Mobile View ENERGY SAVINGS in BUILDINGS ENVIRONMENTAL HAZARDS GUIDE AIR POLLUTANTS, COMMON INDOOR ALLERGEN TESTS for BUILDINGS ALLERGY TESTS for PEOPLE ALLERGY TEST ACCURACY FLOODS IN BUILDINGS-priorities FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP MOLD: A COMPLETE GUIDE TO MOLD MOLD INFORMATION CENTER ACCURACY OF VARIOUS MOLD TEST METHODS ACTION GUIDE - WHAT TO DO ABOUT INDOOR MOLD ALLERGEN TESTS for BUILDINGS ALLERGY TESTS for PEOPLE ALLERGY TEST ACCURACY CLEARANCE INSPECTIONS - MOLD CLEANUP DO IT YOURSELF MOLD CLEANUP ENERGY SAVINGS in BUILDINGS ENERGY SAVINGS PRIORITIES ENERGY SAVINGS RETROFIT CASE STUDY ENERGY SAVINGS RETROFIT LEAK SEALING GUIDE ENERGY SAVINGS RETROFIT OPTIONS FUNGICIDAL SPRAY & SEALANT USE GUIDE INDOOR AIR QUALITY & HOUSE TIGHTNESS INDOOR AIR QUALITY IMPROVEMENT GUIDE INDOOR AIR QUALITY METHODS COMPARED LEAD POISONING HAZARDS GUIDE MILDEW in BUILDINGS ? MILDEW ERRORS - MOLD PHOTOS MILDEW REMOVAL & PREVENTION MOISTURE CONTROL in BUILDINGS MOLD: A COMPLETE GUIDE TO MOLD MOLD ACTION GUIDE - WHAT TO DO ABOUT MOLD MOLD AGE - Old is the Mold? MOLD APPEARANCE - WHAT MOLD LOOKS LIKE MOLD APPEARANCE - STUFF THAT IS NOT MOLD MOLD ATLAS & PARTICLES INDEX MOLD BY MICROSCOPE MOLD CLASSES, HAZARD LEVELS MOLD CLEANERS - WHAT TO USE MOLD CLEANUP COMPANIES MOLD CLEANUP GUIDE- HOW TO GET RID OF MOLD MOLD REMEDIATION CLEARANCE INSPECTION MOLD DETECTION & INSPECTION GUIDE MOLD DOCTOR? MOLD EXPERT, WHEN TO HIRE MOLD EXPOSURE RISK LEVELS L1: Very-Low Mold Risk L2: Low Mold Risk L3: High Mold Risk L4: Contaminated MOLD EXPOSURE STANDARDS MOLD CONTAMINATION LEVELS MOLD CULTURES AIRBORNE MOLD SPORE COUNTS MOLD CONTAMINATION LEVELS MOLD TOXICITY VARIATION MOLD PARTICLE TOXICITY VIABLE vs NON-VIABLE MOLD SPORES MOLD STANDARDS - GOVERNMENT MOLD STANDARDS - WORLD WIDE Australian Mould Guidelines California Mold Disclosure Law Canadian Mould Guidelines Canadian National Toxic Mold Centre New York City Mold Guidelines World Health Organization Mold Bulletin MYCOTOXIN EFFECTS of MOLD EXPOSURE MOLD CONTAMINATION LEVELS, SPECIFIC STACHYBOTRYS CHARTARUM TOXICITY PENICILLIUM SP TOXICITY ASPERGILLUS SP TOXICITY also see ACCEPTABLE MOLD LEVEL MOLD INSPECTORS & MOLD TESTERS MOLD LEVEL IN AIR, VALIDITY MOLD LEVEL REPORTS ACCEPTABLE MOLD LEVEL ACCURACY OF AIRBORNE MOLD SPORE COUNTS MOLD CLASSES, HAZARD LEVELS MOLD CULTURE PLATE TEST ERRORS MOLD LEVEL IN AIR, VALIDITY MOLD LEVELS on SURFACES MOLD LEVELS IN BUILDINGS MOLD by MICROSCOPE MOLD ODORS, MUSTY SMELLS MOLD PREVENTION GUIDE MOLD RELATED ILLNESS GUIDE MOLD RELATED ILLNESS SYMPTOMS MOLD SPRAYS, SEALANTS, PAINTS MOLD STANDARDS MOLD TEST KITS MOLD TEST KITS for DIY MOLD TESTS MOLD TEST PROCEDURES MOLD TEST REASONS MOLD TESTING METHOD VALIDITY MOLD TESTING SERVICES ODORS, Smells, Gases in Buildings-Diagnosis & Cure RENTERS & TENANTS GUIDE TO MOLD SEWAGE BACKUP TEST & CLEANUP STAIN DIAGNOSIS TECHNICAL & LAB PROCEDURES THERMAL TRACKING More Information InspectAPedia® Home & Site Map Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Privacy Policies Contact Us |
Mold Exposure Standards:Levels of allergenic or toxic mold & how much mold means a problem?
|
![]() |
![]() |
![]() |
This page will automatically forward to the new location for this document at InspectAPedia.com, located at
http://InspectAPedia.com/sickhouse/Mold_Standards.htm.
If you do not see the new page in a few seconds, use this link to Mold_Standards.htm.
Warning: fungal spore counts in indoor air, whether "viable" or "non-viable" counts, as well as swab and culture methods to identify just what mold is present in a building are questionable methods to characterize the presence or absence of a mold problem indoors.
From experience carefully inspecting many buildings for mold problems and simultaneously collecting many types of field samples and examining them in our lab, our view is that anyone who makes one or a few indoor air measurements or relies on culture plates or swabs to "characterize" the mold level and mold species in a building is risking being way off target, particularly if the "test results" show low numbers.
This document provides information about airborne mold spore counts, surface density, and other measures of the exposure level of allergenic, infectious, and levels of toxic mold in residential buildings: At what level is allergenic or toxic mold considered a problem in buildings? How do we obtain an accurate and meaningful measurement of mold exposure indoors?
© Copyright 2010 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
"Mold Levels" warning: single number "mold levels" are unreliable as a measure of health risk in buildings for several reasons including at least the following:
See ACCURACY OF AIRBORNE MOLD SPORE COUNTS for more details about these issues. That said, here is a sampling of some indoor air mold spore exposure level criteria and comments
1. Baxter et als: Mold contamination is considered present in a building when the total mold spore concentration per cubic meter is above 10,000. Our own field and lab experience confirms this view. However in special cases, even low quantitative levels of certain particles or particle types (such as Pen/Asp spore chains in an un-treated building) may be diagnostic and may indicate a hidden mold reservoir that at least merits further investigation.
2. The National Allergy Bureau, reporting the NAB SCALE (National Allergy Bureau) of mold and pollen counts, considers mold counts in outdoor air of 0-6499 spores per cubic meter of air as low, to 6500 to 12,999 spores per cubic meter of air as moderate, to 13,000 to 49,999 spores per cubic meter of air as high, and above 50,000 as very high. At "high" levels most individuals with any sensitivity will experience
symptoms. AAAAI also provides absent, low, moderate, high, and very-high level level definitions for grass, tree, and weed pollen grains counted per cubic meter of outdoor air.
Acceptable levels for individual species vary since species toxicity varies widely as does spore size, weight, and other features which affect risk
to building occupants. E.g. Aspergillus/Penicillium in a "clean" residential building study was at a mean of 230, in buildings known to have a
moisture or flooding problem it was at 2235 and in mold contaminated buildings the figure was 36,037.
AAAAI provides an important qualification about mold and pollen counts as reported by that agency which we quote just below:
"These mold levels were determined based on outdoor exposure to natural occurring spores in the environment and should not be applied to indoor exposure which may represent an entirely different spectrum of spore types.
These definitions would allow comparison between sites across the country. They are based on ecological measurements, not health effects. However, assuming dose/response relationships are the same across the country, the definitions are probably more appropriate than a definition based on local numbers. This does mean that, for some stations, some categories will never be high." - AAAAI.
3. The University of Minnesota data presents this table for mold levels expressed in colony forming units per gram. WARNING: mold spores may be not viable (dead), wrong culture media may be used, or one species can overgrow another, etc. - so don't produce any colonies, but may be toxic if inhaled (such as some species of Penicillium). So we would not rely on culture data. But here it is:
WARNING: about interpreting mold cultures: this is a very very inaccurate method for screening buildings for the level of mold contamination for many reasons, including that only 10% of all molds will grow on any culture under any condition. So this approach begins as 90% "wrong".
Other mold level variables include the differences in settlement rate out of air as a function of particle size and weight, proximity to a mold contamination reservoir, and the problem that a serious toxic mold may be overgrown (if it grows at all) in the culture by a second mold species which hides the first one. See INDOOR AIR QUALITY METHODS COMPARED for details of these issues.
4.The American Conference of Government Industrial Hygienists (ACGIH) stated (Harriet Burge et. al) stated in 1987 that indoor mold levels are generally less than 1/3 the outdoor level and that when indoor mold is at more than this level remedial action should betaken to find the source of the elevated counts and to clean it up.
WARNING: this is an inaccurate and unreliable method for screening buildings for mold for many reasons, including:
See INDOOR AIR QUALITY METHODS COMPARED for details of these issues.
5. Other proposals for Mold Exposure Standards have included a limit of 500 CFU/ of mold spores per cubic meter of air in winter indoors in sub arctic climates (Reponen et al.1990). CFU means "colony forming units" of mold.
We suspect that focusing only on "colony-forming-units" (that is, viable mold that will grow) is not a very reliable way to check out a building. That's because
At MOLD CULTURE PLATE TEST ERRORS we have cited the range of errors and limitations of using cultures to check for viable mold, and we point out that depending on the particular mold genera and species present in a building, even non-viable mold may be allergenic or toxic. That is why experts in mold testing and remediation advise that the object is to remove mold or clean up mold in a moldy indoor environment, rather than attempting to "kill" mold indoors.
Also see INDOOR AIR QUALITY METHODS COMPARED for details of these issues.
Single number "mold levels" are very unreliable as a measure of health risk in buildings for several reasons including at least the following:
Particle levels vary widely over short time periods: The actual level of indoor particles in air varies by several orders of magnitude over very short few-minute intervals, making reliance on any single measurement questionable, particularly if the measurement does not show evidence of a problem.
The absolute level of airborne particles in buildings varies enormously, possibly by a factor of hundreds to thousands, over intervals as short as a few minutes. Simple mechanical disturbance like turning on or off a fan can completely change individual measurement results. Short term measurements are therefore inaccurate and even longer term measurements are inaccurate if they do not consider the in-use variations in dust disturbance in a building.
Human sensitivity to mold varies: Individual susceptibility to mold/mycotoxin/aflatoxin-related or allergy-related illness varies widely and human exposure is complex because people move among a variety of environments
Finally, because of wide variation in individual human reaction and risk to mold, variation in allergenicity, pathogenicity, and toxicity among mold genera and individual species, and even additional variation in these levels depending on specific environmental conditions such as the substrate upon which a mold is growing (its food), quantitative risk-levels are better used as an overall indication of building cleanliness before and after a mold cleanup, and not as an absolute level of risk to building occupants.
There is very wide variance among the toxicity of individual mold species, ranging from none to probably highly toxic, pathogenic, or even carcinogenic
Mold Spore size varies widely from less than 1 u to over 200u, so a large spore contains potentially more harmful material than a small spore of the same "toxicity," making a "count" that does not identify the particle and particle size ambiguous
Mold spore toxicity may vary, even within an individual species, depending on what substrate the species is growing on in a particular instance, e.g. wood vs. drywall.
These mold spores vary in significance: procedures that use cultures to identify "viable" spores may omit high levels of non-viable spores which nonetheless remain highly toxic. Methods that rely on culturing have a high risk of identifying a mold which is present but is not the dominant or even the most problematic mold in the building. For more details see Mold Spore Counts: are indoor fungal spore counts valid? for further explanation.
For the standards and references below, numbers are spores per cubic meter of air and do not consider individual or viable/non-viable or genera-species specific levels. There is a serious limitation of the standards since the spores of different genera and species vary widely in total size, mass, and toxicity.
The level of airborne particles indoors varies enormously, by orders of magnitude, from moment to moment, making the strict interpretation of any "indoor air mold test" unreliable, as we discuss at ACCURACY OF AIRBORNE MOLD SPORE COUNTS. -DF
Note: Previous data provided at this web article had been obtained from a presentation by J.R. Tucker, EMS-sales, who presented data at the NC/SC Environmental Information Association 2005 Conference, Myrtle Beach, SC citing mold exposure standards from Brazil, mold exposure standards for Czechoslovakia, Mold exposure guidelines for Finland, Mold exposure standards set by the Nordic Council, mold standards cited by the World Health Organization WHO, and mold exposure standards for the Netherlands and lastly, mold exposure standards for Poland. Those figures were quoted in this article from the material provided at that conference. Mold exposure standard numbers were expressed spores per cubic meter of air and did not consider individual or viable/non-viable or genera-species specific levels. We have removed those data points at the request of Dr. Robert Brandys who informed us that he was and remains the original author.
Mycotoxins are produced by some common molds found in buildings, including Aspergillus, Penicillium, Fusarium, Stachybotrys, and even Alternaria. Common classification groups of mycotoxins include aflatoxins, fumonisins, trichothecens, and ergot alkaloids. Arora has pointed out that the following conditions are necessary for mycotoxins to affect humans:
Given even these stringent criteria, field investigations of moldy buildings that we have conducted from 1986 to present, included both human building occupants and in some cases pets who appeared exhibit complaints or symptoms consistent with mycotoxin exposure. Some of these clients and their physicians confirmed that exposure by appropriate medical tests.
A fellow aerobiologist who also has experience raising sheep, Larry Syzdek (PAAA member) informed us of a mold-related illness well known to occur in sheep which Syzdek explained has occurred in his experience in sheep exposed to moldy straw, called in lay terms, "sheep circling disease" (Listeriosis, however Listeria moncytogenes is the specific bacterium - not a mold - known to cause listeriosis, a disease which can affect both other animals and also humans, particularly pregnant women who are 20 times more likely than other healthy adults to get listeriosis).
The author of this web article, (Friedman) has described field observations of dogs appearing to exhibit strange behavior (running in circles, falling down, disorientation, and occasional uncharacteristic aggressive behavior, and in one case, fatal internal bleeding after severe exposure to S. chartarum during a building demolition. These animals were pets of clients whose homes were severely mold-contaminated. With Syzdek, we have speculated on the possibility that other animals than sheep may be similar affected by exposure to some indoor molds and may be exhibiting behavior similar to that caused by Listgeriosis though the etiology of this disease is suspected to be different.
These hypothetical remarks presented here intend to solicit additional field reports and data, possibly in support of future controlled studies. Readers should not assume that we have drawn conclusions from the suggestive anecdotal data currently at hand.
Some species specific acceptable levels have been addressed and vary considerably by species, environmental conditions, and proponent.
REFERENCE:A number of resources cited here are reviewed more carefully in "Comparisons of seasonal fungal prevalence in indoor and outdoor air and in house dusts of dwellings in one Northeast American County," Ping Ren,
Thomas M. Jaunkun and Brian P. Leaderer, Division of Environmental Health Sciences, Department of Epidemiology and Public Health, Yale University School
of Medicine, New Haven Ct. and appearing in the Journal of Exposure Analysis and Environmental Epidemiology (1999) 9, 560-568.
http://www.stockton-press.co.uk
See references below for important additional information such as mold testing, cleanup and mold remediation guideline resources.
According to A.S. Arora: Stachybotrys chartarum strain s72 contains 1.0x10-4 nanograms of satratoxin H per spore. 10 billion spores of s72 S. chartarum must be present in a single cubic meter of air to produce one milligram of satratoxin H per meter of air. Dr. Arora continues: "... it was calculated that a no-effect dose [in rats] corresponds to a 24-hour exposure to 3 billion spores per cubic meter of air for an infant [human], 9.5 billions spores per meter for school-age children, and 22 billion spores per cubic meter for adults."
Dr. Arora did not expand his discussion to address any potential cumulative toxicity of longer term exposure to lower levels of mycotoxins in buildings.
This "toxic black mold," Stachybotrys chartarum, infamous thanks to media attention, is not designed for airborne transmission, being large and sticky.
Indeed we often find S. chartarum mold spores present in air samples when a dense colony of such mold is being mechanically disturbed, such as during demolition. But we have never seen it in air anywhere close to the levels cited as the "no-effect dose." We believe that we've been barking up the wrong mold-tree, and that one would be smarter to look in buildings for the Penicillium and Aspergillus families which spread throughout a building easily by airborne transmission
REFERENCE: Content of this section paraphrased and others quoted from a guest column, "Understanding the Health Effects of Mold," by Dr. Ajit S. Arora, MD, PhD, appearing in AIHA's magazine "The Synergist," September 2003, in the AIH Diplomate section, Pages vi-vii. Dr. Arora is a forensic medical examiner and medical toxicologist in Los Angeles. see partheniamedical.com.
"Clean" residential buildings are typically 230/m3 +/- 630.
Buildings with evidence of flooding are typically much higher: 2200/m3 and
mold-damaged buildings are typically extremely high in comparison: 36,000/m3.
We usually find only trace levels of Penicillium/Aspergillus indoors in residential buildings and offices, so counts even close to the "clean" level may make further investigation a reasonable course of action, particularly where the building houses occupants have complaints possibly due to mold, or occupants who may be at extra risk.
Holmberg (1987) associated Aspergillus spore levels over 50 CFU / cubic meter with sick building syndrome. We comment elsewhere that depending on culturing mold in buildings is unreliable since toxic or allergenic particles may be present but may be of a species or genera which either does not grow on a culture medium, or which is overgrown by something else on the medium.
Further, relying on settlement plates to culture mold produces quantitatively skewed results since different particles settle out of air at different rates, confounding an estimate of their numbers. Anderson™ multi-stage samplers which develop culturable samples attempt to overcome the particle size problem.(C)Trap DJ Friedman
Aspergillus sp. may be the most common and serious airborne mold problems in buildings: Opinion: from the author (DJ Friedman) based on extensive field investigations and laboratory work, we suspect that several species of Aspergillus are probably the most common and widespread problem mold found indoors in buildings. These spores are small, easily airborne, grow on a variety of surface materials, and move readily throughout a building almost like a gas (due to their small size) riding on building convection currents and remaining airborne for long periods of time.
...
|
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
MOLD LEVELS IN BUILDINGS
MOLD CONTAMINATION LEVELS
MOLD CULTURES
AIRBORNE SPORES
CONTAMINATION LEVELS
TOXICITY VARIATION
PARTICLE TOXICITY
VIABLE vs NON-VIABLE
GOVERNMENT STANDARDS
WORLDWIDE STANDARDS
MYCOTOXIN EFFECTS
SPECIFIC MOLDS
STACHYBOTRYS CHARTARUM
PENICILLIUM SP
ASPERGILLUS SP
also see ACCEPTABLE MOLD LEVEL
MOLD EXPOSURE RISK LEVELS
L1: Very-Low Mold Risk
L2: Low Mold Risk
L3: High Mold Risk
L4: Contaminated
|
|
![]() The Mold Information Center: What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems |
![]() Use this simple, economical mold test kit by following our instructions on how to collect and mail mold samples to our lab |
Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
|
![]() Building Inspection, Problem Diagnosis, Forensic Investigation & Testing, Repair Consulting |
|
|
02/08/2010 - 01/15/1997 - InspectAPedia.com/sickhouse/moldlevels.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark