InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US


Mobile Phone/PDA website viewMobile View
STRUCTURAL INSPECTIONS & DEFECTS

ADVANCED INSPECTION METHODS
AGE of a BUILDING - how to determine
ARCHITECTURE & BUILDING COMPONENT ID

BASKETBALL MOLD SYNDROME - BBMS
BARK SIDE DOWN on DECKS, TRIM, STEPS
BASKETBALL MOLD SYNDROME - BBMS
BEST CONSTRUCTION PRACTICES GUIDE

BRICK FOUNDATIONS & WALLS
BRICK STRUCTURAL WALL Loose Bulged
Brick Thermal Expansion Cracking
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BUCKLED FOUNDATIONS due to INSULATION?

CHIMNEY INSPECTION DIAGNOSIS REPAIR
COLUMNS & POSTS, DEFECTS
CONCRETE FOUNDATIONS
CONCRETE FOUNDATIONS, PRE-CAST
CRAWL SPACES
  CRAWL SPACE DRYOUT PROCEDURES
  CRAWL SPACE GROUND COVERS
  CRAWL SPACE INSULATION RETROFIT
DECK & PORCH CONSTRUCTION
DECK COLLAPSE Case Study
DECK FINISHES COATINGS PRESERVATIVES
DECK FLASHING LEAKS, ROT Case Study
DECKS, ROOFTOP CONSTRUCTION

DEBRIS STAINING on ROOFS

DEFINITIONS of Mobile Home, Doublewide, Modular, Panelized Construction
  TRAILERS & CAMPERS
  MOBILE HOMES
  DOUBLEWIDE TRAILERS
  PRE-CUT & KIT HOMES
  MODULAR HOME CONSTRUCTION
  PANELIZED CONSTRUCTION

MOBILE HOMES, DOUBLEWIDES, TRAILERS
INTRODUCTION to MOBILE HOMES
PRIORITIES OF MOBILE HOME INSPECTION
MOBILE HOME EXTERIOR DEFECTS
MOBILE HOME LABELS
MOBILE HOME ROOF LEAKS, DEFECTS
MOBILE HOME STRUCTURAL DEFECTS
MOBILE HOME ELECTRICAL DEFECTS
MOBILE HOME HEATING
MOBILE HOME COOLING
MOBILE HOME INSULATION
MOBILE HOME PLUMBING
MOBILE HOME INTERIOR DEFECTS
DOUBLEWIDES, TRAILERS

ENERGY SAVINGS in BUILDINGS

FLOOD DAMAGE ASSESSMENT, SAFETY & CLEANUP
FLOODS IN BUILDINGS-mold
FLOOR, ENGINEERED WOOD & LAMINATES
FLOOR FRAMING & SUBFLOOR for TILE
FLOOR TYPES & DEFECTS
FLOOR TILE ASBESTOS IDENTIFICATION
FLOOR TILE HISTORY & INGREDIENTS

FOOTING & FOUNDATION DRAINS
FOOTINGS EXPOSED, Repair Methods

FOUNDATION BULGE or LEAN MEASUREMENTS
FOUNDATION CONSTRUCTION TYPES
FOUNDATION CONTRACTORS, ENGINEERS
FOOTING & FOUNDATION DRAINS
FOOTINGS EXPOSED, Repair Methods

FOUNDATION CRACKS & DAMAGE GUIDE
FOUNDATION WATERPROOFING

FRAMING DAMAGE, INSPECTION, REPAIR
FRAMING DETAILS for BETTER INSULATION
FRAMING DETAILS for DOUBLE WALL HOUSES
FRAMING & SUBFLOOR for TILE
FRAMING MATERIALS, Age, Types
FRAMING METAL STUD PERFORMANCE
FRAMING METHODS, Age, Types
FRAMING SIZE & Spacing, Age, Types
FRAMING TABLES, SPANS for DECKS

