| InspectAPedia® |
InspectAPedia
| |
Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair | Ask a Question or Search InspectAPedia |
Mobile ViewSTRUCTURAL INSPECTIONS & DEFECTS ADVANCED INSPECTION METHODS AGE of a BUILDING - how to determine ARCHITECTURE, STYLE, & Building Age Building Records Chimneys & Fireplaces, Age, Types Electrical Components, Age, Types FLOORING MATERIALS, Age, Types FOUNDATION INSULATION OPTIONS FOUNDATION MATERIALS, Age, Types FRAMING MATERIALS, Age, Types FRAMING METHODS, Age, Types FRAMING SIZE & Spacing, Age, Types FRAMING TABLES, SPANS for DECKS Heating Equipment, Age, Types Historic Homes, Home Improvement Costs, Research Insulation Materials, Age, Types Nails and Hardware, Age, Types PLASTER & BEAVERBOARD & DRYWALL PLASTER BULGES & PILLOWS PLASTER LATH, METAL PLASTER, LOOSE FALL HAZARDS PLASTER TYPE IDENTIFICATION Plumbing Materials & Fixtures, Age, Types ROOFING MATERIALS, Age, Types Saw Cuts, Tool Marks, Age of Sears Kit Houses SIDING MATERIALS, Age, Types WINDOWS & DOORS, Age, Types AIR CONDITIONING & HEAT PUMP SYSTEMS AGE of AIR CONDITIONERS & HEAT PUMPS ARCHITECTURE & BUILDING COMPONENT ID Architectural Styles - Illustrated Guide Architecture Dictionary of Buildings, Components Building Age & Architectural Style Chimney Architectural Styles - Photo Guide KIT HOMES, Aladdin, Sears, Wards, Others Mobile Homes, Modulars, Panelized, & Factory-Built Roofs & Architectural Styles - Photo Guide Roof Dormer Types - Photo Guide Siding, Sheathing Identification - Photo Guide Window Types - Photo Guide ASBESTOS FLOORING HAZARD REDUCTION ASBESTOS-FREE INSULATION MATERIALS ASBESTOS IDENTIFICATION IN BUILDINGS ASBESTOS ROOFING / SIDING DUST ATTIC LEAKS, CONDENSATION & MOLD BEST CONSTRUCTION PRACTICES GUIDE BRICK FOUNDATIONS & WALLS BRICK STRUCTURAL WALL Loose Bulged Brick Thermal Expansion Cracking BRICK VENEER WALL Loose, Bulged BRICK WALL DRAINAGE WEEP HOLES BUCKLED FOUNDATIONS due to INSULATION? BUILDING SAFETY HAZARDS GUIDE BUILDING SETTLEMENT CESSPOOL AGE ESTIMATION CHIMNEY INSPECTION DIAGNOSIS & REPAIR COLUMNS & POSTS, DEFECTS CONCRETE FOUNDATIONS CONCRETE FOUNDATIONS, PRE-CAST Cracks, Checking or Splitting Beams & Log Homes CRAWL SPACES DECK & PORCH CONSTRUCTION Deck Construction Best Practices DECK COLLAPSE Case Study DECK FINISHES COATINGS PRESERVATIVES DECK FLASHING LEAKS, ROT Case Study DECKS, ROOFTOP CONSTRUCTION DEBRIS STAINING on ROOFS DEFINITIONS of Mobile Home, Doublewide, Modular, Panelized DEFINITIONS of ENGINEERED WOOD OSB LVL etc EARTHQUAKE DAMAGED FOUNDATIONS ELECTRICAL INSPECTION, DIAGNOSIS, REPAIR KNOB & TUBE WIRING ENERGY SAVINGS in BUILDINGS EXTERIORS of BUILDINGS FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP FLOODS IN BUILDINGS-mold FLOOR, ENGINEERED WOOD & LAMINATES FLOOR FRAMING & SUBFLOOR for TILE FLOOR TYPES & DEFECTS FLOOR TILE ASBESTOS IDENTIFICATION FLOOR TILE HISTORY & INGREDIENTS FOOTING & FOUNDATION DRAINS FOOTINGS EXPOSED, Repair Methods FOUNDATION BULGE or LEAN MEASUREMENTS FOUNDATION CONSTRUCTION TYPES FOUNDATION CONTRACTORS, ENGINEERS FOUNDATION CRACKS & DAMAGE GUIDE FOUNDATION FAILURES by TYPE & MATERIAL FOUNDATION FAILURES by MOVEMENT TYPE FOUNDATION INSPECTION METHODS FOUNDATION INSULATION OPTIONS FOUNDATION MATERIALS, Age, Types FOUNDATION REPAIR METHODS FOUNDATION WATERPROOFING FRAMING DAMAGE, INSPECTION, REPAIR FRAMING DETAILS for BETTER INSULATION FRAMING DETAILS for DOUBLE WALL HOUSES FRAMING CONNECTORS & JOIST HANGERS FRAMING FASTENERS, NAILS, SCREWS, & HIDDEN FRAMING & SUBFLOOR for TILE FRAMING MATERIALS, Age, Types FRAMING METAL STUD PERFORMANCE FRAMING METHODS, Age, Types KIT HOMES, Aladdin, Sears, Wards, Others Log Home Construction Modular Construction Panelized Construction Plank Houses Platform Framing Post & Beam Construction Pre-Cut Lumber Construction Sears Kit Houses STRAW BALE CONSTRUCTION TRUSSES, Floor & Roof Welded Wire Sandwich Framing FRAMING SIZE & Spacing, Age, Types FRAMING TABLES, SPANS for DECKS FRENCH DRAINS FROST HEAVES, FOUNDATION, SLAB FRT PLYWOOD GALVANIC SCALE & METAL CORROSION GLUES ADHESIVES, EXTERIOR CONSTRUCTION GRADING & SITE WORK, EXTERIOR GUTTERS & DOWNSPOUTS HEATING SYSTEMS HOUSE PARTS, DEFINITIONS HOUSEWRAP INSTALLATION DETAILS I-JOISTS, Wood Roof Floor KIT HOMES, Aladdin, Sears, Wards, Others ALADDIN KIT HOUSES SEARS KIT HOUSES LEED GREEN BUILDING CERTIFICATION LOG HOME GUIDE LVL Laminated Veneer Lumber, Beams MOBILE HOMES, DOUBLEWIDES, TRAILERS MODULAR HOME CONSTRUCTION MOISTURE CONTROL in BUILDINGS NOISE / SOUND DIAGNOSIS & CURE OSB - Oriented Strand Board PANELIZED CONSTRUCTION PLASTER BULGES & PILLOWS PLASTER, LOOSE FALL HAZARDS PLUMBING SYSTEM INSPECT DIAGNOSE REPAIR PLYWOOD Roof, Wall, Floor Decks & Sheathing PORCH CONSTRUCTION & SCREENING PRE-CUT & KIT HOMES Preservative-Treated Framing Lumber ROOFING INSPECTION & REPAIR ROT, FUNGUS, TERMITES ROT, TIMBER FRAME SEARS KIT HOUSES How to Identify Sears Kit Houses The Sears Catalog House - Photos Sears Catalog Home Exterior details Sears Catalog Home Interior details Sears Mail Order Lumber Stencil Marks How wear and tear affect a Sears Home Sears House Identification Points Confusion in Sears House Identification Are these Sears catalog homes? Books on Sears and other Kit or Catalog Houses KIT HOMES, Aladdin, Sears, Wards, Others ALADDIN KIT HOUSES SEPTIC SYSTEM INSPECT DIAGNOSE REPAIR SEPTIC LIFE EXPECTANCY CESSPOOL AGE ESTIMATION SHEATHING, Gypsum board SHEATHING Homasote & Other Board SHEATHING, OSB SHEATHING, Plywood SHEATHING, FOIL FACED - VENTS SIDING, Sheathing Identification - Photo Guide SINKHOLES, WARNING SIGNS SINKING BUILDINGS SLAB CRACK EVALUATION SLAB CRACK REPAIR Splits in Structural Wood Beams STAIN & BIODETERIORATION AGENT CATALOG STAINS on BUILDINGS - QUICK GUIDE STAIN DIAGNOSIS on BUILDING EXTERIORS STAIRS, RAILINGS, LANDINGS, RAMPS STONE CLEANING METHODS STONE FOUNDATIONS STONE VENEER WALLS STRAW BALE CONSTRUCTION STRESS SKIN INSULATED PANELS STRUCTURAL INSPECTIONS & DEFECTS STUCCO WAll FAILURES DUE TO WEATHER STUCCO WALL METHODS & INSTALLATION STUCCO OVER FOAM INSULATION STUCCO PAINT FAILURES SWEATING (CONDENSATION) on PIPES, TANKS TERMITES, ROT THERMAL EXPANSION of MATERIALS THERMAL MASS in BUILDINGS TRUSS UPLIFT, ROOF TRUSSES, Floor & Roof VAPOR BARRIERS & CONDENSATION in BUILDINGS VENTILATION in buildings VINYL Siding or PLASTIC Window ODORS in buildings VINYL CHLORIDE HEALTH INFO WATER BARRIERS, EXTERIOR BUILDING WATER ENTRY in BUILDINGS WATER HEATERS WATER PUMPS & TANKS WIND ENERGY SYSTEMS WIND TURBINES & LIGHTNING WINDOWS & DOORS, Age, Types WINTERIZE A BUILDING WOOD FOUNDATIONS More Information |
Aladdin kit homes: detailed photographic and historic clues to assist in the identification & restoration of Aladdin Catalog or Aladdin Kit homes and including references to other expert books and resources on catalog or kit homes in the United States. InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.Our page top photo of an Aladdin kit house, an Edison model, is provided courtesy of museum curator Melodie Nichols. The front porch, originally an open design, has been enclosed. © Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website. For more extensive references on identifying and determining the age of buildings see Find the Age of a House How to Determine the Age of a Building from Visual Clues, Architectural Style, Building Materials, Construction Details, or Documentary Clues Also see Brick Lined Wall Cavities - determining the age of older homes by bricks in wall cavities. Photo Guide to Identifying Aladdin Kit Houses
Also see Sterling Kit Homes and Lewis Liberty Kit Homes below. By 1910 the company's spring Aladdin Houses catalog advertised that they had already been in the lumber business for 19 years as the North American Construction Company in Bay City. [1] The company described the product as "The original and only perfect system for the construction of knocked down houses" and further pointed out that by using mill-run lengths of No. 1 Huron Pine lumber throughout, their house design made unnecessary the cutting and waste of good lumber, reducing lumber waste to less than two percent. North American also provided this encouragement to would-be knocked-down kit home builder-owners: [1]
The companies we list above eventually merged. 35 models of Aladdin knocked-down houses or kit homes were available in 1949 and over 75,000 Aladdin kit homes were sold. By the 1960's delivery of these kit homes shifted from rail to truck delivery, which may mean that there will be more homes of this vintage and later built further from rail stations.
[Aladdin kit home photos wanted, CONTACT us] The National Trust Library offers catalogs of these Aladdin kit houses.
