InspectAPedia.com InspectAPedia®
 

Free Encyclopedia of Building & Environmental Inspection, Testing, Diagnosis, Repair

Ask a Question or Search InspectAPedia

  • HOME
  • AIR CONDITIONING
  • ELECTRICAL
  • EXTERIORS
  • HEATING
  • HOME INSPECTION
  • INTERIORS
  • PLUMBING
  • ROOFING
  • SEPTIC SYSTEMS
  • STRUCTURE
  • WATER SUPPLY
  • ENERGY SAVINGS
  • ENVIRONMENT
  • INDOOR AIR IAQ
  • INSULATION
  • MOLD INSPECT TEST REMOVE
  • NOISE
  • ODORS
  • SOLAR ENERGY
  • VENTILATION
  • EXPERTS DIRECTORY
  • CONTACT US



Mobile Phone/PDA website viewMobile View
WATER PUMPS, TANKS, TESTS, WELLS, REPAIRS

FILTERS, WATER
GREYWATER SYSTEMS

WATER CONTAMINANT LEVELS
WATER FILTERS
WATER HAMMER NOISE DIAGNOSE & CURE
WATER HEATERS
WATER ODORS, CAUSE CURE
WATER PUMP REPAIR GUIDE
WATER PRESSURE LOSS DIAGNOSIS & REPAIR
WATER PRESSURE REPAIR GUIDE - WELLS
WATER PUMP SHORT CYCLING
WATER PUMPS, TANKS, WELLS - BASICS
WATER PURIFIERS
WATER SOFTENERS & CONDITIONERS
WATER TANK BLADDERS & CAPTIVE AIR
WATER TANK REPAIRS
WATER TANK: USES, TROUBLESHOOTING
WATER TESTS, CONTAMINANTS, TREATMENT
WATER TREATMENT EQUIPMENT CHOICES
WELLS CISTERNS & SPRINGS
WELL WATER PRESSURE DIAGNOSIS

More Information

Photograph of  a modern steel well casing and cap extending properly above grade level and properly capped. You can see from
the gray plastic conduit that electrical wires enter the well, informing you that this well is served by an in-well submersible well pump. Drinking Water Tests, Water Contamination Limits, Drinking Water Testing Procedures
InspectAPedia®  -      

  • Water testing advice: how, when, and why to test water, what to test for in drinking water supply
  • Water potability testing guide - water bacteria test guide
  • How to conduct water tests, what water tests to order, how to avoid dishonest or cheating on water tests
  • Wells & water tanks, piping, supply: how to inspect, test, repair
  • Questions & answers about when, how, and why to test well water for contamination: advice for property or home buyers and property or home owners who use a private well for drinking water

This article gives advice on water testing for property or home buyers or home owners, with focus on a strategy for assuring the quality of well water by site inspection, property history investigation, and strategically-selected water tests for contamination. The articles listed on this water testing advice page will answer most questions about drinking water testing, focused on testing water supplied from wells, & water tanks as well as many other building plumbing system inspection or defect topics.

InspectAPedia tolerates no conflicts of interest. We have no relationship with advertisers nor with topics or services discussed at this website.

© Copyright 2012 InspectAPedia.com, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use page top links to major topics or use links at the left of each page to navigate within topics and documents at this website. Green links show where you are in a document series or at this website.

Well Water & Drinking Water Testing Advice: How to Investigate for Water Contaminants at a New or Unknown Property or Well

Our complete list of water testing articles is at the end of this page. Readers needing details about each type of water test should see WATER TEST CHOICES & WATER TEST FEES. After testing your well water, see This article contains links to in-depth articles on inspecting, testing, and repairing problems with drinking water supply and wells, water supply pumps, water tanks, water testing and water treatment.

General advice on water testing when buying a rural property:

The minimum test for water potability elected by many property owners or buyers looks only at bacteria. Some government lenders require more extensive tests such as the FHA and Title-5 water potability testing series. Those and similar "water test package" deals offered by water testing labs can be a good way to spend your water testing dollars as they test for the most common contaminants found in well water in many areas.

