InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile viewMobile View
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

AIR CLEANER PURIFIER TYPES
AIR FILTER EFFECTIVENESS
AIR FILTERS, FIBERGLASS PARTICLES
AIR FILTERS for HVAC SYSTEMS
AIR FILTERS, OPTIMUM INDOOR
AIR FILTERS, SOURCES FOR
AIR FILTERING STRATEGIES
AIR FILTERING CONTINUOUS FAN OPERATION
AIR HANDLER / BLOWER UNITS
AIR LEAK DETECTION TOOLS

AIR POLLUTANTS, COMMON INDOOR
Air Quality Improvement Strategies
AIR LEAK SEALING PROCEDURE
AIR SEALING STRATEGIES
AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY
AIRBORNE MOLD SPORE COUNT ACCURACY
ALLERGEN TESTS for buildings
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
ANIMAL ALLERGENS / PET DANDER
ANIMAL ENTRY POINTS in buildings

ASBESTOS CLEANUP COMPANIES
ASBESTOS ROOFING / SIDING DUST
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
  ASBESTOS AIR DUCTS
  Asbestos Air Duct Vibration Dampers
  ASBESTOS in CARPETING, PADDING
  ASBESTOS CEILING TILES, Asbestos-Containing
  ASBESTOS DUCTS, HVAC
  ASBESTOS DUCT INSULATION, Asbestos Paper
  ASBESTOS DUCTS, Transite Pipe
  ASBESTOS FIREPROOFING SPRAY-On Coatings
  ASBESTOS FLOOR TILE IDENTIFICATION
  ASBESTOS FLOOR TILE Laboratory Procedures
  ASBESTOS FLOOR TILE PHOTO ID GUIDE
  ASBESTOS FLOORING HAZARD REDUCTION
  ASBESTOS FLOORING REMOVAL GUIDE
  Asbestos Foamed-Over
  ASBESTOS INSULATION
  ASBESTOS PAPER DUCT INSULATION
  ASBESTOS PIPE INSULATION
  ASBESTOS ROOFING, CEMENT & FIBER CEMENT
  ASBESTOS ROOFING / SIDING DUST
  ASBESTOS SIDING CEMENT & FIBER CEMENT
  Asbestos in unusual places
  Asphalt-asbestos Paints & sealants
  Carbon Nanotube Materials
  TRANSITE PIPE AIR DUCTS
  Transite Pipe Chimneys & Flues
  Transite Pipe Water Supply Piping
  VERMICULITE INSULATION
ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS FLOORING REMOVAL GUIDE
ASBESTOS List of Asbestos-Containing Products
ASBESTOS MATERIAL REGULATIONS
ASBESTOS MATERIAL REGULATIONS Update
ASBESTOS MATERIAL REGULATIONS, OSHA Roofing/Siding
ASBESTOS Photo Guide to Materials / Products
ASBESTOS RISK ASSESSMENT
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
ASBESTOS REMOVAL, Wetting Guidelines
Asbestos Under the Microscope
ATTORNEYS and EXPERT WITNESSES

Backdrafting Appliances

BIBLIOGAPHY for ENVIRONMENTAL HEALTH, MOLD, IAQ
BIOGAS PRODUCTION & USE

BIOLOGICAL POLLUTANTS
BIOLOGICAL POLLUTANTS in the HOME - EPA

BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC
BLEACHING MOLD, Advice about
BLOWER DOORS & AIR INFILTRATION
BLUE vs YELLOW COMBUSTION FLAMES
Bisphenol-A, BPA
BLEACHING MOLD, Advice about
BOOK MOLD, Moldy Book Cleaning
BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
BUILDING SAFETY HAZARDS GUIDE

CARBON MONOXIDE - CO
Carbon Nanotube Materials
CARPET MOLD CONTAMINATION
CARPETS & PADDING ODORS IN buildings
Cell phone Radiation Hazards
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHINESE DRYWALL HAZARDS
CHLORINE IN DRINKING WATER
CHLORINE in WATER, HOW TO TEST FOR
CHLORINE IN SEPTIC WASTEWATER
COMBUSTION GASES & PARTICLE HAZARDS

