Photographs of green mold in buildings - how to recognize mold
Photographs of green mold in buildings assist in spotting problem mold growth in attics, basements, and in the living area
Photos of green mold of various green shades/colors and textures in buildings
Questions & answers about green colored mold contamination in buildings
What does green mold look like on indoor building surfaces? These mold spores and their photographs and examples of materials sometimes mistaken for mold have been collected
in the U.S., Spain, Mexico, France, as well as in other countries where I've studied bioaerosols. These photos of mold on indoor building surfaces may help you recognize
mold in buildings, recognize probably-cosmetic mold, and recognize stuff that is not mold and does not need to be tested.
InspectAPedia offers impartial, unbiased advice without conflicts of interest.
We will block advertisements which we discover or readers inform us are associated with bad business practices,
false-advertising, or junk science. Our contact info is at
InspectAPedia.com/Contact.htm.
Photographs to Help Identify Mold in buildings -
What mold looks like in a home or other buildings
Identification Photographs of Green Mold in buildings
Among the 1.5 million mold species, there are quite a few that may be found in buildings and that are green or green-gray in color. Three very common indoor mold groups found indoors and that include visible green mold growth are some members of the Aspergillus sp., Penicillium sp., and Trichoderma sp. mold genera.
Green mold can be easily seen on building surfaces but it cannot be reliably identified to genera/species without analysis by a qualified aerobiologist/microscopist in a test lab. See Mold Atlas & Particles List for an atlas of building molds and for more microphotographs of building mold samples observed in our laboratory. See our Atlas of Mold Related Illness Symptoms & Complaints for details about specific mold genera/species and their health effects. Also see Mold spores in the Home - a Photo ID Library for detection and identification of mold allergens
on indoor building surfaces.
Our photographs which follow show the typical appearance of green and gray-green molds on building surfaces indoors.
This photograph of thick green mold growth appearing on
plywood subflooring over a wet crawl space was taken at a vacation home located at the edge of a lake.
The combination of wet soils,
roof spillage against the foundation, and long periods of inattention subjected this house to water damage and problematic mold growth.
This photograph of thick green mold growth was taken on cardboard boxes and contents stored in a basement closet subjected to not only leaks through a foundation wall but also recurrent basement flooding.
The presence of black mold and white mold on this box suggest that we may have at least three different genera/species of mold growing in this area.
You can also see tan colored mold on the wooden picture frame on which this box sits, and white mold growing on the cigar boxes at the lower right of the photo.
This photograph shows thick green mold growth on furniture, side-lit by our flashlight. the Green mold on furniture in a damp moldy basement, Aspergillus photo shown in thumbnail just below is a larger view of this item.
Our lab examination determined that this mold, which was quite green to the naked eye, also contained Aspergillus niger (a black mold in the microscope).
Interestingly this very moldy furniture had been in this (very wet) location only three weeks according to our client.
Green mold on drywall in a flooded basement, or blue-green mold is shown in this photograph. The mysteriously-sharp line marking the top edge
of this mold growth was very important.
Dissection of the wall showed that a 12-inch strip of drywall had been removed and replaced around the entire room perimeter. The mold growth line marked the cut edge and taped-over repair - and a change in moisture
levels of the materials which slowed mold spread above this point.
A previous owner had repaired previous water and flood
damage in this basement. This is an example of the exception to the general rule that mold growth tends to spread in a non-linear pattern over surfaces.
Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
Additional technical contributors & reference sources for this article are listed below.
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
Kansas State University, department of plant pathology, extension plant pathology web page on wheat rust fungus: see http://www.oznet.ksu.edu/path-ext/factSheets/Wheat/Wheat%20Leaf%20Rust.asp
"A Brief Guide to Mold, Moisture, and Your Home",
U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
Allergen Tests in buildings advice about how to test, what to look for, in evaluating the level of dog, cat, or other animal allergens in a building
"IgG Food Allergy Testing by ELISA/EIA, What do they really tell us?" Sheryl B. Miller, MT (ASCP), PhD, Clinical Laboratory Director, Bastyr University Natural Health Clinic - ELISA testing accuracy: Here is an example of Miller's critique of ELISA
http://www.betterhealthusa.com/public/282.cfm - Townsend Letter for Doctors and Patients
The critique included in that article raises compelling questions about IgG testing assays, which prompts our interest in actually screening for the presence of high levels of particles that could carry allergens - dog dander or cat dander in the case at hand.
http://www.tldp.com/issue/174/IgG%20Food%20Allergy.html contains similar criticism in another venue but interestingly by the same author, Sheryl Miller. Sheryl Miller, MT (ASCP), PhD, is an Immunologist and Associate Professor of Basic and Medical Sciences at Bastyr University in Bothell, Washington. She is also the Laboratory Director of the Bastyr Natural Health Clinic Laboratory.
