ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

MOLD: A COMPLETE GUIDE to TEST CLEAN PREVENT
ALLERGEN TESTS for BUILDINGS
ASBESTOS IDENTIFICATION IN BUILDINGS
ATTORNEYS and EXPERT WITNESSES
BIOLOGICAL POLLUTANTS in the HOME - EPA
BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC
BLEACHING MOLD, Advice about
BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
CARPET MOLD CONTAMINATION
CARPET TEST PROCEDURE
CARPETING & INDOOR AIR QUALITY
CARPETS & PADDING ODORS IN BUILDINGS
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHINESE DRYWALL HAZARDS
CLEARANCE INSPECTIONS - MOLD CLEANUP
CONDENSATION or SWEATING PIPES, TANKS

CRAWL SPACES
  CRAWL SPACE DRYOUT PROCEDURES
  CRAWL SPACE GROUND COVERS
  CRAWL SPACE INSULATION RETROFIT
  CRAWL SPACE SAFETY ADVICE
  CRAWL SPACE VAPOR BARRIER
  CRAWLSPACE MOLD ADVICE
  MOLD CLEANUP by MEDIA BLASTING
  MOLD ON DIRT FLOORS
  SUMP PUMPS

CONDENSATION or SWEATING PIPES, TANKS
CONDENSATION on WINDOWS & SKYLIGHTS
DEW POINT CALCULATION for WALLS
DEW POINT TABLE - CONDENSATION POINT GUIDE
DIRT FLOOR MOLD CONTAMINATION
Disinfectants
Disinfecting Buildings with Bleach
DIRT FLOOR MOLD CONTAMINATION

DO-IT-YOURSELF MOLD CLEANUP WARNINGS
DRYWALL HAZARDS, CHINESE
DRYWALL INSTALLATION Best Practices
DIRECTORY of MOLD / ENVIRONMENTAL EXPERTS
DIRT FLOOR MOLD CONTAMINATION
Disinfectants
Disinfecting Buildings with Bleach
DO-IT-YOURSELF MOLD CLEANUP WARNINGS
DRYWALL MOLD
DUCT SYSTEM & DUCT DEFECTS
DUST ANALYSIS for FIBERGLASS
DUST CONTAMINATION FROM HVAC?
DUST SAMPLING PROCEDURE

EFFLORESCENCE, Salts & White / Brown Deposits
FIBERGLASS HAZARDS
FIBERGLASS INSULATION MOLD
FIELD INVESTIGATION SERVICE
FIND MOLD, ESSENTIAL STEPS
FIND MOLD in BUILDINGS, HOW TO
FIRE DAMAGE vs MOLD DAMAGE

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
  FIRST PRIORITIES
  BUILDING ENTRY PROCEDURE AFTER FLOODING
  CRAWL SPACE SAFETY ADVICE
  DRINKING WATER - EMERGENCY PURIFICATION
  DRINKING WATER - EMERGENCY SOURCES
  ELECTRICAL SAFETY for Flood Damage Inspectors
  FLOOD RESPONSE CHECKLIST
  FLOOD DAMAGE RFERENCES
  FLOOD VENTS & FLOOD PORTS
  FLOOD-CAUSED MOLD, PREVENTION
  FLOODED HEATING EQUIPMENT REPAIR
  FLOODED WATER HEATER REPAIR
  FLOODED SEPTIC SYSTEMS, REPAIR
  FOUNDATION CRACKS & DAMAGE GUIDE
  FOUNDATION DAMAGED, by FLOODING
  FRAMING DAMAGE, INSPECTION, REPAIR
  MOBILE HOMES, DOUBLEWIDES, TRAILERS
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  MOLD PREVENTION AFTER FLOODING
  MOLD PRODUCTS, INEFFECTIVE
  MOLD RESISTANT CONSTRUCTION
  SEPTIC SYSTEMS & FLOODS
  SEPTIC BACKUP PREVENTION
  SEWAGE BACKUP, WHAT TO DO
  SEWAGE BACKUP TEST & CLEANUP
  SEWAGE BACKUP PREVENTION
  SEWAGE CONTAMINATION in BUILDINGS
  SEWAGE NITROGEN CONTAMINANTS
  SEWAGE PATHOGENS in SEPTIC SLUDGE
  SEWAGE PUMPS
  SEWER BACKUP PREVENTION
  SEWER GAS ODORS
  SEWAGE & SEPTIC CONTAMINANTS
  SEWAGE CONTAMINATION in BUILDINGS
  SEWAGE PATHOGENS in SEPTIC SLUDGE
  WHEN TO STOP LOOKING FOR MOLD
  Wind Damage to Roofs

FLOOD DAMAGE TO FOUNDATIONS
FLOODS IN BUILDINGS-mold
FLOOR & SUBFLOOR MOLD, HIDDEN
FLOOR TYPES & DEFECTS
FLOOR TILE ASBESTOS IDENTIFICATION
FOUNDATION WATERPROOFING
FRENCH DRAINS
FREEZE-PROOF A BUILDING
FUNGICIDAL SPRAY & SEALANT USE GUIDE

GAS EXPOSURE EFFECTS, TOXIC
  Carbon Dioxide - CO2
  Carbon Monoxide - CO
  METHANE GAS SOURCES
GAS DETECTION & MEASUREMENT
HEATING OIL EXPOSURE HAZARDS, LIMITS
HEATING SYSTEM ODORS

HIDDEN MOLD, HOW TO FIND
HUMIDITY CONTROL & TARGETS INDOORS
INDOOR AIR HAZARDS TABLE
Indoor Air Pollution Book Online CPSC
INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INDOOR AIR QUALITY METHODS COMPARED

INSULATION INSPECTION & IMPROVEMENT
INSULATION MOLD
LABORATORY SERVICES
LEAD POISONING HAZARDS GUIDE
LEAD CONTAMINATION in WATER, HOW to TEST
LEAD EXPOSURE HAZARDS INDOORS
LEAD HAZARDS & FEAR: Enviro-Scare
LEAD IN DRINKING WATER, HOW to REDUCE
LEAD PIPES in BUILDINGS
LEAD PAINT REMOVAL ALTERNATIVES
LEAD in ROOFING, EFFECTS
LEAD TEST KIT for HOME USE
LEAD WATER PIPING HAZARDS & REMEDIES
Legionella Legionnaires' Disease
Legionella BACTERIA & HVAC Equipment
MEDIA BLASTING for MOLD REMOVAL
MEDIA BLASTING for MOLD REMOVAL
METHANE GAS SOURCES
MICROSCOPE DIGITAL PHOTOGRAPHY
MILDEW in BUILDINGS ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION
MOISTURE CONTROL in BUILDINGS

MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD AGE - Old is the Mold?

MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD CLASSES, HAZARD LEVELS
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP, DO IT YOURSELF
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP by MEDIA BLASTING
MOLD CLEARANCE INSPECTIONS
MOLD CLEARANCE: FOLLOWUP STEPS
MOLD CONSULTANTS/INSPECTORS
MOLD CONTAMINATION LEVELS
MOLD CULTURE TEST KIT VALIDITY
MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTORS - ENVIRONMENTAL MEDICINE
MOLD or INDOOR AIR EMERGENCY RESPONSE
MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS
MOLD GROWTH ON SURFACES, PHOTOS
MOLD GROWTH on SURFACES, TABLE OF
MOLD GROWTH in/on BUILDING INSULATION
MOLD INFORMATION CENTER
MOLD INSPECTORS & MOLD TESTERS
MOLD INVESTIGATION PROCEDURE TIPS
MOLD INVESTIGATION REPORTS

MOLD KILLING GUIDE
MOLD LAB REPORTS
MOLD LEVEL IN AIR, VALIDITY
MOLD LEVEL REPORTS
MOLD LEVELS IN BUILDINGS

MOLD ODORS, MUSTY SMELLS
MOLD on or in CARPETS
MOLD ON DIRT FLOORS
MOLD PREVENTION GUIDE
MOLD RELATED ILLNESS GUIDE
MOLD RESISTANT CONSTRUCTION
MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST METHODS, ACCURACY
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES
MSDS Material Safety Data Sheets
MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS
MYCOPHOBIA, STAINS MISTAKEN for MOLD
MYCOTOXIN EFFECTS of MOLD EXPOSURE

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE
OIL, HEATING, EXPOSURE HAZARDS, LIMITS
OIL TANKS INSPECT LEAK TEST ABANDON REGS
OZONE for MOLD OR ODORS

PAINTS & COATINGS ODORS IN BUILDINGS
PARTICLE SIZES & IAQ
Particulates & Allergens Indoors
Pesticide Exposure Hazards
PET ALLERGEN REMEDIES
RENTERS & TENANTS GUIDE TO MOLD
ROT, TIMBER FRAME

SEPTIC BACKUP PREVENTION
SEPTIC BACKUP REPAIR
SEPTIC METHANE GAS
SEPTIC SYSTEM ODORS
SLIDE PREPARATION, MICROSCOPE
SMELL PATCH TEST to Track Down Odors
SEWAGE BACKUP, WHAT TO DO
SEWAGE BACKUP TEST & CLEANUP
SEWAGE BACKUP PREVENTION
SEWER GAS ODORS
SEWER GAS ODORS in COLD WEATHER
SEWAGE BACKUP, WHAT TO DO
SEWAGE BACKUP TEST & CLEANUP
SEWAGE BACKUP PREVENTION
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIN DIAGNOSIS on BUILDING INTERIORS
STAINS on INDOOR SURFACES: PHOTO GUIDE
STAINS & Thermal Tracking

SUMP PUMPS
  SEPTIC SYSTEM PUMPS
  Sump Pump Discharge
  Sump Pump Inspection
  Sump Pump Types
    Submersible Sump Pump Guide
    Pedestal Type Sump Pump Guide
    Battery Backup Sump Pump Choices
    Water Powered Sump Pump Guide
  Sump Pump Single vs Duplex

TRAPPED MOLD BETWEEN WOOD SURFACES
USING LIGHT TO FIND MOLD
VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in buildings
VINYL Siding or PLASTIC Window ODORS in buildings
VINYL CHLORIDE HEALTH INFO

WATER BARRIERS, EXTERIOR BUILDING

WATER ENTRY in buildings
  ATTIC LEAKS Moisture or Mold
  BARRIERS, EXTERIOR WATER
  BASEMENT CEILING VAPOR BARRIER
  BASEMENT De-Watering Systems
  BASEMENT HEAT LOSS
  BASEMENT LEAKS, INSPECT FOR
  BASEMENT WATERPROOFING
  BASEMENT WATER ENTRY PREVENTION
  CATCH BASINS
  Chimney Leaks
  CONDENSATION or SWEATING PIPES, TANKS
  CONDENSATION on WINDOWS & SKYLIGHTS
  CORROSION in ELECTRICAL PANELS
  CRAWL SPACE DRYOUT PROCEDURES
  DEW POINT CALCULATION for WALLS
  DEW POINT TABLE - CONDENSATION POINT GUIDE
  DRYER VENTING
  DRYWELLS, FRENCH DRAINS for FLAT SITES
  DRYWELL DESIGN & USES
  EFFLORESCENCE, Salts & White / Brown Deposits
  ELECTRIC PANEL MOISTURE
  EXTERIOR WATER SOURCE ELIMINATION
  FLOOD Damage Assessment & Repairs
  FLOOD DAMAGED FOUNDATIONS
  FLOOD VENTS & FLOOD PORTS
  FLOODS IN buildings-priorities
  FOUNDATION DRAINS, INTERIOR
  FOUNDATION WATERPROOFING
  GEOTEXTILES & DRAINAGE MATS
  GRADING & SITE WORK, EXTERIOR
  GUTTERS & DOWNSPOUTS
  HUMIDITY CONTROL & TARGETS INDOORS
  HOUSEWRAP AIR & VAPOR BARRIERS
  LOG HOME Leak Diagnosis & Cure
  LOG HOME Condensation &Moisture
  MOISTURE in BUILDING WALLS, EFFECTS
  MOISTURE in CELLULOSE INSULATION
  MOISTURE CALCULATIONS
  MOISTURE CONTROL in BUILDINGS
  MOISTURE METER STUDY
  MOISTURE PROBLEMS: CAUSE & CURE
  MOLD in buildings
  MOLD PREVENTION AFTER FLOODING
  MOLD RESISTANT CONSTRUCTION
  PERIMETER DRAIN SYSTEMS
  ROOF VENTILATION SPECIFICATIONS
  Soffit Intake Vents & Attic Condensation
  SEALERS, Basement Floor & Wall Moisture
  SEWAGE CONTAMINATION
  SITE & SURFACE DRAINAGE
  SUMP PUMPS GUIDE
  SWEATING (CONDENSATION) on PIPES, TANKS
  VENTILATION in BUILDINGS
  VENTILATION DESIGN PROBLEMS & SOLUTIONS
  VENTILATION, WHOLE HOUSE STRATEGIES
  WATER ENTRY in BUILDINGS
  WET BASEMENT PREVENTION
  WINDOW / DOOR AIR LEAK SEALING HOW TO
  Window Flashing & Sealing Guide
  WINDOW LEAKS INTO BASEMENT


