| ||
| InspectAPedia® |
| |
Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair | Ask a Question or Search InspectAPedia |
Mobile ViewENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY AIR CLEANER PURIFIER TYPES AIR FILTER EFFECTIVENESS AIR FILTERS, FIBERGLASS PARTICLES AIR FILTERS for HVAC SYSTEMS AIR FILTERS, OPTIMUM INDOOR AIR FILTERS, SOURCES FOR AIR FILTERING STRATEGIES AIR FILTERING CONTINUOUS FAN OPERATION AIR HANDLER / BLOWER UNITS AIR LEAK DETECTION TOOLS AIR POLLUTANTS, COMMON INDOOR Air Quality Improvement Strategies AIR LEAK SEALING PROCEDURE AIR SEALING STRATEGIES AIR TEST FOR MOLD: ACCURACY AIR TEST SAMPLING CASSETTE STUDY AIRBORNE MOLD SPORE COUNT ACCURACY ALLERGEN TESTS for buildings ALLERGY TESTS for PEOPLE ALLERGY TEST ACCURACY ANIMAL ALLERGENS / PET DANDER ANIMAL ENTRY POINTS in buildings ASBESTOS CLEANUP COMPANIES ASBESTOS ROOFING / SIDING DUST ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings ASBESTOS AIR DUCTS Asbestos Air Duct Vibration Dampers ASBESTOS in CARPETING, PADDING ASBESTOS CEILING TILES, Asbestos-Containing ASBESTOS DUCTS, HVAC ASBESTOS DUCT INSULATION, Asbestos Paper ASBESTOS DUCTS, Transite Pipe ASBESTOS FIREPROOFING SPRAY-On Coatings ASBESTOS FLOOR TILE IDENTIFICATION ASBESTOS FLOOR TILE Laboratory Procedures ASBESTOS FLOOR TILE PHOTO ID GUIDE ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS FLOORING REMOVAL GUIDE Asbestos Foamed-Over ASBESTOS INSULATION ASBESTOS PAPER DUCT INSULATION ASBESTOS PIPE INSULATION ASBESTOS ROOFING, CEMENT & FIBER CEMENT Asphalt-asbestos Roofing Materials ASBESTOS ROOFING / SIDING DUST Cement-asbestos roof shingles Corrugated Cement-Asbestos Roofing Environmental Issues - Asbestos Roofing/Siding Maintenance Tips for Asbestos Cement Shingles OSHA Regulations, Asbestos Roofing, Siding Power Washing Asbestos Roofing Replacements for Asbestos Cement Shingles Roof Paint, Asphalt-asbestos sealants Warranty & Class Actions, Fiber Cement Shingles Wear Signs on Cement Asbestos Shingles ASBESTOS SIDING CEMENT & FIBER CEMENT Asbestos vs. fiber-cement ASBESTOS ROOFING / SIDING DUST Maintenance & Repair Asbestos Cement Shingles OSHA Regulations, Asbestos Roofing, Siding Painting Cement Asbestos Siding Remove & Replace Asbestos Cement Shingles Re-Sale Issues - Cement Asbestos siding Siding over asbestos cement Sources of Replacements for Asbestos Cement Shingles Tools to Cut Fiber Cement Shingles Wear signs on cement asbestos walls Asbestos in unusual places Asphalt-asbestos Paints & sealants Carbon Nanotube Materials TRANSITE PIPE AIR DUCTS Transite Pipe Chimneys & Flues Transite Pipe Water Supply Piping VERMICULITE INSULATION ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS FLOORING REMOVAL GUIDE ASBESTOS List of Asbestos-Containing Products ASBESTOS MATERIAL REGULATIONS ASBESTOS MATERIAL REGULATIONS Update ASBESTOS MATERIAL REGULATIONS, OSHA Roofing/Siding ASBESTOS Photo Guide to Materials / Products ASBESTOS REMOVAL, Amateur, Incomplete Asbestos Removal, Certification ASBESTOS REMOVAL GUIDE, FLOORING ASBESTOS REMOVAL, Wetting Guidelines ASBESTOS RISK ASSESSMENT Asbestos risk: in Good Condition Asbestos risk: in Poor Condition Asbestos Under the Microscope ATTORNEYS and EXPERT WITNESSES INSULATION IDENTIFICATION GUIDE ASBESTOS Photo Guide to Materials / Products ASBESTOS REMOVAL, Wetting Guidelines Asbestos Under the Microscope DUCTS - Asbestos DUCT INSULATION, Asbestos Paper DUCTS, Asbestos Transite Pipe FLOOR TYPES & DEFECTS FLOOR TILE ASBESTOS IDENTIFICATION FLOOR TILE HISTORY & INGREDIENTS INSULATION IDENTIFICATION GUIDE ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings Asbestos Pipe Insulation Balsam Wool Batt Insulation BLOWN-IN INSULATION BRICK LINED WALLS BRICK VENEER WALL INSULATION Cellulose loose fill insulation Ceramic Insulation Concrete insulation, light-weight Cotton Insulating Batts