FRENCH DRAINS
FROST HEAVES, FOUNDATION, SLAB
FRT PLYWOOD

GALVANIC SCALE & METAL CORROSION
GLUES ADHESIVES, EXTERIOR CONSTRUCTION
GRADING & SITE WORK, EXTERIOR
GUTTERS & DOWNSPOUTS

HOUSE PARTS, DEFINITIONS
HOUSEWRAP INSTALLATION DETAILS

I-JOISTS, Wood Roof Floor

KIT HOMES, Aladdin, Sears, Wards, Others

LEED GREEN BUILDING CERTIFICATION

LOG HOME GUIDE
LVL Laminated Veneer Lumber, Beams

MOBILE HOMES, DOUBLEWIDES, TRAILERS
MODULAR HOME CONSTRUCTION

MOISTURE CONTROL in BUILDINGS

NOISE / SOUND DIAGNOSIS & CURE

OSB - Oriented Strand Board

PANELIZED CONSTRUCTION
PLASTER BULGES & PILLOWS
PLASTER, LOOSE FALL HAZARDS
PLYWOOD Roof, Wall, Floor Decks & Sheathing
PORCH CONSTRUCTION & SCREENING
PRE-CUT & KIT HOMES
Preservative-Treated Framing Lumber

RAILINGS, DECK & PORCH
RAILINGS, STAIRWAY
RETAINING WALL DESIGNS, TYPES, DAMAGE
RETAINING WALL GUARD RAILINGS
ROT, FUNGUS, TERMITES
ROT, TIMBER FRAME

SEARS KIT HOUSES
SEPTIC & CESSPOOL SAFETY
SHEATHING, FIBERBOARD
SHEATHING, Gypsum board
SHEATHING Homasote & Other Board
SHEATHING, OSB
SHEATHING, Plywood
SHEATHING, FOIL FACED - VENTS
SIDING, Sheathing Identification - Photo Guide
SINKHOLES, WARNING SIGNS
SINKING BUILDINGS

SLAB CRACK EVALUATION
SLAB CRACK REPAIR

Splits in Structural Wood Beams
STAIN & BIODETERIORATION AGENT CATALOG
STAINS on BUILDINGS - QUICK GUIDE
STAIN DIAGNOSIS on BUILDING EXTERIORS
STAIRS, RAILINGS, LANDINGS, RAMPS
STONE CLEANING METHODS
STONE FOUNDATIONS
STRAW BALE CONSTRUCTION
STRESS SKIN INSULATED PANELS
STUCCO WAll FAILURES DUE TO WEATHER
STUCCO WALL METHODS & INSTALLATION
STUCCO OVER FOAM INSULATION
STUCCO PAINT FAILURES
SURFACE GRADING, SITE DRAINAGE

TERMITES, ROT
THERMAL EXPANSION of MATERIALS
THERMAL MASS in BUILDINGS
TRIM, EXTERIOR CHOICES, INSTALLATION
TRUSS UPLIFT, ROOF
TRUSSES, Floor & Roof

VAPOR BARRIERS & CONDENSATION in BUILDINGS
VENTILATION in BUILDINGS

WATER BARRIERS, EXTERIOR BUILDING
WATER ENTRY in BUILDINGS
WIND ENERGY SYSTEMS
WIND TURBINES & LIGHTNING
WINDOWS & DOORS

WINTERIZE A BUILDING

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
AIR CONDITIONING & HEAT PUMPS
BOOKSTORE
ELECTRICAL
ENERGY SAVINGS
ENVIRONMENT
EXTERIORS
HEATING
HOME INSPECTION
INDOOR AIR QUALITY
INSULATION
INTERIORS
MOLD INSPECT/TEST/CLEANUP
NOISE
ODORS
PLUMBING
ROOFING
SEPTIC SYSTEMS
SOLAR ENERGY
STRUCTURE
VENTILATION
WATER SUPPLY