Allergens: Testing for the level of exposure to animal allergens is discussed at http://www.animalhealthchannel.com/animalallergy/diagnosis.shtml (lab animal exposure study is interesting because it involves a higher exposure level in some cases
Allergens: WebMD discusses allergy tests for humans at webmd.com/allergies/allergy-tests
Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
Recognizing Allergens: What various indoor allergens look like - identification photos to help identify pollen, dust mites, animal dander, toxic or allergenic mold - Common Mold and other Allergens, Irritants, Remedies & Advice
Rodent control issues, including dander, fecal, and urine contamination of buildings and Building insulation are discussed at our
Associations: Sick House, Sick Building, SBS - Air Quality, Government, Private Associations and Information Resources
Atlas of Clinical Fungi, 2nd Ed., GS deHoog, J Guarro, J Gene, & MJ Figueras, Centraalbureau voor Schimmelcultures, Universitat Rovira I Virgili, 2000, ISBN 90-70351-43-9 (you can buy this book at Amazon)
Atlas of Indoor Mold, Online Clinical Mold Atlas, Toxins, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
Black Mold that is Harmless Photos of recognizable, usually harmless black mold on wood, bluestain, ceratocystis, ophistoma
Building Floods: quick steps after a building flood or plumbing leak can prevent costly mold contamination
Classes of Mold: what types of cosmetic, allergenic, or toxic mold are a problem? Can mold be cleaned-up successfully?
"A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
"Disease Prevention Program for Certain Vegetable Crops," David B. Langston, Jr., Extension Plant Pathologist - Vegetables, University of Georgia (PDF document) original source: www.reeis.usda.gov/web/crisprojectpages/209797.html
"Disease Prevention in Home Vegetable Gardens,"
Patricia Donald,
Department of Plant Microbiology and Pathology,
Lewis Jett
Department of Horticulture, University of Missouri Extension - extension.missouri.edu/publications/DisplayPub.aspx?P=G6202
Fifth Kingdom, Bryce Kendrick, ISBN13: 9781585100224, is available from the InspectAPedia online bookstore - we recommend the CD-ROM version of this book. This 3rd/edition is a compact but comprehensive encyclopedia of all things mycological. Every aspect of the fungi, from aflatoxin to zppspores, with an accessible blend of verve and wit. The 24 chapters are filled with up-to-date information of classification, yeast, lichens, spore dispersal, allergies, ecology, genetics, plant pathology, predatory fungi, biological control, mutualistic symbioses with animals and plants, fungi as food, food spoilage and mycotoxins.
OTHER IAQ ISSUES: How To Find and Address Other Indoor Air or Indoor Environment Contaminants Besides Mold
Mold or allergens may not be the only or even the main indoor environmental contaminant. Don't let media attention to mold
cause so much enviro-scare fear that other, possibly more urgent hazards go un-addressed.
Ozone Warnings - Use of Ozone as a "mold"
remedy is ineffective and may be dangerous.
Pet control - if you can't say goodbye to your bird, cat, dog, guinea pig, hamster, tropical fish, then limit the
areas they occupy and limit the airflow from that area to sleeping or other areas of the building, use allergenic
bedding, eliminate wall-to-wall carpeting, improve housecleaning including use of a HEPA-rated vacuum cleaner. For more details
see our article Dog, Cat, and Other Animal Dander - Information for Asthmatics and Indoor Air Quality
Rodents, Mice, Squirrel Control - I find high levels of mouse and rodent dander, fecal dust, and urine-contaminated dust in some buildings,
and high levels of these materials in building insulation in those locations. If you have a mouse problem, particularly if mice and their waste (fecals or urine) are contaminating
the building HVAC or building insulation, may need both steps to clean up or remove infected materials and steps to stop an ongoing
rodent problem. If squirrels are a problem, the cleanup needs to include closing off entry openings into the building. Get some
help from a licensed pest control expert.