Fiberglass Insulation Foam Board Insulation Foam Insulation Types - Visual Id Homasote & Other Insulating Board Icynene Foam Spray Insulation Insects & Foam Insulation Mineral Wool - Rock Wool Insulation Mold in Fiberglass Insulation Mold on Books, Book Conservation Mold on Fiberboard Insulating Sheathing MOLD PREVENTION AFTER FLOODING MOLD RESISTANT CONSTRUCTION Mold in Foam Insulation Paper Duct Insulation Perlite Insulation PHENOLIC FOAM INSULATION POLYISOCYANURATE FOAM INSULATION POLYISOCYANURATE FOAM BELOW SLABS POLYSTYRENE FOAM INSULATION STRESS SKIN INSULATED PANELS STUCCO OVER FOAM INSULATION SUPER HI-R INSULATION SUPERINSULATION RETROFIT URETHANE FOAM Deterioration, Outgassing VERMICULITE INSULATION INSULATION INSPECTION & IMPROVEMENT More Information |
This article explains why, where & how to obtain replacement non-asbestos fiber cement shingles to repair or replace asbestos cement shingle siding. We discuss why & how to paint asbestos cement or fiber cement building siding. This document assists building buyers, owners or inspectors who need to identify asbestos materials (or probable-asbestos) in buildings by simple visual inspection. In the website sections listed below, we provide photographs and descriptive text of asbestos insulation and other asbestos-containing products to permit identification of definite, probable, or possible asbestos materials in buildings. While an expert lab test using polarized light microscopy may be needed to identify the specific type of asbestos fiber, or to identify the presence of asbestos in air or dust samples, many asbestos-containing building products not only are obvious and easy to recognize, but since there were not other look-alike products that were not asbestos, a visual identification of this material can be virtually a certainty in many cases. © Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Sources of Replacements for Asbestos Cement Wall ShinglesOne manufacturer of cement-asbestos shingles was Ruberoid Co., who made 8" x 16" tapered singles with a surface pattern resembling wood and called "Ru-Ber-Oid-Eternit Tapered Timbertex Asbestos-Cement Shingles." 260 singles/525 lbs/square, were available in a wide range of colors. Contemporary cement asbestos product manufacturers make reinforced fiber-cement wall and roofing shingles and other products which look like, perform similarly to, and need to be installed similarly to the original asbestos-cement shingles - but these new products are free of asbestos. The replacements for asbestos cement wall siding products are reinforced with a variety of fibers including fiberglass. Other replacements for asbestos-cement siding use both different fibers and a different aggregate (perlite) to replace the asbestos. Some of the substitute products have been in use for more than 30 years (2008). For maintenance or replacement of asbestos-cement wall siding or roof shingles (or wall siding) contact Supradur Manufacturing Corporation, PO Box 908, Rye NY 10580 800-223-1948, or from within New York State, call 914-967-8230. Ask about their Supradur(R) mineral fiber shingles. For handling and disposal guidance concerning old cement-asbestos wall siding material contact the US EPA, your state Department of Environmental Protection/Conservation, or your local building and health departments. Sources of Tools for Cutting Fiber Cement Shingles: Roofing Shingles or Wall Siding ShinglesWatch out: However very old, weathered and worn asbestos cement shingles, such as on a roof or sometimes on a wall that has been painted and is peeling, or roofing or wall cement asbestos shingles that are mishandled during demolition (breaking into many small pieces, running hand or power saws to cut the material) risks creating airborne asbestos-contaminated dust which could be a health and environmental hazard.