According to the Clarke Historical Library:
Aladdin knocked-down house kit homes were sold for cash with a fifty-percent downpayment at the time of order and the remaining balance due cash on delivery of the home. "This is an invariable rule and is no tmeant to be a reflection on your financial standing. We absolutely will not sell houses on any other except a strictly cash vasis. All prices subject to advance in price of lumber. Discount of 5 percent allowed for full amount of cash with order." [1] Tips for Identifying an Aladdin Kit House
Photo Examples of Aladdin Kit Houses
An Aladdin House at a Glance - What You Get
Aladdin Knocked-down Houses as kit homes produdced by the North American Construction Company advertised that
From the 1910 Aladdin Kit House catalog we note the company's list of just what was provided with each "knocked-down" kit home: [2]
The lumber used in Aladdin homes was described by North American:Every piece of lumber in every Aladdin house has been carefully selected from the highest graade of Huron Pine. Clear yellow pine is used for all inside finish. It is carefully inspected by experienced men and if not up to a high standard is not used. This is an extremely important point and you should consider it carefully. Our facilities for buying high grades are unequaled by any manufacturer of lumber in the country. This means much to the purchaser - to know the quality of materials used - to know that the lumber and timber are the best; that it is well seasoned; sound and of first quality throughout. And nowhere in the world is there better pine to be found than in the great stat of Michigan. All the interior finish, doors, etc. is put through three separate sanding macines, m aking a beautiful finish. Aladdin Plaster BoardAladdin plaster board is the greatest single achievement in the builders' craft in the last generation. Aladdin plaster board makes a perfect wall; it is easily and quickly put on; its remarkable construction gives protection against extremes in weather; it is positively fireproof; it deadens sound. In actual, carefully conducted comparative tests a house lined with Aladdin plaster board required 18 per cent less coal to keep it at a temperature of 70 degrees than a house of identical size and construction, but with the usual lath and plaster inside walls. The above test gave definite proof of the superiority of Aladdin plaster board over lath and plaster. Aladdin plaster board is comprosed of four layers of wool felt and three thicknesses of the very best close grain plaster. It is manufactured under enormous pressure and the result is a perfect board, stiff, strong, and smooth. It will not crack with age nor loosen from dampness as will the ordinary plaster. It comes in sheets 32 x 36 inches in size and is nailed directly to the studding. The plaster alone in Aladdin plaster board is equal in warmth to ordinary plaster, while the four layers of wool felt are more than equal in protection to inch lumber sheathing and building paper combined. You paper directly onto the plaster board. We also furnish a special Plasto-filler, which when mixed with water is used to fill all joints of the plaster board, giving a smooth, perfect wall. Tivoli New York Aladdin Kit Home Renovation Exposes Construction Details, Markings, History
In 2010 the owners of this Aladdin home began a major renovation that led to gutting the building's interior, exposing the original Aladdin kit home stencils, markings, and even a calling card that identified the kit manufacturer and model number. Below we include a photographic guide to the Aladdin kit home stencil markings and other construction annotations exposed on the framing and sheathing of this building. As exterior siding and felt paper were removed during renovations (below left) blue grease-pencil / crayon markings were visible on some exterior sheathing boards (below right), perhaps as described by Rebecca Hunter (and discussed above)
But as our next two Aladdin construction photos demonstrate (below) we found the more common black inked stencil marking on exterior sheathing boards, most likely indicating their length. Plans and construction guidance for the home required the builder to find the proper framing material by type (2x lumber, sheathing boards, shims, etc.) and dimension or length. [Click any image to see an enlarged, detailed version.]
The hammer marks in our exterior sheathing photo (above right) may have been made during original construction, giving a clue about where the carpenter was standing, through what arc the hammer passed, and how many times she or he missed the nail. [The plywood at left in this photo is a new addition made during renovations.] Inside this Aladdin home the first floor subflooring (below left) was un-marked common yellow pine. But the wall sheathing 2x lumber was plainly marked for its intended use (below right).
Wall framing was conventional 2x4 dimensioned lumber, 16" on center (below left) but a closer look at the under-side of the wall top framing and top plates shows that the lumber length was also marked on pre-cut 2x4's (below right).
At below left you can see the construction grade stamp on the wall 2x4 stud, and the 16'0" length indication on longer sections of exterior wall sheathing, also pre-cut for assembly. Gable-end exterior wall sheathing boards were also pre-cut and labeled as you can see marked (below right). Notice that the stenciled label refers to "Gable Fig. 11" in the instructions. We do read the instructions, right?
From the first floor we can see that joists to frame the second floor structure were plainly labeled (below left). And while we have no doubt that the original builders would have howled with laughter at the mere thought of modern viewers romanticizing what the builders surely found was hot hard work building this home, modern viewers interested in the history of a home may enjoy noticing the hand prints of the original builders, left where oil and sweat marked roof sheathing boards (below right).
Earlier we mentioned the blue grease pencil/crayon markings on some lumber in this home. Considering the extensive stenciled identification of framing components, sheathing, flooring we have found, and based on our own construction experience, a plausible but different explanation from that offered by Hunter for these hand written markings (see the window header at below left, marked 3' 11 1/4) is that they were made by the builders during construction, marking cut-to-length materials adjusted on site, not at the factory.
At above right we show the common corner stud and and overlapping top plate design used to tie the long and short gab le end walls together. Below left you can see that the subflooring material for the second floor was also stenciled for that use. At below right our photo shows that the second floor joists were end-butted together over a load bearing first floor center partition wall. Rather than rely only on toe-nailing the floor joists to the partition wall top plate, 1x lumber plates were face nailed to the butted joist ends to assure that there would be no separation. This allowed use of shorter lumber lengths (more economical) and took advantage of the lower cost of pre-cutting framing lumber to length at the Aladdin kit home factory in Bay City Michigan..
Standard interior wall stud height was pre-cut to 8'- 4-7/8" (below-left) while cripple studs used in interior door frames below door headers were pre-cut to 6'-9-3/8" (below right). Other exterior wall studs were pre-cut and marked at 8'0" so you can see why clear labeling and picking up the correct pre-cut lumber lengths is important in kit home construction.
This Aladdin home included a stone fireplace with a steel firebox (below left) that may have been added later in the life of the property. Notice that leaks at the chimney had rotted the building sheathing to the left of the fireplace stone. At below right we illustrate the second floor knee wall partition framing. The diagonal brace at the photo right was added as a temporary brace during this gut-renovation project. Although kit home framing lumber stencil marks will be mostly hidden by finish materials, take a look in the attic knee wall spaces and you're likely to find identifying markings. That's where we first saw stenciled numbers in this home, several years before this renovation project was undertaken.
Our first photo of this home (shown at the start of this article) shows that the front roof slope included a lower intersecting gable at the left end of the home. A lower-height intersecting roof gable called for some compound miter cuts to form the jack rafters (below left) that may have been difficult for amateur builders to get right - another advantage of factory pre-cut lumber used in kit homes. At below right you can see added stencil markings keying construction framing lumber to the home's assembly instructions. The home also included a larger raised dormer at the rear roof slope, shown below.
When second floor plasterboard was removed from this Aladdin home we were excited to find the Aladdin Home card stapled to a second floor doorway header and shown at below-right. This little business-card document identifies the Aladdin Co., Bay City Michigan, gives the order number for this home # 580013, and includes instructions to the original builder. Aladdin Company Pre-Cut, Pre-Assembled door headers were provided as a pattern for use by the builders.. Aladdin included an example door header (this one with this card attached) along with instructions: 2x4 Header, to be used for any opening calling for 3'-3 1/4" Header, with a note - Assemble all headers in a similar manner using 3/8" spacer material furnished. Spacers to be cut to length on the job. All the amateur builder needed to do was read the instructions and copy this model header to frame in other doorways or windows of the same width, using framing lumber and spacers included in the Aladdin kit.
A List of Manufacturers of Kit Homes and their Identification MarkingsWe've had less success finding details about other kit home companies selling in the United States and Canada, though Rebecca Hunter has compiled a list of a variety of kit house companies. Benefiting from Hunter's work as well as our own search we list a number of kit or catalog home manufacturers here.
Frequently-Asked Questions (FAQs) about Aladdin Kit HousesQuestion: Dear Mr. Friedman, Described below, in an e-mail attempting to establish provenance and historical importance for the Aladdin kit rental house I live in, are my house's technical similarities to the nineteen-teens-and-later Sears Simplex Sectionals, for instance, the interior and one exterior version of a Sears model called "Starlight." If there is any way you can help me in this matter, I should be extremely delighted to have found a way to save the house from a bad future. Here follows the e-mail to Sears. Not incidentally, I'm a little over 15 years younger than the house. - L.H. Subject: Sears Simplex Sectionals My 1910 (King County, WA, county record) rental cottage, very small, exactly matches some of the Sears Simplex Sectional specifications--2-1/2-inch-thick walls made of panels 36" on center, bolted together, same room dimensions, window placement, interior fittings, chimney placement, hip roof, house-wide front porch, dormer at the front (since removed by my now-foreclosed landlord--he said "It might leak."). But it is not a Simplex Sectional, instead having in 1910 come out from Michigan in a railroad flatcar package, numbered parts, detailed instructions, evidently before the birth of Simplex Sectionals. It is an Aladdin kit house, and may be the last extant pioneer specimen of the type in the Pacific Northwest or maybe anywhere. It is historically significant in several ways, standing within ten minutes of downtown Seattle, at the northern crest of the last visible remnant of the once commercially and sociologically important route between "suburb" Renton and the flourishing new city. I have rented here for nearly twenty-eight years, in an old-timey, diversely populated, historically significant area. To save the house from destruction, I very much want to establish it as a candidate for historic preservation. It has passed from bubble-loan landlord to the Bank-lender, then to Fannie Mae, and lastly, by "repurchase," back to the Bank. The Bank wants to raise the rent by $240, not an option for me. It is on a non-conforming-use lot said to be 7600 sq. ft., and to be worth $260,000 to $278,000. Does this indicate an immanent odor of bulldozer? Here is what I need from Sears. By e-mail [or for forwarding to the original reader who asks for this information contact InspectAPedia.com using our CONTACT link at page top, left, or bottom], could you please send some early Simplex Sectional plans with pictures, floor-plans, and interior views that might corroborate my findings. The reason I know that the house is by Aladdin Kit Homes is because the house came from Michigan (Bay City), and Sears Simplex Sectionals did not exist until later than 1910. Years ago an archivist told me that even back then everybody latched on to available good ideas (hence same dimensions and procedures), and that Aladdin records had been donated to the University of Northern Michigan. Unfortunately, those records did not pre-date 1915, though Aladdin had been in business for much longer than that. I will be very thankful if you can be of help. - Louise Hotaling, 3811 Renton Avenue South, Seattle, WA 98108. tele 206-723-3811. Email: hotsdl@mindspring.com Reply:A competent onsite inspection by an expert usually finds additional clues that help identify the origin of a home and its manufacture. That said, if you missed our article on identifying Aladdin kit homes, take a look at ALADDIN KIT HOUSES [the article just above] and our other kit house references and identifcation aids at left. The same process described at How to Identify Sears Kit Houses can help identify the origin of other kit homes. I'm doubtful you'll find someone at modern Sears Roebuck & Co. that can answer your identification questions about your home, but there are several published authors on Sears Kit Houses, as we cite in our references at SEARS KIT HOUSES - and also at Books on Sears and other Kit or Catalog Houses. you might try contacting Rosemary Thornton, for example. Follow-Up:I'd like to be identified. Somebody who knows more than I do about the Aladdin provenance question may catch my name at your site and tell me what he/she knows. I have already said that I talked to a Sears-interest archivist who directed me to Northern Michigan University. Nothing further back than 1915 had been donated to NMU. This house is documented 1910. I'm sending you a photograph of it when I can get it to go. This very night I'll write to Rosemary Thornton. I found out only today that she also has some interest in Aladdin houses. I read her book on the Sears houses many years ago when I still believed the house was a really early Sears Simplex Sectional. I tried to get Sears to investigate it--same panel measurements, hip roof, dormer, window and door placement, same livingroom and diningroom configuration, as the Sears "Starlight" (Thornton, page 76, fig. 75). But I was told that Sears had lost their 1910 catalog, and that seemed to be that. Until researcher-archivists told me that it was probably an Aladdin. Do you know of anyone here who might be considered an expert onsite inspector? It's too late for my informant, lifelong Seattle resident Steve Potteiger, the foreclosed landlord's former factotum, who died of old age more than several years ago. He knew everything there was to know about early Seattle and its environs and history and denizens. Questions & Answers regarding this articleQuestions & answers about Aladdin kit homes: sources, history, identification, repair, inspection Ask a Question or Search InspectAPediaHTML Comment Box is loading comments...
Recommend / Share this Article
... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website. AGE of a BUILDING - how to determine
References for Identifying Aladdin Catalog Homes and other brands
We recommend all three of these publications. Item #1 is a great reference catalog of home designs, organized to help as a field guide. Rosemary Thornton's two books contain additional specific details which you will find instrumental in identifying Sears Catalog Homes. Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
|