Watch out for "False Negative" assurances that Well Water is "Pure"

But property buyers should beware of ordering water tests arbitrarily, Because of the enormous number of potential chemical contaminants that might show up in water, there is a risk of accepting a "false negative" result, that is, a risk of assuming that there are no contaminants in drinking water after a specific water contaminant tests shows a negative result . It may simply be the case that a contaminant that is present was not detected because it was not within the scope of the tests performed.

Therefore to be more confident about the quality of water at a property whose water and land history may be unknown, we recommend a series of escalating steps in water testing and other investigative measures. At several points in the investigation process a property buyer or new owner may decide that the information obtained so far provides enough confidence, or that the information suggests that additional levels of water testing are appropriate.

Site investigation for well water quality concerns

This important step in investigating well water quality includes

A visual inspection for things that might raise a red flag: evidence of chemical, fuel, or fertilizer storage on the property or nearby at sites that drain onto the property, nearby industry (industrial chemicals), nearby orchards (pesticides) or farms (fertilizers) whose land drained across or onto the property.

Among the most basic observations will be the location of the well and its proximity to septic system drainfields, barns, livestock pens, or farm chemical storage tanks or fuel tanks. And of course the type of well (dug, driven point, steel well casing) and depth also have implications for the probability of contamination by surface runoff or subsurface contaminants.

Investigation by asking neighbors, the local health department, and nearby water testing laboratories to determine if they know of specific water quality problems that have been discovered in the neighborhood. This step can sometimes provide surprising payoff such as questions by one of our clients whose Pawling NY well had tested as "OK" for several contaminants. A neighbor pointed out that a paper company had for years dumped acetone and other waste chemicals in an empty field across the street from the client's well. Testing found unusual levels of acetone in the water - an uncommon contaminant as acetone is so volatile, and not something that anyone would have tested for without a clue from a helpful neighbor.

Professional investigation services are available from environmental inspection and testing firms who will research government data bases of known sources of water contamination, but watch out: such investigations may not disclose small local industries or contamination sources.

Choosing Specific Water Test Lab Tests for Water Quality

Informed by step 1 above, the minimum water test that is performed is a bacteria test or "water potability test". While the minimal "presence/absence" test is popular and inexpensive, the test gives a "go / no-go" result (there is or is not a coliform bacteria level at or above 1 colony forming unit (CFU) per 100 ml of water). Keep in mind that no water test assures a zero level of bacteria in water nor do health regulations require it. A more costly water test for bacteria provides an actual count of the bacteria level found, if above certain thresholds - this is a much more useful test as it is diagnostic both before and after attempts to correct a bacteria problem.

Bacteria testing does not itself assure anything about the presence or absence of chemical contaminants or aesthetic contaminants (silt, odors, hardness) in well water. But nevertheless, if a water test "fails" a bacteria test, because a common source of high bacterial levels in well water is the leakage of surface runoff into a well, that means that there is also a higher risk of the presence of other contaminants that might be found on the ground surface (pesticides, fertilizers).

Therefore even if a home owner/buyer decides to perform only the most minimal bacterial testing, the result can be a red flag that more thorough testing for other contaminants is in order.

Where a well is on or near farmland or orchards, water testing labs will often recommend one of two pesticide tests (depending on property age and whether or not it's appropriate to test for DDT or chlordane or newer pesticides, as well as tests that can detect common ingredients in fertilizers.

At a property in Dutchess County, NY, where we found a "permanently-parked" trailer that had been used by Terminix™ to store pesticides I was worried about possible storage leaks and thus pesticide contamination in the nearby well. Tests for pesticides found that there was no contamination of the well nor of soil around the trailer. The pest control company had been careful.

But a subsequent investigation of the property's history disclosed that a metal plating shop had been present in one of the buildings on the site. Tests found high levels of chromium contamination of soils, water, and even a nearby stream bed, resulting in a serious environmental contamination issue that involved the new property owner as well as local, state, and federal environmental officials.

Where the visual inspection or a study of the property history discovers specific potential sources of contamination, it makes sense to discuss these with the water test lab director to decide what tests are most useful to perform.

Watch out: this discussion has focused on well water quality - what is "in" the well water that may make it unsafe or unpalatable to drink. An equally important question is "does the well provide enough water" - a topic discussed at How Much Water is In the Well? and at How to Test Well Water Quantity

More Details About Drinking Water Testing

  • NewArsenic in Drinking Water, health effects, exposure standards, how to remove arsenic from water
  • Bacterial Contamination Tests for Water, what is Total Coliform, why do we test for it, what do test results mean
  • Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid
  • Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters
  • Clearances Required for Wells Distance Between Well & Septic System and other water pollution sources, Online Table of Well Distances
  • DRINKING WATER - EMERGENCY PURIFICATION and DRINKING WATER - EMERGENCY SOURCES discuss where to obtain drinking water in an emergency such as after a natural disaster, hurricane, flood, or fire, and also methods for purifying drinking water for emergency use.
  • Drinking Water Testing Advice for home buyers home owners home inspectors
  • Drinking Water Contaminant Levels - Maximum Allowed
  • Drinking Water Contamination and Pollution How to Detect, Test, Correct, and Prevent Well Water Contamination - US EPA - Groundwater
  • HPC Heterotrophic Plate Count Bacteria - also see BACTERIA TEST GUIDE.
  • Interpreting & Acting On Drinking Water Test Results what the results mean and what to do about them
    • Correcting Unsatisfactory Water what to do, when to do it, treatment alternatives, equipment, filters, etc.
    • Lead Contamination in Drinking Water: how to correct lead in drinking water
    • Lead Poisoning Symptoms (extreme) Feb 2006 NY Times Article on Kosovo Roma Camps
    • Water Treatment for Contamination, Hardness, Odors, Sediment, Etc: choices of systems, recommendations
    • When and How to Shock or Chlorinate a Well - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
  • Lead Test Result Variation Caused by Test Methods and Water Supply Lines/Entry Mains: Advice re: Testing With Lead Pipe & Lead Solder on Plumbing
  • Odors in Drinking Water, causes of odors in water, health risks, treatment for odors
  • Pumps, Tanks, & Wells for Water Systems how to diagnose, purchase, or repair water pumps & water tanks; clearances, distances, maintenance of water wells
  • Sewage or Septic contamination in Buildings - Investigation, Testing and Remediation of sewage backups
  • Tank Types Encyclopedia an encyclopedia of tanks in buildings, water tanks, fuel tanks, gas tanks, heating system expansion tanks, oil tanks, water cisterns, water pressure tanks, pressure booster tanks, antique, modern
  • WATER PRESSURE LOSS DIAGNOSIS & REPAIR: a how to diagnose and repair poor water pressure or loss of water supply
  • Water Quantity Requirements, Home & Outdoor Living
  • WATER SOFTENERS & CONDITIONERS maintenance, adjustment, and water softener effect on drinking water and on septic systems - how to detect and correct hard water or minerals in water
  • Water Supply & Drain Piping, Wells, Pumps, Water Supply Equipment
  • Wells, Cisterns,& Springs types of sources of drinking water, what they look like, what goes wrong, what to do about it

Questions & Answers regarding this article

Questions & answers about when, how, and why to test well water for contamination: advice for property or home buyers and property or home owners who use a private well for drinking water

Ask a Question or Search InspectAPedia

HTML Comment Box is loading comments...

Share this Article      

...

Technical Reviewers & References

  • InspectAPedia.com® - Daniel Friedman - Publisher & Editor.
  • InspectAPedia Bookstore lists recommended books, organized by topic & available for purchase. Most of our articles also include a list of recommended books for the specific article topic as well as other references, and information sources.
  • Critique, contributions wanted: Contact Us to suggest corrections or additions to articles at this website, and if you wish, to receive online listing and credit as a contributor. Particular thanks are due to the many experts and also consumers who read and critique technical articles at InspectAPedia.com.
  • Additional technical contributors & reference sources for this article are listed below.

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

WATER TESTS, CONTAMINANTS, TREATMENT
  CHEATING ON WATER TESTS
  Chlorine - sources in drinking water
  CORRECTING BAD WATER
  EPA GUIDE to WATER QUALITY
  SEWAGE CONTAMINATION
  WATER CONTAMINANT LEVELS
WATER TEST CHOICES & WATER TEST FEES
  ARSENIC in WATER
  BACTERIA TEST GUIDE
  CHEMICAL CONTAMINANTS in WATER
  CHLORAMINE / CHLORINE Tests
  Comprehensive Water Test
  Comprehensive + Pesticides
  COST of Water Tests - Lab Fees
  FHA WATER TESTS REQUIRED
  General Classes of Water Contaminants
  General- water test parameters
  Standard VA FHA, Pesticides
  Title 5- water test parameters
  Herbicide Contamination
  Individual water contaminant tests
  LEAD CONTAMINATION in WATER, HOW to TEST
  MUNICIPAL Water Test Parameters
  PESTICIDES Contamination
  Pesticides in Water, Tests
  TOTAL COLIFORM TESTING
WATER TEST FEES
WATER TESTING GUIDE
  WATER TESTING ADVICE
    SHOULD YOU TEST YOUR WATER?
    PUBLIC vs PRIVATE WATER
    WHEN TO TEST
    WATER TEST COSTS
    SPECIAL SITUATION TESTS
WATER TEST INTERPRETATION
  Common Water Tests for Bacteria
    PA - Coliform Bacteria Test
    M.F.T. - Coliform Bacteria Test
    MPN - Coliform Bacteria Test
  Interpreting Other Water Test Results
  FAILED WATER TESTS - WHAT TO DO
  FAILED WATER TESTS - WHEN to RE-TEST