Diethylstilbestrol - DES
DUST ANALYSIS for FIBERGLASS
DUST CONTAMINATION FROM HVAC?
DUST SAMPLING PROCEDURE

EMF ELECTROMAGNETIC FIELDS & HUMAN EXPOSURE
EMF Levels of Cancer Risk
EMF MEASUREMENT PROCEDURES
ENERGY SAVINGS in buildings
ENVIRO-SCARE - PUBLIC FEAR CYCLES
EXTERIORS of buildings

FIBERGLASS HAZARDS
FIBERGLASS INSULATION MOLD
FIBERGLASS PARTICLE CONTAMINATION TEST
Fireplaces & Woodstove Contaminants
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOOR TYPES & DEFECTS
ASBESTOS FLOOR TILE IDENTIFICATION
FORMALDEHYDE HAZARDS

GAS EXPOSURE EFFECTS

HEATING OIL EXPOSURE HAZARDS, LIMITS
HUMIDITY CONTROL & TARGETS INDOORS

IAQ ISSUES, OTHER
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INSULATION INSPECTION & IMPROVEMENT
INSULATION IDENTIFICATION GUIDE
INSULATION, ASBESTOS
INSULATION MOLD

LEED Building Designation & IAQ
LIGHTING, INTERIOR GUIDE
LIGHTNING PROTECTION
UFFI UREA FORMALDEHYDE FOAM INSULATION
LEAD POISONING HAZARDS GUIDE
LEED Building Designation & IAQ
LP & Natural Gas Safety Hazards
Legionella Legionnaires' Disease

METHANE GAS SOURCES
MILDEW in buildings ?
MOISTURE CONTROL in buildings

MOLD: A COMPLETE GUIDE to TEST CLEAN PREVENT
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLINICAL REFERENCE TEXTS
MOLD DOCTORS - ENVIRONMENTAL MEDICINE

MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE STANDARDS
MOLD GROWTH ON SURFACES, PHOTOS
MOLD GROWTH on SURFACES, TABLE OF

MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE

MOLD RELATED ILLNESS GUIDE
MOLD STANDARDS
MOLD TEST KITS for DIY MOLD TESTS
MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS
Museum Artifact Preservation

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE
OIL, HEATING, EXPOSURE HAZARDS, LIMITS
OIL TANKS INSPECT LEAK TEST ABANDON REGS
OXYGEN - O2
OZONE HAZARDS
OZONE for MOLD OR ODORS

PAINTS & COATINGS ODORS IN buildings
Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
PLASTIC CONTAINERS, TANKS, TYPES
PLASTIC HEATER VENT
PLASTIC ODORS-SCREENS, SIDING
PLUMBING SYSTEM ODORS
PVC - VINYL BUILDING PRODUCTS

RADON HAZARD TESTS & MITIGATION

SAFETY HAZARDS GUIDE
SEPTIC SYSTEM ODORS
SEWER GAS ODORS
SIDING VINYL
SMELL PATCH TEST to Track Down Odors
SOUND CONTROL in buildings
SOLAR ENERGY SYSTEMS

STAIN & BIODETERIORATION AGENT CATALOG
STAINS on buildings - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS

SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
SULPHUR & SEWER GAS SMELL SOURCES

THERMAL TRACKING Indicates Heat Loss

Urea Formaldehyde Foam Insulation UFFI
URETHANE FOAM Deterioration, Outgassing

VAPOR BARRIERS & CONDENSATION in buildings
VENTILATION in buildings
VINYL CHLORIDE HEALTH INFO
VINYL Siding or PLASTIC Window ODORS in buildings
Volatile Organic Compounds VOCs

WATER ODORS, CAUSE CURE
WATER TANK SAFETY
WATER TESTS, CONTAMINANTS, TREATMENT
WATER TEST CHOICES & WATER TEST FEES
WATER TREATMENT EQUIPMENT CHOICES
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
World Trade Center Collapse Dust Photos

More Information

Asbestos heating pipe insulation placed by prior owner under the attic floorboards - perhaps he got it free from his heating companyPhotos of Examples of unusual uses of asbestos in buildings -
InspectAPedia®  -         

  • Examples of unusual uses of asbestos insulation material in buildings
  • Asbestos used as building insulation
  • Asbestos pipe insulation mis-placed in attic floor
  • Corrugated asbestos paper insulation photos
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

This article provides examples of examples of unusual uses of asbestos insulation material in buildings, most likely also hazards that should be evaluated. This document assists building buyers, owners or inspectors who need to identify asbestos materials (or probable-asbestos) in buildings by simple visual inspection. We provide photographs and descriptive text of asbestos insulation and other asbestos-containing products to permit identification of definite, probable, or possible asbestos materials in buildings.