ACCURACY & PRIVACY POLICIES
EXPERT DIRECTORY
CONTACT



Photograph of  this much-modified trailer - this is not a modern mobile home. It was a camper, converted to use as a house, or perhaps an addition to a house.Definition of: Modular Construction, Mobile Homes, Campers, Double-Wides, Trailers, Pre-Cut Homes, & Panelized Construction
InspectAPedia®  -    

  • Definition and description of modular construction
  • Definition and description of mobile homes, double wides, trailers, and campers
  • What is the difference between a mobile home, a manufactured home, a modular home, and panelized construction?
InspectAPedia offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/Contact.htm.

Modular Construction, mobile homes, trailers, campers, doublewides, panelized construction - what are the differences and how are these structures recognized? This article describes the history and characteristics of these different types of factory-built structures.

This set of definitions and identifying characteristics of these homes and construction methods is a supplement to our more detailed paper, Mobile Home Inspections. Readers should also see ARCHITECTURE & BUILDING COMPONENT ID.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Definitions: What is a Mobile Home, Trailer, Doublewide, Modular Home, Factory-Built Home, Panelized-Construction-Built Home?

At ARCHITECTURE & BUILDING COMPONENT ID we included US DOE definitions for the following classes of "manufactured homes":

Manufactured homes are those built entirely in a factory. They are then transported to a building site and installed. Manufactured homes include:

Modular Homes

Modules are transported to the site and installed. See MODULAR HOME CONSTRUCTION for a detailed look at modern modular home construction.

Panelized Homes

Panels—a whole wall with windows, doors, wiring and outside siding—are transported to the site and assembled. See Panelized Construction for a detailed look at a 1950's panelized construction home that was war surplus (Fishkill NY).

Pre-Cut Homes

Building materials are factory-cut to design specifications, transported to the site, and then assembled. Pre-cut homes include kit, dome, and log homes.

LOG HOME GUIDE - provides an example of pre-cut homes, how to inspect, diagnose, and repair problems on log houses; how to identify and determine the age of different types of log homes: traditional log homes, manufactured log homes, slab-sided log homes, and alternative log homes using concrete logs and fiberglass logs.

How to Identify Sears Kit Houses provides the most famous example of pre-cut home construction.

Mobile Homes

This is the term used for factory-built homes produced prior to when the HUD Code went into effect. See MOBILE HOMES, DOUBLEWIDES, TRAILERS for a detailed look at the wide range of quality and condition of these homes.

The following is the opinion of the author and has not had a technical review by other industry experts. Various trailer, mobile home, and modular housing manufacturers may disagree with some of these views. Corrections and content suggestions are welcome.

Characteristics of Trailers as Living Space

Tipping trailer home (C) Daniel Friedman

Trailer traditionally describes a usually small, wheeled, home with a history and image of flimsy construction such as wooden 1x3 wall framing clad with aluminum siding, virtually no insulation, and low quality leaky windows.

"Trailers" up until the 1970's (my estimate) included both campers (photo at left) which really were intended to be towed by a car or truck and moved often from site to site (though some were left parked for decades at campgrounds), and also lightweight factory-made homes which were intended to be towed once to a home site and then kept there.

The camper shown in our photo (left) was abandoned but had previously served as a summer camp for many years.

The little blue structure used as an addition to the left of the small house in the photo at the top of this page was undoubtedly a small camper.

Camper Trailer (C) Daniel FriedmanNo one building "trailers" calls them that any longer because of the "flimsy" image. The closest thing to a "trailer" in current products on the market are motor homes and campers such as these campers parked along Wappingers Creek in our photo (left).

The least-costly campers (such as our pickup truck "slide-on camper") built after 2000 are probably considerably better constructed than the "trailers" of old. In current language (2009), a "trailer" is either a "mobile home" that is more than 20 years old (see below), or it is a camper designed to be moved easily and often from site to site.

