InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile View
ENVIRONMENTAL HAZARDS - INSPECT, TEST, REMEDY

AIR POLLUTANTS, COMMON INDOOR
AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY

ALLERGEN TESTS for buildings
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY
ANIMAL ALLERGENS / PET DANDER
ANIMAL ENTRY POINTS in buildings

ASBESTOS CLEANUP COMPANIES
ASBESTOS ROOFING / SIDING DUST
ASBESTOS IDENTIFICATION IN buildings
ATTIC MOLD

BASEMENT MOLD
BASEMENT MOLD WATER IMPACT
BASICS YOU NEED to FIND, TEST, REMOVE MOLD
BASKETBALL MOLD SYNDROME - BBMS
BATHROOM MOLD

BIBLIOGAPHY for ENVIRONMENTAL HEALTH, MOLD, IAQ

BIOLOGICAL POLLUTANTS
BLUE vs YELLOW COMBUSTION FLAMES
BLUERAY Recall
BUILDING SAFETY HAZARDS GUIDE

CARBON MONOXIDE - CO
CARBON MONOXIDE WARNING
CARPETING & INDOOR AIR QUALITY
CARPETING, SELECTION & INSTALLATION
CAT DANDER in buildings
Cell phone Radiation Hazards
CHAIN OF CUSTODY - TEST SAMPLE
CHIMNEY INSPECTION DIAGNOSIS REPAIR
CHIMNEYS & Flues - Asbestos Transite Pipe
CHINESE DRYWALL HAZARDS

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP

MOLD: A COMPLETE GUIDE TO MOLD

MOLD INFORMATION CENTER

ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD
  See a Mold Doctor?
  Clean Up Mold Yourself?
  Mold Health Risks
  How to Find Mold
  How to Clean Up Mold
  Building Flood Response
  Mold Clearance Inspections
  MOLD RESISTANT CONSTRUCTION
  Other IAQ Concerns
AIR TEST FOR MOLD: ACCURACY
AIR TEST SAMPLING CASSETTE STUDY

ALLERGEN TESTS for buildings
ALLERGY TESTS for PEOPLE
ALLERGY TEST ACCURACY

BIOLOGICAL POLLUTANTS
BIOLOGICAL POLLUTANTS in the HOME - EPA
Bisphenol-A, BPA

BLACK MOLD, HARMLESS COSMETIC
BLACK MOLD, TOXIC & ALLERGENIC

BOOK MOLD, Moldy Book Cleaning
BOOKSTORE - ENVIRONMENTAL
BUY PRODUCTS for MOLD & ALLERGY CONTROL
CARBON MONOXIDE - CO
CLEARANCE INSPECTIONS - MOLD CLEANUP

DO IT YOURSELF MOLD CLEANUP
DUST ANALYSIS for FIBERGLASS
DUST SAMPLING PROCEDURE

ENERGY SAVINGS in buildings
FIBERGLASS INSULATION MOLD

FIND MOLD, ESSENTIAL STEPS
FIND MOLD in buildings, HOW TO
FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
  FIRST PRIORITIES
  BUILDING ENTRY PROCEDURE AFTER FLOODING
  DRINKING WATER - EMERGENCY PURIFICATION
  DRINKING WATER - EMERGENCY SOURCES
  ELECTRICAL SAFETY for Flood Damage Inspectors
  FLOOD DAMAGE TO FOUNDATIONS
  FLOOD RESPONSE CHECKLIST
  FLOOD DAMAGE RFERENCES
  FLOOD VENTS & FLOOD PORTS
  FLOOD-CAUSED MOLD, PREVENTION
  FLOODED HEATING EQUIPMENT REPAIR
  FLOODED WATER HEATER REPAIR
  FLOODED SEPTIC SYSTEMS, REPAIR
  FUNGICIDAL SPRAY & SEALANT USE GUIDE
  INEFFECTIVE MOLD PRODUCTS
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  MOLD PREVENTION AFTER FLOODING
  MOLD RESISTANT CONSTRUCTION
  SEPTIC SYSTEMS & FLOODS
  SEWAGE BACKUP, WHAT TO DO
  SEWAGE BACKUP TEST & CLEANUP
  SEWAGE BACKUP PREVENTION
  SEWAGE & SEPTIC CONTAMINANTS
  SEWAGE CONTAMINATION in buildings
  SEWAGE PATHOGENS in SEPTIC SLUDGE
  WHEN TO STOP LOOKING FOR MOLD
  Wind Damage to Roofs
FLOOD DAMAGE TO FOUNDATIONS
FLOODED HEATING EQUIPMENT REPAIR
FLOODED WATER HEATER REPAIR
FLOODED SEPTIC SYSTEMS, REPAIR
FLOODS IN buildings, MOLD PREVENTION
FLOOR & SUBFLOOR MOLD, HIDDEN
FLOOR TYPES & DEFECTS
FLOOR TILE ASBESTOS IDENTIFICATION
FLOOR TILE HISTORY & INGREDIENTS
FORMALDEHYDE HAZARDS
FOUNDATION WATERPROOFING
FRENCH DRAINS
FREEZE-PROOF A BUILDING
FROST HEAVES, FOUNDATION, SLAB

FUNGICIDAL SPRAY & SEALANT USE GUIDE

GASES, EXPOSURE, TESTING
  Carbon Dioxide - CO2
  Carbon Monoxide - CO
  METHANE GAS SOURCES
GAS MEASUREMENT TOOLS
Gas Toxicity Levels
HEATING OIL EXPOSURE HAZARDS, LIMITS
HEATING SYSTEM ODORS
House Dust Analysis
HOUSEWRAP AIR & VAPOR BARRIERS

HIDDEN MOLD, HOW TO FIND
HUMIDITY CONTROL TO PREVENT MOLD

INDOOR AIR QUALITY & HOUSE TIGHTNESS
INDOOR AIR QUALITY IMPROVEMENT GUIDE
INDOOR AIR QUALITY METHODS COMPARED

LEAD POISONING HAZARDS GUIDE
LEED GREEN BUILDING CERTIFICATION
LEED Building Designation & IAQ

MILDEW in buildings ?
MILDEW ERRORS - MOLD PHOTOS
MILDEW REMOVAL & PREVENTION

MOISTURE CONTROL in buildings

MOLD: A COMPLETE GUIDE TO MOLD
MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD
MOLD ACTIVITY in buildings
MOLD AGE - Old is the Mold?

MOLD APPEARANCE - WHAT MOLD LOOKS LIKE
MOLD APPEARANCE - STUFF THAT IS NOT MOLD
MOLD ATLAS & PARTICLES INDEX
MOLD BY MICROSCOPE
MOLD in the PETRI DISH, PHOTOS
Mold on Books, Book Conservation

MOLD CLASSES, HAZARD LEVELS
MOLD CLEANERS - WHAT TO USE
MOLD CLEANUP COMPANIES
MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD
MOLD CLEANUP by MEDIA BLASTING
MOLD CLEARANCE INSPECTIONS
MOLD CLINICAL REFERENCE TEXTS

MOLD DETECTION & INSPECTION GUIDE
MOLD DOCTORS - ENVIRONMENTAL MEDICINE

MOLD EXPERT, WHEN TO HIRE
MOLD EXPOSURE, FOOD HAZARDS
MOLD EXPOSURE RISK LEVELS
MOLD EXPOSURE STANDARDS

MOLD FAQ's
MOLD FREQUENCY in buildings
MOLD GROWTH on SURFACES

MOLD INSPECTORS & MOLD TESTERS
MOLD LEVEL REPORTS
MOLD LEVELS IN buildings

MOLD BY MICROSCOPE
MOLD in the PETRI DISH, PHOTOS

MOLD ODORS, MUSTY SMELLS
MOLD PREVENTION GUIDE

MOLD RELATED ILLNESS GUIDE
MOLD RELATED ILLNESS SYMPTOMS
MOLD RESISTANT CONSTRUCTION

MOLD SPRAYS, SEALANTS, PAINTS
MOLD STANDARDS

MOLD TEST KITS
MOLD TEST KITS for DIY MOLD TESTS
MOLD TEST METHODS, ACCURACY
MOLD TEST PROCEDURES
MOLD TEST REASONS
MOLD TESTING METHOD VALIDITY
MOLD TESTING SERVICES

MSDS Material Safety Data Sheets
MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE

Nanomaterials Hazards
NOISE / SOUND DIAGNOSIS & CURE

ODORS GASES SMELLS, DIAGNOSIS & CURE
RENTERS & TENANTS GUIDE TO MOLD

SAFETY HAZARDS GUIDE
SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR
SICK HOUSE IAQ QUESTIONNAIRE
SEWAGE BACKUP TEST & CLEANUP

STAIN DIAGNOSIS
STRUCTURAL INSPECTIONS & DEFECTS

TECHNICAL & LAB PROCEDURES
THERMAL TRACKING

More Information

Photo of a stairwell and entry floor of a home following demolition and cleaning for flood and mold damage (C) Daniel FriedmanMold Action Guide after Flooding: When is a Mold Cleanup Job Complete?
InspectAPedia®  -         

  • How to determine if a mold cleanup project has been completed properly
  • When & how to perform mold clearance inspections & tests
  • When can mold containment barriers be removed?
  • Who should conduct mold clearance testing: conflicts of interest
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

This chapter explains when you can (and probably should) stop looking for or testing for mold in a building after a mold cleanup has been attempted. We explain how you can be confident that the mold cleanup steps taken have been completely and properly performed. We explain when to order a post mold remediation clearance inspection and test, describe what should be done, and review other indicators that help you decide that a mold cleanup project has been completed after a building flood. Our photograph above shows the entry floor of a home at the completion of demolition, cleaning, disinfection, and treatment with a biocide sealant after the building was flooded.

If your building has been flooded, this website provides an easy to understand guide for flood damage assessment, setting priorities of action, safety, and we provide special information about avoiding or minimizing mold damage. These are quick, simple steps to minimize mold damage in a flooded building.

We also list after-flood "anti-mold" procedures that do not work or are unsafe - to help you avoid unnecessary expense in dealing with mold after a building flood. If your building is already moldy or if you suspect mold related illness in your building, we link to a step by step Mold Action Guide dealing with toxic or allergenic indoor mold and other indoor contaminants: when and how to inspect or test for mold, when to hire an expert, how to clean up a moldy area, when and how to perform post-remediation mold testing.

If your septic system has been flooded we link to an article outlining what to do about that system as well. Extensive, technically detailed in-depth articles on other mold detection, testing, and prevention methods are organized at our Mold Information Center.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

WHEN TO STOP LOOKING FOR MOLD After Cleaning and Repairing a Flooded Building

  • Mold Clearance Inspections: if significant costs were involved in demolition and cleaning to remove large areas of moldy materials (more than 30 sq.ft. of contiguous moldy stuff) from a building, before making final payment to the cleaning contractor, you should hire an independent expert to inspect and test (not just "test") the building for mold.

    The post mold remediation clearance inspector should examine
    the cleaned surfaces and will explore the un-treated areas to see if the demolition and cleaning were extensive enough.

    Screening tests for incomplete mold cleaning, remaining mold contamination, or cross-contamination of areas outside the work area may be performed to check for mold in building areas which were not included in the area of work, to be sure that they were not accidentally contaminated during the cleanup. Be sure that the post mold-remediation clearance inspection includes a thorough visual inspection. Simple screening tests for the presence or absence of mold are not reliable.

    Conflicts of interest: Be sure that your mold inspector has no financial relationship with and is completely independent from the cleaning contractor. This step should be taken after all demolition and cleaning have been performed and before any reconstruction has occurred. Otherwise it will be impossible to check the building cavities that were supposed to have been cleaned.

    Clearance Inspections are discussed in more detail in a separate document at Clearance Procedures

  • There should be no visible mold in the building.

  • All demolition and cleaning should have been completed before the mold clearance inspection is begun.

  • No moldy building contents should have been left in or stored in the building, and nothing that was removed from the building should have been returned unless it has been cleaned.

  • There should be no wet areas in the building, including no hidden wet areas in building cavities or behind floor baseboard or trim.

  • The building should not smell moldy.

  • Occupants returning to the building should not have an allergic or respiratory-distress or respiratory illness response that appears related to being inside the building. If this occurs, consult your doctor. People exposed to mold, allergens, and stress can become hyper sensitized to mold and other respiratory irritants.

  • Mold work area containment systems such as plastic barriers should be left in place until after a successful mold clearance inspection, including the lab work.

    Taking down mold containment barriers before the building has been cleared is a sign of a contractor in a rush. The risk is that if the cleanup was not adequate, you've now risked cross contamination of other building areas and contents - thus increasing the ultimate amount of mold cleanup work and cost.

    When a remediator removes their containment system before the mold clearance inspection we think that the contractor was in a rush, may have worried that we'd consider their containment practices unprofessional or inadequate, or the contractor may just be over-confident in their work.

Questions & Answers regarding this article

.

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Recommend / Share this Article            

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
  FIRST PRIORITIES
  BUILDING ENTRY PROCEDURE AFTER FLOODING
  DRINKING WATER - EMERGENCY PURIFICATION
  DRINKING WATER - EMERGENCY SOURCES
  ELECTRICAL SAFETY for Flood Damage Inspectors
  FLOOD DAMAGE TO FOUNDATIONS
  FLOOD RESPONSE CHECKLIST
  FLOOD DAMAGE RFERENCES
  FLOOD VENTS & FLOOD PORTS
  FLOOD-CAUSED MOLD, PREVENTION
  FLOODED HEATING EQUIPMENT REPAIR
  FLOODED WATER HEATER REPAIR
  FLOODED SEPTIC SYSTEMS, REPAIR
  FUNGICIDAL SPRAY & SEALANT USE GUIDE
  INEFFECTIVE MOLD PRODUCTS
  Mold in Fiberglass Insulation
  Mold on Books, Book Conservation
  Mold on Fiberboard Insulating Sheathing
  MOLD PREVENTION AFTER FLOODING
  MOLD RESISTANT CONSTRUCTION
  SEPTIC SYSTEMS & FLOODS
  SEWAGE BACKUP, WHAT TO DO
  SEWAGE BACKUP TEST & CLEANUP
  SEWAGE BACKUP PREVENTION
  SEWAGE & SEPTIC CONTAMINANTS
  SEWAGE CONTAMINATION in buildings
  SEWAGE PATHOGENS in SEPTIC SLUDGE
  WHEN TO STOP LOOKING FOR MOLD
  Wind Damage to Roofs

  • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. (727) 595-4211 mark@BestTampaInspector.com 11/06
  • Hankey and Brown home inspectors, Eden Prairie, MN, technical review by Roger Hankey, prior chairman, Standards Committee, American Society of Home Inspectors - ASHI. 952 829-0044 - hankeyandbrown.com 11/06
  • Arlene Puentes, a licensed home inspector, educator, and building failures researcher in Kingston, NY. 11/29/06
  • Repairing Your Flooded Home American Red Cross and FEMA - PDF - English
  • Como Reparar su Hogar Inundado American Red Cross and FEMA - PDF - espanol
  • Flood Cleanup - Avoiding Indoor Air Quality Problems US EPA Fact Sheet
  • Cleaning Up After a Flood Texas Department of State Health Services.

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • Environmental Health & Investigation Bibliography - our technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Adkins and Adkins Dictionary of Roman Religion discusses Robigus, the Roman god of crop protection and the legendary progenitor of wheat rust fungus.
  • Kansas State University, department of plant pathology, extension plant pathology web page on wheat rust fungus: see http://www.oznet.ksu.edu/path-ext/factSheets/Wheat/Wheat%20Leaf%20Rust.asp
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • US EPA - Mold Remediation in Schools and Commercial Building US EPA
  • US EPA - Una Breva Guia a Moho - Hongo - en Espanol

Allergies, Allergens, Allergy Testing in buildings - References & Products

  • Air Conditioning System Blower Fans & Filters Cascading for Optimum Indoor Air Quality
  • Allergen Tests in buildings advice about how to test, what to look for, in evaluating the level of dog, cat, or other animal allergens in a building
  • "IgG Food Allergy Testing by ELISA/EIA, What do they really tell us?" Sheryl B. Miller, MT (ASCP), PhD, Clinical Laboratory Director, Bastyr University Natural Health Clinic - ELISA testing accuracy: Here is an example of Miller's critique of ELISA http://www.betterhealthusa.com/public/282.cfm - Townsend Letter for Doctors and Patients
    The critique included in that article raises compelling questions about IgG testing assays, which prompts our interest in actually screening for the presence of high levels of particles that could carry allergens - dog dander or cat dander in the case at hand.
    http://www.tldp.com/issue/174/IgG%20Food%20Allergy.html contains similar criticism in another venue but interestingly by the same author, Sheryl Miller. Sheryl Miller, MT (ASCP), PhD, is an Immunologist and Associate Professor of Basic and Medical Sciences at Bastyr University in Bothell, Washington. She is also the Laboratory Director of the Bastyr Natural Health Clinic Laboratory.
  • Allergens: Testing for the level of exposure to animal allergens is discussed at http://www.animalhealthchannel.com/animalallergy/diagnosis.shtml (lab animal exposure study is interesting because it involves a higher exposure level in some cases
  • Allergens: WebMD discusses allergy tests for humans at webmd.com/allergies/allergy-tests
  • Animal Allergens: Dog, Cat, and Other Animal Dander - Cleanup & Prevention Information for Asthmatics and regarding Indoor Air Quality.
  • Atlas of Mold Related Illness Symptoms & Complaints - long list of both documented, studied mold related illness, and complaints ascribed to mold contamination or allergens in buildings
  • Cat Dander: how to inspect and test a building for past or current presence of cats, cat hair, cat dander, and cat allergens
  • Clinical Atlas of Mold Toxicity - An Online Description of Toxic, Pathogenic, Allergenic Fungi, Fungal Diseases
  • Fiberglass Insulation Contains Mold© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation
  • Humidity: What indoor humidity should we maintain in order to avoid a mold problem?
  • Mold Action Guide detailed guide on finding, removing, and preventing indoor mold contamination
  • Odors, Odor Detection, Smells, & Gases how to find and identify sources of noxious or toxic odors and gases
  • Other environmental risks, Our much longer list: Asbestos, carbon monoxide, electromagnetic fields, etc.
  • Ozone: The Use of Ozone Indoors for Control of Odors and Mold Removal in buildings: A Summary of Hazards and False Claims.
  • Pollen Allergens: identification, plant pollen and indoor air quality
  • Products to Reduce Mold & Allergy Problems to reduce indoor mold or allergen levels: air cleaners, air purifiers, dust mite covers, vacuum cleaners, crawl space vents
  • Recognizing Allergens: What various indoor allergens look like - identification photos to help identify pollen, dust mites, animal dander, toxic or allergenic mold - Common Mold and other Allergens, Irritants, Remedies & Advice
  • Rodent control issues, including dander, fecal, and urine contamination of buildings and Building insulation are discussed at our
  • Sewage and Septic backup contamination in buildings: inspection, testing, remediation, & references to expert sources
  • Action Guide: What to do about mold, mildew, and other indoor allergens
  • ...

Mold Contamination Testing, Cleanup, Prevention: references & products

  • GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminantsThe Mold Information Center: What to Do About Mold in buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
  • Aerobiology, Building Science, Microscopy, & Laboratory References, an extensive technical bibliography
  • Allergens: what they look like in buildings
  • Associations: Sick House, Sick Building, SBS - Air Quality, Government, Private Associations and Information Resources
  • Atlas of Clinical Fungi, 2nd Ed., GS deHoog, J Guarro, J Gene, & MJ Figueras, Centraalbureau voor Schimmelcultures, Universitat Rovira I Virgili, 2000, ISBN 90-70351-43-9 (you can buy this book at Amazon)
  • Atlas of Mold Related Illness: Index of Symptoms and health, physical, neurological, psychological, and other complaint which people suspect may be mold or building-related.
  • Atlas of Indoor Mold, Online Clinical Mold Atlas, Toxins, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • Black Mold that is Harmless Photos of recognizable, usually harmless black mold on wood, bluestain, ceratocystis, ophistoma
  • Building Floods: quick steps after a building flood or plumbing leak can prevent costly mold contamination
  • Classes of Mold: what types of cosmetic, allergenic, or toxic mold are a problem? Can mold be cleaned-up successfully?
  • Clinical Mold References - Detailed bibliography of mold reference texts
  • "A Brief Guide to Mold, Moisture, and Your Home", U.S. Environmental Protection Agency US EPA - includes basic advice for building owners, occupants, and mold cleanup operations. See http://www.epa.gov/mold/moldguide.htm
  • "Disease Prevention Program for Certain Vegetable Crops," David B. Langston, Jr., Extension Plant Pathologist - Vegetables, University of Georgia (PDF document) original source: www.reeis.usda.gov/web/crisprojectpages/209797.html
  • "Disease Prevention in Home Vegetable Gardens," Patricia Donald, Department of Plant Microbiology and Pathology, Lewis Jett
    Department of Horticulture, University of Missouri Extension - extension.missouri.edu/publications/DisplayPub.aspx?P=G6202
  • "Management of Powdery Mildew, Leveillula taurica, in Greenhouse Peppers," Ministry of Agriculture and Lands, British Columbia - Original source: www.agf.gov.bc.ca/cropprot/peppermildew.htm
  • Environmental Health & Investigation Bibliography - our own technical library on indoor air quality inspection, testing, laboratory procedures, forensic microscopy, etc.
  • Fiberglass: Mold in Fiberglass Insulation© 2005 comments about a field study in process, & more about health hazards from fiberglass insulation - DJF
  • Fifth Kingdom, Bryce Kendrick, ISBN13: 9781585100224, is available from the InspectAPedia online bookstore - we recommend the CD-ROM version of this book. This 3rd/edition is a compact but comprehensive encyclopedia of all things mycological. Every aspect of the fungi, from aflatoxin to zppspores, with an accessible blend of verve and wit. The 24 chapters are filled with up-to-date information of classification, yeast, lichens, spore dispersal, allergies, ecology, genetics, plant pathology, predatory fungi, biological control, mutualistic symbioses with animals and plants, fungi as food, food spoilage and mycotoxins.
  • Fungi, Identifying Filamentous, A Clinical Laboratory Handbook, Guy St-Germain, Richard Summerbell, Star Publishing, 1996, ISBN 0-89863-177-7 (English) (buy at Amazon)
  • Looking for Mold Procedure: what mold is often found where in buildings - simple technical presentation
  • Meruliporia: the house eating fungus or "poria"
  • Mold Action Guide: Step-by-Step Instructions, What to do about mold, mildew, and other indoor allergens
  • MOLD APPEARANCE - WHAT MOLD LOOKS LIKE Photos of what mold looks like in buildings
  • MOLD APPEARANCE - STUFF THAT IS NOT MOLD Photos of NOT-mold material that is sometimes mistaken for mold
  • MOLD ATLAS & PARTICLES INDEX, Pathogens, Allergens and Other Indoor Particles - Medical Health Effects of Mold (separate online document)
  • MOLD BY MICROSCOPE Mold under the microscope - photo identification of the most common indoor molds found in buildings
  • Mold FAQs Answers to Most Questions about Indoor Mold, Mold Related Illness, Mold Cleanup, Mold Prevention
  • US EPA: Mold Remediation in Schools and Commercial Building US EPA
  • Mold spores in the Home - a Photo ID Library for detection and identification of mold allergens
  • Mold Test Kits - How to Collect and Send Your Own Mold Sample to our mold testing lab or to any mold lab you wish
  • Most Common Indoor Molds Found in buildings, A Table of
  • Mycology, Fundamentals of Diagnostic, Fran Fisher, Norma B. Cook, W.B. Saunders Co. 1998, ISBN 0-7216-5006-6 (buy this book at Amazon)
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Rot concerns in buildings-some building mold such as Meruliporia incrassata "Poria" risks serious rot and hidden structural damage
  • US EPA: Una Breva Guia a Moho - Hongo - en Espanol

OTHER IAQ ISSUES: How To Find and Address Other Indoor Air or Indoor Environment Contaminants Besides Mold

Mold or allergens may not be the only or even the main indoor environmental contaminant. Don't let media attention to mold cause so much enviro-scare fear that other, possibly more urgent hazards go un-addressed.

  • Fiberglass building insulation and HVAC duct work insulation hazards
  • Sewage and Septic backup contamination in buildings: inspection, testing, remediation, & references to expert sources
  • Other environmental risks: Asbestos, carbon monoxide, electromagnetic fields, environmental illness, fiberglass, MCS - multiple chemical sensitivity, toxic gases, etc
  • Indoor Gas Sampling Plan for Residential buildings lists a number of toxic indoor gases which we test for, depending on the building complaint and building conditions
  • Ozone Warnings - Use of Ozone as a "mold" remedy is ineffective and may be dangerous.
  • Pet control - if you can't say goodbye to your bird, cat, dog, guinea pig, hamster, tropical fish, then limit the areas they occupy and limit the airflow from that area to sleeping or other areas of the building, use allergenic bedding, eliminate wall-to-wall carpeting, improve housecleaning including use of a HEPA-rated vacuum cleaner. For more details see our article Dog, Cat, and Other Animal Dander - Information for Asthmatics and Indoor Air Quality
  • Rodents, Mice, Squirrel Control - I find high levels of mouse and rodent dander, fecal dust, and urine-contaminated dust in some buildings, and high levels of these materials in building insulation in those locations. If you have a mouse problem, particularly if mice and their waste (fecals or urine) are contaminating the building HVAC or building insulation, may need both steps to clean up or remove infected materials and steps to stop an ongoing rodent problem. If squirrels are a problem, the cleanup needs to include closing off entry openings into the building. Get some help from a licensed pest control expert.
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com