More Information

Flood waters rising at Wappingers Creek (C) Daniel FriedmanFlood Damage Assessment & Repair: First Priorities after a Flood
How to Minimize Flooded Building Damage, Repair Advice, Mold Prevention
InspectAPedia®  -      

  • First priorities of what to do after a home has been flooded
  • Flood damage assessment, building entry safety, repair priorities
  • Priority of repairs for buildings after flooding & water entry
  • Mold prevention for flood-damaged buildings & homes
  • Getting electrical, heating, air conditioning, water piping, drain piping, septic systems working again after building floods
  • Burst pipe response to minimize mold damage
  • How to minimize mold damage after building leaks or flooding: "Anti mold" procedures that work and ones that don't work or are unsafe
  • How to clean up a moldy building after flooding
  • Questions & answers about inspecting & repairing homes & other buildings after flooding from hurricanes, rising floodwaters, burst pipes, sewer backups, etc.

Response to building flooding or storm damage: safety, damage assessment, repair priorities, how to proceed. This is the first in our series of building flood damage articles on steps to take to safely enter and repair homes or other buildings after area flooding due to hurricanes, rising floodwaters, burst pipes, or other water flooding. We discuss safety for people entering flooded buildings, steps to preserve and protect the building from further damage after it has been flooded, how to get mechanical systems up and running again, evaluating for the need for structural repairs, demolition, and cleaning, and avoid mold in a flooded building.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

FIRST PRIORITIES: What to Do After a Building Has Been Flooded

Hazards in and around flooded buildings include risk of structural collapse, risk of septic system collapse, trip and fall injury hazards, electrical shock hazards, fire and explosion hazards where natural gas or bottled gas are present, toxic sludge and materials containing waterborne bacteria, such as the E. coli and Enterococci bacteria, toxic mold growth indoors.

Listed just below are quick, simple steps to minimize damage in a flooded building. Separately our "Flood Response Checklist" lists key actions you should take after building flooding to minimize mold damage, and includes some safety warnings.

  • If You Have Been Injured seek medical care at the nearest hospital or emergency facility. Floodwaters are often contaminated by sewage and there is risk of serious infection if wounds are not cleaned and treated.
  • Check on Neighbors to see if there are elderly or infant neighbors who are trapped, injured, or otherwise need assistance. Help a neighbor who may require special assistance--infants, elderly people, and people with disabilities. Elderly people and people with disabilities may require additional assistance. People who care for them or who have large families may need additional assistance in emergency situations.
  • Watch out: DO NOT ENTER a BUILDING in THESE CONDITIONS:
    • If the building is still flooded: Flood waters often undermine foundations, causing sinking, floors can crack or break and buildings can collapse.
    • Collapse hazards: If the building is damaged or has moved off of its foundation: Damage to the building may mean that there is a risk of collapse. Buildings which have moved off of their foundation - ruptured gas or electrical lines are extremely dangerous. See EARTHQUAKE DAMAGED FOUNDATIONS and  FLOOD DAMAGE TO FOUNDATIONS

      Even the smallest shift of a building on or off of its foundation, possibly less than an inch, can rupture gas piping or electrical wiring, creating a dangerous condition. See FOUNDATION INSPECTION & DIAGNOSIS and also FLOOD DAMAGE TO FOUNDATIONS
    • Electrocution hazards: If there are live electrical systems or wires: Where electrical wiring is live and wet or under water or even simply standing in water or on a wet surface without special protection can lead to a fatal electrical shock. See Electrical Inspection Safety. Below we also warn about use of electrical generators.
    • Gas explosion hazards: If there there are damaged, loose, or broken gas piping or other fuel spills that could result in a fire or explosion. Make sure that all of the utilities, electricity, gas, even water, have been safely shut down.
    • Buildings that have not been declared safe: Avoid entering ANY building (home, business, or other) before local officials have said it is safe to do so. Buildings may have hidden damage that makes them unsafe.
  • Avoid disaster areas: Your presence might hamper rescue and other emergency operations, and put you at further risk from the residual effects of floods, such as contaminated waters, crumbled roads, landslides, mud flows, and other hazards.
Wet crawl space unsafe to enter (C) Daniel Friedman
  • Crawl space safety warnings

  • Crawl spaces (or flooded basements) that are unsafe - For a guide to safe entry in building crawl spaces and to areas that should not be entered, see CRAWL SPACE SAFETY ADVICEsee

    Flooded crawl spaces may be contaminated with sewage bacteria, mold, rodents, or chemicals.

    Flooded crawl spaces may be in danger from collapse of the structure overhead.

    There may be a danger of electrocution in crawl spaces, especially wet ones, if electrical power remains on.

  • Continue to listen to a NOAA Weather Radio: or local radio or television stations and return home only when authorities indicate it is safe to do so. Flood dangers do not end when the water begins to recede; there may be flood-related hazards within your community, which you could hear about from local broadcasts.
  • Do not work alone: if you fall or are injured and are alone you may not receive prompt assistance. If you must work alone despite this advice, be sure you have a working radio or cell phone to use to summons assistance
  • Drinking water may be unavailable or it may be contaminated. Do not assume that municipal water or water from private wells is safe to drink. See DRINKING WATER - EMERGENCY SOURCES and also DRINKING WATER - EMERGENCY PURIFICATION
  • Electrocution hazards: When leaving a building because of impending flooding, leave the electricity turned OFF. Do not turn electricity back on until the building is dry and safe. Using a portable electricity generator in a waterlogged or damaged home in a disaster area after hurricanes, earthquakes, floods can be very dangerous, risking death by electrocution, gas explosion, or by carbon monoxide poisoning. Above we also warned about electrocution hazards in buildings where the electricity has not been shut off.
  • Gas leak risks: Watch out for gas leaks in flooded buildings - flooding moves buildings & causes gas line leaks. Do not Smoke Near or Inside Buildings that Have not Been Declared Safe - a ruptured gas line or leaking gas from appliances could cause a gas explosion and fire. Do not smoke inside buildings. Smoking in a confined area can cause a fire or gas explosion. Do not turn electricity back on in a building where gas leaks could be present. Use a sealed flashlight for inspection, not a plug-in light.
  • Mold, Muck, Insects, Toxic Sludge & Toxic Dust Hazards exist in flooded or storm damaged buildings - a mixture of household chemicals, paints, stored gasoline, lead, sewer or septic system backup, debris and possibly asbestos. Do not begin cleanup efforts without understanding the hazards that may be present and be sure to use the necessary protective clothing and equipment. See FLOOD RESPONSE CHECKLIST.

    We also list after-flood "anti-mold" procedures that do not work or are unsafe - to help you avoid unnecessary expense in dealing with mold after a building flood.

    If your building is already moldy or if you suspect mold related illness in your building, we link to a step by step Mold Action Guide dealing with toxic or allergenic indoor mold and other indoor contaminants: when and how to inspect or test for mold, when to hire an expert, how to clean up a moldy area, when and how to perform post-remediation mold testing.

    How to Prevent Mold Growth After a Building Flood or Burst Pipe

    If your building has just been flooded by rising flood waters, a burst pipe, a waste line leak, a sewer backup, or other event, immediate action may prevent a very costly mold cleanup. Review this checklist. If your building already has an actual or suspected mold problem, review the Mold Action Guide web pages (see links at page left). If you did not take the steps in "Building Floods" below and are reading this section days or weeks after the flooding event, a comprehensive building survey for hidden mold or other contaminants may be needed before a full building cleanup plan can be made.

    Extensive, technically detailed in-depth articles on other mold detection, testing, and prevention methods are organized at our Mold Information Center.

  • Report broken utility lines: such as electrical, gas, water or sewer piping to the appropriate authorities. Reporting potential hazards will get the utilities turned off as quickly as possible, preventing further hazard and injury. Check with your utility company now about where broken lines should be reported.
  • Septic system flood hazards: include sewage-contaminated floods in buildings and risk of collapsing septic systems. See Septic & Cesspool Safety; rope off and prevent access to areas over or close to the septic tank until its condition has been investigated. See Septic Flood Response for advice on repairing septic systems that have been flooded. If your septic system has been flooded.

Questions & Answers regarding this article

Questions & answers about inspecting & repairing homes & other buildings after flooding from hurricanes, rising floodwaters, burst pipes, sewer backups, etc.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP -A Guide to Dealing with Flood Damage & Mold Prevention or Cleanup for Flooded Homes

  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.