(Or in different usage, a "utility trailer" is a utility vehicle intended to haul goods or large items and designed to be fastened to the back of a car or truck, and a "tractor trailer" is of course a larger (typically 40 ft long) hauling system for moving goods by highway from city to city.)

Trailers may have had their wheels left on, but normally they'd be set on a masonry pier foundation and a skirt installed around to hide the under-trailer area.

Characteristics of Mobile Homes as Living Space

Mobile home with bad roof (C) Daniel Friedman

In the past few decades (to 2006), "trailer" manufacturers have considerably improved the quality of construction of such homes. The national manufacturing and building code standards for these structures have also been improved.

Perhaps in part to escape the less than wholesome image of "trailer", manufacturers use the term "mobile home" to describe what is usually larger and better made home than "trailers" of old, though perhaps with similar materials.

Mobile homes are built in a factory and are designed to be moved (once and uncommonly, perhaps once again) on its own wheels attached to its own frame to a site where a foundation is prepared and connections to utilities are made.

In the U.S., states have regulations about the siting, foundation, steps and entry, wiring, plumbing, tie-downs for wind and storm safety that apply to these homes. Some examples of mobile home regulations for New York State are this website. Individual state regulations will vary - you'll want to see what your state requires. Even within states regulations vary as wind and weather conditions do also.

Examples of mobile home improvements include stronger overall wall and roof construction, less leaky roof covering, and windows that are less notoriously leaky. In addition newer mobile homes have, for fire safety, bedroom windows that can be pushed out to a wide opening for emergency exit in case of fire - an important safety improvement.

Usually building departments grandfather in older structures, but sometimes they will insist that certain life-safety improvements be made, for example if an older mobile home is being brought to a new site in a new community. If this is the case one or two windows may need to be replaced to provide this important safety improvement.

When there is a severe storm or hurricane, mobile home communities are among the worst damaged as a strong wind can completely turn over or demolish mobile homes. For this reason, mobile homes set up in high wind-risk zones have extra requirements for tie-downs to secure the building against upset during a storm.

Mobile homes may arrive on wheels but they will be jacked enough to be set on some type of approved building foundation, such as masonry piers or a masonry foundation.

In case these terms are not confusing enough, some mobile home makers like to call these "factory built homes". But that use of "factory-built homes" is confusing too since modular homes are also "factory built" but are quite different from trailers or mobile homes.

Characteristics of a "Doublewide" Mobile Home or Trailer

Some manufacturers provide mobile homes constructed to be joined together, side by side to form a double-width living unit.

While a double-wide mobile home is basically constructed by the same materials and methods just described above, the tie-down and connection requirements for these living units may be different in some jurisdictions, since their risk of being blown away in high winds is different.

Other installation and support requirements, such as connection of the two units and placement of foundation support will also have to accommodate this variation.

Modular home construction and inspection are discussed on a separate series of articles beginning at MODULAR HOME CONSTRUCTION.

Characteristics of Panelized Construction

Panelized construction makes use of wall, floor, ceiling or roof "panels" which have been framed off-site and brought to the site by truck. Panels are lifted into place by crane and fastened together on a foundation, and possibly a framed-in floor which have been prepared before the panels arrive.

Some framing panels make use of special materials, such as plywood and foam roof panels for insulated cathedral ceilings

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

STRUCTURAL INSPECTIONS & DEFECTS

ADVANCED INSPECTION METHODS
AGE of a BUILDING - how to determine
ARCHITECTURE & BUILDING COMPONENT ID

BASKETBALL MOLD SYNDROME - BBMS
BARK SIDE DOWN on DECKS, TRIM, STEPS
BASKETBALL MOLD SYNDROME - BBMS
BEST CONSTRUCTION PRACTICES GUIDE

BRICK FOUNDATIONS & WALLS
BRICK STRUCTURAL WALL Loose Bulged
Brick Thermal Expansion Cracking
BRICK VENEER WALL Loose, Bulged
BRICK WALL DRAINAGE WEEP HOLES
BUCKLED FOUNDATIONS due to INSULATION?

