OZONE as a "CURE" for TOXIC INDOOR MOLD or ODORS
WHAT IS OZONE- O3
OZONE AIR PURIFIER WARNINGS
OZONE HAZARDS
STANDARDS FOR OZONE EXPOSURE
TESTING FOR OZONE
OZONE TOXICITY
OZONE ODORS, MOLD, REFS

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



References & Citations On Ozone Gas Hazards, Ozone Generators & Control of Odors and Mold Removal in Buildings
InspectAPedia®  -    

  • Technical references, citations, studies on Ozone gas
  • The effects of using ozone in buildings to "purify air" or to "kill mold"
  • The toxicity of ozone gas and ozone gas exposure limits
  • The hazards of ozone generators in buildings
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

Ozone is widely promoted by ozone generating equipment companies and cleaning services for use in indoor building environments to deodorize, disinfect, "kill" mold, and for "general health". Ozone generators are also promoted for use to reduce the level of airborne particles, pollen, animal dander, and allergens, ostensibly to improve indoor air quality for asthmatics and people with allergies.

While there are some important uses of ozone (such as for medical disinfection under controlled conditions), in general this is an idea which ranges from bad to dangerous in the home.

This article explains the effects of using ozone in buildings for these purposes and warns consumers about misapplication of and health risks from ozone in buildings.

Because at least some of these claims are based on marketing desire, not good science, and because ozone exposure can be both dangerous and ineffective indoors, I have collected some information and references on this topic. © Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

OZONE as a "CURE" for TOXIC INDOOR MOLD
WHAT IS OZONE- O3
OZONE AIR PURIFIER WARNINGS
OZONE HAZARDS
STANDARDS FOR OZONE EXPOSURE
TESTING FOR OZONE
OZONE TOXICITY
OZONE ODORS, MOLD, REFS

OZONE ODORS, MOLD, REFS: References on Ozone, Odors, and Mold

[1] Ozone exposure limits: NIOSH REL: C 0.1 ppm (0.2 mg/m3); OSHA PEL: TWA 0.1 ppm (0.2 mg/m3)

[2] Ozone and other contaminants discussed, New York State Department of Environmental Conservation,

http://www.dec.state.ny.us/website/dardata/airmon/parametertextpage1.htm

[3] Indoor air, http://www.health.state.ny.us/nysdoh/indoor/indoor.htm New York State Department of Health

[4]Environmental Toxins, Yale New Haven Health, http://yalenewhavenhealth.org/library/healthguide/en-us/illnessconditions/topic.asp?hwid=support/zp3217

[5] Development of a Method for Measuring Single-Pass Bioaerosol Removal Efficiencies of a Room Air Cleaner, page 223 Karin K. Foarde, James T. Hanley, David S. Ensor, and Peter Roessler http://www.aaar.org/ast_abst/v30n0212.htm

Methodology to Perform Clean Air Delivery Rate Type Determinations with Microbiological Aerosols, page 235 Karin K. Foarde, Eric A. Myers, James T. Hanley, David S. Ensor, and Peter F. Roessler

[6]Ozone is not a substitute for mold removal and its reaction with building materials, but applied by an expert may help deodorize, a cleaning article by Jim Holland - http://www.icsmag.com/CDA/ArticleInformation/features/BNP__Features__Item/0,3035,118663,00.html

[7] Ozone as an oxidant, a few references from the Canadian Government

http://www.hc-sc.gc.ca/hecs-sesc/air_quality/publications/ground_level_ozone/part3/ch7_references.htm

Bogaty, H., Campbell K. S., and Appel, W. D. (1952). The oxidation of cellulose by ozone in small concentrations. Text. Res. J. 22: 81-83.

Bradley, C. E., and Haagen-Smit, A. J. (1951). The application of rubber in the quantitative determination of ozone. Rubber Chem. Technol. 24: 750-755.

Cass, G. R., Nazaroff, W. W., Tiller, C., and Whitmore, P. M. (1991). Protection of works of art from damage due to atmospheric ozone. Atmospheric Environment, 25A( 2): 441-451.

Druzik, J. R. (1985). Ozone: The Intractable Problem. We stern Association for Art Conservation newsletter. Http://sul-server-2.stanford.edu/waac/wn/wn07/wn07-3/wn07-302.html (vol.7, no. 3)

[8] "Health Hazards of some Gases" Jack E. Peterson, P.E., CIH, Ph.D., May, 1987

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

A COMPLETE GUIDE TO MOLD INSPECTION TESTING CLEANUP & PREVENTION

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

    ...
InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

02/08/2010 - 03/28/2003 - InspectApedia.com/sickhouse/Ozone_References.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark