InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical | Indoor
Environment
| Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


ENVIRONMENTAL HAZARDS GUIDE
AIR POLLUTANTS, COMMON INDOOR
ALLERGEN TESTS for BUILDINGS
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
FLOODS IN BUILDINGS-priorities
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
MOLD: A COMPLETE GUIDE TO MOLD
MOLD INFORMATION CENTER
ACCURACY OF VARIOUS MOLD TEST METHODS
  Causes of Variation in Airborne Particle Levels
  Indoor vs. Outdoor Spore Counts
  Extent of Variation of Airborne Particle Counts
  Particle Levels vs Sampler Height
  Particle Levels vs Windows/Doors
  Particle Levels in Ducts
  Concentration Bursts of Mold Spores
  False Negative Results in Mold Tests
  Mold Culture Plate Test Errors
  Why Use Airborne Mold/Particle Sampling?
  Visual Inspection and History for Mold
ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
ALLERGEN TESTS for BUILDINGS
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
CLEARANCE INSPECTIONS - MOLD CLEANUP
DO IT YOURSELF MOLD CLEANUP
ENERGY SAVINGS in BUILDINGS
ENERGY SAVINGS PRIORITIES
ENERGY SAVINGS RETROFIT CASE STUDY
ENERGY SAVINGS RETROFIT LEAK SEALING GUIDE
ENERGY SAVINGS RETROFIT OPTIONS
FIND MOLD in BUILDINGS, HOW TO
FUNGICIDAL SPRAY & SEALANT USE GUIDE
HIDDEN MOLD, HOW TO FIND
HUMIDITY CONTROL TO PREVENT MOLD
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INDOOR AIR QUALITY METHODS COMPARED
LEAD POISONING HAZARDS GUIDE
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOISTURE CONTROL in BUILDINGS
MOLD: A COMPLETE GUIDE TO MOLD
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD AGE - Old is the Mold?
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD ATLAS & PARTICLES INDEX
MOLD BY MICROSCOPE
MOLD CLASSES, HAZARD LEVELS
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD REMEDIATION CLEARANCE INSPECTION
MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTOR?
MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS
MOLD INSPECTORS & MOLD TESTERS
MOLD LEVEL IN AIR, VALIDITY
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS
MOLD by MICROSCOPE
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD RELATED ILLNESS SYMPTOMS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES
ODORS, Smells, Gases in Buildings-Diagnosis & Cure
RENTERS & TENANTS GUIDE TO MOLD
SEWAGE BACKUP TEST & CLEANUP
STAIN DIAGNOSIS
TECHNICAL & LAB PROCEDURES
THERMAL TRACKING

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Photograph of Allergenco Mark III Impaction Air Sampler Mold Mold Concentration Burst Error in Mold Tests
InspectAPedia®  -    

  • What are Mold Concentration Bursts and how do they cause Errors in Mold Tests when using Air Sampling?
  • What are the sources of variation in the mold level that air tests can detect?
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

Here we explain what Mold Concentration Bursts are and we explain how mold concentration bursts cause Error in Mold Tests when Air Sampling. This document is a brief tutorial which provides information about the accuracy of and sources of errors in tests for the level of allergenic and toxic mold in residential buildings: Are spore counts valid? Are cultures and swab tests valid? These critical questions are discussed in this paper. Readers should also see MOLD LEVEL IN AIR, VALIDITY, and for a more in-depth critique of popular mold testing methods than this tutorial see MOLD TESTING METHOD VALIDITY

© Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Concentration Bursts of Mold Spores Cause Variation in Indoor or Outdoor Mold Level Counts

ACGIH Bioaerosols: Assessment and Remediation states [section 1.2.3]:
Some organisms and sources release aerosols as 'concentration bursts' which may only rarely be detected by limited grab sampling and may be masked in measurements of long-term average concentrations. Nevertheless, such episodic bioaerosol releases may produce significant health effects. -- thanks to S. Flappan for suggesting this citation.

Spores are not always airborne during sampling: Mold spores may not be in interior air at the time of the sample but may be present in high levels at other times. Particle level in air varies very continuously as a function of temperature, humidity, size, mechanical disturbance, HVAC operation, use of fans and vacuum cleaners, and other factors as simple as foot traffic through a building.

Concentration bursts of mold spores: An example of a concentration burst of Aspergillus sp. spores occurred during our inspection and monitoring of a college library with many moldy books in its basement. Initially, though there was a large area of visible green mold (Aspergillus sp.) on many books on shelves in the library basement, while conditions there were still quite damp (humidity 65-75% RH) the airborne Aspergillus sp. spore levels were rather low.

But when the college brought in an "expert" who installed commercial dehumidifiers (without cleaning or removing the mold) the airborne Aspergillus sp. skyrocketed. As the humidity dropped the fungus responded by releasing spores.

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ENVIRONMENTAL HAZARDS GUIDE
AIR POLLUTANTS, COMMON INDOOR
ALLERGEN TESTS for BUILDINGS
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
FLOODS IN BUILDINGS-priorities
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
MOLD: A COMPLETE GUIDE TO MOLD
MOLD INFORMATION CENTER
ACCURACY OF VARIOUS MOLD TEST METHODS
  Causes of Variation in Airborne Particle Levels
  Indoor vs. Outdoor Spore Counts
  Extent of Variation of Airborne Particle Counts
  Particle Levels vs Sampler Height
  Particle Levels vs Windows/Doors
  Particle Levels in Ducts
  Concentration Bursts of Mold Spores
  False Negative Results in Mold Tests
  Mold Culture Plate Test Errors
  Why Use Airborne Mold/Particle Sampling?
  Visual Inspection and History for Mold
ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
ALLERGEN TESTS for BUILDINGS
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
CLEARANCE INSPECTIONS - MOLD CLEANUP
DO IT YOURSELF MOLD CLEANUP
ENERGY SAVINGS in BUILDINGS
ENERGY SAVINGS PRIORITIES
ENERGY SAVINGS RETROFIT CASE STUDY
ENERGY SAVINGS RETROFIT LEAK SEALING GUIDE
ENERGY SAVINGS RETROFIT OPTIONS
FIND MOLD in BUILDINGS, HOW TO
FUNGICIDAL SPRAY & SEALANT USE GUIDE
HIDDEN MOLD, HOW TO FIND
HUMIDITY CONTROL TO PREVENT MOLD
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INDOOR AIR QUALITY METHODS COMPARED
LEAD POISONING HAZARDS GUIDE
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOISTURE CONTROL in BUILDINGS
MOLD: A COMPLETE GUIDE TO MOLD
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD AGE - Old is the Mold?
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD ATLAS & PARTICLES INDEX
MOLD BY MICROSCOPE
MOLD CLASSES, HAZARD LEVELS
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD REMEDIATION CLEARANCE INSPECTION
MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTOR?
MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS
MOLD INSPECTORS & MOLD TESTERS
MOLD LEVEL IN AIR, VALIDITY
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS
MOLD by MICROSCOPE
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD RELATED ILLNESS SYMPTOMS
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES
ODORS, Smells, Gases in Buildings-Diagnosis & Cure
RENTERS & TENANTS GUIDE TO MOLD
SEWAGE BACKUP TEST & CLEANUP
STAIN DIAGNOSIS
TECHNICAL & LAB PROCEDURES
THERMAL TRACKING

  • Thanks to Susan Flappan, Flappan Consulting, moldetect.com, Overland Park KS, 913-402-1131, for contributing comments and some suggested text from ACGIH Bioaerosols: Assessment and Remediation 12/2006.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

ENVIRONMENTAL HAZARDS GUIDE

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

02/08/2010 - 01/22/1997 - InspectApedia.com/sickhouse/MoldConcentration.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark