ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

MOLD: A COMPLETE GUIDE to TEST CLEAN PREVENT

ACCEPTABLE MOLD LEVEL
ACCURACY OF VARIOUS MOLD TEST METHODS
ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
ACTIVITY of MOLD in BUILDINGS
AGE of MOLD - Old is the Mold?

AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY
AIRBORNE MOLD SPORE COUNT ACCURACY
AIRBORNE PARTICLE ANALYSIS METHODS

ALLERGEN TESTS for BUILDINGS
ALLERGENS in BUILDINGS, RECOGNIZING
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY

ATTORNEYS and EXPERT WITNESSES
ATTIC MOLD

BASEMENT MOLD
BASEMENT MOLD WATER IMPACT
BASICS YOU NEED to FIND, TEST, REMOVE MOLD
BASKETBALL MOLD SYNDROME - BBMS
BATHROOM MOLD
BROWN HAIRY BATHROOM MOLD

BIBLIOGAPHY for ENVIRONMENTAL HEALTH, MOLD, IAQ
BIOLOGICAL POLLUTANTS
BIOLOGICAL POLLUTANTS in the HOME - EPA
Bisphenol-A, BPA

BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC

BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
BUY PRODUCTS for MOLD & ALLERGY CONTROL
BUYERS GUIDE - home inspections for mold

CARPET DUST IDENTIFICATION
CARPET MOLD CONTAMINATION
CARPET PADDING ASBESTOS, MOLD, ODORS
CARPET FUNGICIDAL SPRAY
CARPET STAIN DIAGNOSIS
CARPET & other STAIN TESTS
CARPET TEST GUIDE
CARPETING & INDOOR AIR QUALITY
CARPETING, SELECTION & INSTALLATION

CHAIN OF CUSTODY - TEST SAMPLE

CLEARANCE INSPECTIONS - MOLD CLEANUP
CONSTRUCTION DETAILS TO AVOID MOLD
CRAWL SPACES

DIRT FLOOR MOLD CONTAMINATION
DO IT YOURSELF MOLD CLEANUP
DO-IT-YOURSELF MOLD CLEANUP WARNINGS
DRYWALL MOLD

DUCT SYSTEM & DUCT DEFECTS
DUST ANALYSIS for FIBERGLASS
DUST CONTAMINATION FROM HVAC?
DUST SAMPLING PROCEDURE

EFFLORESCENCE, Salts & White / Brown Deposits
ESSENTIAL STEPS IN FINDING MOLD

FEAR of MOLD - MYCOPHOBIA
Fiberboard Insulation Sheathing Mold

FIBERGLASS INSULATION MOLD
FIBERGLASS PARTICLE CONTAMINATION TEST

FIELD INVESTIGATION SERVICE

FIND MOLD, ESSENTIAL STEPS
FIND MOLD in BUILDINGS, HOW TO

FIRE DAMAGE vs MOLD DAMAGE

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODS IN BUILDINGS-mold

FLOORING MATERIALS, Age, Types

FUNGICIDAL SPRAY & SEALANT USE GUIDE

GAS DETECTION & MEASUREMENT
GASES, EXPOSURE, TESTING
GAS EXPOSURE EFFECTS, TOXIC
GAS EXPOSURE TEST PROCEDURES
GAS TOXICITY LEVELS
GAS PIPING, VALVES, CONTROLS

House Dust Analysis

HOUSEWRAP AIR & VAPOR BARRIERS

HIDDEN MOLD, HOW TO FIND
HUMIDITY CONTROL & TARGETS INDOORS

INDOOR AIR HAZARDS TABLE
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE

INSULATION MOLD
ITCHY FABRICS

LABORATORY SERVICES
LAB PROCEDURES MICROSCOPE TECHNIQUES
LEAD POISONING HAZARDS GUIDE

Legionella Legionnaires' Disease
Legionella BACTERIA & HVAC Equipment
LP & Natural Gas Safety Hazards

MEDIA BLASTING for MOLD REMOVAL
METHANE GAS SOURCES
MICROSCOPE DIGITAL PHOTOGRAPHY
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOISTURE CONTROL in BUILDINGS

MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD ACTIVITY in BUILDINGS
MOLD AGE - Old is the Mold?
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD ATLAS & PARTICLES INDEX

MOLD by MICROSCOPE
MOLD in the PETRI DISH, PHOTOS
Mold on Books, Book Conservation

MOLD CLASSES, HAZARD LEVELS

MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP - BLEACH
MOLD CLEANUP - HEALTH RISKS
MOLD CLEANUP - LIMITATIONS
MOLD CLEANUP - MISTAKES to AVOID
MOLD CLEANUP - MEDIA BLASTING
MOLD CLEANUP - SAFETY WARNINGS
MOLD CLEANUP - WOOD FLOORING
MOLD CLEANUP - WOOD FRAMING & PLYWOOD

MOLD CLEARANCE INSPECTIONS
MOLD CLEARANCE: FOLLOWUP STEPS

MOLD CLINICAL REFERENCE TEXTS

MOLD CONSULTANTS/INSPECTORS

MOLD CONTAMINATION LEVELS
MOLD CONTAMINATION LEVELS, SPECIFIC

MOLD CULTURE PHOTOS
MOLD CULTURE TEST KIT VALIDITY
MOLD CULTURE SAMPLING METHOD

MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTORS - ENVIRONMENTAL MEDICINE

MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE, FOOD HAZARDS
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS
  MOLD CONTAMINATION LEVELS
    MOLD CULTURES
    AIRBORNE MOLD SPORE COUNTS
    MOLD CONTAMINATION LEVELS
  MOLD TOXICITY VARIATION
    MOLD PARTICLE TOXICITY
    VIABLE vs NON-VIABLE MOLD SPORES
  MOLD STANDARDS - GOVERNMENT
  MOLD STANDARDS - WORLD WIDE
    Australian Mould Guidelines
    California Mold Disclosure Law
    Canadian Mould Guidelines
    Canadian National Toxic Mold Centre
    European Union Mold Standards
    New York City Mold Guidelines
    OSHA Guide to Workplace Mold
    World Health Organization Mold Bulletin
MOLD FAQ's
MOLD FREQUENCY in BUILDINGS
MOLD GROWTH ON SURFACES, PHOTOS
MOLD GROWTH on SURFACES, TABLE OF
MOLD GROWTH in/on BUILDING INSULATION

MOLD INFORMATION CENTER
MOLD INSPECTORS & MOLD TESTERS
MOLD INSPECTION SERVICE
MOLD INVESTIGATION PROCEDURE TIPS
MOLD INVESTIGATION REPORTS

MOLD KILLING GUIDE
MOLD LAB REPORTS

MOLD LEVEL IN AIR, VALIDITY
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS
MOLD by MICROSCOPE
MOLD ODORS, MUSTY SMELLS
MOLD on or in CARPETS
MOLD ON DIRT FLOORS

MOLD PREVENTION GUIDE

MOLD RELATED ILLNESS GUIDE
MOLD RELATED ILLNESS SYMPTOMS
MOLD RESISTANT CONSTRUCTION

MOLD SAFETY WARNINGS
MOLD SPRAYS, SEALANTS, PAINTS

MOLD STANDARDS
MOLD STANDARDS - GOVERNMENT
MOLD STANDARDS - WORLD WIDE

MOLD TOXICITY VARIATION
MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES

MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE
OZONE for MOLD OR ODORS

PAINTS & COATINGS ODORS IN BUILDINGS
Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
POLLEN Photographs

RENTERS & TENANTS GUIDE TO MOLD
ROBIGUS & Wheat Rust Fungus
ROT, TIMBER FRAME

SLIDE PREPARATION, MICROSCOPE

SMELL PATCH TEST to Track Down Odors

SLIDE PREPARATION, MICROSCOPE
SOUND CONTROL in BUILDINGS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on BUILDINGS - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAINS & Thermal Tracking

TECHNICAL & LAB PROCEDURES
THERMAL TRACKING Indicates Heat Loss
TRAPPED MOLD BETWEEN WOOD SURFACES

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in BUILDINGS

WALL SIDING TRIM & FINISHES
WALL FINISHES INTERIOR

WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in BUILDINGS
WATER ODORS, CAUSE CURE

More Information

Photograph of a mold culture plate home test kit for mold. OSHA Guide to Mold in the Workplace
InspectAPedia®  -         

  • US OSHA Guide to Workplace Mold Standards & Advice
  • Questions & answers about on-the-job mold contamination or mold exposure risks

This article presents OSHA's guide to mold contamination in the workplace, with additional commentary, annotations, and links to additional information and details about the cause, detection, cure, & prevention of mold contamination in buildngs.

InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. our contact info is at InspectAPedia.com/Contact.htm.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Note: in this free InspectAPedia.com copy of the OSHA document we have made minor changes to text spacing and headings for clarity. None of the OSHA Mold Guide document content has been amended.

U. S. Department of Labor
Occupational Safety and Health Administration
Directorate of Science, Technology and Medicine
Office of Science and Technology Assessment

A Brief Guide to Mold in the Workplace

This Safety and Health Information Bulletin is not a standard or regulation, and it creates no new legal obligations. The Bulletin is advisory in nature, informational in content, and is intended to assist building managers, custodians, and others who are responsible for building maintenance. Contractors and other professionals (e.g., environmental consultants and health or safety professionals) who respond to mold and moisture situations in buildings, as well as members of the general public, also may want to refer to these guidelines.

The Occupational Safety and Health Act requires employers to comply with hazard-specific safety and health standards as issued and enforced by either the Federal Occupational Safety and Health Administration (OSHA), or an OSHA-approved State Plan. In addition, Section 5(a)(1), the General Duty Clause, requires employers to provide their employees with a workplace free from recognized hazards likely to cause death or serious physical harm.

Employers can be cited for violating the General Duty Clause if there is such a recognized hazard and they do not take reasonable steps to prevent or abate the hazard. However, failure to implement these guidelines is not, in itself, a violation of the General Duty Clause. Citations can only be based on standards, regulations, and the General Duty Clause.

Introduction to Mold in the Workplace

Concern about indoor exposure to mold has increased along with public awareness that exposure to mold can cause a variety of health effects and symptoms, including allergic reactions. This safety and health information bulletin provides recommendations for the prevention of mold growth and describes measures designed to protect the health of building occupants and workers involved in mold cleanup and prevention. This bulletin is directed primarily at building managers, custodians, and others responsible for building maintenance, but may also be used as a basic reference for those involved in mold remediation.

By reading this safety and health information bulletin, individuals with little or no experience with mold remediation may be able to reasonably judge whether mold contamination can be managed in-house or whether outside assistance is required. The advice of a medical professional should always be sought if there are any emerging health issues. This document will help those responsi ble for building maintenance in the evaluation of remediation plans.

Contractors and other professionals (e.g. industrial hygienists or other environmental health and safety professionals) who respond to mold and moisture situations in buildings, as well as members of the general public, also may find these guidelines helpful. The information in these guidelines is intended only as a summary of basic procedures and is not intended, nor should it be used, as a detailed guide to mold remediation. These guidelines are subject to change as more information regarding mold contamination and remediation becomes available.

Mold Basics

Molds are part of the natural environment. Molds are fungi that can be found anywhere - inside or outside - throughout the year. About 1,000 species of mold can be found in the United States, with more than 100,000 known species worldwide.

Outdoors, molds play an important role in nature by breaking down organic matter such as toppled trees, fallen leaves, and dead animals. We would not have food and medicines, like cheese and penicillin, without mold.

Indoors, mold growth should be avoided. Problems may arise when mold starts eating away at materials, affecting the look, smell, and possibly, with the respect to wood-framed buildings, affecting the structural integrity of the buildings.

Molds can grow on virtually any substance, as long as moisture or water, oxygen, and an organic source are present. Molds reproduce by creating tiny spores (viable seeds) that usually cannot be seen without magnification. Mold spores continually float through the indoor and outdoor air.

Molds are usually not a problem unless mold spores land on a damp spot and begin growing. They digest whatever they land on in order to survive. There are molds that grow on wood, paper, carpet, foods and insulation, while other molds feast on the everyday dust and dirt that gather in the moist regions of a building.

When excessive moisture or water accumulates indoors, mold growth often will occur, particularly if the moisture problem remains uncorrected. While it is impossible to eliminate all molds and mold spores, controlling moisture can control indoor mold growth.

All molds share the characteristic of being able to grow without sunlight; mold needs only a viable seed (spore), a nutrient source, moisture, and the right temperature to proliferate. This explains why mold infestation is often found in damp, dark, hidden spaces; light and air circulation dry areas out, making them less hospitable for mold.

Molds gradually damage building materials and furnishings. If left unchecked, mold can eventually cause structural damage to a wood framed building, weakening floors and walls as it feeds on moist wooden structural members. If you suspect that mold has damaged building integrity, consult a structural engineer or other professional with the appropriate expertise.

Since mold requires water to grow, it is important to prevent excessive moisture in buildings. Some moisture problems in buildings have been linked to changes in building construction practices since the 1970s, which resulted in tightly sealed buildings with diminished ventilation, contributing to moisture vapor buildup. Other moisture problems may result from roof leaks, landscaping or gutters that direct water into or under a building, or unvented combustion appliance. Delayed or insufficient maintenance may contribute to moisture problems in buildings. Improper maintenance and design of building heating/ventilating/air-conditioning (HVAC) systems, such as insufficient cooling capacity for an air conditioning system, can result in elevated humidity levels in a building.

Health Effects of Mold

Currently, there are no federal standards or recommendations, (e.g., OSHA, NIOSH, EPA) for airborne concentrations of mold or mold spores. Scientific research on the relationship between mold exposures and health effects is ongoing. This section provides a brief overview, but does not describe all potential health effects related to mold exposure. For more detailed information, consult a health professional or your state or local health department.

There are many types of mold. Most typical indoor air exposures to mold do not present a risk of adverse health effects. Molds can cause adverse effects by producing allergens (substances that can cause allergic reactions). Potential health concerns are important reasons to prevent mold growth and to remediate existing problem areas.

The onset of allergic reactions to mold can be either immediate or delayed. Allergic responses include hay fever-type symptoms such as runny nose and red eyes.

Molds may cause localized skin or mucosal infections but, in general, do not cause systemic infections in humans, except for persons with impaired immunity, AIDS, uncontrolled diabetes, or those taking immune suppressive drugs. An important reference with guidelines for immuno-compromised individuals can be found at the Centers for Disease Control and Prevention (CDC) website.

