InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
InspectAPedia
Home
| Air
Conditioning
| Electrical
Energy Saving
| Environment
Indoor
| Exteriors | Heating | Home
Inspection
| Insulate
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Solar
Energy
| Structure | Contact Us
Directory of Professionals to Inspect or Test a Building



ENVIRONMENTAL HAZARDS GUIDE
AIR POLLUTANTS, COMMON INDOOR
ALLERGEN TESTS for BUILDINGS
ALLERGENS in BUILDINGS, RECOGNIZING
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
ASBESTOS in Buildings
Carpet Dust
Carpeting and Indoor Air Quality
FLOODS IN BUILDINGS-priorities
FLOODS IN BUILDINGS-mold
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
GAS MEASUREMENT TOOLS
Gas Toxicity Levels
House Dust Analysis
MOLD: A COMPLETE GUIDE TO MOLD
MOLD INFORMATION CENTER
ACCEPTABLE MOLD LEVEL
ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
AFTER THE MOLD CLEANUP
ATTIC MOLD
BATHROOM MOLD
BASEMENT MOLD
BASEMENT MOLD WATER IMPACT
BASICS YOU NEED to FIND, TEST, REMOVE MOLD
Basketball Mold Syndrome - BBMS
BLACK MOLD, HARMLESS COSMETIC
BOOKSTORE - ENVIRONMENTAL
BUYERS GUIDE - home inspections for mold
CARPET MOLD CONTAMINATION
CARPET TEST GUIDE
CARPET STAIN DIAGNOSIS
CARPET TEST GUIDE
CRAWLSPACE MOLD
DIRT FLOOR MOLD CONTAMINATION
DO IT YOURSELF MOLD CLEANUP
DO-IT-YOURSELF WARNINGS
DRYWALL MOLD
ENERGY SAVINGS in BUILDINGS
FIBERGLASS INSULATION MOLD
FLOODS & MOLD CLEAN/PREVENT
FUNGICIDAL SPRAY & SEALANT USE GUIDE
HARMLESS BLACK MOLD
FIND MOLD in BUILDINGS, HOW TO
  CHOOSE SAMPLE POINT
  ESSENTIAL STEPS IN FINDING MOLD
  FLASHLIGHT HELPS FIND MOLD
  SAMPLE POINT CHOICES FOR MOLD TEST
  SAMPLING DRYWALL
  SAMPLING MISTAKES
  USE A FLASHLIGHT
  USING LIGHT TO FIND MOLD
HIDDEN MOLD, HOW TO FIND
  Hidden Mold Behind Paneling
  Hidden Mold Between Framing & Sheathing
  Hidden Mold in Flooring & Subflooring
  Hidden Mold in Wall Cavities
  Light colored toxic molds
  Moisture Gradients and Mold
  Other Places to Look for Hidden Mold
  Recognizing Cosmetic Mold
  Spotting Hard-to-See Mold
  Use a Flashlight to Find Mold
  Wall test cuts to spot hidden mold
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INDOOR AIR QUALITY METHODS COMPARED
INSULATION MOLD
ITCHY FABRICS
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD CLASSES, HAZARD LEVELS
MOLD REMEDIATION CLEARANCE INSPECTION
MOLD CULTURES
MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTOR NEEDED?
MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS
MOLD FREQUENCY in BUILDINGS
MOLD GROWTH on SURFACES, GUIDE TO
MOLD INSPECTORS & MOLD TESTERS
MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TESTING SERVICES
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP - BLEACH
MOLD CLEANUP - HEALTH RISKS
MOLD CLEANUP - MISTAKES to AVOID
MOLD CLEANUP - MEDIA BLASTING
MOLD CLEANUP - WOOD FRAMING & PLYWOOD
MOLD CLEARANCE - POST-REMEDIATION INSPECTION
MOLD KILLING GUIDE
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS
MOLD by MICROSCOPE
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS

MOLD SPRAYS, SEALANTS, PAINTS
MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE
NOISE / SOUND DIAGNOSIS & CURE
ODOR DIAGNOSIS CHECKLIST
ODORS & SMELLS DIAGNOSIS & CURE
RENTERS & TENANTS GUIDE TO MOLD
STUFF THAT IS NOT MOLD
STAIN DIAGNOSIS & GUIDE
TECHNICAL & LAB PROCEDURES
THERMAL TRACKING
TRAPPED MOLD BETWEEN WOOD SURFACES
USING LIGHT TO FIND MOLD

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Moldy subfloor and joists may suggest additional hidden trapped mold contamination -  © Daniel Friedman SUBFLOOR MOLD - What to Do About Trapped Mold Contamination in Building Flooring Layers
InspectAPedia®  -    

  • Procedures to test for mold between floor finish flooring subfloor surfaces
  • Mold suspected between layers of subfloor and finished flooring
  • OPM: use of other people's money to reduce the consultant's risk?
  • Where may mold be hidden in buildings
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

This article discusses the decision to use test cuts or demolition to search for problematic mold reservoirs between building finish flooring and the subfloor, giving examples of when such investigation is warranted and when it is not. Also see TRAPPED MOLD BETWEEN WOOD SURFACES for a discussion of the immobility of mold between wood framing and other surfaces, and see MOLD GROWTH on SURFACES for an index of what mold genera/species are frequently found on various building surfaces and materials.

Our page top photograph shows heavy mold contamination on floor joists and on the visible under-surface of subflooring? What about mold that may be present between the subfloor and the finish flooring above? Is that a problem that justifies demolition of the subfloor?

© Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

A Photo Guide to Inspecting Multiple Layers of Flooring & Subfloors or Wall Studs & Sheathing to Inspect for & Remove Hidden Mold

Test cuts for mold between flooring layers (C) Daniel Friedman Test cuts for mold between flooring layers (C) Daniel Friedman

Our two photographs just above demonstrate a procedure we use to inspect for evidence of high levels of mold trapped between layers of flooring and subflooring in a building.

No invasive mold inspection: If inspection of the finish flooring from the room side (above) shows no evidence of water damage to the flooring itself, the probability that a large amount of water entered the space between flooring layers and thus that there is a significant mold reservoir located there is low and further investigation including subfloor test cuts are probably not justified.

Invasive inspection is justified: Where a history of extensive building leaks, water damage, floor damage, and visible mold suggest to the inspector that further investigation is appropriate, inspecting from the area below the suspected floor, select the highest-risk most-likely moldy location by tracing the water leak path, stains, and or visible mold in the building. (Photograph, above left).

  1. Using a hole saw (see more photos below), cut up through the subflooring to expose the under-side of the finish flooring above, in the area of highest risk.
  2. Inspect for mold, studying all of the surfaces exposed by the test cut: the originally-exposed underside of the subflooring where the cut was made, the upper (previously hidden) side of the subflooring now visible on the upper side of the round plug cut out using the hole saw, both sides of kraft paper or building felt used between the subfloor and finish floor, and finally the exposed underside of the finish flooring (photograph, above right).
  3. If mold is visible in this worst-case area, and presuming that tests indicate that the mold is not simply a cosmetic species, additional test cuts to determine the extent or size of the mold reservoir might be justified.

When cutting a test opening to explore a wood floor installed on sleepers over a concrete slab, we use two diameters of hole saws (see photos in the next section.)

  1. First we cut a larger-diameter round hole (say 2.5") through the finish flooring using our hole saw's larger cutting blade. We remove and save the wooden plug created by this step.
  2. Second we cut a smaller-diameter round hole (say 2") through the subflooring to expose the cavity below.
  3. We examine the exposed and inner or hidden surfaces of each plug which is cut, as well as any rosin paper or other material that may be installed between layers of flooring.
  4. Finally, using a flashlight and often a borescope as well, we explore the floor cavity itself for evidence of visible mold, organic mold-friendly debris, insect activity, or evidence of leaks or flooding.

Removing finish flooring, leaving subflooring in place: in cases where the finish flooring was water damaged from building leaks, the flooring will need to be removed as it is nearly impossible to flatten and secure buckled wood flooring in place. Removing the finish flooring exposes the upper side of the building subfloor for inspection. Of course the under-side of the building subfloor can usually also be inspected from below. If the subflooring is plywood and has become water damaged such that it has delaminated, those areas need to be removed and replaced. If the subflooring is intact and sound, it can be left in place, followed by cleaning or mold removal from all exposed surfaces and if appropriate, treatment with a fungicidal sealant.

Leaving subflooring and flooring in place: In cases where there is no other justification for removing the finish flooring (such as water damaged, buckled finish flooring), even if small areas of mold are suspected or detected between the finish floor and subfloor, or between the subfloor and the upper side of floor joists, the combination of limited size of the mold reservoir, the low probability of air and particle movement from between flooring layers into the occupied space, the effects of building dryout, cleaning, and sealing of potential openings and pathways, in most cases will add up to justification for leaving these materials in place.

Photograph of inspecting for hidden mold with a larger test cut.

Wall, floor, or subfloor test cuts for mold

The photo at right shows us cutting a round hole in a wall to expose the wall cavity. We cut high enough above the floor to avoid the sill plate and to give access to the wall cavity itself. We cut close to but not on top of a wall stud, so that when examining the wall cavity we can examine for hidden mold.

Details of using wall test cuts to inspect for hidden mold in wall cavities can be read at Wall test cuts to spot hidden mold.

 

How to Make (or not make) Random Test Cuts to Check for Mold in Building Cavities

Random wall test openings: We have little confidence in and are reluctant to simply make random test cuts in buildings. Since water can take peculiar paths through hidden openings, such as wall plate holes drilled for pipes or electrical wiring or between single pairs of studs or ceiling or floor joists, cutting a hole that does not reveal a problem is no assurance at all that no hidden mold problems exist.

When to Make Strip Cuts to Look for Hidden Mold in Building Ceilings or Walls

When there is an ongoing building complaint that makes us suspect hidden leaks or mold, if we strongly suspect a hidden mold problem but have not found its precise location, on occasion it is justified to make a "strip cut" across multiple wall studs or ceiling joists, exposing multiple wall cavities.

What makes a lot of sense sense is to study the building carefully to decide on the building points at most risk of having been wet from leaks due to construction details or other site observations. That's where one would make a test cut.

We frequently add text and photos to this series of articles. (See "What MOld Looks Like" and "Stuff that is Not Mold" links at page left). Readers should also review Mold in Fiberglass Insulation in Buildings at our The Mold Information Center - What to Do About Mold in Buildings

Small amounts of mold can be removed simply by cleaning or removing infected materials, something most homeowners can handle -- but see the Warning Notice at the end of this article. Some mold species can make you sick.

OPM: Some Consultants Spend Other People's Money to Reduce Risk For the Consultants, not for the Clients

Extensive demolition for mold cleanup (C) Daniel FriedmanWith this as many topics, even smart people but with no actual field test data to support a view, construct mental models of what they think is happening (yet without a single fact nor shred of evidence) and give aggressive cleanup advice accordingly.

This approach is especially dangerous when the advice suffers what we call the "OPM" problem: that is, Ms. X, the consultant give advice that is safest for her (because the client cannot possibly complain in the future that her advice was not aggressive enough), because the safest (for her) advice does not cost her a dime - the client is the one who pays for the sometimes extreme measures that are suggested.

Consultants who offer OPM-based advice simply playing it safe and they are not earning their fee.

Our photograph (above left) shows extensive demolition performed to remove problem mold on floor framing and subflooring in an older home. In this case the combination of multiple layers of moldy subflooring and flooring combined with a cost comparison of alternative approaches indicated that it was actually less costly to remove the subfloor and clean the joists than to leave the subfloor in place. In other buildings and circumstances it is reasonable and more economical to leave the subflooring in place.

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ENVIRONMENTAL HAZARDS GUIDE
AIR POLLUTANTS, COMMON INDOOR
ALLERGEN TESTS for BUILDINGS
ALLERGENS in BUILDINGS, RECOGNIZING
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
ASBESTOS in Buildings
Carpet Dust
Carpeting and Indoor Air Quality
FLOODS IN BUILDINGS-priorities
FLOODS IN BUILDINGS-mold
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
GAS MEASUREMENT TOOLS
Gas Toxicity Levels
House Dust Analysis
MOLD: A COMPLETE GUIDE TO MOLD
MOLD INFORMATION CENTER
ACCEPTABLE MOLD LEVEL
ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
AFTER THE MOLD CLEANUP
ATTIC MOLD
BATHROOM MOLD
BASEMENT MOLD
BASEMENT MOLD WATER IMPACT
BASICS YOU NEED to FIND, TEST, REMOVE MOLD
Basketball Mold Syndrome - BBMS
BLACK MOLD, HARMLESS COSMETIC
BOOKSTORE - ENVIRONMENTAL
BUYERS GUIDE - home inspections for mold
CARPET MOLD CONTAMINATION
CARPET TEST GUIDE
CARPET STAIN DIAGNOSIS
CARPET TEST GUIDE
CRAWLSPACE MOLD
DIRT FLOOR MOLD CONTAMINATION
DO IT YOURSELF MOLD CLEANUP
DO-IT-YOURSELF WARNINGS
DRYWALL MOLD
ENERGY SAVINGS in BUILDINGS
FIBERGLASS INSULATION MOLD
FLOODS & MOLD CLEAN/PREVENT
FUNGICIDAL SPRAY & SEALANT USE GUIDE
HARMLESS BLACK MOLD
FIND MOLD in BUILDINGS, HOW TO
  CHOOSE SAMPLE POINT
  ESSENTIAL STEPS IN FINDING MOLD
  FLASHLIGHT HELPS FIND MOLD
  SAMPLE POINT CHOICES FOR MOLD TEST
  SAMPLING DRYWALL
  SAMPLING MISTAKES
  USE A FLASHLIGHT
  USING LIGHT TO FIND MOLD
HIDDEN MOLD, HOW TO FIND
  Hidden Mold Behind Paneling
  Hidden Mold Between Framing & Sheathing
  Hidden Mold in Flooring & Subflooring
  Hidden Mold in Wall Cavities
  Light colored toxic molds
  Moisture Gradients and Mold
  Other Places to Look for Hidden Mold
  Recognizing Cosmetic Mold
  Spotting Hard-to-See Mold
  Use a Flashlight to Find Mold
  Wall test cuts to spot hidden mold
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INDOOR AIR QUALITY METHODS COMPARED
INSULATION MOLD
ITCHY FABRICS
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD CLASSES, HAZARD LEVELS
MOLD REMEDIATION CLEARANCE INSPECTION
MOLD CULTURES
MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTOR NEEDED?
MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS
MOLD FREQUENCY in BUILDINGS
MOLD GROWTH on SURFACES, GUIDE TO
MOLD INSPECTORS & MOLD TESTERS
MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TESTING SERVICES
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP - BLEACH
MOLD CLEANUP - HEALTH RISKS
MOLD CLEANUP - MISTAKES to AVOID
MOLD CLEANUP - MEDIA BLASTING
MOLD CLEANUP - WOOD FRAMING & PLYWOOD
MOLD CLEARANCE - POST-REMEDIATION INSPECTION
MOLD KILLING GUIDE
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS
MOLD by MICROSCOPE
MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS

MOLD SPRAYS, SEALANTS, PAINTS
MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE
NOISE / SOUND DIAGNOSIS & CURE
ODOR DIAGNOSIS CHECKLIST
ODORS & SMELLS DIAGNOSIS & CURE
RENTERS & TENANTS GUIDE TO MOLD
STUFF THAT IS NOT MOLD
STAIN DIAGNOSIS & GUIDE
TECHNICAL & LAB PROCEDURES
THERMAL TRACKING
TRAPPED MOLD BETWEEN WOOD SURFACES
USING LIGHT TO FIND MOLD

MOLD INFORMATION CENTER
HIDDEN MOLD, HOW TO FIND

More Information

InspectAPedia® Home & Site Map
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

08/26/2009 - 08/25/2009 - InspectApedia.com/sickhouse/Subfloor_Mold.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark