InspectAPedia ®

Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice
Home | Air
Conditioning
| Electrical
-
Energy Saving
| Environment
Indoor
| Exteriors | Heating | Home
Inspection
| Insulate
-
Ventilate
| Interiors | Mold
Inspect/Test
| Plumbing
Water
Septic
| Roofing | Solar
Energy
| Structure | Contact Us
Directory of Professionals to Inspect or Test a Building


ENVIRONMENTAL HAZARDS GUIDE
WATER SOURCE ALTERNATIVES
WATER TESTING
  WATER TESTING ADVICE
    SHOULD YOU TEST YOUR WATER?
    PUBLIC vs PRIVATE WATER
    WHEN TO TEST
    WATER TEST COSTS
    SPECIAL SITUATION TESTS
  ARSENIC in WATER
  BACTERIA TEST GUIDE
  CHEMICAL CONTAMINANTS in WATER
  CHEATING on WATER TESTS
  CHOICES of WATER TESTS
  CORRECTING BAD WATER
    Common Water Tests for Bacteria
    FAILED WATER TESTS - WHAT TO DO
    WELL SHOCK / CHLORINATION PROCEDURE
    FAILED WATER TESTS - WHEN to RE-TEST
  EPA GUIDE to WATER QUALITY
    Ground water & Well Contamination
    Drinking Water from Household Wells
    What Is Ground Water, How Is It Polluted
    Where Do Water Pollutants Come From
    Naturally Occurring Pollution Sources
    Private Well Contaminant Concerns
    Pollution due to Humans
    Level of Risk of Water Contamination
    Six Steps to Well Water Safety
    Protecting Ground Water From Contaminants
    1. How To Spot Well Contamination Problems
    2. Well Water Test Strategy
    Reasons to Test Well Water
    3. Understanding Water] Test Results
    4. Well Construction and Maintenance
    5. Talk With Local Water Experts
    6. Fix Well Water Contamination Problems
    More Information on Well Water
    Well Water Definitions
  FHA WATER TESTS REQUIRED
  LEAD in WATER, ACTION GUIDE
  LEAD POISONING SYMPTOMS
  LEAD TEST VARIATION CAUSES
  ODORS IN WATER
  SEWAGE CONTAMINATION
  TOTAL COLIFORM TESTING
  WATER CONTAMINANT LEVELS
WATER TEST INTERPRETATION
WATER TESTING GUIDE
WATER TREATMENT EQUIPMENT CHOICES
  WATER TREATMENT EQUIPMENT CHOICES
  WATER ODORS, CAUSE CURE
  WATER PUMPS & WELLS
  WATER QUALITY TESTS, CONTAMINANTS, TREATMENT
WATER QUANTITY IMPROVEMENT
WATER QUANTITY USAGE GUIDE
  WATER SOFTENERS
  WELL SHOCKING GUIDE
WELLS CISTERNS & SPRINGS
WATER PRESSURE LOSS DIAGNOSIS GUIDE
WATER PRESSURE & FLOW MEASUREMENT
  WATER TANK TYPES
  WELL CHLORINATION SHOCKING PROCEDURE
  WELL CLEARANCE DISTANCES
  WELL TYPES
  WELL, PUMP, TANK LIFE

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning
InspectAPedia Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us



Photograph of  a loose, unsanitary well plumbing system exposed to surface water runoffr  © DJ Friedman Reasons to Test Water from Household Wells
InspectAPedia®  -    

- ground water pollution prevention, well water testing, well water safety, US EPA advice part 12

  • Sources of ground water pollution of drinking water & wells
  • Health concerns about water pollution
  • Levels of risk due to water contaminants
  • Steps to improve well water safety
  • Protecting ground water
  • How to correct ground water contamination
Our site offers impartial, unbiased advice without conflicts of interest. We will block advertisements which we discover or readers inform us are associated with bad business practices, false-advertising, or junk science. Our contact info is at InspectAPedia.com/appointment.htm.

If your family gets drinking water from your own well, do you know if your water is safe to drink? What health risks could you and your family face? Where can you go for help or advice? This pamphlet helps answer these questions.

This article gives you general information about drinking water from home wells (also considered private drinking water sources). It describes types of activities in your area that can create threats to your water supply. This text also describes problems to look for and offers maintenance suggestions.

Sources for more information and help are also listed. [Editing for clarity by DF are marked by brackets or italics] Initial Source: EPA 816-K-02-003 January 2002

Edits, content addition, & web page design © 2009 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

Reasons to Test Your Water [and What Water Tests to Order for Various Situations]

Conditions or Nearby Activities: Test for: (also See CHEATING ON WATER TESTS)
Recurring gastrointestinal illness Coliform bacteria - See BACTERIA TEST GUIDE and TOTAL COLIFORM TESTING
Household plumbing contains lead pH, lead, copper - LEAD CONTAMINATION in WATER, HOW to TEST
Radon in indoor air or region is radon rich Radon
Corrosion of pipes, plumbing Corrosion, pH, lead -See LEAD CONTAMINATION in WATER, HOW to TEST and   LEAD in WATER, ACTION GUIDE and  LEAD POISONING SYMPTOMS and  LEAD TEST VARIATION CAUSES
Nearby areas of intensive agriculture Nitrate, pesticides, coliform bacteria, also See SEWAGE CONTAMINATION
Coal or other mining operations nearby Metals, pH, corrosion
Gas drilling operations nearby Chloride, sodium, barium, strontium
Dump, junkyard, landfill, factory, gas station, or dry-cleaning operation nearby Volatile organic compounds, total dissolved solids, pH, sulfate, chloride, metals
Odor of gasoline or fuel oil, and near gas station or buried fuel tanks Volatile organic compounds -ODORS IN WATER
Objectionable taste or smell Hydrogen sulfide, corrosion, metals
Septic system failures or septic too close to well Sewage, coliform bacteria, nitrates, nitrites - See SEWAGE CONTAMINATION
Stained plumbing fixtures, laundry Iron, copper, manganese
Salty taste and seawater, or a heavily salted roadway nearby Chloride, total dissolved solids, sodium
Scaly residues, soaps don't lather Hardness
Rapid wear of water treatment equipment pH, corrosion
Water softener needed to treat hardness Manganese, iron
Water appears cloudy, frothy, or colored Color, detergents

Share this Article      

...

Technical Reviewers & References

Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.

EPA GUIDE to WATER QUALITY
    Ground water & Well Contamination
    Drinking Water from Household Wells
    What Is Ground Water, How Is It Polluted
    Where Do Water Pollutants Come From
    Naturally Occurring Pollution Sources
    Private Well Contaminant Concerns
    Pollution due to Humans
    Level of Risk of Water Contamination
    Six Steps to Well Water Safety
    Protecting Ground Water From Contaminants
    1. How To Spot Well Contamination Problems
    2. Well Water Test Strategy
    Reasons to Test Well Water
    3. Understanding Water] Test Results
    4. Well Construction and Maintenance
    5. Talk With Local Water Experts
    6. Fix Well Water Contamination Problems
    More Information on Well Water
    Well Water Definitions

Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair

  • Our recommended books about building design, inspection, and repair, and about indoor environment testing, diagnosis, and cleanup are at the InspectAPedia Bookstore.
  • ...
ENVIRONMENTAL HAZARDS GUIDE
MVOCs & MOLDY MUSTY ODORS
MYCOTOXIN EFFECTS of MOLD EXPOSURE
NOISE / SOUND DIAGNOSIS & CURE
ODOR DIAGNOSIS CHECKLIST
ODORS & SMELLS DIAGNOSIS & CURE
WATER TESTING GUIDE

More Information

InspectAPedia.comInspectAPedia ® Home & Site Map
InspectAPedia Blog - News Updates
Air Conditioning & Heat Pumps
Bookstore
Electrical
Environment
Exteriors
Heating
Home Inspection
Insulate Ventilate
Interiors
Mold Inspect/Test
Plumbing Water Septic
Roofing
Structure
Accuracy & Privacy Policies
Contact Us

More Information on Building Diagnostic Inspections and Repairs

Water Supply & Drain Piping, Wells, Pumps, Water Supply Equipment

InspectAPedia.comInspectAPedia® Home & Site Map - Building & Environmental Inspection, Testing, Diagnosis, Repair, & Problem Prevention Advice: In-depth research & advice on diagnosing, testing, correcting, & preventing building defects & indoor environmental hazards. Unbiased information, no conflicts of interest.
GO TO the MOLD and INDOOR ENVIRONMENT INFORMATION CENTER for in-depth advice on avoiding testing for or cleaning up mold and other indoor environmental hazards, odors, gases, contaminants
The Mold Information Center:
What to Do About Mold in Buildings, When and How to Inspect for Mold, Clean Up Mold, or Avoid Mold Problems
GO TO MOLD TEST KITS: This expert-recommended mold test kit is cheap and yet top performing *IF* you use a competent analysis laboratory!
Use this simple, economical mold test kit
by following our instructions on how to collect and mail mold samples to our lab
GO TO IAQ/MOLD-TEST LAB SERVICES: Mold, Pollen, indoor air quality, field and laboratory services by an expert.Environmental Inspection, Testing, & Diagnosis On-Site IAQ, Gas, Air Testing, Mold Investigation, Sick Building Diagnosis, Lab Services, & Remediation Plan Preparation - indoor air quality testing, problem source determination, supporting lab work, written remediation plan addressing removal of environmental and other hazards and prevention of their recurrence.
GO TO our PRE PURCHASE BUILDING INSPECTION SERVICES: Authoritative information for home buyers and home owners is included with your inspection.
Building Inspection, Problem Diagnosis
, Forensic Investigation & Testing, Repair Consulting

CONTACT Daniel Friedman - Dan is a senior ASHI home inspector, nationally recognized expert on building inspection, building failures, and sick building investigation
Contact Daniel Friedman for website content suggestions or for fee-paid consulting

03/02/2010 - 12/31/2002 - InspectAPedia.com/water/Water_Pollution_36.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark