InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
Home | Air
Conditioning
| Electrical
-
Energy Saving
| Environment
Indoor
| Exteriors | Heating | Home
Inspection
| Insulate
-
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Solar
Energy
| Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


PLUMBING TOPICS
APPLIANCE EFFICIENCY RATINGS
OIL TANKS
SEPTIC SYSTEMS
WATER PRESSURE REGULATOR ADJUST
WATER PRESSURE REPAIR GUIDE & COSTS
WATER PRESSURE LOSS DIAGNOSIS GUIDE
WATER PRESSURE & FLOW MEASUREMENT
WATER PUMPS & WELL TANKS
WATER PUMP CONTROLS & SWITCHES
  IDENTIFY WELL PUMP TANK COMPONENTS
  MAIN WATER SHUTOFF VALVE
  WATER PUMP ELECTRICAL SWITCHES
  WATER PUMP PRESSURE CONTROL
    WATER PUMP PRESSURE CONTROL ADJUSTMENT
    WATER PUMP PRESSURE CONTROL REPAIR
    WATER PUMP PRESSURE CONTROL REPLACE
  WATER PRESSURE REGULATOR ADJUST
  WATER PUMP RELAY SWITCH
  WATER TANK AIR VOLUME CONTROLS
  TANK AIR INLET VALVE
  TANK AIR VALVE REPAIRS
  WATER TANK PRESSURE GAUGE
  WATER PRESSURE GAUGE ACCURACY
  WATER TANK DRAIN VALVE
  WATER TANK RELIEF VALVE
  CHECK VALVES
  WATER FILTERS
WATER PUMP SHORT CYCLING
WATER PUMP TYPES & LIFE EXPECTANCY
WATER PUMP & TANK SAFETY
WATER SHUTOFF VALVE LOCATION, USE
WATER SOURCE ALTERNATIVES
WATER SUPPLY & DRAIN PIPING
WATER TANK TYPES: WATER, OIL, EXPANSION, ALL
WATER TANK LIFE EXPECTANCY
WATER TANK REPAIRS
WATER TANK AIR, HOW TO ADD
WATER TANK BLADDERS & CAPTIVE AIR
WATER TANK BLADDER PRESSURE ADJUSTMENT
WATER TANK PRESSURE CALCULATIONS
WATER TANK PRESSURE GAUGE
WATER TANK SIZE & VOLUME
WATER TANKS HOW THEY WORK
WATER TESTING
WATER TREATMENT EQUIPMENT CHOICES
WELLS CISTERNS & SPRINGS
WELL, PUMP, TANK LIFE EXPECTANCY
WINTERIZE A BUILDING

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Bias Pledge
Contact Us



Photograph of a sketch of the main controls and valves on a water system Water Tank Drain Valve Location & Repair
InspectAPedia®  -    

  • Where do we find the water pressure tank drain valve on a private well, tank, and pump system, how is it used, how to repair leaky valves
  • What are the controls, switches, valves found on water tanks and water pumps, what do they do, how are they repaired?
  • Well pump & water tank diagnosis & repair procedures
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

This article describes Where do we find the water pressure tank drain valve on a private well, tank, and pump system, how is it used, how to repair leaky valves Readers of this document should also see Water pump and pressure tank repair diagnosis & cost an specific case which offers an example of diagnosis of loss of water pressure, loss of water, and analyzes the actual repair cost.

© 2009 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

WATER TANK DRAIN VALVE

Photograph of a water pressure tank air valve

In this same photo you can see a round black handled drain valve in the center of the picture, just below the pressure gauge. This valve is used to completely drain the water tank (and possibly the entire water piping system too).

Usually the water tank drain is connected to a hose which is run outside of the building or to a nearby floor drain. This gauge is not normally opened when the pump is turned on since you'll simply run the pump and flood the building, but we have used it as a convenient way to connect a water hose to the system. We once put out a small fire in this manner.

Photograph of a water pressure tank air valve

Water tank drains should be piped to a visible location: not installed with a drain to a crawl space as this owner did. For convenience, the owner wanted to be able to drain the water system to avoid freezing when this home in Rhinbebeck New York was unoccupied.

But first of all, sending water into the crawl space risks mold, rot, and insect damage to the building, and second, it's generally a bad idea to send any drain, overflow, or relief valve to a hidden location. If the piping is leaking we want to know it.

If the water tank drain is leaking it needs to be repaired (usually a simple internal washer) or replaced. But you can defer this repair by screwing a garden hose cap onto the gauge threaded outlet. We put these caps on all of our tank drains in areas where children are playing since on occasion they've been opened by curious kids.

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.


PLUMBING TOPICSBR /> OIL TANKS
SEPTIC SYSTEMS
WATER PRESSURE REGULATOR ADJUST
WATER PRESSURE REPAIR GUIDE & COSTS
WATER PRESSURE LOSS DIAGNOSIS GUIDE
WATER PRESSURE & FLOW MEASUREMENT
WATER PUMPS & WELL TANKS
WATER PUMP CONTROLS & SWITCHES
  IDENTIFY WELL PUMP TANK COMPONENTS
  MAIN WATER SHUTOFF VALVE
  WATER PUMP ELECTRICAL SWITCHES
  WATER PUMP PRESSURE CONTROL
    WATER PUMP PRESSURE CONTROL ADJUSTMENT
    WATER PUMP PRESSURE CONTROL REPAIR
    WATER PUMP PRESSURE CONTROL REPLACE
  WATER PRESSURE REGULATOR ADJUST
  WATER PUMP RELAY SWITCH
  WATER TANK AIR VOLUME CONTROLS
  TANK AIR INLET VALVE
  TANK AIR VALVE REPAIRS
  WATER TANK PRESSURE GAUGE
  WATER PRESSURE GAUGE ACCURACY
  WATER TANK DRAIN VALVE
  WATER TANK DRAIN VALVE
  WATER TANK RELIEF VALVE
  CHECK VALVES
  WATER FILTERS
WATER PUMP SHORT CYCLING
WATER PUMP TYPES & LIFE EXPECTANCY
WATER PUMP & TANK SAFETY
WATER SHUTOFF VALVE LOCATION, USE
WATER SOURCE ALTERNATIVES
WATER SUPPLY & DRAIN PIPING
WATER TANK TYPES: WATER, OIL, EXPANSION, ALL
WATER TANK LIFE EXPECTANCY
WATER TANK REPAIRS
WATER TANK AIR, HOW TO ADD
WATER TANK BLADDERS & CAPTIVE AIR
WATER TANK BLADDER PRESSURE ADJUSTMENT
WATER TANK PRESSURE CALCULATIONS
WATER TANK PRESSURE GAUGE
WATER TANK SIZE & VOLUME
WATER TANKS HOW THEY WORK
WATER TESTING
WATER TREATMENT EQUIPMENT CHOICES
WELLS CISTERNS & SPRINGS
WELL, PUMP, TANK LIFE EXPECTANCY

 

WATER PUMP, TANK & WELL REPAIRS

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

Plumbing Diagnosis & Repair: Water supply, drainage, septic systems, water testing, water contamination, defective plumbing materials & products.

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

03/02/2010 - 11/29/2007 - InspectAPedia.com/water/WPControl9.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark