Kelli S. Martin. Penn State College of Agriculture - Cooperative Extension, edited and annotated by Dan Friedman (Thanks: to Bob Mackey for proofreading the original source material.)

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Inspecting Septic Systems: Online Book, Inspection, Test, Diagnosis, Repair, & Maintenance: our Online Septic Book: Septic Testing, Loading & Dye Tests, Septic Tank Pumping, Clearances, details of onsite waste disposal system inspection, testing, repair procedures.

  • Advanced Onsite Wastewater Systems Technologies, Anish R. Jantrania, Mark A. Gross. Anish Jantrania, Ph.D., P.E., M.B.A., is a Consulting Engineer, in Mechanicsville VA, 804-550-0389 (2006), Advanced Onsite Wastewater Systems Technologies. Outstanding technical reference especially on alternative septic system design alternatives. Written for designers and engineers, this book is not at all easy going for homeowners but is a text we recommend for professionals--DF.
  • AEROBIC SEPTIC SYSTEMS
  • Builder's Guide to Wells and Septic Systems, Woodson, R. Dodge: $ 24.95; MCGRAW HILL B; TP; Quoting from Amazon's description: For the homebuilder, one mistake in estimating or installing wells and septic systems can cost thousands of dollars. This comprehensive guide filled with case studies can prevent that. Master plumber R. Dodge Woodson packs this reader-friendly guide with guidance and information, including details on new techniques and materials that can economize and expedite jobs and advice on how to avoid mistakes in both estimating and construction. Chapters cover virtually every aspect of wells and septic systems, including on-site evaluations; site limitations; bidding; soil studies, septic designs, and code-related issues; drilled and dug wells, gravel and pipe, chamber-type, and gravity septic systems; pump stations; common problems with well installation; and remedies for poor septic situations. Woodson also discusses ways to increase profits by avoiding cost overruns.
  • Country Plumbing: Living with a Septic System, Hartigan, Gerry: $ 9.95; ALAN C HOOD & TP; Quoting an Amazon reviewer's comment, with which we agree--DF:This book is informative as far as it goes and might be most useful for someone with an older system. But it was written in the early 1980s. A lot has changed since then. In particular, the book doesn't cover any of the newer systems that are used more and more nowadays in some parts of the country -- sand mounds, aeration systems, lagoons, etc.

Design Manuals for Septic Systems

  • US EPA Onsite Wastewater Treatment Systems Manua [online copy, free] Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm Onsite wastewater treatment and disposal systems, Richard J Otis, published by the US EPA. Although it's more than 20 years old, this book remains a useful reference for septic system designers. U.S. Environmental Protection Agency, Office of Water Program Operations; Office of Research and Development, Municipal Environmental Research Laboratory; (1980)
  • Eco John® Innovative Toilet Solutions, Global Inventive Industries, Fountain Valley CA, PDF, product brochure
  • "International Private Sewage Disposal Code," 1995, BOCA-708-799-2300, ICBO-310-699-0541, SBCCI 205-591-1853, available from those code associations.
  • "Manual of Policy, Procedures, and Guidelines for Onsite Sewage Systems," Ontario Reg. 374/81, Part VII of the Environmental Protection Act (Canada), ISBN 0-7743-7303-2, Ministry of the Environment,135 St. Clair Ave. West, Toronto Ontario M4V 1P5 Canada $24. CDN.
  • Manual of Septic Tank Practice, US Public Health Service's 1959.

Onsite Wastewater Disposal Books

  • Onsite Wastewater Disposal, R. J. Perkins; Quoting from Amazon: This practical book, co-published with the National Environmental Health Association, describes the step-by-step procedures needed to avoid common pitfalls in septic system technology. Valuable in matching the septic system to the site-specific conditions, this useful book will help you install a reliable system in both suitable and difficult environments. Septic tank installers, planners, state and local regulators, civil and sanitary engineers, consulting engineers, architects, homeowners, academics, and land developers will find this publication valuable.
  • Onsite Wastewater Treatment Systems, Bennette D. Burks, Mary Margaret Minnis, Hogarth House 1994 - one of the best septic system books around, suffering a bit from small fonts and a weak index. (DF volunteers to serve as indexer if Burks/Minnis re-publish this very useful volume.)

    While it contains some material more technical than needed by homeowners, Burks/Minnis book on onsite wastewater treatment systems a very useful reference for both property owners and septic system designers. We refer to it often. While Minnis says the best place to buy this book is at Amazon (our link at left), you can also see this book at Minnis' website at http://web page .pace.edu/MMinnisbook
  • Septic Tank/Soil-Absorption Systems: How to Operate & Maintain [ copy on file as /septic/Septic_Operation_USDA.pdf ] - , Equipment Tips, U.S. Department of Agriculture, 8271 1302, 7100 Engineering, 2300 Recreation, September 1982, web search 08/28/2010, original source: http://www.fs.fed.us/t-d/pubs/pdfimage/82711302.pdf
  • Soil Percolation Tests soil perc testing guide and instructions
  • Percolation Testing Manual, CNMI Division of Environmental Quality, PO Box 501304, Saipan, MP 96950
  • Planting Over Septic System Component", Daniel Friedman (author/editor, InspectAPedia.com), The Innovator, Winter/Spring 2008, BCOSSA, British Columbia OnSite Sewage Association, 201-3542 Blansard St., Victoria BC V8X 1W3 Canada
  • Save the Septic System - Do Not Flush These Items Down the Toilet, Daniel Friedman, InspectAPedia.com - PDF document, printable
  • SEPTIC STANDARDS
  • SEPTIC MAGAZINES
  • Septic System Owner's Manual, Lloyd Kahn, Blair Allen, Julie Jones, Shelter Publications, 2000 $14.95 U.S. - easy to understand, well illustrated, one of the best practical references around on septic design basics including some advanced systems; a little short on safety and maintenance. Both new and used (low priced copies are available, and we think the authors are working on an updated edition--DF. Quoting from one of several Amazon reviews: The basics of septic systems, from underground systems and failures to what the owner can do to promote and maintain a healthy system, is revealed in an excellent guide essential for any who reside on a septic system. Rural residents receive a primer on not only the basics; but how to conduct period inspections and what to do when things go wrong. History also figures into the fine coverage.
  • Test Pit Preparation for Onsite Sewage Evaluations, State of Oregon Department of Environmental Quality, Portland OR, 800 452-4011. PDF document. We recommend this excellent document that offers detail about soil perc tests, deep hole tests, safety, and septic design. Readers should also see Soil Percolation Tests and for testing an existing septic system, also see Dye Tests
  • Grass is Always Greener Over the Septic Tank, Bombeck, Erma: $ 5.99; FAWCETT; MM; This septic system classic whose title helps avoid intimidating readers new to septic systems, is available new or used at very low prices. It's more entertainment than a serious "how to" book on septic systems design, maintenance, or repair. Not recommended -- DF.
  • US EPA Onsite Wastewater Treatment Systems Manual Top Reference: US EPA's Design Manual for Onsite Wastewater Treatment and Disposal, 1980, available from the US EPA, the US GPO Superintendent of Documents (Pueblo CO), and from the National Small Flows Clearinghouse. Original source http://www.epa.gov/ORD/NRMRL/Pubs/625R00008/625R00008.htm
  • Water Wells and Septic Systems Handbook, R. Dodge Woodson. This book is in the upper price range, but is worth the cost for serious septic installers and designers. Quoting Amazon: Each year, thousands upon thousands of Americans install water wells and septic systems on their properties. But with a maze of codes governing their use along with a host of design requirements that ensure their functionality where can someone turn for comprehensive, one-stop guidance? Enter the Water Wells and Septic Systems Handbook from McGraw-Hill.
    Written in language any property owner can understand yet detailed enough for professionals and technical students this easy-to-use volume delivers the latest techniques and code requirements for designing, building, rehabilitating, and maintaining private water wells and septic systems. Bolstered by a wealth of informative charts, tables, and illustrations, this book delivers:
    * Current construction, maintenance, and repair methods
    * New International Private Sewage Disposal Code
    * Up-to-date standards from the American Water Works Association
  • Wells and Septic Systems, Alth, Max and Charlet, Rev. by S. Blackwell Duncan, $ 18.95; Tab Books 1992. We have found this text very useful for conventional well and septic systems design and maintenance --DF. Quoting an Amazon description:Here's all the information you need to build a well or septic system yourself - and save a lot of time, money, and frustration. S. Blackwell Duncan has thoroughly revised and updated this second edition of Wells and Septic Systems to conform to current codes and requirements. He also has expanded this national bestseller to include new material on well and septic installation, water storage and distribution, water treatment, ecological considerations, and septic systems for problem building sites.
  • The NSFC Products List has an excellent list of design manuals/modules available from their website or by telephone 800-624-8301
  • Submissions welcome. send us a suggested document link or request an exchange of website links
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com