ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

AIR CLEANER PURIFIER TYPES
AIR FILTER EFFECTIVENESS
AIR FILTERS, FIBERGLASS PARTICLES
AIR FILTERS for HVAC SYSTEMS
AIR FILTERS, OPTIMUM INDOOR
AIR FILTERS, SOURCES FOR
AIR FILTERING STRATEGIES
AIR FILTERING CONTINUOUS FAN OPERATION
AIR HANDLER / BLOWER UNITS
AIR LEAK DETECTION TOOLS
AIR POLLUTANTS, COMMON INDOOR
Air Quality Improvement Strategies
AIR LEAK SEALING PROCEDURE
AIR SEALING STRATEGIES
AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY
AIRBORNE MOLD SPORE COUNT ACCURACY
ALLERGEN TESTS for buildings
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
ANIMAL ALLERGENS / PET DANDER
ANIMAL ENTRY POINTS in buildings

ASBESTOS CLEANUP COMPANIES
ASBESTOS ROOFING / SIDING DUST
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
  ASBESTOS AIR DUCTS
  Asbestos Air Duct Vibration Dampers
  ASBESTOS in CARPETING, PADDING
  ASBESTOS CEILING TILES, Asbestos-Containing
  ASBESTOS DUCTS, HVAC
  ASBESTOS DUCT INSULATION, Asbestos Paper
  ASBESTOS DUCTS, Transite Pipe
  ASBESTOS FIREPROOFING SPRAY-On Coatings
  ASBESTOS FLOOR TILE IDENTIFICATION
  ASBESTOS FLOOR TILE LAB PROCEDURES
  ASBESTOS FLOOR TILE PHOTO ID GUIDE
  ASBESTOS FLOORING HAZARD REDUCTION
  ASBESTOS FLOORING REMOVAL GUIDE
  Asbestos Foamed-Over
  ASBESTOS INSULATION
  ASBESTOS PAPER DUCT INSULATION
  ASBESTOS PIPE INSULATION
  ASBESTOS ROOFING, CEMENT & FIBER CEMENT
    Asphalt-asbestos Roofing Materials
    ASBESTOS ROOFING / SIDING DUST
    Cement-asbestos roof shingles
    Corrugated Cement-Asbestos Roofing
    Environmental Issues - Asbestos Roofing/Siding
    Maintenance Tips for Asbestos Cement Shingles
    OSHA Regulations, Asbestos Roofing, Siding
    Power Washing Asbestos Roofing
    Replacements for Asbestos Cement Shingles
    Roof Paint, Asphalt-asbestos sealants
    Warranty & Class Actions, Fiber Cement Shingles
    Wear Signs on Cement Asbestos Shingles
  ASBESTOS SIDING CEMENT & FIBER CEMENT
    Asbestos vs. fiber-cement
    ASBESTOS ROOFING / SIDING DUST
    Maintenance & Repair Asbestos Cement Shingles
    OSHA Regulations, Asbestos Roofing, Siding
    Painting Cement Asbestos Siding
    Remove & Replace Asbestos Cement Shingles
    Re-Sale Issues - Cement Asbestos siding
    Siding over asbestos cement
    Sources of Replacements for Asbestos Cement Shingles
    Tools to Cut Fiber Cement Shingles
    Wear signs on cement asbestos walls
  ASBESTOS in UNUSUAL PLACES
  ASPHALT-ASBESTOS PAINT / SEALANT
  TRANSITE PIPE AIR DUCTS
  TRANSITE PIPE CHIMNEYS / FLUES
  TRANSITE PIPE WATER SUPPLY
  VERMICULITE INSULATION
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS FLOORING REMOVAL GUIDE
ASBESTOS LIST of PRODUCTS
ASBESTOS MATERIAL REGULATIONS
ASBESTOS MATERIAL REGULATIONS Update
ASBESTOS MATERIAL REGULATIONS, OSHA
ASBESTOS PHOTO GUIDE to Materials
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
ASBESTOS REMOVAL GUIDE, FLOORING
ASBESTOS REMOVAL, Wetting Guidelines
ASBESTOS RISK ASSESSMENT
  Asbestos risk: in Good Condition
  Asbestos risk: in Poor Condition
Asbestos Under the Microscope
ATTORNEYS and EXPERT WITNESSES

BACKDRAFTING HEATING EQUIPMENT
BIBLIOGAPHY for ENVIRONMENTAL HEALTH, MOLD, IAQ
BIOGAS PRODUCTION & USE
BIOLOGICAL POLLUTANTS

BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC
BLEACHING MOLD, Advice about
BLOWER DOORS & AIR INFILTRATION
BLUE vs YELLOW COMBUSTION FLAMES
Bisphenol-A, BPA
BLEACHING MOLD, Advice about
BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
BUILDING SAFETY HAZARDS GUIDE

CAR MOLD CONTAMINATION
CARBON MONOXIDE - CO
Carbon Nanotube Materials
CARPET MOLD CONTAMINATION
CARPETS & PADDING ODORS IN buildings
Cell phone Radiation Hazards
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHINESE DRYWALL HAZARDS
CHLORINE IN DRINKING WATER
CHLORINE in WATER, HOW TO TEST FOR
CHLORINE IN SEPTIC WASTEWATER
COMBUSTION GASES & PARTICLE HAZARDS

Diethylstilbestrol - DES
DUST ANALYSIS for FIBERGLASS
DUST SAMPLING PROCEDURE

EMERGENCY RESPONSE, IAQ, GAS, MOLD
EMF ELECTROMAGNETIC FIELDS & HUMAN EXPOSURE
EMF Levels of Cancer Risk
EMF MEASUREMENT PROCEDURES
ENERGY SAVINGS in buildings
ENVIRO-SCARE - PUBLIC FEAR CYCLES
EXTERIORS of buildings

FIBERGLASS HAZARDS
FIBERGLASS INSULATION MOLD
FIBERGLASS PARTICLE CONTAMINATION TEST
Fireplaces & Woodstove Contaminants
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOOR TYPES & DEFECTS
ASBESTOS FLOOR TILE IDENTIFICATION
FORMALDEHYDE HAZARDS

GAS EXPOSURE EFFECTS

HEATING OIL EXPOSURE HAZARDS, LIMITS
HUMIDITY CONTROL & TARGETS INDOORS

INDOOR AIR QUALITY IMPROVEMENT GUIDE
INSULATION INSPECTION & IMPROVEMENT
INSULATION IDENTIFICATION GUIDE
INSULATION, ASBESTOS
INSULATION MOLD

LEED Building Designation & IAQ
LIGHTING, EXTERIOR GUIDE
LIGHTING, INTERIOR GUIDE
LIGHTNING PROTECTION
UFFI UREA FORMALDEHYDE FOAM INSULATION
LEAD POISONING HAZARDS GUIDE
LEED Building Designation & IAQ
LP & Natural Gas Safety Hazards
Legionella Legionnaires' Disease

METHANE GAS SOURCES
MILDEW in buildings ?
MOISTURE CONTROL in BUILDINGS

MOLD: A COMPLETE GUIDE TO MOLD
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CONSULTANTS/INSPECTORS
MOLD CULTURE TEST KIT VALIDITY
MOLD DETECTION & INSPECTION GUIDE
MOLD or INDOOR AIR EMERGENCY RESPONSE
MOLD EXPERT, WHEN TO HIRE
MOLD FAQ's
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TESTING METHOD VALIDITY

MVOCs & MOLDY MUSTY ODORS
Museum Artifact Preservation

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE
OIL, HEATING, EXPOSURE HAZARDS, LIMITS
OIL TANKS INSPECT LEAK TEST ABANDON REGS
OXYGEN - O2
OZONE HAZARDS
OZONE for MOLD OR ODORS

PAINTS & COATINGS ODORS IN buildings
PARTICLE SIZES & IAQ
Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
PLASTIC CONTAINERS, TANKS, TYPES
PLASTIC HEATER VENT
PLASTIC ODORS-SCREENS, SIDING
PLUMBING SYSTEM ODORS
PVC - VINYL BUILDING PRODUCTS