  • Water pump and pressure tank repair diagnosis & cost an specific case offers an example of diagnosis of loss of water pressure, loss of water, and analyzes the actual repair cost
  • Water pressure tank failures & water pump short cycling diagnosis and repair
  • 1-Bromo-3-chloro-5,5-dimethylhydantoin (C5H6BrClN2O2) is produced world-wide and is also used in cleaners and bathroom disinfectants and deodorizers. Here is an example MSDS for this product, provided by Leisure Time
  • "Bacteria in Drinking Water" - "Chlorine," Karen Mancl, water quality specialist, Agricultural Engineering, Ohio State University Extension. Mancl explains factors affecting the effectiveness of chlorine in water as a means to destroy bacteria and other microorganisms. OSU reports as follows:
    • Chlorine kills bacteria, including disease-causing organisms and the nuisance organism, iron bacteria. However, low levels of chlorine, normally used to disinfect water, are not an effective treatment for giardia cysts. A chlorine level of over 10 mg/1 must be maintained for at least 30 minutes to kill giardia cysts. -- http://ohioline.osu.edu/b795/index.html is the front page of this bulletin
  • "Chemicals and Our Health", Nicholas D. Kristof, New York Times, 16 July 2009, p. 27. This outstanding editorial calls for improvements in public health policy to address phthalates and other environmental contaminants from common chemicals and products in everyday use. - DJ Friedman
  • Crystal Clear Supply provides portable ceramic water filter purifiers and portable reverse osmosis water treatment equipment - see http://www.crystalclearsupply.com/category_s/7.htm
  • CHLORAMINE DISINFECTANTS - disinfectants used to treat drinking water, secondary disinfection.
  • CHLORINE IN DRINKING WATER - Does Chlorine in Drinking Water Harm the Septic Tank? - Septic Tank Cleaning Advice
  • CHLORINE IN SEPTIC WASTEWATER - Septic Tank Maintenance: Chlorine in Septic Systems - Septic Tank Maintenance Advice
  • Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid
  • Chlorinate or Shock a Well, When, How-to - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
  • Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters
  • Correcting Unsatisfactory Water what to do, when to do it, treatment alternatives, equipment, filters, etc.
  • Disinfectants in water: www.epa.gov/ogwdw/mdbp/pdf/alter/chapt_2.pdf provides an article on use of disinfectants for water treatment
  • Drinking Water Contaminant Levels - Maximum Allowed
  • Drinking Water Contamination and Pollution How to Detect, Test, Correct, and Prevent Well Water Contamination - US EPA - Groundwater
  • "Drinking Water Safety in Emergencies", University of Minnesota extension, extension.umn.edu/info-u/nutrition/BJ646.html
  • Drinking Water testing, contamination, correction - all topics
  • Drinking Water Testing Advice for home buyers home owners home inspectors
  • Endocrine Disruptor Exchange, Dr. theo Colborn (also see Our Stolen Future). From that website: The Endocrine Disruption Exchange, Inc. is the only organization that focuses primarily on the human health and environmental problems caused by low-dose and/or ambient exposure to chemicals that interfere with development and function, called endocrine disruptors. ... TEDX's work focuses on the endocrine system, which is the exquisitely balanced system of glands and hormones that regulates such vital functions as body growth, response to stress, sexual development and behavior, production and utilization of insulin, rate of metabolism, intelligence and behavior. Hormones are chemicals such as insulin, thyroxin, estrogen, and testosterone that interact with specific target cells. The interactions occur through a number of mechanisms, the easiest of which to conceptualize is through a lock and key arrangement.
  • Giardia exposure limits for drinking water: see www.mass.gov/dep/water/drinking/standards/giardia.htm is the current regulatory exposure limit (your minimum target for sterilization)
  • Health Effects of Chemical Contaminants in Drinking Water, US Environmental Protection Agency,
  • How to Reduce Lead Contamination in Drinking Water: how to test & correction lead in drinking water
  • Hydrogen peroxide: Wikipedia on history of use of hydrogen peroxide: Information on Hydrogen peroxide as a sterilant is in Wikipedia at en.wikipedia.org/wiki/Sterilization_(microbiology) HO2 has been used for a long time, including by vaporization for sterilizing freeze dryers.
  • Hydrogen Peroxide warning: US FDA Warning about drinking hydrogen peroxide: www.truthorfiction.com/rumors/h/hydrogen-peroxide.htm This article cites a 2003 entry in Journal of Food and Science on using Hy.Perox to sterilize vegetables, referring to E.coli - NOT to Giardia.
  • Iodine: "Do Iodine Water Purification Tablets Provide an Effective Barrier against Cryptosporidium parvum?", Starke, Jeffrey A., Bowman, Dwight D., Labare, Michael, Fogarty, Elizabeth A., and others, Military Medicine, 25 October 2001 [possibly a later version of this article appeared in 2005 -DF] http://www.amsus.org/military medicine/milmed.htm
  • Interpreting Drinking Water Test Results what the results mean and what to do about them
  • Lead Contamination from Water Supply Lines/Entry Mains, Lead Testing & Correcting Contamination from - Lead Pipe Problems/Advice
  • Lead Poisoning: Extreme Lead Poisoning Symptoms Suggested by Feb 2006 NY Times Article on Kosovo Roma Camps
  • National Primary Drinking Water Regulations- The complete regulations regarding these contaminants available from the Code of Federal Regulations Website -(United States)
  • Ohio State University article on the concentration of chlorine necessary to act as an effective disinfectant, and the effects of the water's pH and temperature: See http://ohioline.osu.edu/b795/b795_7.html for details.
  • Our Stolen Future: Are We Threatening Our Fertility, Intelligence, and Survival?--A Scientific Detective Story, Theo Colborn, Dianne Dumanoski, John Peter Meyers. Plume-Penguin Publishing, 1997, ISBN 0-452-27414-1., ISBN13: 9780452274143. This book is a seminal work on endocrine disruptors (chemical contaminants having impact at extremely low levels in the environment).