Molds can also cause asthma attacks in some individuals who are allergic to mold. In addition, exposure to mold can irritate the eyes, skin, nose and throat in certain individuals. Symptoms other than allergic and irritant types are not commonly reported as a result of inhaling mold in the indoor environment.

Some specific species of mold produce mycotoxins under certain environmental conditions. Potential health effects from mycotoxins are the subject of ongoing scientific research and are beyond the scope of this document.

Eating, drinking, and using tobacco products and cosmetics where mold remediation is taking place should be avoided. This will prevent unnecessary contamination of food, beverage, cosmetics, and tobacco products by mold and other harmful substances within the work area.

MOLD RESISTANT CONSTRUCTION

For complete details on mold-resistant construction see MOLD RESISTANT CONSTRUCTION. OSHA's advice follows:

Moisture control is the key to mold control. When water leaks or spills occur indoors - act promptly. Any initial water infiltration should be stopped and cleaned promptly. A prompt response (within 24-48 hours) and thorough clean- up, drying, and/or removal of water-damaged materials will prevent or limit mold growth.

Mold prevention tips from OSHA include:

  • Repairing plumbing leaks and leaks in the building structure as soon as possible.
  • Looking for condensation and wet spots. Fix source(s) of moisture incursion problem(s) as soon as possible.
  • Preventing moisture from condensing by increasing surface temperature or reducing the moisture level in the air (humidity). To increase surface temperature, insulate or increase air circulation. To reduce the moisture level in the air, repair leaks, increase ventilation (if outside air is cold and dry), or dehumidify (if outdoor air is warm and humid).
  • Keeping HVAC drip pans clean, flowing properly, and unobstructed.
  • Performing regularly scheduled building/ HVAC inspections and maintenance, including filter changes.
  • Maintaining indoor relative humidity below 70% (25 - 60%, if possible).
  • Venting moisture-generating appliances, such as dryers, to the outside where possible.
  • Venting kitchens (cooking areas) and bathrooms according to local code requirements.
  • Cleaning and drying wet or damp spots as soon as possible, but no more than 48 hours after discovery.
  • Providing adequate drainage around buildings and sloping the ground away from building foundations. Follow all local building codes.
  • Pinpointing areas where leaks have occurred, identifying the causes, and taking preventive action to ensure that they do not reoccur.

Questions That May Assist in Determining Whether a Mold Problem Currently Exists

  • Are building materials or furnishings visibly moisture damaged?
  • Have building materials been wet more than 48 hours?
  • Are there existing moisture problems in the building?
  • Are building occupants reporting musty or moldy odors?
  • Are building occupants reporting health problems that they think are related to mold in the indoor environment?
  • Has the building been recently remodeled or has the building use changed?
  • Has routine maintenance been delayed or the maintenance plan been altered?

Always consider consulting a health professional to address any employee health concerns.

For complete details on mold-resistant construction see MOLD RESISTANT CONSTRUCTION.

Mold Remediation Plan

Remediation includes both the identification and correction of the conditions that permit mold growth, as well as the steps to safely and effectively remove mold damaged materials.

Before planning the remediation assess the extent of the mold or moisture problem and the type of damaged materials. If you choose to hire outside assistance to do the cleanup, make sure the contractor has experience with mold remediation. Check references and ask the contractor to follow the recommendations in EPA’s publication, “Mold Remediation in Schools and Commercial Buildings,” or other guidelines developed by professional or governmental organizations.

The remediation plan should include steps to permanently correct the water or moisture problem. The plan should cover the use of appropriate personal protective equipment (PPE). It also should include steps to carefully contain and remove moldy building materials in a manner that will prevent further contamination. Remediation plans may vary greatly depending on the size and complexity of the job, and may require revision if circumstances change or new facts are discovered.

If you suspect that the HVAC system is contaminated with mold, or if mold is present near the intake to the system, contact the National Air Duct Cleaners Association (NADCA), or consult EPA’s guide, “Should You Have the Air Ducts in Your Home Cleaned?” before taking further action. Do not run the HVAC system if you know or suspect that it is contaminated with mold, as it could spread contamination throughout the building. If the water or mold damage was caused by sewage or other contaminated water, consult a professional who has experience cleaning and repairing buildings damaged by contaminated water.

The remediation manager’s highest priority must be to protect the health and safety of the building occupants and remediators. Remediators should avoid exposing themselves and others to mold-laden dusts as they conduct their cleanup activities. Caution should be used to prevent mold and mold spores from being dispersed throughout the air where they can be inhaled by building occupants. In some cases, especially those involving large areas of contamination, the remediation plan may include temporary relocation of some or all of the building occupants.

When deciding if relocating occupants is necessary, consideration should be given to the size and type of mold growth, the type and extent of health effects reported by the occupants, the potential health risks that could be associated with the remediation activity, and the amount of disruption this activity is likely to cause. In addition, before deciding to relocate occupants, one should also evaluate the remediator’s ability to contain/minimize possible aerosolization of mold spores given their expertise and the physical parameters of the workspace. When possible, remediation activities should be scheduled during off hours when building occupants are less likely to be affected.

Remediators, particularly those with health related concerns, may wish to check with their physicians or other health-care professionals before working on mold remediation or investigating potentially moldy areas. If any individual has health concerns, doubts, or questions before beginning a remediation/cleanup project, he or she should consult a health professional.

Mold Remediation/Cleanup Methods

The purpose of mold remediation is to correct the moisture problem and to remove moldy and contaminated materials to prevent human exposure and further damage to building materials and furnishings. Porous materials that are wet and have mold growing on them may have to be discarded because molds can infiltrate porous substances and grow on or fill in empty spaces or crevices. This mold can be difficult or impossible to remove completely.

As a general rule, simply killing the mold, for example, with biocide is not enough. The mold must be removed, since the chemicals and proteins, which can cause a reaction in humans, are present even in dead mold.

A variety of cleanup methods are available for remediating damage to building materials and furnishings caused by moisture control problems and mold growth. The specific method or group of methods used will depend on the type of material affected. Some methods that may be used include the following:

Wet Vacuum Mold Remediation/Cleanup Methods

Wet vacuums are vacuum cleaners designed to collect water. They can be used to remove water from floors, carpets, and hard surfaces where water has accumulated. They should not be used to vacuum porous materials, such as gypsum board. Wet vacuums should be used only on wet materials, as spores may be exhausted into the indoor environment if insufficient liquid is present. The tanks, hoses, and attachments of these vacuums should be thoroughly cleaned and dried after use since mold and mold spores may adhere to equipment surfaces.

Damp Wipe Mold Remediation/Cleanup Methods

Mold can generally be removed from nonporous surfaces by wiping or scrubbing with water and detergent. It is important to dry these surfaces quickly and thoroughly to discourage further mold growth. Instructions for cleaning surfaces, as listed on product labels, should always be read and followed.

HEPA Vacuum Mold Remediation/Cleanup Methods

HEPA (High-Efficiency Particulate Air) vacuums are recommended for final cleanup of remediation areas after materials have been thoroughly dried and contaminated materials removed. HEPA vacuums also are recommended for cleanup of dust that may have settled on surfaces outside the remediation area. Care must be taken to assure that the filter is properly seated in the vacuum so that all the air passes through the filter. When changing the vacuum filter, remediators should wear respirators, appropriate personal protective clothing, gloves, and eye protection to prevent exposure to any captured mold and other contaminants. The filter and contents of the HEPA vacuum must be disposed of in impermeable bags or containers in such a way as to prevent release of the debris.

Disposal of Damaged Materials During Mold Cleanup Projects

Building materials and furnishings contaminated with mold growth that are not salvageable should be placed in sealed impermeable bags or closed containers while in the remediation area. These materials can usually be discarded as ordinary construction waste. It is important to package mold-contaminated materials in this fashion to minimize the dispersion of mold spores. Large items with heavy mold growth should be covered with polyethylene sheeting and sealed with duct tape before being removed from the remediation area. Some jobs may require the use of dust-tight chutes to move large quantities of debris to a dumpster strategically placed outside a window in the remediation area.

Use of Biocides During Mold Cleanup Projects

The use of a biocide, such as chlorine bleach, is not recommended as a routine practice during mold remediation, although there may be instances where professional judgment may indicate its use (for example, when immuno-compromised individuals are present). In most cases, it is not possible or desirable to sterilize an area, as a background level of mold spores comparable to the level in outside air will persist. However, the spores in the ambient air will not cause further problems if the moisture level in the building has been corrected.

Biocides are toxic to animals and humans, as well as to mold. If you choose to use disinfectants or biocides, always ventilate the area, using outside air if possible, and exhaust the air to the outdoors. When using fans, take care not to extend the zone of contamination by distributing mold spores to a previously unaffected area. Never mix chlorine bleach solution with other cleaning solutions or detergents that contain ammonia because this may produce highly toxic vapors and create a hazard to workers.

Some biocides are considered pesticides, and some states require that only registered pesticide applicators apply these products in schools, commercial buildings, and homes. Make sure anyone applying a biocide is properly licensed where required.

Fungicides are commonly applied to outdoor plants, soil, and grains as a powder or spray. Examples of fungicides include hexachlorobenzene, organomercurials, pentachlorophenol, phthalimides, and dithiocarbamates.

Do not use fungicides developed for outdoor use in any indoor application, as they can be extremely toxic to animals and humans in an enclosed environment.

When you use biocides as a disinfectant or a pesticide, or as a fungicide, you should use appropriate PPE, including respirators. Always, read and follow product label precautions. It is a violation of Federal (EPA) law to use a biocide in any manner inconsistent with its label direction.

OSHA Mold Remediation Guidelines

This section presents remediation guidelines for building materials that have or are likely to have mold growth. The guidelines are designed to protect the health of cleanup personnel and other workers during remediation. These guidelines are based on the size of the area impacted by mold contamination. Please note that these are guidelines; some professionals may prefer other remediation methods, and certain circumstances may require different approaches or variations on the approaches described below. If possible, remediation activities should be scheduled during off-hours when building occupants are less likely to be affected.

Although the level of personal protection suggested in these guidelines is based on the total surface area contaminated and the potential for remediator or occupant exposure, professional judgment always should play a part in remediation decisions.

These remediation guidelines are based on the size of the affected area to make it easier for remediators to select appropriate techniques, not on the basis of research showing there is a specific method appropriate at a certain number of square feet. The guidelines have been designed to help construct a remediation plan. The remediation manager should rely on professional judgment and experience to adapt the guidelines to particular situations. When in doubt, caution is advised. Consult an experienced mold remediator for more information.

Level I: Small Isolated Areas of Mold

(10 sq. ft or less) - e.g., ceiling tiles, small areas on walls.

  • Remediation can be conducted by the regular building maintenance staff as long as they are trained on proper clean-up methods, personal protection, and potential health hazards. This training can be performed as part of a program to comply with the requirements of the OSHA Hazard Communication Standard (29 CFR 1910.1200).
  • Respiratory protection (e.g., N-95 disposable respirator) is recommended. Respirators must be used in accordance with the OSHA respiratory protection standard (29 CFR 1910.134). Gloves and eye protection should be worn.
  • The work area should be unoccupied. Removing people from spaces adjacent to the work area is not necessary, but is recommended for infants (less than 12 months old), persons recovering from recent surgery, immune-suppressed people, or people with chronic inflammatory lung diseases (e.g., asthma, hypersensitivity pneumonitis, and severe allergies).
  • Containment of the work area is not necessary. Dust suppression methods, such as misting (not soaking) surfaces prior to remediation, are recommended.
  • Contaminated materials that cannot be cleaned should be removed from the building in a sealed impermeable plastic bag. These materials may be disposed of as ordinary waste.
  • The work area and areas used by remediation workers for egress should be cleaned with a damp cloth or mop and a detergent solution.
  • All areas should be left dry and visibly free from contamination and debris.

Level II: Mid-Sized Isolated Areas of Mold

(10-30 sq. ft.) – e.g., individual wallboard panels.

  • Remediation can be conducted by the regular building maintenance staff. Such persons should receive training on proper clean-up methods, personal protection, and potential health hazards. This training can be performed as part of a program to comply with the requirements of the OSHA Hazard Communication Standard (29 CFR 1910.1200).
  • Respiratory protection (e.g., N-95 disposable respirator) is recommended. Respirators must be used in accordance with the OSHA respiratory protection standard (29 CFR 1910.134). Gloves and eye protection should be worn.
  • The work area should be unoccupied. Removing people from spaces adjacent to the work area is not necessary, but is recommended for infants (less than 12 months old), persons recovering from recent surgery, immune-suppressed people, or people with chronic inflammatory lung diseases (e.g., asthma, hypersensitivity pneumonitis, and severe allergies).
  • Surfaces in the work area that could become contaminated should be covered with a secured plastic sheet(s) before remediation to contain dust/debris and prevent further contamination
  • Dust suppression methods, such as misting (not soaking) surfaces prior to remediation, are recommended.
  • Contaminated materials that cannot be cleaned should be removed from the building in a sealed impermeable plastic bag. These materials may be disposed of as ordinary waste.
  • The work area and areas used by remediation workers for egress should be HEPA vacuumed and cleaned with a damp cloth or mop and a detergent solution.
  • All areas should be left dry and visibly free from contamination and debris.

Level III: Large Isolated Areas of Mold

(30 –100 square feet) – e.g., several wallboard panels.

Industrial hygienists or other environmental health and safety professionals with experience performing microbial investigations and/or mold remediation should be consulted prior to remediation activities to provide oversight for the project.

The following procedures may be implemented depending upon the severity of the contamination:

  • It is recommended that personnel be trained in the handling of hazardous materials and equipped with respiratory protection (e.g., N-95 disposable respirator). Respirators must be used in accordance with the OSHA respiratory protection standard (29 CFR 1910.134). Gloves and eye protection should be worn.
  • Surfaces in the work area and areas directly adjacent that could become decontaminated should be covered with a secured plastic sheet(s) before remediation to contain dust/ debris and prevent further contamination.
  • Seal ventilation ducts/grills in the work area and areas directly adjacent with plastic sheeting.
  • The work area and areas directly adjacent should be unoccupied. Removing people from spaces near the work area is recommended for infants, persons having undergone recent surgery, immunesuppressed people, or people with chronic inflammatory lung diseases. (e.g., asthma, hypersensitivity pneumonitis, and severe allergies).
  • Dust suppression methods, such as misting (not soaking) surfaces prior to mediation, are recommended.
  • Contaminated materials that cannot be cleaned should be removed from the building in sealed impermeable plastic bags. These materials may be disposed of as ordinary waste.
  • The work area and surrounding areas should be HEPA vacuumed and cleaned with a damp cloth or mop and a detergent solution.
  • All areas should be left dry and visibly free from contamination and debris.

Note: If abatement procedures are expected to generate a lot of dust (e.g., abrasive cleaning of contaminated surfaces, demolition of plaster walls) or the visible concentration of the mold is heavy (blanket coverage as opposed to patchy), it is recommended that the remediation procedures for Level IV be followed.

Level IV: Extensive Mold Contamination in a Building

(Greater than 100 contiguous square feet in an area).

Industrial hygienists or other environmental health and safety professionals with experience performing microbial investigations and/or mold remediation should be consulted prior to remediation activities to provide oversight for the project.

The following procedures may be implemented depending upon the severity of the contamination:

  • Personnel trained in the handling of hazardous materials and equipped with:
    • Full face piece respirators with HEPA cartridges;
    • Disposable protective clothing covering entire body including both head and shoes; and
    • Gloves.
  • Containment of the affected area:
    • Complete isolation of work area from occupied spaces using plastic sheeting sealed with duct tape (including ventilation ducts/grills, fixtures, and other openings);
    • The use of an exhaust fan with a HEPA filter to generate negative pressurization; and
    • Airlocks and decontamination room.
  • If contaminant practices effectively prevent mold from migrating from affected areas, it may not be necessary to remove people from surrounding work areas. However, removal is still recommended for infants, persons having undergone recent surgery, immune- suppressed people, or people with chronic inflammatory lung diseases. (e.g., asthma, hypersensitivity pneumonitis, and severe allergies).
  • Contaminated materials that cannot be cleaned should be removed from the building in sealed impermeable plastic bags. The outside of the bags should be cleaned with a damp cloth and a detergent solution or HEPA vacuumed in the decontamination chamber prior to their transport to uncontaminated areas of the building. These materials may be disposed of as ordinary waste.
  • The contained area and decontamination room should be HEPA vacuumed and cleaned with a damp cloth or mopped with a detergent solution and be visibly clean prior to the removal of isolation barriers.

Personal Protective Equipment (PPE) for Mold Remediation

Any remediation work that disturbs mold and causes mold spores to become airborne increases the degree of respiratory exposure. Actions that tend to disperse mold include: breaking apart moldy porous materials such as wallboard; destructive invasive procedures to examine or remediate mold growth in a wall cavity; removal of contaminated wallpaper by stripping or peeling; using fans to dry items or ventilate areas.

The primary function of personal protective equipment is to prevent the inhalation and ingestion of mold and mold spores and to avoid mold contact with the skin or eyes. The following sections discuss the various types of PPE that may be used during remediation activities.

Skin and Eye Protection for Mold Remediation Workers

Gloves protect the skin from contact with mold, as well as from potentially irritating cleaning solutions. Long gloves that extend to the middle of the forearm are recommended. The glove material should be selected based on the type of substance/ chemical being handled. If you are using a biocide such as chlorine bleach, or a strong cleaning solution, you should select gloves made from natural rubber, neoprene, nitrile, polyurethane, or PVC. If you are using a mild detergent or plain water, ordinary household rubber gloves may be used.

To protect your eyes, use properly fitted goggles or a full face piece respirator. Goggles must be designed to prevent the entry of dust and small particles. Safety glasses or goggles with open vent holes are not appropriate in mold remediation.

Respiratory Protection for Mold Remediation Workers

Respirators protect cleanup workers from inhaling airborne mold, contaminated dust, and other particulates that are released during the remediation process. Either a half mask or full face piece air-purifying respirator can be used. A full face piece respirator provides both respiratory and eye protection. Please refer to the discussion of the different levels of remediation to ascertain the type of respiratory protection recommended. Respirators used to provide protection from mold and mold spores must be certified by the National Institute for Occupational Safety and Health (NIOSH). More protective respirators may have to be selected and used if toxic contaminants such as asbestos or lead are encountered during remediation.

As specified by OSHA in 29 CFR 1910.134 individuals who use respirators must be properly trained, have medical clearance, and be properly fit tested before they begin using a respirator. In addition, use of respirators requires the employer to develop and implement a written respiratory protection program, with worksite-specific procedures and elements.

Protective Clothing for Mold Remediation Workers

While conducting building inspections and remediation work, individuals may encounter hazardous biological agents as well as chemical and physical hazards. Consequently, appropriate personal protective clothing (i.e., reusable or disposable) is recommended to minimize cross-contamination between work areas and clean areas, to prevent the transfer and spread of mold and other contaminants to street clothing, and to eliminate skin contact with mold and potential chemical exposures.

Disposable PPE should be discarded after it is used. They should be placed into impermeable bags, and usually can be discarded as ordinary construction waste. Appropriate precautions and protective equipment for biocide applicators should be selected based on the product manufacturer’s warnings and recommendations (e.g., goggles or face shield, aprons or other protective clothing, gloves, and respiratory protection).

Sampling for Mold in the Workplace

Is it necessary to sample for mold? In most cases, if visible mold growth is present, sampling is unnecessary. Air sampling for mold may not be part of a routine assessment because decisions about appropriate remediation strategies often can be made on the basis of a visual inspection.

Your first step should be to inspect for any evidence of water damage and visible mold growth. Testing for mold is expensive, and there should be a clear reason for doing so. In many cases, it is not economically practical or useful to test for mold growth on surfaces or for airborne spores in the building. In addition, there are no standards for “acceptable” levels of mold in buildings, and the lack of a definitive correlation between exposure levels and health effects makes interpreting the data difficult, if not impossible.

Testing is usually done to compare the levels and types of mold spores found inside the building with those found outside of the building or for comparison with another location in the building. In addition, air sampling may provide tangible evidence supporting a hypothesis that investigators have formulated.

For example, air sampling may show a higher concentration of the same species of mold when the HVAC is operating than when it has been turned off. This finding may convince the investigators that the mold is growing within, and being disseminated by, the HVAC system. Conversely, negative results may persuade investigators to abandon this hypothesis and to consider other sources of mold growth or dissemination. If you know you have a mold problem, it is more important to spend time and resources removing the mold and solving the moisture problem that causes the moldy conditions than to undertake extensive testing for the type and quantity of mold.

If you are in doubt about sampling, consult an industrial hygienist or other environmental health or safety professional with experience in microbial investigations to help you decide if sampling for mold is necessary or useful, and to identify persons who can conduct any necessary sampling. Due to the wide difference in individual susceptibility to mold contamination, sampling results sampling may have limited application. However, sampling results can be used as a guide to determine the extent of an infestation and the effectiveness of the cleanup. Their interpretation is best left to the industrial hygienist or other environmental health or safety professional.

Sampling for mold should be conducted by professionals with specific experience in designing mold-sampling protocols, sampling methods for microbial contaminants, and interpretation of results. For additional information on air sampling, refer to the American Conference of Governmental Industrial Hygienists’ document, “Bioaerosols: Assessment and Control.” In addition, sampling and analysis should follow any other methods recommended by either OSHA, NIOSH, EPA, the American Industrial Hygiene Association, or other recognized professional guidelines. Types of samples can include: air samples, surface samples, bulk samples, and water samples from condensate drain pans or cooling towers.

Microscopic identification of the spores/ colonies requires considerable expertise. These services are not routinely available from commercial laboratories. Documented quality control in the laboratories used for analysis of the bulk, surface, and other air samples is necessary. The American Industrial Hygiene Association offers accreditation to microbial laboratories (Environmental Microbiology Laboratory Accreditation Program (EMLAP)). Accredited laboratories must participate in quarterly proficiency testing (Environmental Microbiology Proficiency Analytical Testing Program (EMPAT)).

Mold Remediation Equipment

There are various types of equipment useful in mold assessment and remediation. Some of the more common items include:

Moisture Meters for Mold Remediation Assessment

Moisture meters measure/monitor moisture levels in building materials, and may be helpful for measuring the moisture content in a variety of building materials following water damage. They also can be used to monitor the progress of drying damaged materials. These direct reading devices have a thin probe that is inserted into the material to be tested or pressed directly against the surface of the material. Moisture meters can be used on materials such as carpet, wallboard, wood, brick, and concrete.

Humidity Gauges or Meters for Mold Remediation Assessment

Humidity meters can be used to monitor indoor humidity. Inexpensive (less than $50) models that monitor both temperature and humidity are available.

Humidistat for Mold Remediation Assessment

A humidistat is a control device that can be connected to an HVAC system and adjusted so that if the humidity level rises above a set point, the HVAC system will automatically turn on and reduce the humidity below the established point.

Boroscope for Mold Remediation Assessment

A boroscope is a hand-held tool that allows users to see potential mold problems inside walls, ceiling plenums, crawl spaces, and other tight areas. It consists of a video camera on the end of a flexible “snake.” No major drilling or cutting of dry wall is required.

HVAC System Filter for Mold Remediation

High-quality filters must be used in a HVAC system during remediation because conventional HVAC filters are typically not effective in filtering particles the size of mold spores. Consult an engineer for the appropriate filter efficiency for your specific HVAC system, and consider upgrading your filters if necessary. A filter with a minimum efficiency of 50 to 60% or a rating of MERV 8, as determined by Test Standard 52.2 of the American Society of Heating, Refrigerating and Air-Conditioning Engineers, may be appropriate.

Remember to change filters as appropriate, especially following any remediation activities. Remove filters in a manner that minimizes the reentry of mold and other toxic substances into the workplace. Under certain circumstances, it may be necessary to wear appropriate PPE while performing this task.

How Do You Know When You Have Finished Remediation/Cleanup?

  • You must have identified and completely corrected the source of the water or moisture problem.
  • Mold removal should be complete. Visible mold, mold-damaged materials, and moldy odors should no longer be present.
  • Sampling, if conducted, should show that the level and types of mold and mold spores inside the building are similar to those found outside.
  • You should revisit the site(s) after remediation, and it should show no signs of moldy or musty odors, water damage, or mold growth.

Conclusion

fter correcting water or moisture infiltration, the prompt removal of contaminated material and structural repair is the primary response to mold contamination in buildings. In all situations, the underlying cause of water accumulation must be rectified or the mold growth will reoccur. Emphasis should be placed on preventing contamination through proper building and HVAC system maintenance and prompt repair of water damaged areas.

Effective communication with building occupants is an essential component of all large-scale remediation efforts. The building owner, management, and/or employer should notify occupants in the affected area(s) of the presence of mold. Notification should include a description of the remedial measures to be taken and a timetable for completion.

Group meetings held before and after remediation with full disclosure of plans and results can be an effective communication mechanism. Individuals with persistent health problems that appear to be related to mold exposure should see their physicians for a referral to practitioners who are trained in occupational/environmental medicine or related specialties and are knowledgeable about these types of exposures.

Mold References

American Conference of Governmental Industrial Hygienists 1999. Bioaerosols Assessment and Control
http://www.acgih.org

National Apartment Association
http://www.naahq.org

National Institute for Occupational Safety and Health (NIOSH)

National Multi-Housing Council
http://www.nmhc.org

The Building Owners and Managers Association International (BOMA)
http://www.boma.org

New York City Department of Health & Mental Hygiene Bureau of Environmental & Occupational Disease Epidemiology 2002. Guidelines on Assessment and Remediation of Fungi in Indoor Environments

United States Environmental Protection Agency, Office of Air and Radiation, Indoor Environments Division 2001. Mold Remediation in Schools and Commercial Buildings. EPA 402-K-01-001

Mold Resources List

Business owners who are concerned about the cost of professional help can contact the OSHA Consultation Project Office in their state for free consultation service. Priority is given to businesses with fewer than 250 employees at a worksite, with further consideration given to the severity of the worksite problem. The Consultation Program can help the employer evaluate and prevent hazardous conditions in the workplace that can cause injuries and illnesses, including mold problems.

The following list of resources includes information developed and maintained by public and private organizations. However, OSHA does not control this information and cannot guarantee the accuracy, relevance, timeliness, or completeness of this outside information. Further, the inclusion of these resources is not intended to endorse any views expressed, or products or services offered, by the author of the reference or the organization operating the service identified by the reference.

An Office Building Occupant’s Guide to IAQ

Biological Contaminants

Building Air Quality Action Plan (For Commercial Buildings)

Floods/Flooding

Indoor Air Quality (IAQ) Home Page

IAQ in Large Buildings/Commercial Buildings

IAQ in Schools

Mold Resources

Mold Remediation in Schools and Commercial Buildings

U.S. EPA IAQ Information Clearinghouse (IAQINFO)
Phone: (800)438-4318 or (703)356-4020
Fax: (703)356-5386
Email: iaqinfo@aol.com
Indoor air related documents, answers to Indoor Air Quality (IAQ) questions, maintains listing of State IAQ contacts, and regional EPA Contacts.

Air Conditioning Contractors of America (ACCA)
(703)575-4477
http://www.acca.org
Information on indoor comfort products and services.

American College of Occupational and Environmental Medicine (ACOEM)
(847)818-1800
http://eserver.acoem.org/physicianlocator/default.cfm
Referrals to physicians who have experience with environmental exposures.

American Conference of Governmental Industrial Hygienists, Inc. (ACGIH)
(513)742-2020
http://www.acgih.org
Occupational and environmental health and safety information.

American Industrial Hygiene Association (AIHA)
(703)849-8888
http://www.aiha.org
Information on industrial hygiene and indoor air quality issues including mold hazards and legal issues.

American Society of Heating, Refrigerating and Air Conditioning Engineers, Inc. (ASHRAE)
(800)527-4723
http://www.ashrae.org
Information on engineering issues and indoor air quality.

Association of Occupational and Environmental Clinics (AOEC)
(202)347-4976
http://www.aoec.org
Referrals to clinics with physicians, who have experience with environmental exposures, include exposure to mold; maintains a database of occupational and environmental cases.

Association of Specialists in Cleaning and Restoration (ASCR)
(800)272-7012 or (410)729-3603
http://www.ascr.org/institutes
Carpet and Upholstery Cleaning Institute, Mechancial Systems Hygiene Institute, National Institute of Disaster Restoration, National Institute Rug Cleaning, Water Loss Institute referrals to professionals.

