InspectAPedia.com InspectAPedia®
Google
InspectAPedia
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile viewMobile View
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

AIR CLEANER PURIFIER TYPES
AIR FILTER EFFECTIVENESS
AIR FILTERS, FIBERGLASS PARTICLES
AIR FILTERS for HVAC SYSTEMS
AIR FILTERS, OPTIMUM INDOOR
AIR FILTERS, SOURCES FOR
AIR FILTERING STRATEGIES
AIR FILTERING CONTINUOUS FAN OPERATION
AIR HANDLER / BLOWER UNITS
AIR LEAK DETECTION TOOLS
AIR POLLUTANTS, COMMON INDOOR
Air Quality Improvement Strategies
AIR LEAK SEALING PROCEDURE
AIR SEALING STRATEGIES
AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY
AIRBORNE MOLD SPORE COUNT ACCURACY
ALLERGEN TESTS for buildings
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
ANIMAL ALLERGENS / PET DANDER
ANIMAL ENTRY POINTS in buildings

ASBESTOS CLEANUP COMPANIES
ASBESTOS ROOFING / SIDING DUST
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
  ASBESTOS AIR DUCTS
  Asbestos Air Duct Vibration Dampers
  ASBESTOS in CARPETING, PADDING
  ASBESTOS CEILING TILES, Asbestos-Containing
  ASBESTOS DUCTS, HVAC
  ASBESTOS DUCT INSULATION, Asbestos Paper
  ASBESTOS DUCTS, Transite Pipe
  ASBESTOS FIREPROOFING SPRAY-On Coatings
  ASBESTOS FLOOR TILE IDENTIFICATION
  ASBESTOS FLOOR TILE LAB PROCEDURES
  ASBESTOS FLOOR TILE PHOTO ID GUIDE
  ASBESTOS FLOORING HAZARD REDUCTION
  ASBESTOS FLOORING REMOVAL GUIDE
  Asbestos Foamed-Over
  ASBESTOS INSULATION
  ASBESTOS PAPER DUCT INSULATION
  ASBESTOS PIPE INSULATION
  ASBESTOS ROOFING, CEMENT & FIBER CEMENT
  ASBESTOS ROOFING / SIDING DUST
  ASBESTOS SIDING CEMENT & FIBER CEMENT
  ASBESTOS in UNUSUAL PLACES
  ASPHALT-ASBESTOS PAINT / SEALANT
  TRANSITE PIPE AIR DUCTS
  TRANSITE PIPE CHIMNEYS / FLUES
  TRANSITE PIPE WATER SUPPLY
  VERMICULITE INSULATION
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS FLOORING REMOVAL GUIDE
ASBESTOS LIST of PRODUCTS
ASBESTOS MATERIAL REGULATIONS
ASBESTOS MATERIAL REGULATIONS Update
ASBESTOS MATERIAL REGULATIONS, OSHA
ASBESTOS PHOTO GUIDE to Materials
ASBESTOS RISK ASSESSMENT
  Asbestos risk: in Good Condition
  Asbestos risk: in Poor Condition
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
ASBESTOS REMOVAL GUIDE, FLOORING
ASBESTOS REMOVAL, Wetting Guidelines
ATTORNEYS and EXPERT WITNESSES

BACKDRAFTING HEATING EQUIPMENT
BIBLIOGAPHY for ENVIRONMENTAL HEALTH, MOLD, IAQ
BIOGAS PRODUCTION & USE
BIOLOGICAL POLLUTANTS

BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC
BLEACHING MOLD, Advice about
BLOWER DOORS & AIR INFILTRATION
BLUE vs YELLOW COMBUSTION FLAMES
Bisphenol-A, BPA
BLEACHING MOLD, Advice about
BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
BUILDING SAFETY HAZARDS GUIDE

CAR MOLD CONTAMINATION
CARBON MONOXIDE - CO
Carbon Nanotube Materials
CARPET MOLD CONTAMINATION
CARPETS & PADDING ODORS IN buildings
Cell phone Radiation Hazards
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHINESE DRYWALL HAZARDS
CHLORINE IN DRINKING WATER
CHLORINE in WATER, HOW TO TEST FOR
CHLORINE IN SEPTIC WASTEWATER
COMBUSTION GASES & PARTICLE HAZARDS
Diethylstilbestrol - DES
DUST ANALYSIS for FIBERGLASS
DUST SAMPLING PROCEDURE

EMERGENCY RESPONSE, IAQ, GAS, MOLD
EMF ELECTROMAGNETIC FIELDS & HUMAN EXPOSURE
EMF Levels of Cancer Risk
EMF MEASUREMENT PROCEDURES
ENERGY SAVINGS in buildings
ENVIRO-SCARE - PUBLIC FEAR CYCLES
EXTERIORS of buildings

FIBERGLASS HAZARDS
FIBERGLASS INSULATION MOLD
FIBERGLASS PARTICLE CONTAMINATION TEST
Fireplaces & Woodstove Contaminants
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOOR TYPES & DEFECTS
ASBESTOS FLOOR TILE IDENTIFICATION
FORMALDEHYDE HAZARDS

GAS EXPOSURE EFFECTS

HEATING OIL EXPOSURE HAZARDS, LIMITS
HUMIDITY CONTROL & TARGETS INDOORS

INDOOR AIR QUALITY IMPROVEMENT GUIDE
INSULATION INSPECTION & IMPROVEMENT
INSULATION IDENTIFICATION GUIDE
INSULATION, ASBESTOS
INSULATION MOLD

LEED Building Designation & IAQ
LIGHTING, EXTERIOR GUIDE
LIGHTING, INTERIOR GUIDE
LIGHTNING PROTECTION
UFFI UREA FORMALDEHYDE FOAM INSULATION
LEAD POISONING HAZARDS GUIDE
LEED Building Designation & IAQ
LP & Natural Gas Safety Hazards
Legionella Legionnaires' Disease

METHANE GAS SOURCES
MILDEW in buildings ?
MOISTURE CONTROL in BUILDINGS

MOLD: A COMPLETE GUIDE TO MOLD
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CONSULTANTS/INSPECTORS
MOLD CULTURE TEST KIT VALIDITY
MOLD DETECTION & INSPECTION GUIDE
MOLD or INDOOR AIR EMERGENCY RESPONSE
MOLD EXPERT, WHEN TO HIRE
MOLD FAQ's
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TESTING METHOD VALIDITY

MVOCs & MOLDY MUSTY ODORS
Museum Artifact Preservation

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE
OIL, HEATING, EXPOSURE HAZARDS, LIMITS
OIL TANKS INSPECT LEAK TEST ABANDON REGS
OXYGEN - O2
OZONE HAZARDS
OZONE for MOLD OR ODORS

PAINTS & COATINGS ODORS IN buildings
PARTICLE SIZES & IAQ
Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
PLASTIC CONTAINERS, TANKS, TYPES
PLASTIC HEATER VENT
PLASTIC ODORS-SCREENS, SIDING
PLUMBING SYSTEM ODORS
PVC - VINYL BUILDING PRODUCTS

RADON HAZARD TESTS & MITIGATION
SAFETY HAZARDS GUIDE
SEPTIC SYSTEM ODORS
SEWER GAS ODORS
SIDING VINYL
SMELL PATCH TEST to Track Down Odors
SOUND CONTROL in buildings
SOLAR ENERGY SYSTEMS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS

SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
SULPHUR & SEWER GAS SMELL SOURCES

THERMAL TRACKING Indicates Heat Loss

Urea Formaldehyde Foam Insulation UFFI
URETHANE FOAM Deterioration, Outgassing

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VAPOR BARRIERS & HOUSEWRAP
VAPOR CONDENSATION & BUILDING SHEATHING
VENTILATION in BUILDINGS
VINYL CHLORIDE HEALTH INFO
VINYL Siding or PLASTIC Window ODORS in buildings
Volatile Organic Compounds VOCs

WATER ODORS, CAUSE CURE
WATER TANK SAFETY
WATER TESTS, CONTAMINANTS, TREATMENT
WATER TEST CHOICES & WATER TEST FEES
WATER TREATMENT EQUIPMENT CHOICES
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
World Trade Center Collapse Dust Photos

More Information

Photograph of  Amateur incomplete cleaning of asbestos on a

Amateur Asbestos, Lead, Mold Cleanup Jobs: Warnings
InspectAPedia®  -      

  • Photographs of amateur, incompetent asbestos cleanup work
  • How to spot asbestos in poor or damaged condition in buildings & what to do about it
  • How to spot evidence of improper asbestos removal efforts
  • Abandoned asbestos pipe insulation or duct materials
  • Photographs of asbestos in building products
  • Questions & answers about the hazards of amateur or incomplete asbestos removal or cleanup projects

Dangerous amateur asbestos removal jobs: this article provides photographs of amateur, incomplete, and incompetent asbestos cleanup jobs to help building owners or home buyers spot asbestos in poor or damaged condition in buildings, including identification of amateur or improper asbestos "abatement" projects that failed to properly remove materials or that left abandoned asbestos materials in place.

InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

INCOMPLETE, AMATEUR REMOVAL - Asbestos on heating pipes - incomplete, amateur removal - highly suspect for contamination

Amateur incomplete cleaning of asbestos on a heating pipe

Readers should see ASBESTOS RISK ASSESSMENT. Also see ASBESTOS FLOORING REMOVAL GUIDE and see Asbestos Roof Power Washing for another example of amateur asbestos removal. Where wetting of asbestos materials is needed during removal or demolition see ASBESTOS REMOVAL, Wetting Guidelines.

Fuzzy scraps of asbestos-suspect material left on a rusty steel heating pipe in a basement indicate that asbestos insulation was removed without cleaning and sealing the surface of the pipe.


Amateur incomplete cleaning of asbestos on a

Here is a close up of asbestos debris left on a heating pipe. The insulation was simply removed without cleaning.

Amateur incomplete cleaning of asbestos on a

This is another heating pipe elbow which was not cleaned of asbestos insulation. Unlike the "corrugated paper" asbestos insulation used on horizontal pipe runs, an asbestos paste was used at pipe elbows and on other irregular shapes.

Photograph of  Amateur incomplete cleaning of asbestos on a Here is a close up of asbestos insulation paste left on a pipe elbow, evidence of amateur workmanship during an asbestos insulation remediation.

The orangish fibrous material under the white covering on the straight pipe runs is fiberglass pipe insulation which has been added.

But the remaining paste on the elbow tells us that the pipes were not cleaned and washed during the remediation.

Someone installed fiberglass heating pipe insulation around the elbow but left the elbow un-cleaned.

 

The building owner had been told that a proper asbestos removal had been performed and that all pipes were re-insulated.

A professional asbestos abatement company with properly-trained workers and competent supervision would have washed these pipes and probably painted them with a sealant.

Finding scraps of asbestos insulation material left on heating pipes (such as in these photos) is a strong indicator that removal was done by an amateur. In such cases I recommend that the building air and settled dust on surfaces be tested for asbestos contamination since removal was by amateurs.

Any air handling equipment (such as a central air conditioning system) should also be checked for asbestos fiber contamination.

When we see evidence of short cuts and amateur workmanship in an asbestos remediation project we're worried that there may have been asbestos contamination of other site or building areas.

So the expense to "correct" this condition, if testing confirms cross-contamination of the site with asbestos fibers, could be greater than the simple cost to clean and re-insulate the piping. Professional cleaning of other building areas could be needed.

Certification & Licensing for Asbestos Abatement, Removal, & Cleanup Companies: Consumer Warning about Environmental Cleanup Contractors

Details are at Asbestos Removal, Certification. Excerpts are below.

Watch out: in 2010 The New York Times reported [paraphrasing from that article] that over a five year period beginning in 2001 hundreds of asbestos-removal training certificates were given to people who had completed no training whatsoever. The U.S. E.P.A. reported [according to the Times] that Albania Deleon, operating Environmental Compliance Training, a certified asbestos-removal training school in Methuen, MA and the largest such asbestos cleanup training school in the state. 65 to 80 percent of those receiving certification as qualified asbestos removal experts had not received the necessary training.

Many "Graduates from Environmental Compliance Training also obtained jobs through a temporary employment agency also owned by Deleon, were sent out to perform dangerous asbestos cleanup jobs, and were paid "under the table". Deleon was convicted in 2008 of criminal charges but fled the U.S.. She was captured in the Dominican Republic in 2008.

Questions & Answers regarding this article

Questions & answers about the hazards of amateur or incomplete asbestos removal or cleanup projects.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share / Recommend this Article        

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
ASBESTOS REMOVAL GUIDE, FLOORING
ASBESTOS REMOVAL, Wetting Guidelines

  • 3/07: thanks to Gary Randolph, Ounce of Prevention Home Inspection, LLC Buffalo, NY, for attentive reading and editing suggestions. Mr. Randolph can be reached in Buffalo, NY, at (716) 636-3865 or email: gary@ouncehome.com
  • 06/07: thanks for photographs of transite asbestos heating ducts, courtesy of Thomas Hauswirth, Managing Member of Beacon Fine Home Inspections, LLC and (in 2007) Vice President, Connecticut Association of Home Inspectors Ph. 860-526-3355 Fax 860-526-2942 beaconinspections@sbcglobal.net
  • Asbestos regulations for Ontario are published under the Occupational Health and Safety Act and are in Ontario Regulation 278/05 Web search 11/4/2010, original source: http://www.e-laws.gov.on.ca/html/regs/english/elaws_regs_050278_e.htm
  • June 1997 - Window Putty - OSHA case cites contractor for asbestos exposure during removal of window putty http://www.osha.gov/pls/oshaweb/owadisp.show_document?p_table=NEWS_RELEASES&p_id=1091
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • Asbestos in Your Home U.S. EPA, Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print, text and images available at InspectAPedia.com).
  • "Handling Asbestos-Containing roofing material - an update", Carl Good, NRCA Associate Executive Director, Professional Roofing, February 1992, p. 38-43
  • EPA Guidance for Controlling Asbestos-Containing Materials in buildings, NIAST, National Institute on Abatement Sciences & Technology, [republishing EPA public documents] 1985 ed., Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • ...

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com