CHIMNEY INSPECTION DIAGNOSIS REPAIR
COLUMNS & POSTS, DEFECTS
CONCRETE FOUNDATIONS
CONCRETE FOUNDATIONS, PRE-CAST
CRAWL SPACES
  CRAWL SPACE DRYOUT PROCEDURES
  CRAWL SPACE GROUND COVERS
  CRAWL SPACE INSULATION RETROFIT
DECK & PORCH CONSTRUCTION
DECK COLLAPSE Case Study
DECK FINISHES COATINGS PRESERVATIVES
DECK FLASHING LEAKS, ROT Case Study
DECKS, ROOFTOP CONSTRUCTION

DEBRIS STAINING on ROOFS
DEFINITIONS of Mobile Home, Doublewide, Modular, Panelized Construction
  TRAILERS & CAMPERS
  MOBILE HOMES
  DOUBLEWIDE TRAILERS
  PRE-CUT & KIT HOMES
  MODULAR HOME CONSTRUCTION
  PANELIZED CONSTRUCTION

MOBILE HOMES, DOUBLEWIDES, TRAILERS
INTRODUCTION to MOBILE HOMES
PRIORITIES OF MOBILE HOME INSPECTION
MOBILE HOME EXTERIOR DEFECTS
MOBILE HOME LABELS
MOBILE HOME ROOF LEAKS, DEFECTS
MOBILE HOME STRUCTURAL DEFECTS
MOBILE HOME ELECTRICAL DEFECTS
MOBILE HOME HEATING
MOBILE HOME COOLING
MOBILE HOME INSULATION
MOBILE HOME PLUMBING
MOBILE HOME INTERIOR DEFECTS

  • "Modular Home Construction, special defects and inspection methods" Dan Friedman, NY Metro ASHI Seminar, Holiday Inn, Crowne Plaza, White Plains NY, October 4, 1996
  • Mobile Home Inspections
  • Trailer vs Mobile Home vs Modular vs Panelized Construction an explanation of terms and how to identify these structures.
  • "Modular Home Construction, special defects and inspection methods" Dan Friedman, NY Metro ASHI Seminar, Holiday Inn, Crowne Plaza, White Plains NY, October 4, 1996
  • Manufactured Housing: types, US DOE - see original source:
    energysavers.gov/your_home/designing_remodeling/index.cfm/mytopic=10210
    • The HUD codes for manufactured homes are at
      http://www.energysavers.gov/your_home/designing_remodeling/index.cfm/mytopic=10220
    • Characteristics of manufactured homes built before 1976, and retrofit suggestions
      http://www.energysavers.gov/your_home/designing_remodeling/index.cfm/mytopic=10230
    • Renewable energy applications for manufactured homes are at
      http://www.energysavers.gov/your_home/designing_remodeling/index.cfm/mytopic=10240
    • Mobile Home Inspections
    • Trailer vs Mobile Home vs Modular vs Panelized Construction an explanation of terms and how to identify these structures.
    • New York State: "Manufactured Homes: an installation guide for the code enforcement official," undated. [Div. of Code Enforcement & Admin. - 518-474-4073, George E. Clark, Jr., Director] - this is a guide tool, not an enforcement code or standard.
    • HUD State Administrative Agency (for 36 states) (NY: 518-474-4073) - for complaints
    • Manufactured Housing Institute, 2101 Wilson Blvd. Ste. 610, Arlington VA 22201 703-558-0400 www.mfghome.org
    • NYMHA, 35 Commerce Ave., Albany NY 12206-2015 518-435-9859 800-721-HOME (they want the Star Program to provide for separate assessment of manufactured homes)
    • Consumer Reports: www.consumerreports.org - special report 2/98
    • Mobile Home Inspection Checklist, Florida, Town of Lady Lake Building Department

    Questions & Answers regarding this article

    .

    Ask a Question or Search InspectAPedia

    HTML Comment Box is loading comments...

    Share this Article      

    ...

    Technical Reviewers & References

    • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
    • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also list books on the specific article topic as well as other references, and information sources.
    • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
    • Additional technical contributors & reference sources for this article are listed below.

    Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

    DEFINITIONS of Mobile Home, Doublewide, Modular, Panelized Construction
      TRAILERS & CAMPERS
      MOBILE HOMES
      DOUBLEWIDE TRAILERS
      PRE-CUT & KIT HOMES
      MODULAR HOME CONSTRUCTION
      PANELIZED CONSTRUCTION

    MOBILE HOMES, DOUBLEWIDES, TRAILERS
    INTRODUCTION to MOBILE HOMES
    PRIORITIES OF MOBILE HOME INSPECTION

    • Carson, Dunlop & Associates Ltd., 120 Carlton Street Suite 407, Toronto ON M5A 4K2. (416) 964-9415 1-800-268-7070 info@carsondunlop.com. Thanks to Alan Carson and Bob Dunlop, for permission to use illustrations from their publication, The Illustrated Home which illustrates construction details and building components. Carson Dunlop provides home inspection education including the ASHI-adopted Home Inspection Training Program (home study course), publications such as the Home Reference Book, report writing materials including the Horizon report writer, and home inspection services. Alan Carson is a past president of ASHI, the American Society of Home Inspectors.
    • Mark Cramer Inspection Services Mark Cramer, Tampa Florida, Mr. Cramer is a past president of ASHI, the American Society of Home Inspectors and is a Florida home inspector and home inspection educator. Contact Mark Cramer at: 727-595-4211 mark@BestTampaInspector.com 11/06
    • Roger Hankey is principal of Hankey and Brown home inspectors, Eden Prairie, MN. Mr. Hankey is a past chairman of the ASHI Standards Committee. Mr. Hankey has served in other ASHI professional and leadership roles. Contact Roger Hankey at: 952 829-0044 - rhankey@hankeyandbrown.com. Mr. Hankey is a frequent contributor to InspectAPedia.com.

    Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

    • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
      • Home Reference Book - Carson Dunlop The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop, and from the InspectAPedia bookstore. The 2010 edition of the Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
    • Best Practices Guide to Residential Construction, by Steven Bliss. John Wiley & Sons, 2006. ISBN-10: 0471648361, ISBN-13: 978-0471648369, Hardcover: 320 pages, available from Amazon.com and also Wiley.com. See our book review of this publication.
    • Decks and Porches, the JLC Guide to, Best Practices for Outdoor Spaces, Steve Bliss (Editor), The Journal of Light Construction, Williston VT, 2010 ISBN 10: 1-928580-42-4, ISBN 13: 978-1-928580-42-3, available from Amazon.com
    • The Journal of Light Construction has generously given reprint permission to InspectAPedia.com for certain articles found at this website. All rights and contents to those materials are ©Journal of Light Construction and may not be reproduced in any form.
    • Appliances and Home Electronics, - energy savings, U.S. Department of Energy
    • Avongard foundation crack progress chart for structural crack monitoring
    • Basement Moisture Control, U.S. Department of Energy
    • Building Failures, Diagnosis & Avoidance, 2d Ed., W.H. Ransom, E.& F. Spon, New York, 1987 ISBN 0-419-14270-3
    • Building Pathology, Deterioration, Diagnostics, and Intervention, Samuel Y. Harris, P.E., AIA, Esq., ISBN 0-471-33172-4, John Wiley & Sons, 2001 [General building science-DF] ISBN-10: 0471331724 ISBN-13: 978-0471331728
    • Building Pathology: Principles and Practice, David Watt, Wiley-Blackwell; 2 edition (March 7, 2008) ISBN-10: 1405161035 ISBN-13: 978-1405161039
    • The Circular Staircase, Mary Roberts Rinehart
    • Construction Drawings and Details, Rosemary Kilmer
    • Crawl Space Moisture Control, U.S. Department of Energy
    • Design of Wood Structures - ASD, Donald E. Breyer, Kenneth Fridley, Kelly Cobeen, David Pollock, McGraw Hill, 2003, ISBN-10: 0071379320, ISBN-13: 978-0071379328
      This book is an update of a long-established text dating from at least 1988 (DJF); Quoting:
      This book is gives a good grasp of seismic design for wood structures. Many of the examples especially near the end are good practice for the California PE Special Seismic Exam design questions. It gives a good grasp of how seismic forces move through a building and how to calculate those forces at various locations. THE CLASSIC TEXT ON WOOD DESIGN UPDATED TO INCLUDE THE LATEST CODES AND DATA. Reflects the most recent provisions of the 2003 International Building Code and 2001 National Design Specification for Wood Construction. Continuing the sterling standard set by earlier editions, this indispensable reference clearly explains the best wood design techniques for the safe handling of gravity and lateral loads. Carefully revised and updated to include the new 2003 International Building Code, ASCE 7-02 Minimum Design Loads for Buildings and Other Structures, the 2001 National Design Specification for Wood Construction, and the most recent Allowable Stress Design.
    • Diagnosing & Repairing House Structure Problems, Edgar O. Seaquist, McGraw Hill, 1980 ISBN 0-07-056013-7 (obsolete, incomplete, missing most diagnosis steps, but very good reading; out of print but used copies are available at Amazon.com, and reprints are available from some inspection tool suppliers). Ed Seaquist was among the first speakers invited to a series of educational conferences organized by D Friedman for ASHI, the American Society of Home Inspectors, where the topic of inspecting the in-service condition of building structures was first addressed.
    • Domestic Building Surveys, Andrew R. Williams, Kindle book, Amazon.com
    • Defects and Deterioration in Buildings: A Practical Guide to the Science and Technology of Material Failure, Barry Richardson, Spon Press; 2d Ed (2001), ISBN-10: 041925210X, ISBN-13: 978-0419252108. Quoting:
      A professional reference designed to assist surveyors, engineers, architects and contractors in diagnosing existing problems and avoiding them in new buildings. Fully revised and updated, this edition, in new clearer format, covers developments in building defects, and problems such as sick building syndrome. Well liked for its mixture of theory and practice the new edition will complement Hinks and Cook's student textbook on defects at the practitioner level.
    • Guide to Domestic Building Surveys, Jack Bower, Butterworth Architecture, London, 1988, ISBN 0-408-50000 X
    • "Avoiding Foundation Failures," Robert Marshall, Journal of Light Construction, July, 1996 (Highly recommend this article-DF)
    • "A Foundation for Unstable Soils," Harris Hyman, P.E., Journal of Light Construction, May 1995
    • "Backfilling Basics," Buck Bartley, Journal of Light Construction, October 1994