  • Action Guide for Mold what to do about mold, cleaning, removal, testing, hiring an expert or doing it yourself - a step by step guide to what to do about mold
  • Clearance Procedures: Post Remediation Mold Inspection & Clearance Testing
  • Floods in Building Setting Priorities and Using Mold Resistant Building - quick steps after a building flood or plumbing leak can prevent costly mold contamination
  • Prevent Mold, How-To Correct the Causes of Mold and Prevent Indoor Mold or other indoor environment problems

  • Flood Response for Septic Systems what to do after a septic system has been exposed to flooding
  • Sewage & Septic Backups and what to do about sewage spillage in buildings
  • Septic Tank Location - How to Find the Septic Tank, how deep will the cover be, how to document its location
  • Septic Tank Pumping Frequency Guide for Septic Tanks: When, How, What to Watch For when pumping or cleaning septic tanks
  • Sewage Contaminants which may be released from sewage spills from residential septic systems and wastewater disposal systems
  • Sewer Gas Odors diagnosing, finding, and curing septic tank and sewer line smells
  • Sewer Gas - Methane and other septic system gas explosion or asphyxiation hazards such as hydrogen sulfide
  • When Not to Pump a Septic Tank to avoid damage, unsafe conditions, or wasting money

  • Allergy & Mold Products to reduce indoor mold or allergen levels
  • ATTIC CONDENSATION CAUSE & CURE and Ice Dam Leaks - Detection and Correcting Venting and Condensation Problems in Buildings
  • How to Clean Moldy Wood Framing & Sheathing How to clean/seal mold from/on exposed lumber or plywood subfloor or roof sheathing indoors - some suggestions based on our field and laboratory research
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?
  • Mold-Resistant Building Practices, advice from an expert on how to prevent mold after a building flood and how to prevent mold growth in buildings by selection of building materials and by anti-mold construction details.
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.

  • Mold FAQs Answers to Most Questions about Indoor Mold, Mold Related Illness, Mold Cleanup, Mold Prevention
  • Mold Info Center Mold Home Page
  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. (727) 595-4211 mark@BestTampaInspector.com 11/06
  • Hankey and Brown home inspectors, Eden Prairie, MN, technical review by Roger Hankey, prior chairman, Standards Committee, American Society of Home Inspectors - ASHI. 952 829-0044 - hankeyandbrown.com 11/06
  • Arlene Puentes, a licensed home inspector, educator, and building failures researcher in Kingston, NY. 11/29/06
  • Repairing Your Flooded Home American Red Cross and FEMA - PDF - English
  • Como Reparar su Hogar Inundado American Red Cross and FEMA - PDF - espanol
  • Flood Cleanup - Avoiding Indoor Air Quality Problems US EPA Fact Sheet
  • Cleaning Up After a Flood Texas Department of State Health Services.
  • ...

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Environmental Health & Investigation Bibliography - our technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Adkins and Adkins Dictionary of Roman Religion discusses Robigus, the Roman god of crop protection and the legendary progenitor of wheat rust fungus.
  • Kansas State University, department of plant pathology, extension plant pathology web page on wheat rust fungus: see http://www.oznet.ksu.edu/path-ext/factSheets/Wheat/Wheat%20Leaf%20Rust.asp
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • "Repairing your Flooded Home", American Red Cross & FEMA: Federal Emergency Management Agency, FEMA PO Box 2012, Jessup MD 20794-2012. Printed copies of this book are available from the American Red Cross, from your local Red Cross chapter, or by writing to the address above. Web search 10/4/2010, original source: http://www.redcross.org/www-files/Documents
    /pdf/Preparedness/file_cont333_lang0_150.pdf
    Same document from FEMA in raw text form:
  • US EPA - Mold Remediation in Schools and Commercial Building [Copy on file at /sickhouse/EPA_Mold_Remediation_in_Schools.pdf ] - US EPA
  • US EPA - Una Breva Guia a Moho - Hongo [Copy on file as /sickhouse/EPA_Moho_Guia_sp.pdf - en Espanol

Allergies, Allergens, Allergy Testing in Buildings - References & Products

  • Air Conditioning System Blower Fans & Filters Cascading for Optimum Indoor Air Quality
  • Allergen Tests in Buildings advice about how to test, what to look for, in evaluating the level of dog, cat, or other animal allergens in a building
  • "IgG Food Allergy Testing by ELISA/EIA, What do they really tell us?" Sheryl B. Miller, MT (ASCP), PhD, Clinical Laboratory Director, Bastyr University Natural Health Clinic - ELISA testing accuracy: Here is an example of Miller's critique of ELISA http://www.betterhealthusa.com/public/282.cfm - Townsend Letter for Doctors and Patients
    The critique included in that article raises compelling questions about IgG testing assays, which prompts our interest in actually screening for the presence of high levels of particles that could carry allergens - dog dander or cat dander in the case at hand.
    http://www.tldp.com/issue/174/IgG%20Food%20Allergy.html contains similar criticism in another venue but interestingly by the same author, Sheryl Miller. Sheryl Miller, MT (ASCP), PhD, is an Immunologist and Associate Professor of Basic and Medical Sciences at Bastyr University in Bothell, Washington. She is also the Laboratory Director of the Bastyr Natural Health Clinic Laboratory.
  • Allergens: Testing for the level of exposure to animal allergens is discussed at http://www.animalhealthchannel.com/animalallergy/diagnosis.shtml (lab animal exposure study is interesting because it involves a higher exposure level in some cases
  • Allergens: WebMD discusses allergy tests for humans at webmd.com/allergies/allergy-tests
  • Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
  • Atlas of Mold Related Illness Symptoms & Complaints - long list of both documented, studied mold related illness, and complaints ascribed to mold contamination or allergens in buildings
  • Cat Dander: how to inspect and test a building for past or current presence of cats, cat hair, cat dander, and cat allergens
  • Clinical Atlas of Mold Toxicity - An Online Description of Toxic, Pathogenic, Allergenic Fungi, Fungal Diseases
  • Fiberglass Insulation Contains Mold© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?
  • Mold Action Guide detailed guide on finding, removing, and preventing indoor mold contamination
  • Odors, Odor Detection, Smells, & Gases how to find and identify sources of noxious or toxic odors and gases
  • Other environmental risks, Our much longer list: Asbestos, carbon monoxide, electromagnetic fields, etc.
  • Ozone: The Use of Ozone Indoors for Control of Odors and Mold Removal in Buildings: A Summary of Hazards and False Claims.
  • Pollen Allergens: identification, plant pollen and indoor air quality
  • Products to Reduce Mold & Allergy Problems to reduce indoor mold or allergen levels: air cleaners, air purifiers, dust mite covers, vacuum cleaners, crawl space vents
  • Recognizing Allergens: What various indoor allergens look like - identification photos to help identify pollen, dust mites, animal dander, toxic or allergenic mold - Common Mold and other Allergens, Irritants, Remedies & Advice
  • Rodent control issues, including dander, fecal, and urine contamination of Buildings and Building insulation are discussed at our
  • Sewage and Septic backup contamination in Buildings: inspection, testing, remediation, & references to expert sources
  • Action Guide: What to do about mold, mildew, and other indoor allergens
  • ...

Mold Contamination Testing, Cleanup, Prevention: references & products

  • GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminantsThe Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
  • Aerobiology, Building Science, Microscopy, & Laboratory References, an extensive technical bibliography
  • Allergens: what they look like in buildings
  • Associations: Sick House, Sick Building, SBS - Air Quality, Government, Private Associations and Information Resources
  • Atlas of Clinical Fungi, 2nd Ed., GS deHoog, J Guarro, J Gene, & MJ Figueras, Centraalbureau voor Schimmelcultures, Universitat Rovira I Virgili, 2000, ISBN 90-70351-43-9 (you can buy this book at Amazon) - The Atlas of Clinical Fungi is also available on CD ROM
  • Atlas of Mold Related Illness: Index of Symptoms and health, physical, neurological, psychological, and other complaint which people suspect may be mold or building-related.
  • Atlas of Indoor Mold, Online Clinical Mold Atlas, Toxins, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • Black Mold that is Harmless Photos of recognizable, usually harmless black mold on wood, bluestain, ceratocystis, ophistoma
  • Building Floods: quick steps after a building flood or plumbing leak can prevent costly mold contamination
  • Classes of Mold: what types of cosmetic, allergenic, or toxic mold are a problem? Can mold be cleaned-up successfully?
  • Clinical Mold References - Detailed bibliography of mold reference texts
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • "Disease Prevention Program for Certain Vegetable Crops," David B. Langston, Jr., Extension Plant Pathologist - Vegetables, University of Georgia (PDF document) original source: www.reeis.usda.gov/web/crisprojectpages/209797.html
  • "Disease Prevention in Home Vegetable Gardens," Patricia Donald, Department of Plant Microbiology and Pathology, Lewis Jett
    Department of Horticulture, University of Missouri Extension - extension.missouri.edu/publications/DisplayPub.aspx?P=G6202
  • "Management of Powdery Mildew, Leveillula taurica, in Greenhouse Peppers," Ministry of Agriculture and Lands, British Columbia - Original source: www.agf.gov.bc.ca/cropprot/peppermildew.htm
  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Fiberglass: Mold in Fiberglass Insulation© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation - DJF
  • Fifth Kingdom, Bryce Kendrick, ISBN13: 9781585100224, is available from the InspectAPedia online bookstore - we recommend the CD-ROM version of this book. This 3rd/edition is a compact but comprehensive encyclopedia of all things mycological. Every aspect of the fungi, from aflatoxin to zppspores, with an accessible blend of verve and wit. The 24 chapters are filled with up-to-date information of classification, yeast, lichens, spore dispersal, allergies, ecology, genetics, plant pathology, predatory fungi, biological control, mutualistic symbioses with animals and plants, fungi as food, food spoilage and mycotoxins.
  • Fungi, Identifying Filamentous, A Clinical Laboratory Handbook, Guy St-Germain, Richard Summerbell, Star Publishing, 1996, ISBN 0-89863-177-7 (English) (buy at Amazon)
  • Looking for Mold Procedure: what mold is often found where in buildings - simple technical presentation
  • Meruliporia: the house eating fungus or "poria"
  • Mold Action Guide: Step-by-Step Instructions, What to do about mold, mildew, and other indoor allergens
  • MOLD APPEARANCE - WHAT MOLD LOOKS LIKE Photos of what mold looks like in buildings
  • MOLD APPEARANCE - STUFF THAT IS NOT MOLD Photos of NOT-mold material that is sometimes mistaken for mold
  • MOLD ATLAS & PARTICLES INDEX, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • MOLD BY MICROSCOPE Mold under the microscope - photo identification of the most common indoor molds found in buildings
  • Mold FAQs Answers to Most Questions about Indoor Mold, Mold Related Illness, Mold Cleanup, Mold Prevention
  • US EPA: Mold Remediation in Schools and Commercial Building [Copy on file at /sickhouse/EPA_Mold_Remediation_in_Schools.pdf ] - US EPA
  • Mold spores in the Home - a Photo ID Library for detection and identification of mold allergens
  • Mold Test Kits - How to Collect and Send Your Own Mold Sample to our mold testing lab or to any mold lab you wish
  • Most Common Indoor Molds Found in Buildings, A Table of
  • Mycology, Fundamentals of Diagnostic, Fran Fisher, Norma B. Cook, W.B. Saunders Co. 1998, ISBN 0-7216-5006-6 (buy this book at Amazon)
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Rot concerns in buildings-some building mold such as Meruliporia incrassata "Poria" risks serious rot and hidden structural damage
  • US EPA: Una Breva Guia a Moho - Hongo [Copy on file as /sickhouse/EPA_Moho_Guia_sp.pdf - en Espanol

OTHER IAQ ISSUES: How To Find and Address Other Indoor Air or Indoor Environment Contaminants Besides Mold

Mold or allergens may not be the only or even the main indoor environmental contaminant. Don't let media attention to mold cause so much enviro-scare fear that other, possibly more urgent hazards go un-addressed.

  • Fiberglass building insulation and HVAC duct work insulation hazards
  • Sewage and Septic backup contamination in buildings: inspection, testing, remediation, & references to expert sources
  • Other environmental risks: Asbestos, carbon monoxide, electromagnetic fields, environmental illness, fiberglass, MCS - multiple chemical sensitivity, toxic gases, etc
  • Indoor Gas Sampling Plan for Residential Buildings lists a number of toxic indoor gases which we test for, depending on the building complaint and building conditions
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Pet control - if you can't say goodbye to your bird, cat, dog, guinea pig, hamster, tropical fish, then limit the areas they occupy and limit the airflow from that area to sleeping or other areas of the building, use allergenic bedding, eliminate wall-to-wall carpeting, improve housecleaning including use of a HEPA-rated vacuum cleaner. For more details see our article Dog, Cat, and Other Animal Dander - Information for Asthmatics and Indoor Air Quality
  • Rodents, Mice, Squirrel Control - I find high levels of mouse and rodent dander, fecal dust, and urine-contaminated dust in some buildings, and high levels of these materials in building insulation in those locations. If you have a mouse problem, particularly if mice and their waste (fecals or urine) are contaminating the building HVAC or building insulation, may need both steps to clean up or remove infected materials and steps to stop an ongoing rodent problem. If squirrels are a problem, the cleanup needs to include closing off entry openings into the building. Get some help from a licensed pest control expert.