American Academy of Allergy, Asthma & Immunology (AAAAI)
(800)822-2762
http://www.aaaai.org
Physician referral directory, information on allergies and asthma.

Asthma and Allergy Foundation of American (AAFA)
(800) 7ASTHMA (800)727-8462)
http://www.aafa.org
Information on allergies and asthma.

American Lung Association (ALA)
(800) LUNGUSA (800)586-4872)
http://www.lungusa.org
Information on allergies and asthma.

Allergy and Asthma Network Mothers of Asthmatics (AANMA)
(800)878-4403 or (703)641-9595)
http://www.aanma.org
Information on allergies and asthma.

National Institute of Allergy and Infectious Diseases (NIAID)
(301)496-5717
Information on allergies and asthma.

National Jewish Medical and Research Center
(800) 222LUNG (800)222-5864)
http://www.njc.org
Information on allergies and asthma.

Carpet and Rug Institute (CRI)
(800) 882-8846
http://www.carpet-rug.com
Carpet maintenance, restoration guidelines for water-damaged carpet, other carpet-related issues.

Centers for Disease Control and Prevention (CDC)
(800)311-3435
Information on health-related topics including asthma molds in the environment, and occupational health. CDC is recognized as the lead federal agency for protecting the health and safety of the American people at home and abroad. It serves as the national focus for developing and applying disease prevention and control, environmental health, and health promotion and education activities.

Floods/Flooding
Federal Emergency Management Agency (FEMA)
(800)480-2520
Publications on floods, flood proofing, etc.

University of Minnesota, Department of Environmental Health and Safety
(612)626-5804
http://www.dehs.umn.edu/iaq/flood.html
Managing water infiltration into buildings.

Indoor Environmental Remediation Board (IERB)
(215)387-4097
http://www.ierb.org
Information on best practices in building remediation.

Institute of Inspection, Cleaning and Restoration Certification (IICRC)
(360)693-5675
http://www.iicrc.org
Information on and standards for the inspection, cleaning, and restoration industry.

International Sanitary Supply Association (ISSA)
(800)225-4772
http://www.issa.com
Education and training on cleaning and maintenance.

MidAtlantic Environmental Hygiene Resource Center (MEHRC)
(215)387-4096
http://www.mehrc.org
Indoor environmental quality training center giving courses in building moisture and biocontamination, and managing and operating facilities for good IAQ. Extensive courses given in IAQ.

National Air Duct Cleaners Association (NADCA)
(202)737-2926
http://www.nadca.com
Duct cleaning information.

National Institute of Building Sciences (NIBS)
(202)289-7800
http://www.nibs.org
Information on building regulations, science, and technology.

National Institute for Occupational Safety and Health (NIOSH)
(800) 35NIOSH (800)356-4674)
Health and safety information with a workplace orientation.

National Pesticide Information Center (NPIC)
(800)858-7378
http://npic.orst.edu/
Information on pesticides/antimicrobial chemicals, including safety and disposal information.

New York City Department of Health, Bureau of Environmental and Occupational Disease Epidemiology, Guidelines on Assessment and Remediation of Fungi in Indoor Environments
(212)788-4290

Occupational Safety and Health Administration (OSHA)
(800)321-OSHA (800)321-6742)
Information on worker safety and health, compliance assistance, laws and regulations, cooperative programs, state programs, statistics, and newsroom.

Sheet Metal and Air Conditioning Contractors’ National Association (SMACNA)
(703)803-2980
http://www.smacna.org
Technical information on topics such as air conditioning and air ducts.

Occupational Safety & Health Administration
200 Constitution Avenue, NW
Washington, DC 20210

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

MOLD LEVELS IN BUILDINGS
MOLD CONTAMINATION LEVELS
  MOLD CULTURES
  AIRBORNE SPORES
  CONTAMINATION LEVELS
TOXICITY VARIATION
  PARTICLE TOXICITY
  VIABLE vs NON-VIABLE
GOVERNMENT STANDARDS
MOLD STANDARDS - WORLD WIDE
  Australian Mould Guidelines
  California Mold Disclosure Law
  Canadian Mould Guidelines
  Canadian National Toxic Mold Centre
  New York City Mold Guidelines
  OSHA Guide to Workplace Mold
  World Health Organization Mold Bulletin
MYCOTOXIN EFFECTS
SPECIFIC MOLDS
also see ACCEPTABLE MOLD LEVEL
MOLD EXPOSURE RISK LEVELS
  L1: Very-Low Mold Risk
  L2: Low Mold Risk
  L3: High Mold Risk
  L4: Contaminated

  • OSHA: Brief Guide to Mold in the Workplace, original citation: http://www.osha.gov/dts/shib/shib101003.html

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Environmental Health & Investigation Bibliography - our technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Adkins and Adkins Dictionary of Roman Religion discusses Robigus, the Roman god of crop protection and the legendary progenitor of wheat rust fungus.
  • Kansas State University, department of plant pathology, extension plant pathology web page on wheat rust fungus: see http://www.oznet.ksu.edu/path-ext/factSheets/Wheat/Wheat%20Leaf%20Rust.asp
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • US EPA - Mold Remediation in Schools and Commercial Building US EPA
  • US EPA - Una Breva Guia a Moho - Hongo - en Espanol

Allergies, Allergens, Allergy Testing in Buildings - References & Products

  • Air Conditioning System Blower Fans & Filters Cascading for Optimum Indoor Air Quality
  • Allergen Tests in Buildings advice about how to test, what to look for, in evaluating the level of dog, cat, or other animal allergens in a building
  • "IgG Food Allergy Testing by ELISA/EIA, What do they really tell us?" Sheryl B. Miller, MT (ASCP), PhD, Clinical Laboratory Director, Bastyr University Natural Health Clinic - ELISA testing accuracy: Here is an example of Miller's critique of ELISA http://www.betterhealthusa.com/public/282.cfm - Townsend Letter for Doctors and Patients
    The critique included in that article raises compelling questions about IgG testing assays, which prompts our interest in actually screening for the presence of high levels of particles that could carry allergens - dog dander or cat dander in the case at hand.
    http://www.tldp.com/issue/174/IgG%20Food%20Allergy.html contains similar criticism in another venue but interestingly by the same author, Sheryl Miller. Sheryl Miller, MT (ASCP), PhD, is an Immunologist and Associate Professor of Basic and Medical Sciences at Bastyr University in Bothell, Washington. She is also the Laboratory Director of the Bastyr Natural Health Clinic Laboratory.
  • Allergens: Testing for the level of exposure to animal allergens is discussed at http://www.animalhealthchannel.com/animalallergy/diagnosis.shtml (lab animal exposure study is interesting because it involves a higher exposure level in some cases
  • Allergens: WebMD discusses allergy tests for humans at webmd.com/allergies/allergy-tests
  • Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
  • Atlas of Mold Related Illness Symptoms & Complaints - long list of both documented, studied mold related illness, and complaints ascribed to mold contamination or allergens in buildings
  • Cat Dander: how to inspect and test a building for past or current presence of cats, cat hair, cat dander, and cat allergens
  • Clinical Atlas of Mold Toxicity - An Online Description of Toxic, Pathogenic, Allergenic Fungi, Fungal Diseases
  • Fiberglass Insulation Contains Mold© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?
  • Mold Action Guide detailed guide on finding, removing, and preventing indoor mold contamination
  • Odors, Odor Detection, Smells, & Gases how to find and identify sources of noxious or toxic odors and gases
  • Other environmental risks, Our much longer list: Asbestos, carbon monoxide, electromagnetic fields, etc.
  • Ozone: The Use of Ozone Indoors for Control of Odors and Mold Removal in Buildings: A Summary of Hazards and False Claims.
  • Pollen Allergens: identification, plant pollen and indoor air quality
  • Products to Reduce Mold & Allergy Problems to reduce indoor mold or allergen levels: air cleaners, air purifiers, dust mite covers, vacuum cleaners, crawl space vents
  • Recognizing Allergens: What various indoor allergens look like - identification photos to help identify pollen, dust mites, animal dander, toxic or allergenic mold - Common Mold and other Allergens, Irritants, Remedies & Advice
  • Rodent control issues, including dander, fecal, and urine contamination of Buildings and Building insulation are discussed at our
  • Sewage and Septic backup contamination in Buildings: inspection, testing, remediation, & references to expert sources
  • Action Guide: What to do about mold, mildew, and other indoor allergens
  • ...

Mold Contamination Testing, Cleanup, Prevention: references & products

  • GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminantsThe Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
  • Aerobiology, Building Science, Microscopy, & Laboratory References, an extensive technical bibliography
  • Allergens: what they look like in buildings
  • Associations: Sick House, Sick Building, SBS - Air Quality, Government, Private Associations and Information Resources
  • Atlas of Clinical Fungi, 2nd Ed., GS deHoog, J Guarro, J Gene, & MJ Figueras, Centraalbureau voor Schimmelcultures, Universitat Rovira I Virgili, 2000, ISBN 90-70351-43-9 (you can buy this book at Amazon)
  • Atlas of Mold Related Illness: Index of Symptoms and health, physical, neurological, psychological, and other complaint which people suspect may be mold or building-related.
  • Atlas of Indoor Mold, Online Clinical Mold Atlas, Toxins, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • Black Mold that is Harmless Photos of recognizable, usually harmless black mold on wood, bluestain, ceratocystis, ophistoma
  • Building Floods: quick steps after a building flood or plumbing leak can prevent costly mold contamination
  • Classes of Mold: what types of cosmetic, allergenic, or toxic mold are a problem? Can mold be cleaned-up successfully?
  • Clinical Mold References - Detailed bibliography of mold reference texts
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • "Disease Prevention Program for Certain Vegetable Crops," David B. Langston, Jr., Extension Plant Pathologist - Vegetables, University of Georgia (PDF document) original source: www.reeis.usda.gov/web/crisprojectpages/209797.html
  • "Disease Prevention in Home Vegetable Gardens," Patricia Donald, Department of Plant Microbiology and Pathology, Lewis Jett
    Department of Horticulture, University of Missouri Extension - extension.missouri.edu/publications/DisplayPub.aspx?P=G6202
  • "Management of Powdery Mildew, Leveillula taurica, in Greenhouse Peppers," Ministry of Agriculture and Lands, British Columbia - Original source: www.agf.gov.bc.ca/cropprot/peppermildew.htm
  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Fiberglass: Mold in Fiberglass Insulation© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation - DJF
  • Fifth Kingdom, Bryce Kendrick, ISBN13: 9781585100224, is available from the InspectAPedia online bookstore - we recommend the CD-ROM version of this book. This 3rd/edition is a compact but comprehensive encyclopedia of all things mycological. Every aspect of the fungi, from aflatoxin to zppspores, with an accessible blend of verve and wit. The 24 chapters are filled with up-to-date information of classification, yeast, lichens, spore dispersal, allergies, ecology, genetics, plant pathology, predatory fungi, biological control, mutualistic symbioses with animals and plants, fungi as food, food spoilage and mycotoxins.
  • Fungi, Identifying Filamentous, A Clinical Laboratory Handbook, Guy St-Germain, Richard Summerbell, Star Publishing, 1996, ISBN 0-89863-177-7 (English) (buy at Amazon)
  • Looking for Mold Procedure: what mold is often found where in buildings - simple technical presentation
  • Meruliporia: the house eating fungus or "poria"
  • Mold Action Guide: Step-by-Step Instructions, What to do about mold, mildew, and other indoor allergens
  • MOLD APPEARANCE - WHAT MOLD LOOKS LIKE Photos of what mold looks like in buildings
  • MOLD APPEARANCE - STUFF THAT IS NOT MOLD Photos of NOT-mold material that is sometimes mistaken for mold
  • MOLD ATLAS & PARTICLES INDEX, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • MOLD BY MICROSCOPE Mold under the microscope - photo identification of the most common indoor molds found in buildings
  • Mold FAQs Answers to Most Questions about Indoor Mold, Mold Related Illness, Mold Cleanup, Mold Prevention
  • US EPA: Mold Remediation in Schools and Commercial Building US EPA
  • Mold spores in the Home - a Photo ID Library for detection and identification of mold allergens
  • Mold Test Kits - How to Collect and Send Your Own Mold Sample to our mold testing lab or to any mold lab you wish
  • Most Common Indoor Molds Found in Buildings, A Table of
  • Mycology, Fundamentals of Diagnostic, Fran Fisher, Norma B. Cook, W.B. Saunders Co. 1998, ISBN 0-7216-5006-6 (buy this book at Amazon)
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Rot concerns in buildings-some building mold such as Meruliporia incrassata "Poria" risks serious rot and hidden structural damage
  • US EPA: Una Breva Guia a Moho - Hongo - en Espanol

OTHER IAQ ISSUES: How To Find and Address Other Indoor Air or Indoor Environment Contaminants Besides Mold

Mold or allergens may not be the only or even the main indoor environmental contaminant. Don't let media attention to mold cause so much enviro-scare fear that other, possibly more urgent hazards go un-addressed.

  • Fiberglass building insulation and HVAC duct work insulation hazards
  • Sewage and Septic backup contamination in buildings: inspection, testing, remediation, & references to expert sources
  • Other environmental risks: Asbestos, carbon monoxide, electromagnetic fields, environmental illness, fiberglass, MCS - multiple chemical sensitivity, toxic gases, etc
  • Indoor Gas Sampling Plan for Residential Buildings lists a number of toxic indoor gases which we test for, depending on the building complaint and building conditions
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Pet control - if you can't say goodbye to your bird, cat, dog, guinea pig, hamster, tropical fish, then limit the areas they occupy and limit the airflow from that area to sleeping or other areas of the building, use allergenic bedding, eliminate wall-to-wall carpeting, improve housecleaning including use of a HEPA-rated vacuum cleaner. For more details see our article Dog, Cat, and Other Animal Dander - Information for Asthmatics and Indoor Air Quality
  • Rodents, Mice, Squirrel Control - I find high levels of mouse and rodent dander, fecal dust, and urine-contaminated dust in some buildings, and high levels of these materials in building insulation in those locations. If you have a mouse problem, particularly if mice and their waste (fecals or urine) are contaminating the building HVAC or building insulation, may need both steps to clean up or remove infected materials and steps to stop an ongoing rodent problem. If squirrels are a problem, the cleanup needs to include closing off entry openings into the building. Get some help from a licensed pest control expert.