    • "Inspecting Block Foundations," Donald V. Cohen, P.E., ASHI Reporter, December 1998. This article in turn cites the Fine Homebuilding article noted below.
    • "When Block Foundations go Bad," Fine Homebuilding, June/July 1998
    • Historic Preservation Technology: A Primer, Robert A. Young, Wiley (March 21, 2008) ISBN-10: 0471788368 ISBN-13: 978-0471788362
    • Log Homes: Minimizing Air Leakage in Log Homes, U.S. Department of Energy
    • Manual for the Inspection of Residential Wood Decks and Balconies, by Cheryl Anderson, Frank Woeste (Forest Products Society), & Joseph Loferski, October 2003, ISBN-13: 978-1892529343, $39.00 at Amazon.com or at the InspectAPediaBookstore
    • Masonry structures: The Masonry House, Home Inspection of a Masonry Building & Systems, Stephen Showalter (director, actor), DVD, Quoting:
      Movie Guide Experienced home inspectors and new home inspectors alike are sure to learn invaluable tips in this release designed to take viewers step-by-step through the home inspection process. In addition to being the former president of the National Association of Home Inspectors (NAHI), a longstanding member of the NAHI, the American Society of Home Inspectors (ASHI), and the Environmental Standard Organization (IESO), host Stephen Showalter has performed over 8000 building inspections - including environmental assessments. Now, the founder of a national home inspection school and inspection training curriculum shares his extensive experience in the inspection industry with everyday viewers looking to learn more about the process of evaluating homes. Topics covered in this release include: evaluation of masonry walls; detection of spalling from rebar failure; inspection of air conditioning systems; grounds and landscaping; electric systems and panel; plumbing supply and distribution; plumbing fixtures; electric furnaces; appliances; evaluation of electric water heaters; and safety techniques. Jason Buchanan --Jason Buchanan, All Movie Review
    • Masonry Design for Engineers and Architects, M. Hatzinikolas, Y. Korany, Canadian Masonry (2005), ISBN-10: 0978006100, ISBN-13: 978-0978006105
    • Masonry Structures: Behavior and Design, Robert G. Drysdale, Ahmid A. Hamid, Lawrie R. Baker, The Masonry Society; 2nd edition (1999), ISBN-10: 1929081014, ISBN-13: 978-1929081011
    • Masonry, Engineered: Using the Canadian Code, J. I. Gainville, Cantext publications (1983), ASIN: B0007C37PG
    • Masonry, Non-reinforced masonry design tables, Hans J. Schultz, National Concrete Producers Association and the Canadian Masonry Contractors Association (1976), ASIN: B0007C2LQM
    • Moisture Control in Buildings, U.S. Department of Energy
    • Moisture Control in Walls, U.S. Department of Energy
    • Quality Standards for the Professional Remodeling Industry, National Association of Home Builders Remodelers Council, NAHB Research Foundation, 1987.
    • Quality Standards for the Professional Remodeler, N.U. Ahmed, # Home Builder Pr (February 1991), ISBN-10: 0867183594, ISBN-13: 978-0867183597
    • R-Value of Wood, U.S. Department of Energy
    • Slab on Grade Foundation Moisture and Air Leakage, U.S. Department of Energy
    • Straw Bale Home Design, U.S. Department of Energy provides information on strawbale home construction - original source at http://www.energysavers.gov/your_home/designing_remodeling/index.cfm/mytopic=10350
    • More Straw Bale Building: A Complete Guide to Designing and Building with Straw (Mother Earth News Wiser Living Series), Chris Magwood, Peter Mack, New Society Publishers (February 1, 2005), ISBN-10: 0865715181 ISBN-13: 978-0865715189 - Quoting:
      Straw bale houses are easy to build, affordable, super energy efficient, environmentally friendly, attractive, and can be designed to match the builder’s personal space needs, esthetics and budget. Despite mushrooming interest in the technique, however, most straw bale books focus on “selling” the dream of straw bale building, but don’t adequately address the most critical issues faced by bale house builders. Moreover, since many developments in this field are recent, few books are completely up to date with the latest techniques.
      More Straw Bale Building is designed to fill this gap. A completely rewritten edition of the 20,000-copy best--selling original, it leads the potential builder through the entire process of building a bale structure, tackling all the practical issues: finding and choosing bales; developing sound building plans; roofing; electrical, plumbing, and heating systems; building code compliance; and special concerns for builders in northern climates.
    • "Vapor Barriers or Vapor Diffusion Retarders", U.S. DOE: how vapor barriers work, types of vapor diffusion barriers, installing vapor barrier
    • Ventilation for energy efficient buildings, Purpose, Strategies, etc.,
    • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com