RADON HAZARD TESTS & MITIGATION
SAFETY HAZARDS GUIDE
SEPTIC SYSTEM ODORS
SEWER GAS ODORS
SIDING VINYL
SMELL PATCH TEST to Track Down Odors
SOUND CONTROL in buildings
SOLAR ENERGY SYSTEMS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS

SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
SULPHUR & SEWER GAS SMELL SOURCES

THERMAL TRACKING Indicates Heat Loss

Urea Formaldehyde Foam Insulation UFFI
URETHANE FOAM Deterioration, Outgassing

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VAPOR BARRIERS & HOUSEWRAP
VAPOR CONDENSATION & BUILDING SHEATHING
VENTILATION in BUILDINGS
VINYL CHLORIDE HEALTH INFO
VINYL Siding or PLASTIC Window ODORS in buildings
Volatile Organic Compounds VOCs

WATER ODORS, CAUSE CURE
WATER TANK SAFETY
WATER TESTS, CONTAMINANTS, TREATMENT
WATER TEST CHOICES & WATER TEST FEES
WATER TREATMENT EQUIPMENT CHOICES
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
World Trade Center Collapse Dust Photos

More Information

Asbestos roof debris runoff after power washing (C) Daniel Friedman

Asbestos Cement Roof Power Washing Troubles & Warnings
InspectAPedia®  -      

  • Power washing an asbestos cement roof raises environmental contamination worries
  • Certification & Training for Asbestos Abatement, Cleanup, or Removal Workers & Companies
  • Warnings about un-trained asbestos cleanup workers
  • Lack of training or job supervision result in improper asbestos, lead, mold and similar contamination removal efforts
  • Questions & answers about assessing the risk of damaged cement asbestos roofing and site contamination by asbestos fiber runoff after powe washing a roof

Asbestos cement roof damaged by washing: this article warns about un-supervised or un-trained environmental cleanup companies or work crews handling asbestos, lead, mold, and similar indoor contaminants, including identification of amateur or improper asbestos "abatement" projects that failed to properly remove materials or that left abandoned asbestos materials in place.

InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Asbestos Cement Roof Washing Troubles - "... they power-washed my asbestos cement roof ..."

Asbestos roof debris runoff after power washing (C) Daniel Friedman Asbestos roof debris runoff after power washing (C) Daniel Friedman

Question: Is power-washed asbestos-cement roof runoff an environmental hazard?

I live in Brantford Ontario and a building in my neighbourhood has was I think is a corrugated asbestos roof. Last weekend some workmen power washed it. The run off, when dried, looked like grey powder and lifted from the pavement in "sheets" almost like parchment paper. I've attached a couple of photos. Does this present any danger or give cause for health concerns? - D.F., Brantford ONT

Reply: Asbestos hazards are probably present, asbestos regulation violations may have occurred, and further steps are needed

OPINION:

Corrugated cement asbestos roofingMost likely the debris that was washed off of the roof contains road and other environmental dust that had settled on the roof surface over time, and possibly algae, mold, or lichens that were staining the surface (as in our file photo of corrugated asbestos roofing - left) leading to the desire to wash the roof in the first place. But because power washing is a strong approach to cleaning a surface it is likely to also have dislodged asbestos and cement particles from the asbestos-cement corrugated roof itself.

While wetting the material, something that would naturally occur during the power-washing of the cement-asbestos roof surface, would be expected to reduce the airborne level of asbestos during the actual washing process, although when properly peformed, wetting to control asbestos particle release includes the addition of a wetting agent to the spray before it is applied.

Power-washing a cement asbestos roof would leave substantial materials on the ground after the clening procedure. As the on-ground material dries asbestos fiber and particle risks are likely to be present.

So it would be no surprise if the debris on the ground around the building in your photos contains a high level of asbestos fibers and particles. The material therefore may form an airborne asbestos hazard in the neighborhood, or as it washes into local storm drains, it may constitute an illegal and improper disposal of asbestos dust and debris.

If the added cost to properly clean up this mess is going to be high (which we would guess is the case), it would be appropriate and inexpensive to collect a debris sample for testing by a local, certified asbestos testing lab to confirm that the contents are indeed contaminated at a level requiring professional cleaning.

In addition, power-washing the roof surface risks increasing the friable nature of the material that remains on the building, as the cementious binding has been removed from the uppermost roof surface, first by normal weathering and second, and much more aggressively, by the power washing process.

The building owners should address these questions immediately in order to reduce the spread and thus possible costs of a proper asbestos dust cleanup.

Asbestos regulations for Ontario are published under the Occupational Health and Safety Act and are in Ontario Regulation 278/05 and provide a clearly-written and comprehensive guide to cleaning up and disposing of asbestos containing materials in or on buildings. Discussing [Type 1] asbestos operations that regulation states:

1. Before beginning work, visible dust shall be removed with a damp cloth or a vacuum equipped with a HEPA filter from any surface in the work area, including the thing to be worked on, if the dust on that surface is likely to be disturbed.

2. The spread of dust from the work area shall be controlled by measures appropriate to the work to be done including the use of drop sheets of polyethylene or other suitable material that is impervious to asbestos.

3. In the case of an operation mentioned in paragraph 4 of subsection 12 (2), the material shall be wetted before and kept wet during the work to control the spread of dust or fibres, unless wetting would create a hazard or cause damage.

4. A wetting agent shall be added to water that is to be used to control the spread of dust and fibres.

5. Frequently and at regular intervals during the doing of the work and immediately on completion of the work,

i. dust and waste shall be cleaned up and removed using a vacuum equipped with a HEPA filter, or by damp mopping or wet sweeping, and placed in a container as described in paragraph 5 of section 15, and

ii. drop sheets shall be wetted and placed in a container as described in paragraph 5 of section 15, as soon as practicable after subparagraph i has been complied with.

6. Drop sheets shall not be reused.

7. After the work is completed, polyethylene sheeting and similar materials used for barriers and enclosures shall not be reused, but shall be wetted and placed in a container as described in paragraph 5 of section 15 as soon as practicable after paragraph 5 of this section has been complied with.

Watch out: in 2010 The New York Times reported [paraphrasing from that article] that over a five year period beginning in 2001 hundreds of asbestos-removal training certificates were given to people who had completed no training whatsoever. The U.S. E.P.A. reported [according to the Times] that Albania Deleon, operating Environmental Compliance Training, a certified asbestos-removal training school in Methuen, MA and the largest such asbestos cleanup training school in the state. 65 to 80 percent of those receiving certification as qualified asbestos removal experts had not received the necessary training.

Many "Graduates from Environmental Compliance Training also obtained jobs through a temporary employment agency also owned by Deleon, were sent out to perform dangerous asbestos cleanup jobs, and were paid "under the table". Deleon was convicted in 2008 of criminal charges but fled the U.S.. She was captured in the Dominican Republic in 2008.

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

ASBESTOS CEMENT & FIBER CEMENT ROOFING
ASBESTOS MATERIAL REGULATIONS
ASBESTOS REGULATION Update
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS ROOFING / SIDING DUST
Asbestos Risk Assessment
Asbestos in Good Condition
Asbestos in Poor Condition
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
Asbestos Foamed-Over
Asbestos Air Ducts
Asbestos Air Duct Vibration Dampers
Asbestos Pipe Insulation
ASBESTOS MATERIAL REGULATIONS
ASBESTOS REGULATION Update
ASBESTOS REMOVAL, Wetting Guidelines
Asbestos Roofing Materials
Asbestos Roof Power Washing
ASBESTOS CEMENT & FIBER CEMENT SIDING
ASBESTOS in UNUSUAL PLACES
Carbon Nanotube Materials
CEILING TILES - Asbestos-Containing
Fireproofing containing Asbestos
ASBESTOS FLOOR TILE IDENTIFICATION
Paper Duct Insulation Containing Asbestos
TRANSITE PIPE AIR DUCTS
Transite Pipe Chimneys & Flues
Transite Pipe Water Supply Piping
Urea Formaldehyde Foam Insulation UFFI
VERMICULITE INSULATION
ASBESTOS PHOTO GUIDE to Materials
ASBESTOS REMOVAL, Wetting Guidelines
Asbestos Under the Microscope
INSULATION IDENTIFICATION GUIDE
INSULATION INSPECTION & IMPROVEMENT
INSULATION LOCATION - WHERE TO PUT IT
INSULATION MOLD
INSULATION R-Values & Properties