    Recommended by Daniel Friedman, this book is a critical update to the landmark Silent Spring by Rachel Carson and discusses the effects of minute trace amounts of chemical contaminants in the environment. The text "Identifies the various ways in which chemical pollutants in the environment are disrupting human reproductive patterns and causing such problems as birth defects, sexual abnormalities, and reproductive failure. Reprint. Tour. NYT."
    Amazon.com Review: By O T (Ontario, BC) - 'Our Stolen Future' is a great introduction to one of the most important scientific discoveries in our time. Having recently completed a thesis project at university on Endocrine Disruptors, I have reviewed hundreds of papers on the subject. This book is a good clear overview of the scientific literature on EDs. The authors are experts - Theo Colborn is largely responsible for creating the field by bringing together diverse researchers so they could see the big picture of their work. Many of the principle investigators are interviewed and quoted at length on the way chemicals participate in and interfere with delicate hormonal systems in animals (including humans). The major accomplishment of the book is to make an easy-to-follow story out of complex research. Many resources are available to help you assess the reliability of this story, and the best thing to do if you have any doubts is read review articles in scientific journals (which are easier to understand than technical papers). The Physicians for Social Responsibility (PSR) have a guidebook for health-care professionals on Endocrine Disruptors, and the US EPA has many reports on the matter. Beware of people or websites who try to 'debunk' this book (or the science behind it) by simply declaring it false, flawed or disproven. There is far too much supporting research for so simple a refutation.
    OPINION: Significant and discussed in this book is the observation that at certain critical points in the development of animals, presumably including humans, exposure to extremely low levels of endocrine disruptor chemicals (EDC's) (such as BPA - Bisphenol-A or BPA, Diethylstilbestrol - DES, dioxins, PCBs, and chemicals used in the production of certain cleansers, dyes, flame retardants, plastics, pesticides, white papers ) perhaps just a few molecules, or in the parts per trillion, is sufficient to cause disruption of the animal's development, including proper sex differentiation, or the lack of it that produced androgynous ducks unable to reproduce under such conditions.
    A endocrine disruptor is a synthetic chemical compound that mimics natural hormones when it is taken into the body of a human or other animal. It "disrupts" the endocrine system by turning on or off normal chemical signals that in turn can affect normal hormone levels, bodily functions, and significantly, the development of embryos. Further, unlike naturally occurring hormones ingested, for example from plants (phytoestrogens), synthetically-generated hormones accumulate in the body and can have a half-life of decades or longer.
    One significance of this finding includes the observation that an important medical effect that occurs with exposure to chemicals in extremely low concentrations means that experiments to test for correlations between chemical exposure and subsequent serious medical problems will be deeply flawed if, for example, the experimental design does not include testing for the presence of the chemical at extremely low levels. A related concern is that even if harmful effects from exposure to extremely low concentrations of an endocrine disruptor are occurring, teasing out and proving that relationship can be also extremely difficult.
  • Silent Spring, Rachael Carson, Mariner Books; Anv edition (October 22, 2002), ISBN-13: 978-061824906.
    Amazon.com Review: Silent Spring, released in 1962, offered the first shattering look at widespread ecological degradation and touched off an environmental awareness that still exists. Rachel Carson's book focused on the poisons from insecticides, weed killers, and other common products as well as the use of sprays in agriculture, a practice that led to dangerous chemicals to the food source. Carson argued that those chemicals were more dangerous than radiation and that for the first time in history, humans were exposed to chemicals that stayed in their systems from birth to death. Presented with thorough documentation, the book opened more than a few eyes about the dangers of the modern world and stands today as a landmark work.
  • Shock or Chlorinate a Well, When, How-to - Procedure for Shocking a Well to (temporarily or maybe longer) "Correct" Bacterial Contamination
  • US EPA: list of drinking water contaminants: see http://www.epa.gov/safewater/contaminants/index.html
  • UV light: This patent application for UV light sterilization www.patentstorm.us/patents/6565803.html Lists good references on water purification for Giardia et als
  • Water Requirements, Home & Outdoor Living - how much water do people use, how much water do people need?
  • Water Tests & Fees example water test fee schedule
  • Water Testing: background comments on classes of water contaminants, & links to home buyer advice about water testing, drinking
  • Water Treatment for Contamination, Hardness, Odors, Sediment, Etc: choices of systems, recommendations
  • Cheating on water tests: Testing Water for Real Estate Transactions - make sure your water test is valid

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the InspectAPedia Bookstore. Also see our Book Reviews - InspectAPedia.
  • When Technology Fails, Matthew Stein, Chelsea Green Publisher, 2008,493 pages. ISBN-10: 1933392452 ISBN-13: 978-1933392455, "... how to find and sterilize water in the face of utility failure, as well as practical information for dealing with water-quality issues even when the public tap water is still flowing". Mr. Stein's website is www.whentechfails.com/
  • ...
Home About Us Accuracy Contact Us Content Use Policy Privacy Website Description © 2012 Copyright InspectAPedia.com