WATER TESTING WATER TESTING ADVICE SHOULD YOU TEST YOUR WATER? PUBLIC vs PRIVATE WATER WHEN TO TEST WATER TEST COSTS SPECIAL SITUATION TESTS ARSENIC in WATER BACTERIA TEST GUIDE CHEMICAL CONTAMINANTS in WATER CHEATING ON WATER TESTS Disappearing Septic Dye How much bleach to cheat Sources of chlorine in water How to avoid test dishonesty Re Testing Water CHOICES of WATER TESTS CORRECTING BAD WATER EPA GUIDE to WATER QUALITY FHA WATER TESTS REQUIRED LEAD in WATER, ACTION GUIDE LEAD POISONING SYMPTOMS LEAD TEST VARIATION CAUSES ODORS IN WATER SEWAGE CONTAMINATION TOTAL COLIFORM TESTING WATER CONTAMINANT LEVELS WATER TEST INTERPRETATION WATER TESTING GUIDE WATER TREATMENT EQUIPMENT CHOICES WATER ODORS, CAUSE CURE WATER PUMPS & WELLS WATER QUALITY TESTS, CONTAMINANTS, TREATMENT WATER QUANTITY IMPROVEMENT WATER QUANTITY USAGE GUIDE WATER SOFTENERS WELL SHOCKING GUIDE WELLS CISTERNS & SPRINGS WATER PRESSURE LOSS WATER TANK TYPES WELL CLEARANCE DISTANCES WELL TYPES WELL, PUMP, TANK LIFE InspectAPedia Blog - News Updates Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Privacy Policies More Information Contact Us |
This article explains why people might do something that prevents you from obtaining an accurate water test, how to detect this bad behavior, and what to do about it. Cheating on drinking water tests may come as a surprise to most folks - who would do such a thing, and why? Also see Choices of Water Tests & Fees: A Summary of Types of Water Tests, Degrees of Comprehensive Water Testing, Details of Water Test Parameters. and Water Testing Advice based on information from Cornell University of Maryland with extensive edits, text additions, and additional references. © 2009 Daniel Friedman, All Rights Reserved. Information Accuracy & Bias Pledge is at below-left. Use links at the left of each page to navigate this document or to view other topics at this website. Green links show where you are in our document or website.How much bleach will be needed to cheat on water and septic testing?
How much bleach would you need to obscure a septic loading and dye test? Four grams of 12% bleach will remove the coloration of one gram of septic dye in solution according to Tramfloc Inc. When performing a septic loading and dye test we use a minimum of one tablespoon of septic dye powder - which is about 2/10 of an ounce by weight to dye a 1000 gallon septic tank during a septic dye test. Since an ounce is about 28 grams by weight, this means we're using about 5 grams of powder. So if my math is correct, 20 grams of 12% bleach would obscure a septic dye test. The cheapest household bleach is about 5.25% in strength. A gallon, or 128 oz, should be more than enough. It doesn't take much bleach to lie to the dye. As we mention in the list above, people might shock a well for a legitimate reason, as one step in determining if the building piping or well casing have become soiled and contaminated or after actually doing work on the well pump or piping in the well itself. Shocking a well with bleach will have only a temporary effect in reducing the bacteria level in water if there is a persistent source of contamination in the water supply. We discuss this water problem diagnosis procedure in detail at Interpreting Drinking Water Test Results and Correcting Unsatisfactory Drinking Water and the details of well shocking with bleach are located there. ... Technical Reviewers & References
Use links just below or at the left of each page to navigate this document or to view other topics at this website. Green links at page left show where you are in our document or website. CHEATING ON WATER TESTS WATER TESTING ADVICE
Books & Articles on Building & Environmental Inspection, Testing, Diagnosis, & Repair
| ||||||
| WATER TESTING ADVICE More Information InspectAPedia Blog - News Updates Air Conditioning & Heat Pumps Bookstore Electrical Environment Exteriors Heating Home Inspection Insulate Ventilate Interiors Mold Inspect/Test Plumbing Water Septic Roofing Structure Accuracy & Privacy Policies Contact Us |
More Information on Building Diagnostic Inspections and Repairs
|
12/03/2009 - 08/11/95 - InspectAPedia.com/water/watercheater2.htm - © 2010 - 1988 Copyright Daniel Friedman All Rights Reserved - InspectAPedia® is a Registered U.S. Trademark