Mobile ViewENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY AGE of a BUILDING - how to determine ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings ASBESTOS AIR DUCTS Asbestos Air Duct Vibration Dampers ASBESTOS in CARPETING, PADDING ASBESTOS CEILING TILES, Asbestos-Containing ASBESTOS DUCTS, HVAC ASBESTOS DUCT INSULATION, Asbestos Paper ASBESTOS DUCTS, Transite Pipe ASBESTOS FIREPROOFING SPRAY-On Coatings ASBESTOS FLOOR TILE IDENTIFICATION Asbestos Floor Tile Laboratory Photos Asbestos Flooring Hazard Level of Risk Asbestos-containing Flooring Asbestos-containing Sheet Flooring How to Identify Asbestos Flooring Non-Asbestos Sheet Flooring Other Asbestos Floor Tiles Photos of Asbestos Flooring Unknown-brand 9x9 Vinyl-Asbestos Floor Tiles Unknown-brand 12x12 Vinyl-Asbestos Floor Tiles Vinyl Asbestos Floor Tile Dimensions Vinyl Asbestos Floor Tile Disposal Vinyl Asbestos Floor Tile Packaging ASBESTOS FLOOR TILE LAB PROCEDURES ASBESTOS FLOOR TILE PHOTO ID GUIDE FLOOR TILE HISTORY 1900-1986 Armstrong Floor Tiles Congoleum-Nairn Floor Tiles, Linoleum Ever-Wear Floor Tiles Kentile KenFlex Floor Tiles Montgomery Ward Floor Tiles Sears Roebuck Vinyl Asbestos Floor Tiles Self-Adhesive Stick-on Tiles, Asbestos Vinyl-Asbestos Floor Tile Photos Vinyl Asbestos Floor Tile Usage Guide Asbestos Foamed-Over ASBESTOS INSULATION ASBESTOS PAPER DUCT INSULATION ASBESTOS PIPE INSULATION ASBESTOS ROOFING, CEMENT & FIBER CEMENT ASBESTOS SIDING CEMENT & FIBER CEMENT ASBESTOS in UNUSUAL PLACES ASPHALT-ASBESTOS PAINT / SEALANT TRANSITE PIPE AIR DUCTS TRANSITE PIPE CHIMNEYS / FLUES TRANSITE PIPE WATER SUPPLY VERMICULITE INSULATION ASBESTOS FLOORING HAZARD REDUCTION Asbestos flooring health risks Friable Asbestos in Asbestos Floors Covering Asbestos Floor Tiles Disposing of Asbestos Flooring School Building Asbestos Flooring Managing Asbestos in Place ASBESTOS FLOORING REMOVAL GUIDE Floor Tile Removal Necessary? Removing Asbestos Flooring: Details ASBESTOS LIST of PRODUCTS ASBESTOS MATERIAL REGULATIONS ASBESTOS MATERIAL REGULATIONS Update ASBESTOS MATERIAL REGULATIONS, OSHA ASBESTOS PHOTO GUIDE to Materials ASBESTOS REMOVAL, Amateur, Incomplete Asbestos Removal, Certification ASBESTOS REMOVAL GUIDE, FLOORING ASBESTOS REMOVAL, Wetting Guidelines ASBESTOS RISK ASSESSMENT Asbestos risk: in Good Condition Asbestos risk: in Poor Condition Asbestos Under the Microscope INSULATION IDENTIFICATION GUIDE INTERIORS of buildings ACOUSTICAL SEALANT CHOICES AGE of a BUILDING - how to determine AIR BYPASS LEAKS AIR LEAK DETECTION TOOLS AIR LEAK MINIMIZATION AIR POLLUTANTS, COMMON INDOOR AIR LEAK SEALING PROCEDURE AIR SEALING STRATEGIES ANIMAL ALLERGENS APPLIANCE EFFICIENCY RATINGS ARCHITECTURE & BUILDING COMPONENT ID ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN buildings ASBESTOS LIST of PRODUCTS ASBESTOS PHOTO GUIDE to Materials ASBESTOS REMOVAL, Wetting Guidelines ATTIC LEAKS, CONDENSATION & MOLD ATTIC VENTILATION BASEMENT CEILING VAPOR BARRIER BASEMENT HEAT LOSS BASEMENT LEAKS, INSPECT FOR BASEMENT WATERPROOFING BATH & KITCHEN DESIGN GUIDE BATHROOM VENTILATION BEST CONSTRUCTION PRACTICES GUIDE BLOWER DOORS & AIR INFILTRATION BLOWER FAN CONTINUOUS OPERATION BLOWER FAN OPERATION & TESTING BLOWN-IN INSULATION BRICK LINED WALLS BRICK VENEER WALL INSULATION BRICK VENEER WALL Loose, Bulged BRICK WALL DRAINAGE WEEP HOLES BUCKLED FOUNDATIONS due to INSULATION? BUILDING NOISE DIAGNOSIS & CURE BUILDING SAFETY HAZARDS GUIDE CATHEDRAL CEILING INSULATION CATHEDRAL CEILING VENTILATION CEILING FINISHES INTERIOR CEILINGS, DROP or SUSPENDED PANEL CEILINGS, PLASTER TYPES CERAMIC TILE FLOOR, WALL CERAMIC TILE, ASBESTOS in? CHIMNEY INSPECTION DIAGNOSIS & REPAIR CHINESE DRYWALL HAZARDS COMBUSTION AIR for TIGHT buildings CONDENSING BOILERS/FURNACES DAMAGE CRAWL SPACES CONDENSATION or SWEATING PIPES, TANKS COOLING LOAD REDUCTION by ROOF VENTS DEHUMIDIFICATION PROBLEMS DEW POINT CALCULATION for WALLS DEW POINT TABLE - CONDENSATION POINT GUIDE EARTHQUAKE DAMAGED FOUNDATIONS EFFLORESCENCE, Salts & White / Brown Deposits ELDERLY & VETERANS HOME SAFETY ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR ENERGY SAVINGS in buildings ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY EXTERIOR WALL SIDING TRIM & FINISHES FIBERGLASS INSULATION FIBERGLASS HAZARDS FIBERGLASS INSULATION MOLD FLASHING MEMBRANES PEEL & STICK FLASHING for METAL ROOFS FLASHING ROOF WALL DETAILS FLASHING ROOF-WALL SNAFU FLASHING SIDING DETAILS FLASHING WALL DETAILS FLASHING WOOD ROOF DETAILS FLAT ROOF MOISTURE & CONDENSATION FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP FLOOD DAMAGED FOUNDATIONS FLOOD VENTS & FLOOD PORTS FLOODS IN buildings-mold FLOOR & SUBFLOOR MOLD, HIDDEN FLOOR TILE HISTORY & INGREDIENTS ASBESTOS FLOOR TILE IDENTIFICATION Asphalt-Asbestos Felt Flooring Asphalt-based Floor Tiles CERAMIC TILE, ASBESTOS in? Colors & Patterns - Age of Cork Flooring Tiles ENGINEERED WOOD Flooring Flooring Companies Mastic Used with Floor Tiles Resilient Floor List Vinyl Asbestos Floor Tile Age Vinyl-Asbestos Floor Tile History Vinyl Asbestos Floor Tile Packaging Vinyl Asbestos Floor Thickness & Dimensions Vinyl Asbestos Sheet Flooring LINOLEUM FLOORING Linoleum Sheet Flooring Age Non-Resilient Floor Coverings Peel and Stick Floor Tiles, Asbestos Peel and Stick Floor Tiles, Current Sheet Flooring Materials FLOOR TYPES & DEFECTS FOUNDATION WATERPROOFING FRENCH DRAINS FREEZE-PROOF A BUILDING FROST HEAVES, FOUNDATION, SLAB GREENHOUSE DESIGN for SOLAR HEATING HEAT LOSS in buildings HEAT LOSS DETECTION TOOLS HEAT LOSS INDICATORS HEAT LOSS PREVENTION PRIORITIES HEAT LOSS R U & K VALUE CALCULATION HEAT TAPES & CABLES on Roofs for Ice Dams HEATING COST SAVINGS METHODS HOT ROOF DESIGNS: Un-Vented Roof Solutions HOUSEWRAP AIR & VAPOR BARRIERS HOUSE DOCTOR, how-to be HUMIDITY LEVEL TARGET ICE DAM PREVENTION Ice Dams: Comparing Two Houses INDOOR AIR QUALITY & HOUSE TIGHTNESS INDOOR AIR QUALITY IMPROVEMENT GUIDE INSULATION CHOICES INSULATION FACT SHEET- DOE INSULATION for GREENHOUSE or SOLARIUM INSULATION IDENTIFICATION GUIDE INSULATION INSPECTION & IMPROVEMENT INSULATION LOCATION - WHERE TO PUT IT INSULATION MOLD INSULATION R-Values & Properties LOG HOME GUIDE MOBILE HOME INSPECTIONS MOISTURE CONTROL in BUILDINGS MOLD INFORMATION CENTER Nanomaterials Hazards NOISE / SOUND DIAGNOSIS & CURE NOISE, AIR CONDITIONER COMPRESSOR NOISE, DUCT VIBRATION DAMPENERS NOISE CONTROL for HEATING SYSTEMS NOISE CONTROL for FLOORS NOISE CONTROL for PLUMBING NOISE CONTROL for ROOFS NOISES COMING FROM WATER HEATER ODORS & SMELLS DIAGNOSIS & CURE PAINT FALURE, DIAGNOSIS, CURE, PREVENTION PASCAL CALCULATIONS PLASTER & BEAVERBOARD & DRYWALL PLASTER BULGES & PILLOWS PLASTER LATH, METAL PLASTER, LOOSE FALL HAZARDS PLASTER TYPE IDENTIFICATION PLASTER VENEER Best Practices RADIANT BARRIERS RADIANT HEAT RADIANT HEAT Floor Mistakes to Avoid RADIANT HEAT TEMPERATURES RADIANT SLAB FLOORING CHOICES RADIANT SLAB TUBING & FLUID CHOICES ROOF VENTILATION SPECIFICATIONS ROT, FUNGUS, TERMITES ROT, TIMBER FRAME SAFETY HAZARDS & INSPECTIONS MSDS Material Safety Data Sheets SEARS KIT HOUSES SINKHOLES, WARNING SIGNS SINKING BUILDINGS SLAB CRACK EVALUATION SOLAR ENERGY SYSTEMS SOUND CONTROL in buildings Splits in Structural Wood Beams STAIN & BIODETERIORATION AGENT CATALOG STAINS on buildings - QUICK GUIDE STAIN DIAGNOSIS on BUILDING EXTERIORS STAIN DIAGNOSIS on BUILDING INTERIORS STAIN DIAGNOSIS on ROOFS STAIN DIAGNOSIS on STONE STAINS on INDOOR SURFACES: PHOTO GUIDE STAIRS, RAILINGS, LANDINGS, RAMPS STONE CLEANING METHODS STONE VENEER WALLS STUCCO WAll FAILURES DUE TO WEATHER STUCCO WALL METHODS & INSTALLATION STUCCO OVER FOAM INSULATION STUCCO PAINT FAILURES SUMP PUMPS GUIDE SWEATING (CONDENSATION) on PIPES, TANKS THERMAL EXPANSION of MATERIALS THERMAL MASS in buildings THERMAL TRACKING Indicates Heat Loss VAPOR BARRIERS & CONDENSATION in BUILDINGS VENTILATION in buildings VINYL Siding or PLASTIC Window ODORS in buildings VINYL CHLORIDE HEALTH INFO WATER ENTRY in buildings WINDOWS & DOORS WINTERIZE A BUILDING WOOD Burning Heaters Fireplaces Stoves More Information |
Congoleum asbestos flooring identification: this article provides a guide to identifying Congoleum-Nairn asphalt-asbestos, vinyl asbestos floor tiles, linoleum, and sheet flooring (resilient flooring) materials that are reported to contain asbestos, or that have been confirmed as containing asbestos in asbestos fiber or asbestos powder-filler form. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. Styles, & Pictures of Congoleum-Nairn Vinyl-Asbestos Floor Tiles & Congoleum Linoleum Sheet Flooring: Resilient FloorsAsbestos is safe and legal to remain in homes or public buildings as long as the asbestos materials are in good condition and the asbestos can not be released into the air.
Don't Mix Up Congoleum Nairn Resilient Flooring with Armstrong FloorsCongoleum Sheet Flooring Products Resembling Individual Floor Tiles
At above left is a continuous resilient Congoleum Nairn sheet flooring product that was colored to resemble individual floor tiles in red, black,and white The Congoleum-Nairn company advertised that this approach was less costly and quicker to install than tiles, and permitted better control over tile color consistency. Above right our photograph excerpted from another 1950's flooring advertisement shows a Congoleum sheet floor used in a kitchen and dining area. Congoleum Gold Seal Rugs and Nairn LinoleumAsbestos-Containing Flooring Product Identification Article ListAsphalt-based asbestos floor tiles and vinyl-asbestos floor tiles are identified and described in this article series where we also provide many identifying tile and sheet flooring photographs of various flooring patterns and colors. These flooring products typically contain chrysotile asbestos, and possibly other asbestos forms. See these articles on types, ages, characteristics, ingredients, & inspection of different types of floor coverings:
We discuss the history and manufacture of asphalt-asbestos floor tiles in our Age of House articles at Flooring Materials. We discuss the inspection, diagnosis, and repair of various flooring products at FLOOR TYPES & DEFECTS.Also see Asbestos HVAC Ducts a field identification guide to visual detection of asbestos in and on heating and cooling system ducts and flue vents . Also see Micro-Photographs of Dust from the World Trade Center collapse following the 9/11/01 attack. Links to U.S. government and other authoritative research and advice are included. Questions & Answers regarding this article. Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...