Added demolition and disposal cost of cement-asbestos productsAlso in some communities special measures and added costs are involved because of a requirement for air-testing during removal and possibly costs to dispose of the material in an appropriate landfill. (After all, originally this material came from the land.) Thanks to reader Van Moore for technical editing and requesting clarification. Painting Cement Asbestos Building SidingShould I paint my asbestos cement shingles? Do you need to use special paint for cement asbestos siding? Painting cement asbestos siding or non-asbestos fiber cement siding is mostly a cosmetic decision. We have never seen this material in a worn, friable condition, but should that occur, one might paint the surface also to stop fiber shedding and to preserve the material. Fiber cement shingles, both new non-asbestos product and the older asbestos-cement product are provided from the manufacturer with a coated surface, usually white. When the asbestos cement siding is soiled or moldy or has an algae coating we prefer to gently clean the surface with a sprayer, perhaps a deck cleaner solution. If you use a power washer be careful to spray "down" (to avoid blowing water into the building walls) and to keep far enough away that you do not damage the siding or "rough it up" which may cause more rapid deterioration or even fiber or asbestos release. But sometimes the asbestos cement or fiber cement shingles just look soiled and do not clean up enough to satisfy the homeowner. In general, this siding material can be painted using normal house paints. Check with your paint suppliers because some paints may not be recommended for the surface. But once you paint the siding, you've converted a "no maintenance" surface into one that will occasionally need to be re-painted for cosmetic reasons. Questions & Answers regarding this article. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
Recommend / Share this Article
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. ASBESTOS FLOORING HAZARD REDUCTIONASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings ASBESTOS ROOFING / SIDING DUST Asbestos Risk Assessment Asbestos in Good Condition Asbestos in Poor Condition ASBESTOS REMOVAL, Amateur, Incomplete Asbestos Removal, Certification Asbestos Foamed-Over Asbestos Air Ducts Asbestos Air Duct Vibration Dampers Asbestos Pipe Insulation ASBESTOS MATERIAL REGULATIONS ASBESTOS REGULATION Update ASBESTOS REMOVAL, Wetting Guidelines Asbestos Roofing Materials Asbestos Roof Power Washing ASBESTOS CEMENT & FIBER CEMENT SIDING Asbestos vs. fiber-cement Re-Sale Issues - Cement Asbestos siding Wear signs on cement asbestos walls Maintenance & Repair Asbestos Cement Shingles Remove & Replace Asbestos Cement Shingles Siding over asbestos cement Sources of Replacements for Asbestos Cement Shingles Painting Cement Asbestos Siding OSHA Asbestos Roof/Siding Regulations Asbestos in unusual places Carbon Nanotube Materials CEILING TILES - Asbestos-Containing Fireproofing containing Asbestos ASBESTOS FLOOR TILE IDENTIFICATION Paper Duct Insulation Containing Asbestos TRANSITE PIPE AIR DUCTS Transite Pipe Chimneys & Flues Transite Pipe Water Supply Piping Urea Formaldehyde Foam Insulation UFFI VERMICULITE INSULATION ASBESTOS Photo Guide to Materials / Products ASBESTOS REMOVAL, Wetting Guidelines Asbestos Under the Microscope MOLD in FOAM INSULATION, RESISTANCE ASBESTOS-FREE INSULATION MATERIALS INSULATION IDENTIFICATION GUIDE ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings Asbestos Pipe Insulation Balsam Wool Batt Insulation BLOWN-IN INSULATION BRICK LINED WALLS BRICK VENEER WALL INSULATION Cellulose loose fill insulation Ceramic Insulation Concrete insulation, light-weight Cotton Insulating Batts Fiberglass Insulation Foam Board Insulation Foam Insulation Types - Visual Id Homasote & Other Insulating Board Icynene Foam Spray Insulation Insects & Foam Insulation Mineral Wool - Rock Wool Insulation Mold in Fiberglass Insulation Mold on Books, Book Conservation Mold on Fiberboard Insulating Sheathing MOLD PREVENTION AFTER FLOODING MOLD RESISTANT CONSTRUCTION Mold in Foam Insulation Paper Duct Insulation Perlite Insulation PHENOLIC FOAM INSULATION POLYISOCYANURATE FOAM INSULATION POLYISOCYANURATE FOAM BELOW SLABS POLYSTYRENE FOAM INSULATION STRESS SKIN INSULATED PANELS STUCCO OVER FOAM INSULATION SUPER HI-R INSULATION SUPERINSULATION RETROFIT VERMICULITE INSULATION
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
Asbestos Hazard, Testing, Removal, References & Products
|
| Home | About Us | Accuracy | Contact Us | Content Use Policy | Privacy | Website Description | © 2012 Copyright InspectAPedia.com |