This article describes how to diagnose the loss of and need for air in a water tank, how to add air to a building water pressure tank,
and how to detect and correct air and water leaks in a building water supply system where a private well is the
water source. We also discuss how to adjust the building water pressure by setting the cut-in and cut-out
pressure on the pump pressure control switch.
Several alternative procedures for adding air to a water pressure tank are described below along with advice
about what to do when things go wrong, such as finding air and water leaks.
Readers of this document should also see Water pump and pressure tank repair diagnosis & cost an specific case which offers an example of diagnosis of loss of water pressure, loss of water, and analyzes the actual repair cost.
The illustration at page top is courtesy of Carson Dunlop, Inc. in Toronto.
SIGNS OF AIR LOSS - What are the signs of loss of air in the water tank
Short Cycling of the Water Pump: If you hear the pump cycling on and off every few
seconds, or if you see the water pressure squirting
in short bursts at the water tap, the pressure tank needs air.
Sketch courtesy of Carson Dunlop.
Condensate marks or line on the water tank: If on the outside of a water pressure tank the line of
condensation is in upper 70% of tank (or higher than the normal condensate
stains if such marks are visible on the tank) then there is not a large remaining air reserve.
The water pressure tank probably needs
or will soon need air.
Technical notes: This article explains two basic cases of water pressure tank problems that can result in water pump short cycling:
1. Too little air in the water pressure tank:
Unless you live in a climate where there is never condensation on
the exterior of the water tank, normally the (lower) portion of the tank that contains water will be cooler
than the upper tank, causing the condensation of water onto the tank surface.
If the condensate line
is high on the water tank this means it's filling up with water and there is not enough
air charge. (Air resides at the top of the pressure tank and water in the tank bottom.)
(Water Tanks in Dry Climates: if you live in an arid climate like Arizona in the U.S. or San Miguel de Allende in Mexico you may not ever see condensation
on the water tank regardless of other factors.)
Conventional steel water pressure tanks that do not use an internal bladder to separate their air charge from the water in the tank will normally lose air by absorption into the water over time. The rate of air loss, if no leaks are present, depends on the amount of water used and on how well any automatic air volume control is working.
A water pressure tank that has lost its air charge is called a waterlogged tank or water-logged pressure tank. We can add air back to the tank pretty easily (described below at WATER TANK AIR, HOW TO ADD) but we'll also want to know why the tank lost its air charge.
Bladder type or "captive air" water tanks do not normally need to have makeup air added. If you are experiencing water pump short cycling problems with bladder-type water tanks and the problem is not in the pump control or water piping, the problem may be traced to a failure of the bladder itself - a component that may be replaceable. See WATER TANK BLADDERS & CAPTIVE AIR for details.
2. Not enough water in the pressure tank: If your water pressure tank never shows any condensation, perhaps that's because no water or not enough water is entering
the water pressure tank. This is the opposite problem from a water tank that has lost its air charge.
We've found this uncommon case (of no water in the water tank) when the tank was defective,
the pipe into the tank was clogged, or the tank was overcharged with too much air pressure.
If there is too much air in the water pressure tank, this problem is usually self-correcting - the
excess air leaves the tank through the supply piping to the building.
But if the entry to the tank
is blocked, or if the water-containing rubber bladder in a "captive air" water tank is defective
(it can become stuck to itself and remain collapsed), the result can be a rapid on-off short
cycling of the water pump. We test water pressure tanks to see if they're empty or nearly empty
of water by seeing if we can rock or move the tank. If the tank is heavy with water it does
not move easily. Be careful not to jiggle and break a pipe!
Water pressure surging at the sink or tub faucets: If you see the water pressure
spurting or changing between good pressure and weak pressure every 5-20 seconds, the water pump is
turning on and off to rapidly, and something's amiss in the system. Even if the total draw down
cycle (from time the pump cut off until it cuts back on) is a minute, your system may be short cycling or close to it.
Pump relay clicking rapidly: If the actual water pump or well pump is located in the
well or outside in a well pit rather than inside the building, you won't hear the pump turning on and off. However at the pressure
tank is a pressure switch which senses the water pressure and turns the pump on (at low pressure, typically 20 psi
or 30 psi) and off at the end of the pump cycle (at high pressure, typically 40 psi or 50 psi). If the relay
is clicking on and off every few seconds the pump is short cycling and something's amiss in the system.
Effects of ambient air temperature on water tank and pump control operation are not normally any concern whatsoever, but
in the off chance that your water tank is installed in an unusually hot or cold location, you'll want to review
The mathematics to calculate exactly how much difference a given air pressure or air volume change makes inside a
water tank is presented in our companion article
Water Tank Pressure Calculations.
If your water supply problem is not described by the symptoms above the issue may with the building piping, fixtures, or the well's ability to deliver water over a sustained time - the well yield. In this case see the diagnostic guide starting at WATER PRESSURE LOSS DIAGNOSIS & REPAIR
Questions & Answers regarding this article
Questions & answers on how to determine that a water pressure tank has become water-logged or has lost its air charge
Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
Additional technical contributors & reference sources for this article are listed below.
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.
Water Supply & Drain Piping, Wells, Pumps, Water Supply Equipment
Access Water Energy, PO Box 2061, Moorabbin, VIC 3189, Australia, Tel: 1300 797 758, email: sales@accesswater.com.au Moorabbin Office: Kingston Trade Centre, 100 Cochranes Rd, Moorabbin, VIC 3189
Australian supplier of: Greywater systems, Solar power to grid packages, Edwards solar systems, Vulcan compact solar systems, water & solar system pumps & controls, and a wide rage of above ground & under ground water storage tanks: concrete, steel, plastic, modular, and bladder storage tanks.
Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid
Smart Tank, Installation Instructions [ copy on file as /water/Smart_Tank_Flexcon.pdf ] - , Flexcon Industries, 300 Pond St., Randolph MA 02368, www.flexconind.com, Tel: 800-527-0030 - web search 07/24/2010, original source: http://www.flexconind.com/pdf/st_install.pdf
Typical Shallow Well One Line Jet Pump Installation [ copy on file as /water/Jet_Pump_Grove_Elect_Jet_Pumps_1.pdf ] - , Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, Vancouver WA 98665 www.grovelectric.com - web search -7/15/2010 original source: http://www.groverelectric.com/howto/38_Typical%20Jet%20Pump%20Installation.pdf
Typical Deep Well Two Line Jet Pump Installation [ copy on file as /water/Jet_Pump_Grove_Elect.pdf ] - , Grove Electric, G&G Electric & Plumbing, 1900 NE 78th St., Suite 101, Vancouver WA 98665 www.grovelectric.com - web search -7/15/2010 original source: http://www.groverelectric.com/howto/38_Typical%20Jet%20Pump%20Installation.pdf
Water Fact Sheet #3, Using Low-Yielding Wells [ copy on file as /water/Low_Yield_Wells_Penn_State.pdf ] - , Penn State College of Agricultural Sciences, Cooperative Extension, School of Forest Resources, web search 07/24/2010, original source: http://pubs.cas.psu.edu/FreePubs/pdfs/XH0002.pdf
Water pressure tanks - how to diagnose the need for air, how to add air, stop water pump short cycling to avoid damage - water storage water pressure tank safety.
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
The Home Reference Book - the Encyclopedia of Homes, Carson Dunlop & Associates, Toronto, Ontario, 2010, $69.00 U.S., is available from Carson Dunlop, and from the InspectAPedia bookstore. The 2010 edition of the Home Reference Book is a bound volume of more than 450 illustrated pages that assist home inspectors and home owners in the inspection and detection of problems on buildings. The text is intended as a reference guide to help building owners operate and maintain their home effectively. InspectAPedia.com ® author/editor Daniel Friedman is a contributing author. Field inspection worksheets are included at the back of the volume.
Crystal Clear Supply provides portable ceramic water filter purifiers and portable reverse osmosis water treatment equipment - see http://www.crystalclearsupply.com/category_s/7.htm
Handbook of Disinfectants and Antiseptics, Joseph M. Ascenzi (Editor), CRC, 1995, ISBN-10: 0824795245 ISBN-13: 978-0824795245 "The evaluation of chemical germicides predates the golden age of microbiology..." -
This well-focused, up-to-date reference details the current medical uses of antiseptics and disinfectants -- particularly in the control of hospital-acquired infections -- presenting methods for evaluating products to obtain regulatory approval and examining chemical, physical, and microbiological properties as well as the toxicology of the most widely used commercial chemicals.
Potable Aqua® emergency drinking water germicidal tablets are produced by the Wisconsin Pharmacal Co., Jackson WI 53037. 800-558-6614 pharmacalway.com
Principles and Practice of Disinfection, Preservation and Sterilization (Hardcover)
by A. D. Russell (Editor), W. B. Hugo (Editor), G. A. J. Ayliffe (Editor), Blackwell Science, 2004. ISBN-10: 1405101997, ISBN-13: 978-1405101998.
"This superb book is the best of its kind available and one that will undoubtedly be useful, if not essential, to workers in a variety of industries. Thirty-one distinguished specialists deal comprehensively with the subject matter indicated by the title ... The book is produced with care, is very readable with useful selected references at the end of each chapter and an excellent index. It is an essential source book for everyone interested in this field. For pharmacy undergraduates, it will complement the excellent text on pharmaceutical microbiology by two of the present editors."
The Pharmaceutical Journal: "This is an excellent book. It deals comprehensively and authoritatively with its subject with contributions from 31 distinguished specialists. There is a great deal to interest all those involved in hospital infection ... This book is exceptionally well laid out. There are well chosen references for each chapter and an excellent index. It is highly recommended." The Journal of Hospital Infection.: "The editors and authors must be congratulated for this excellent treatise on nonantibiotic antimicrobial measures in hospitals and industry ... The publication is highly recommended to hospital and research personnel, especially to clinical microbiologists, infection-control and environmental-safety specialists, pharmacists, and dieticians."
New England Journal of Medicine: City Hospital, Birmingham, UK. Covers the many methods of the elimination or prevention of microbial growth. Provides an historical overview, descriptions of the types of antimicrobial agents, factors affecting efficacy, evaluation methods, and types of resistance. Features sterilization methods, and more. Previous edition: c1999. DNLM: Sterilization--methods.
U.S. Army Field Manual 21-10, Field Hygiene and Sanitation, 1988, web search 07/02/2010, original source: http://www.enlisted.info/field-manuals/fm-21-10-field-hygiene-and-sanitation.shtml The purpose of this manual is to assist individual soldiers, unit commanders, leaders and field sanitation teams in preventing disease and environmental injuries. The manual provides information on preventive medicine measures (PMM) to the individual soldier as well as essential information for the unit commander, unit leaders, and the unit field sanitation team on applying unit level PMM.
When Technology Fails, Matthew Stein, Chelsea Green Publisher, 2008,493 pages. ISBN-10: 1933392452 ISBN-13: 978-1933392455, "... how to find and sterilize water in the face of utility failure, as well as practical information for dealing with water-quality issues even when the public tap water is still flowing". Mr. Stein's website is www.whentechfails.com/