While an expert lab test using polarized light microscopy may be needed to identify the specific type of asbestos fiber, or to identify the presence of asbestos in air or dust samples, many asbestos-containing building products not only are obvious and easy to recognize, but since there were not other look-alike products that were not asbestos, a visual identification of this material can be virtually a certainty in many cases.

Also see Asbestos HVAC Ducts a field identification guide to visual detection of asbestos in and on heating and cooling system ducts and flue vents. Also see Micro-Photographs of Dust from the World Trade Center collapse following the 9/11/01 attack. Links to U.S. government and other authoritative research and advice are included.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

ASBESTOS PAPER DUCT INSULATION Asbestos pipe insulation, found under attic floor as house insulation

Asbestos heating pipe insulation placed by prior owner under attic floorboards



This unusual "attic insulation," made of corrugated asbestos "paper" laid flat, was in the floor of a 1940s house in New York state. We speculated that the installer had a source of "free" insulation and that it was installed before the asbestos scare.

Asbestos Gas-Fireplace Materials in Old Houses

Photograph of a pre-1900 gas fireplace containing asbestos Photograph of a pre-1900 gas fireplace containing asbestos

This pre-1900 gas fireplace found in a Minnesota home used tufts of asbestos fibers to support the heating flame. [Photograph courtesy Roger Hankey.]

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

ASBESTOS FLOORING HAZARD REDUCTION
ASBESTOS-FREE INSULATION MATERIALS
ASBESTOS IDENTIFICATION IN buildings
ASBESTOS ROOFING / SIDING DUST
Asbestos Risk Assessment
Asbestos in Good Condition
Asbestos in Poor Condition
ASBESTOS REMOVAL, Amateur, Incomplete
Asbestos Removal, Certification
Abandoned Pipe Insulation
Asbestos Foamed-Over
Asbestos in unusual places
Paper Duct Insulation Containing Asbestos
Carbon Nanotube Materials
Transite Pipe Chimneys & Flues
Asbestos HVAC Ducts
Asbestos Duct Vibration Dampers
TRANSITE PIPE AIR DUCTS
Fireproofing containing Asbestos
ASBESTOS Photo Guide to Materials / Products
MOLD in FOAM INSULATION, RESISTANCE
CEILING TILES - Asbestos-Containing
ASBESTOS FLOOR TILE IDENTIFICATION
VERMICULITE INSULATION
ASBESTOS REMOVAL, Wetting Guidelines
Asbestos Under the Microscope
BUILDING SAFETY HAZARDS GUIDE

INSULATION IDENTIFICATION GUIDE
  ASBESTOS-FREE INSULATION MATERIALS
  ASBESTOS IDENTIFICATION IN buildings
  Asbestos Pipe Insulation
  Balsam Wool Batt Insulation
  BLOWN-IN INSULATION
  BRICK LINED WALLS
  BRICK VENEER WALL INSULATION
  Cellulose loose fill insulation
  Ceramic Insulation
  Concrete insulation, light-weight
  Cotton Insulating Batts
  Fiberglass Insulation
  Foam Board Insulation
  Foam Insulation Types - Visual Id
  Homasote & Other Insulating Board
  Icynene Foam Spray Insulation
  Mineral Wool - Rock Wool Insulation
  Paper Duct Insulation
  Perlite Insulation
  PHENOLIC FOAM INSULATION
  POLYISOCYANURATE FOAM INSULATION
  POLYISOCYANURATE FOAM BELOW SLABS
  POLYSTYRENE FOAM INSULATION
  STRESS SKIN INSULATED PANELS
  STUCCO OVER FOAM INSULATION
  SUPER HI-R INSULATION
  SUPERINSULATION RETROFIT
  VERMICULITE INSULATION

  • 7/07: thanks to Roger Hankey & Cheryll Brown, ASHI home inspectors in Minnesota, for the gas fireplace photographs. Mr. Hankey is a past chairman of the ASHI Standards Committee, serves as co-chairman of ASHI legislative committee, and has served in other ASHI professional and leadership roles.
  • 3/07: thanks to Gary Randolph, Ounce of Prevention Home Inspection, LLC Buffalo, NY, for attentive reading and editing suggestions. Mr. Randolph can be reached in Buffalo, NY, at (716) 636-3865 or email: gary@ouncehome.com
  • 06/07: thanks for photographs of transite asbestos heating ducts, courtesy of Thomas Hauswirth, Managing Member of Beacon Fine Home Inspections, LLC and (in 2007) Vice President, Connecticut Association of Home Inspectors Ph. 860-526-3355 Fax 860-526-2942 beaconinspections@sbcglobal.net

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.

Asbestos Hazard, Testing, Removal, References & Products

  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • ASBESTOS IDENTIFICATION IN buildings How to find and recognize asbestos in buildings - visual inspection methods, list of common asbestos-containing materials
  • Asbestos Identification and Testing References
    • Asbestos Identification, Walter C.McCrone, McCrone Research Institute, Chicago, IL.1987 ISBN 0-904962-11-3. Dr. McCrone literally "wrote the book" on asbestos identification procedures which formed the basis for current work by asbestos identification laboratories.
    • Stanton, .F., et al., National Bureau of Standards Special Publication 506: 143-151
    • Pott, F., Staub-Reinhalf Luft 38, 486-490 (1978) cited by McCrone
  • Asbestos in Good Condition
  • Asbestos in Good Condition
  • Asbestos in Your Home U.S. EPA, Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
  • Asbestos HVAC Ducts and Flues field identification photos and guide
  • Asbestos NESHAP Adequately Wet Guidance, EPA340/1-90-019, December 1990, U.S. ENVIRONMENTAL PROTECTION AGENCY, Office of Air Quality Planning and Standards, Stationary Source Compliance Division, Washington, DC 20460,original web source: http://www.epa.gov/region04/air/asbestos/awet.htm
  • Asbestos paper duct wrap
  • Asbestos products and their history and use in various building materials such as asphalt and vinyl flooring includes discussion which draws on Asbestos, Its Industrial Applications, D.V. Rosato, engineering consultant, Newton, MA, Reinhold Publishing, 1959 Library of Congress Catalog Card No.: 59-12535 (out of print, text and images available at InspectAPedia.com).
  • Asbestos Transite Chimneys, Flues, & Pipes in buildings
  • Asbestos under the microscope
  • Asbestos Vibration Dampers & Asbestos in the Air Handler
  • Ceiling tiles: How to recognize ceiling tiles that may contain asbestos
  • Examples of unusual uses of asbestos in buildings
  • Fiberglass: Indoor Air Quality Investigations: Health Concerns About Airborne Fiberglass: Fiberglass in Indoor Air from HVAC ducts, and Building Insulation
  • Enviro-Scare: Electric Power Lines, Electromagnetic Fields, Cancer Risk, & "Enviro-Scare" - The Normal Curve Cycle of Public Fear of Environmental Issues
  • Dust from the World Trade Center collapse following the 9/11/01 attack: the lower floors of this building contained spray-on fire-proofing asbestos materials.
  • Asbestos Information Links: Asbestos Detection, Testing, Recognition, Hazards, Field Photos, and Information Sources, including health-related links such as legal services and information about mesothelioma and other cancers.
  • "Handling Asbestos-Containing roofing material - an update", Carl Good, NRCA Associate Executive Director, Professional Roofing, February 1992, p. 38-43
  • EPA Guidance for Controlling Asbestos-Containing Materials in buildings, NIAST, National Institute on Abatement Sciences & Technology, [republishing EPA public documents] 1985 ed., Exposure Evaluation Division, Office of Toxic Substances, Office of Pesticides and Toxic Substances, U.S. Environmental Protection Agency, Washington,D.C. 20460
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com