LEAD POISONING HAZARDS GUIDE

MOLD: A COMPLETE GUIDE to TEST CLEAN PREVENT
MOLD in FOAM INSULATION, RESISTANCE

Nanomaterials Hazards

  • 3/07: thanks to Gary Randolph, Ounce of Prevention Home Inspection, LLC Buffalo, NY, for attentive reading and editing suggestions. Mr. Randolph can be reached in Buffalo, NY, at (716) 636-3865 or email: gary@ouncehome.com
  • 06/07: thanks for photographs of transite asbestos heating ducts, courtesy of Thomas Hauswirth, Managing Member of Beacon Fine Home Inspections, LLC and (in 2007) Vice President, Connecticut Association of Home Inspectors Ph. 860-526-3355 Fax 860-526-2942 beaconinspections@sbcglobal.net
  • Thanks to reader GK October 2010 for discussing incompetent lead paint removal, lead paint dust contamination left indoors by the painting contractor, and how to clean up the lead paint dust mess.
  • Asbestos regulations for Ontario are published under the Occupational Health and Safety Act and are in Ontario Regulation 278/05 Web search 11/4/2010, original source: http://www.e-laws.gov.on.ca/html/regs/english/elaws_regs_050278_e.htm

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.

Asbestos Hazard, Testing, Removal, References & Products

  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • ASBESTOS IDENTIFICATION IN buildings How to find and recognize asbestos in buildings - visual inspection methods, list of common asbestos-containing materials
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • Asbestos in Good Condition
  • Asbestos in Good Condition
  • Asbestos in Your Home U.S. EPA, Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • Asbestos HVAC Ducts and Flues field identification photos and guide
  • Asbestos NESHAP Adequately Wet Guidance, EPA340/1-90-019, December 1990, U.S. ENVIRONMENTAL PROTECTION AGENCY, Office of Air Quality Planning and Standards, Stationary Source Compliance Division, Washington, DC 20460,original web source: http://www.epa.gov/region04/air/asbestos/awet.htm
  • Asbestos paper duct wrap
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print, text and images available at InspectAPedia.com).
  • Asbestos Transite Chimneys, Flues, & Pipes in buildings
  • Asbestos under the microscope
  • Asbestos Vibration Dampers & Asbestos in the Air Handler
  • Ceiling tiles: How to recognize ceiling tiles that may contain asbestos
  • Examples of unusual uses of asbestos in buildings
  • Fiberglass: Indoor Air Quality Investigations: Health Concerns About Airborne Fiberglass: Fiberglass in Indoor Air from HVAC ducts, and Building Insulation
  • Enviro-Scare: Electric Power Lines, Electromagnetic Fields, Cancer Risk, & "Enviro-Scare" - The Normal Curve Cycle of Public Fear of Environmental Issues
  • Dust from the World Trade Center collapse following the 9/11/01 attack: the lower floors of this building contained spray-on fire-proofing asbestos materials.
  • Asbestos Information Links: Asbestos Detection, Testing, Recognition, Hazards, Field Photos, and Information Sources, including health-related links such as legal services and information about mesothelioma and other cancers.
  • "Handling Asbestos-Containing roofing material - an update", Carl Good, NRCA Associate Executive Director, Professional Roofing, February 1992, p. 38-43
  • EPA Guidance for Controlling Asbestos-Containing Materials in buildings, NIAST, National Institute on Abatement Sciences & Technology, [republishing EPA public documents] 1985 ed., Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460

Home About Us Accuracy Contact Us Content Use Policy Printing Tips Privacy Website Description © 2012 Copyright InspectAPedia.com